HomeMy WebLinkAboutEnergy Code- ;FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR
RECEIVED
DEC 10 2019
BUILDI N
Florida Department of Business and Professional Regulation - Residential Peifiormance Method
Project Name: Bradescu Residence
Builder Name:
Street: 7605 Roberts Road
Permit Office: St. Lucie County
City, State, Zip: Fort Pierce, FL, 34951
Permit Number:
Owner: loan Bradescu
Jurisdiction: St. Lucie County
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types(1232.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block- Ext Insul, Exterior
R=4.1 1048.00 ft'
b. Frame - Wood, Adjacent
R=11.0 184.00 ft'
3. Number of units, if multiple family 1
r,. WA
R= I
4. Number of Bedrooms 3
d. N/A
R= ft'
5. Is this a worst case? No
10. Ceiling Types (1282.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1282.00 ftz
6. Conditioned floor area above grade (ft') 1282
b. N/A
R= ft.
Conditioned floor area below grade (112) 0
c. NIA
R= ft'
11. Ducts
R ft'
7. Windows(157.8 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: A/H
6 125
a. U-Factor: SgI, U=0.28 157.80 ft'
SHGC: SHGC=0.18
b. U-Factor. N/A ft'
12. Cooling systems
kBtufhr Efficiency
SHGC:
a. Central Unit
28.8 SEER:16.00
c. U-Factor: N/A ft'
SHGC: _
13. Heating systems
kBtuthr Efficiency
d. U-Factor: N/A ft'
a. Electric Strip Heal
27.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 1.557 ft.
Area Weighted Average SHGC: 0.180
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (1282.0 sqft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 1282.00 fl'
b. Conservation features
b. WA R= ft'
None
c. WA R= ft'
15. Credits
CF, Pstat
Total Proposed Modified Loads: 44.99
GlasslFloorArea: 0.123
PASS
Total Baseline Loads: 47.11
I hereby certify that the plans and specifications covered by
Review of the plans and
,THE Sr
this calculation are in compliance with the Florida Energy
specifications covered by this
pYOB , • '-_
Code.
calculation indicates compliance
;FOB,
with the Florida Energy Code.
..... -. ;;°.r°�•°;:�3„ �O
PREPA D Y:
Before construction is completed
ui -
DATE:
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
COD WE'(Sz�
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
11/20/2019 8:24 AM EnergyGauge(10 USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Com giant �ajnf: r g f
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: Bredescu Residence
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1282
Lot #
Owner Name: loan Bradescu
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
Plat600k:
Builder Name:
Rotate Angle: 0
Street:
7605 Roberts Road
Permit Office: St. Lucie County
Cross Ventilation: No
County:
St. Lucie
Jurisdiction: St. Lucie County
Whole House Fan: No
City, State,
Zip:
Fort Pierce ,
Family Type: Single-family
FL, 34951
New/Existing: New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1282 10256
SPACES
Number Name
Area Volume kitchen Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1 Dining
