Loading...
HomeMy WebLinkAboutEnergy Code- ;FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR RECEIVED DEC 10 2019 BUILDI N Florida Department of Business and Professional Regulation - Residential Peifiormance Method Project Name: Bradescu Residence Builder Name: Street: 7605 Roberts Road Permit Office: St. Lucie County City, State, Zip: Fort Pierce, FL, 34951 Permit Number: Owner: loan Bradescu Jurisdiction: St. Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(1232.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Ext Insul, Exterior R=4.1 1048.00 ft' b. Frame - Wood, Adjacent R=11.0 184.00 ft' 3. Number of units, if multiple family 1 r,. WA R= I 4. Number of Bedrooms 3 d. N/A R= ft' 5. Is this a worst case? No 10. Ceiling Types (1282.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1282.00 ftz 6. Conditioned floor area above grade (ft') 1282 b. N/A R= ft. Conditioned floor area below grade (112) 0 c. NIA R= ft' 11. Ducts R ft' 7. Windows(157.8 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: A/H 6 125 a. U-Factor: SgI, U=0.28 157.80 ft' SHGC: SHGC=0.18 b. U-Factor. N/A ft' 12. Cooling systems kBtufhr Efficiency SHGC: a. Central Unit 28.8 SEER:16.00 c. U-Factor: N/A ft' SHGC: _ 13. Heating systems kBtuthr Efficiency d. U-Factor: N/A ft' a. Electric Strip Heal 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 1.557 ft. Area Weighted Average SHGC: 0.180 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (1282.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1282.00 fl' b. Conservation features b. WA R= ft' None c. WA R= ft' 15. Credits CF, Pstat Total Proposed Modified Loads: 44.99 GlasslFloorArea: 0.123 PASS Total Baseline Loads: 47.11 I hereby certify that the plans and specifications covered by Review of the plans and ,THE Sr this calculation are in compliance with the Florida Energy specifications covered by this pYOB , • '-_ Code. calculation indicates compliance ;FOB, with the Florida Energy Code. ..... -. ;;°.r°�•°;:�3„ �O PREPA D Y: Before construction is completed ui - DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. COD WE'(Sz� OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 11/20/2019 8:24 AM EnergyGauge(10 USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Com giant �ajnf: r g f FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Bredescu Residence Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1282 Lot # Owner Name: loan Bradescu Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No Plat600k: Builder Name: Rotate Angle: 0 Street: 7605 Roberts Road Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Single-family FL, 34951 New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1282 10256 SPACES Number Name Area Volume kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Dining 117 936 No 2 1 Yes Yes Yes 2 i0chen 117 936 Yes 2 1 Yes Yes Yes 3 M. Bathroom 54 432 No 0 1 Yes Yes Yes 4 WIC 36 288 No 0 1 No Yes Yes 5 Master Bedroom 192 1536 No 2 1 1 Yes Yes Yes 6 Living Room 264 2112 No 2 1 Yes Yes Yes 7 Foyer 65 520 No 0 1 Yes Yes Yes 8 Laundry 49 392 No 0 1 No Yes Yes 9 Bedroom 3 156 1248 No 1 1 1 Yes Yes Yes 10 Bathroom 54 432 No 0 1 Yes Yes Yes 11 Bedroom 2 144 1152 No 1 1 1 Yes Yes Yes 12 A/H 16 128 No 0 1 No Yes Yes 13 Hall 18 144 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Dining 22 R 0 117 ft' 1 0 0 2 Slab -On -Grade Edge Insulatio kitchen 9 it 0 117 ft' ___ 1 0 0 3 Slab -On -Grade Edge Insulatio M. Bathroom E ft 0 54 ft' __ 1 0 0 4SIab-On-Grade Edge Insulatio WIC i it 0 36 ft' ____ 1 0 0 11/20/2019 8:24 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab -On -Grade Edge Insulatio Master Bedroom 33 it 0 192 ft2 1 0 0 6 Slab -On -Grade Edge Insulatio Living Room 14 it 0 2041112 __ 1 0 0 7 Slab -On -Grade Edge Insulatio Foyer 5 it 0 65 ft2 1 0 0 8 Slab -On -Grade Edge Insulatio Laundry 1 it 0 49 ft2 ---- 1 0 0 9 Slab -On -Grade Edge Insulatio Bedroom 3 25 ft 0 156 ft2 __ 1 0 0 1 Wlab-On-Grade Edge Insulatio Bathroom E ft 0 54 ft2 1 0 0 11Slab-On-Grade Edge Insulatio Bedroom 2 11 ft 0 144 ft2 __ 1 0 0 12SIab-On-Grade Edge Insulatio A/H 1 ft 0 16 ft2 1 0 0 13SIab-On-Grade Edge Insulatio Hall 1 ft 0 18 ft2 __ 1 0 0 ROOF Roof Gable Roof - Red Solar SP. Emitt Emitt Deck. Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1389 ft2 0 ft2 Light N 0.6 No 0.9 No 0 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1282 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type _ 1 Under Attic (Vented) Dining 30 Batt 117 ft2 0.1 Wood 2 Under Attic (Vented) Kitchen 30 Batt 117 ft2 0.1 Wood 3 Under Attic (Vented) M. Bathroom 30 Batt 54 ft2 0.1 Wood 4 Under Attic (Vented) WIC 30 Batt 36 ft2 0.1 Wood 5 Under Attic (Vented) Master Bedroom 30 Batt 192 ft2 0.1 Wood _ 6 Under Attic (Vented) Living Room 30 Batt 264 ft2 0.1 Wood _ 7 Under Attic (Vented) Foyer 30 Batt 65 ft2 0.1 Wood 8 Under Attic (Vented) Laundry 30 Batt 49 ft2 0.1 Wood 9 Under Attic (Vented) Bedroom 3 30 Batt 156 ft2 0.1 Wood 10 Under Attic (Vented) Bathroom 30 Batt 54 W 0.1 Wood 11 Under Attic (Vented) Bedroom 2 30 Batt 144 112 0.1 Wood 12 Under Attic (Vented) A/H 30 Batt 16 ft2 0.1 Wood 13 Under Attic (Vented) Hall 30 Batt 18 ft2 0.1 Wood 11/20/2019 8:24 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below It Omt Tn Space Wall Type _ 1 E Exterior Concrete Block - Ext Insul Dining 4.1 9 0 8 0 72.0 ft' 0 0 0.6 0 -2 S Exterior Concrete Block - Ext Insul Dining 4.1 13 0 8 0 104.0 ft2 0 0 0.8 0 -3 E Exterior Concrete Block - Ext Insul Kitchen 4.1 9 0 8 0 72.0 ft2 0 0 0.6 0 _ 4 E Exterior Concrete Block - Ext InM Bathroom 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 _ 5 N Exterior Concrete Block- Ext InMhster Bedro 4.1 15 0 8 0 120.0 ft2 0 0 0.6 0 _ 6 E Exterior Concrete Block- Ext lnUbster Bedro 4.1 13 0 8 0 104.0 ft2 0 0 0.6 0 _ 7 W Exterior Concrete Block - Ext InNhster Bedro 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 _ 8 S Exterior Concrete Block - Ext InsLiving Room 4.1 14 0 8 0 112.0 ft' 0 0 0.6 0 _ 9 N Exterior Concrete Block - Ext Insul Foyer 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 _ 10 S Exterior Concrete Block - Ext InstRedroom 3 4.1 12 0 8 0 96.0 ft2 0 0 0.6 0 11 W Exterior Concrete Block - Ext InsLBedroom 3 4.1 13 0 8 0 104.0 ft2 0 0 0.6 0 _ 12 W Exterior Concrete Block - Ext InsuBathroom 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 _ 13 W Exterior Concrete Block - Ext Insdiledroom 2 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 _ 14 N Garage Frame -Wood Bedroom 2 11 13 8 104.0 ft2 0 0.23 0.600000 0 _ 15 N Garage Frame -Wood Laundry 11 6 8 48.0 ft2 0 0.23 0.600000 0 16 N Garage Frame -Wood Foyer 11 4 8 32.0 ft2 0 0.23 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Wood Foyer None .39 3 6 10 20.5 ft2 WINDOWS Orientation shown is the entered Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 1 Metal Low-E Single Yes 0.28 0.18 N 15.0 ft2 1 ft 5 in 1 It 4 in None None 2 S 2 Metal Low-E Single Yes 0.28 0.18 N 30.0 ft2 1 ft 5 in 1 It 4 in None None 3 E 4 Metal Low-E Single Yes 0.28 0.18 N 6.0 ft2 1 ft5 in 1 ft 41n None None 4 N 5 Metal Low-E Single Yes 0.28 0.18 N 30.0 ft2 1 ft S in 1 It 4 in None None 5 S 8 Metal Low-E Single Yes 0.28 0.18 N 40.8 ft2 2 ft 0 in 1 It 4 in None None 6 W 11 Metal Low-E Single Yes 0.28 0.18 N 15.0 ft2 1 ft 5 in 1 It 4 in None None 7 W 12 Metal Low-E Single Yes 0.28 0.18 N 6.0 ft2 1 ft 5ln 1 ft 41n None None 8 W 13 Metal Low-E Single Yes 0.28 0.18 N 15.0 112 1 ft 5 In 1 ft 41n None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 380 ft2 380 ft2 21 ft 8 It 11 11/20/2019 8:24 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1196.5 65.69 123.54 .1233 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Duds 1 Electric Strip Heat/ None COPA 27 kBlu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Duds 1 Central Unit/ Split SEER: 16 28.8 kBlu/hr dm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft' DUCTS 1 —Supply— t # Location R-Value Area —Return Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC# Heat Cool 1 Attic 6 125 ft' Attic 35 ft' Default Leakage A/H (Default) (Default) 1 1 TEMPERATURES Programablje hermostaf[t:IY ((�� Heating i Jan l l Feb [)q Mar Venting (]Jan I 1 Feb [x) Mar Ceiling Fans: Apr[X� f[[ JIJ rX� [ ] Apr May Jun [ ]Jul lXl Aug [ ]Sep L J OctX Nov Jun l 1 Jul [ 1 Aug I) Sep lxl Dec rr [ Dec 11/20/2019 8:24 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 76 78 78 78 78 78 78 78 70 78 Heating (WD) AM 66 66 66 66 66 68 fib 66 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 65 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbslsq.ft. 0 ft- 0 It 0.3 Dining Default(8 lba/sq.ft. ft' It 0.3 IOtchen Default(8 lbs/sq.ft. ft' ft 0.3 M. Bathroom Default(8 lbs/sq.ft. ft' ft 0.3 WIC De%ult(8lbs/sq.ft. ft' ft 0.3 Master Bedroom Default(8 lbsrsq.ft. ft' It 0.3 Living Room Default(8 lbs/sq.ft. ft' ft 0.3 Foyer Default(8 lbelsq.ft. ft' ft 0.3 Laundry Default(8 lbs/sq.ft. ft' It 0.3 Bedroom 3 Default(B lbs/sq.ft. ft' ft 0.3 Bathroom Defautt(B lbs/sq.ft. ft' ft 0.3 Bedroom 2 Default(8lbs/sq.ft. ft' ft 0.3 A/H Default 8lbs/s .ft. W ft 0.3 Hall 11/20/2019 8:24 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 2017.- AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Bradescu Residence Builder Name: Street: 7605 Roberts Road Permit Office: St. Lucie County City, State, Zip: Fort Pierce, FL, 34951 Permit Number: Y U Owner: loan eratlescu Jurisdiction: St. Lucie County w Design Location: FL, Fort Pierce x U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed In the building envelope. Air -permeable insulation shall requirements The exterlor thermal envelope contains a continuous air barrier. not be used as a sealing material. Bre kG or joints in the air border shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soft shall be aligned with The Insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed, Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be Insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed In substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity Insulation shall be installed to (including Insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity Insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation Installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth In unvented crawl spaces shall be covered with Where provided instead of floor Insulation, insulation a Class I vapor retarderwith overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on Installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on Installation readily conforms to available space shall extend behind pipinci and wirina. Showerltub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be Insulated. Electrical1phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a mannerthat is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between e sprinkler cover plates and walls or ceilinas, a. In addition, inspection of log walls shall be In accordance with the provisions of ICC-400. 11/20/2019 8:24 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX" = 95 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location A/H 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 28.8 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c)Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1282 d) Room uniUPTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.280 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.180 14. Heating system: Capacity 27.0 c) Area 7c. 157.8 a) Split system heat pump HSPF b) Single package heat pump HSPP 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c, a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans Yes a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Address of New Home: 7605 Roberts Road City/FL Zip: Fort Pierce, FL 34951 11/20/2019 8:24:42 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1