117 936 No
2
1
Yes
Yes
Yes
2 i0chen
117 936 Yes
2
1
Yes
Yes
Yes
3 M. Bathroom
54 432 No
0
1
Yes
Yes
Yes
4 WIC
36 288 No
0
1
No
Yes
Yes
5 Master Bedroom
192 1536 No
2
1
1
Yes
Yes
Yes
6 Living Room
264 2112 No
2
1
Yes
Yes
Yes
7 Foyer
65 520 No
0
1
Yes
Yes
Yes
8 Laundry
49 392 No
0
1
No
Yes
Yes
9 Bedroom 3
156 1248 No
1
1
1
Yes
Yes
Yes
10 Bathroom
54 432 No
0
1
Yes
Yes
Yes
11 Bedroom 2
144 1152 No
1
1
1
Yes
Yes
Yes
12 A/H
16 128 No
0
1
No
Yes
Yes
13 Hall
18 144 No
0
1
No
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
Dining 22 R 0
117 ft'
1 0
0
2 Slab -On -Grade Edge Insulatio
kitchen 9 it 0
117 ft'
___
1 0
0
3 Slab -On -Grade Edge Insulatio
M. Bathroom E ft 0
54 ft'
__
1 0
0
4SIab-On-Grade Edge Insulatio
WIC i it 0
36 ft'
____
1 0
0
11/20/2019 8:24 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
5 Slab -On -Grade Edge Insulatio
Master Bedroom 33 it
0
192 ft2
1
0
0
6 Slab -On -Grade Edge Insulatio
Living Room 14 it
0
2041112
__
1
0
0
7 Slab -On -Grade Edge Insulatio
Foyer 5 it
0
65 ft2
1
0
0
8 Slab -On -Grade Edge Insulatio
Laundry 1 it
0
49 ft2
----
1
0
0
9 Slab -On -Grade Edge Insulatio
Bedroom 3 25 ft
0
156 ft2
__
1
0
0
1 Wlab-On-Grade Edge Insulatio
Bathroom E ft
0
54 ft2
1
0
0
11Slab-On-Grade Edge Insulatio
Bedroom 2 11 ft
0
144 ft2
__
1
0
0
12SIab-On-Grade Edge Insulatio
A/H 1 ft
0
16 ft2
1
0
0
13SIab-On-Grade Edge Insulatio
Hall 1 ft
0
18 ft2
__
1
0
0
ROOF
Roof
Gable
Roof
- Red
Solar
SP. Emitt
Emitt Deck.
Pitch
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip
Metal 1389 ft2
0 ft2
Light
N
0.6
No 0.9
No 0
22.6
ATTIC
/
V
# Type
Ventilation
Vent Ratio (1
in)
Area
RBS
IRCC
1 Full attic
Vented
150
1282 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
_
1 Under Attic (Vented)
Dining
30
Batt
117 ft2
0.1
Wood
2 Under Attic (Vented)
Kitchen
30
Batt
117 ft2
0.1
Wood
3 Under Attic (Vented)
M. Bathroom
30
Batt
54 ft2
0.1
Wood
4 Under Attic (Vented)
WIC
30
Batt
36 ft2
0.1
Wood
5 Under Attic (Vented)
Master Bedroom
30
Batt
192 ft2
0.1
Wood
_
6 Under Attic (Vented)
Living Room
30
Batt
264 ft2
0.1
Wood
_
7 Under Attic (Vented)
Foyer
30
Batt
65 ft2
0.1
Wood
8 Under Attic (Vented)
Laundry
30
Batt
49 ft2
0.1
Wood
9 Under Attic (Vented)
Bedroom 3
30
Batt
156 ft2
0.1
Wood
10 Under Attic (Vented)
Bathroom
30
Batt
54 W
0.1
Wood
11 Under Attic (Vented)
Bedroom 2
30
Batt
144 112
0.1
Wood
12 Under Attic (Vented)
A/H
30
Batt
16 ft2
0.1
Wood
13 Under Attic (Vented)
Hall
30
Batt
18 ft2
0.1
Wood
11/20/2019 8:24 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing Solar Below
It
Omt
Tn
Space
Wall Type
_ 1
E
Exterior
Concrete Block - Ext Insul Dining
4.1
9
0
8 0
72.0 ft'
0
0
0.6
0
-2
S
Exterior
Concrete Block - Ext Insul Dining
4.1
13
0
8 0
104.0 ft2
0
0
0.8
0
-3
E
Exterior
Concrete Block - Ext Insul Kitchen
4.1
9
0
8 0
72.0 ft2
0
0
0.6
0
_ 4
E
Exterior
Concrete Block - Ext InM Bathroom
4.1
6
0
8 0
48.0 ft2
0
0
0.6
0
_ 5
N
Exterior
Concrete Block- Ext InMhster Bedro
4.1
15
0
8 0
120.0 ft2
0
0
0.6
0
_ 6
E
Exterior
Concrete Block- Ext lnUbster Bedro
4.1
13
0
8 0
104.0 ft2
0
0
0.6
0
_ 7
W
Exterior
Concrete Block - Ext InNhster Bedro
4.1
5
0
8 0
40.0 ft2
0
0
0.6
0
_ 8
S
Exterior
Concrete Block - Ext InsLiving Room
4.1
14
0
8 0
112.0 ft'
0
0
0.6
0
_ 9
N
Exterior
Concrete Block - Ext Insul Foyer
4.1
5
0
8 0
40.0 ft2
0
0
0.6
0
_ 10
S
Exterior
Concrete Block - Ext InstRedroom 3
4.1
12
0
8 0
96.0 ft2
0
0
0.6
0
11
W
Exterior
Concrete Block - Ext InsLBedroom 3
4.1
13
0
8 0
104.0 ft2
0
0
0.6
0
_ 12
W
Exterior
Concrete Block - Ext InsuBathroom
4.1
6
0
8 0
48.0 ft2
0
0
0.6
0
_ 13
W
Exterior
Concrete Block - Ext Insdiledroom 2
4.1
11
0
8 0
88.0 ft2
0
0
0.6
0
_ 14
N
Garage
Frame -Wood Bedroom 2
11
13
8
104.0 ft2
0
0.23 0.600000 0
_ 15
N
Garage
Frame -Wood Laundry
11
6
8
48.0 ft2
0
0.23 0.600000 0
16
N
Garage
Frame -Wood Foyer
11
4
8
32.0 ft2
0
0.23 0.600000 0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N
Wood Foyer
None
.39
3
6 10
20.5 ft2
WINDOWS
Orientation shown is the entered Proposed orientation.
Wall
Overhang
V
#
Ornt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
E 1
Metal Low-E Single Yes
0.28
0.18
N
15.0 ft2
1 ft 5 in
1 It 4 in
None
None
2
S 2
Metal Low-E Single Yes
0.28
0.18
N
30.0 ft2
1 ft 5 in
1 It 4 in
None
None
3
E 4
Metal Low-E Single Yes
0.28
0.18
N
6.0 ft2
1 ft5 in
1 ft 41n
None
None
4
N 5
Metal Low-E Single Yes
0.28
0.18
N
30.0 ft2
1 ft S in
1 It 4 in
None
None
5
S 8
Metal Low-E Single Yes
0.28
0.18
N
40.8 ft2
2 ft 0 in
1 It 4 in
None
None
6
W 11
Metal Low-E Single Yes
0.28
0.18
N
15.0 ft2
1 ft 5 in
1 It 4 in
None
None
7
W 12
Metal Low-E Single Yes
0.28
0.18
N
6.0 ft2
1 ft 5ln
1 ft 41n
None
None
8
W 13
Metal Low-E Single Yes
0.28
0.18
N
15.0 112
1 ft 5 In
1 ft 41n
None
None
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
380 ft2 380 ft2
21 ft
8 It
11
11/20/2019 8:24 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000356
1196.5 65.69 123.54 .1233 7
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity Block
Duds
1 Electric Strip Heat/
None
COPA 27 kBlu/hr 1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Duds
1 Central Unit/
Split
SEER: 16 28.8 kBlu/hr dm 0.7 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt Conservation
1 Electric None
Garage
0.95 50 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft'
DUCTS
1 —Supply—
t # Location R-Value Area
—Return Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT ON RLF
HVAC#
Heat Cool
1 Attic 6 125 ft'
Attic
35 ft' Default Leakage A/H (Default) (Default)
1 1
TEMPERATURES
Programablje hermostaf[t:IY ((��
Heating i Jan l l Feb [)q Mar
Venting (]Jan I 1 Feb [x) Mar
Ceiling Fans: Apr[X� f[[ JIJ rX� [ ]
Apr May Jun [ ]Jul lXl Aug [ ]Sep L J OctX Nov
Jun l 1 Jul [ 1 Aug I) Sep lxl
Dec
rr
[ Dec
11/20/2019 8:24 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
76
78
78
78
78
78
78
78
70
78
Heating (WD)
AM
66
66
66
66
66
68
fib
66
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
65
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 lbslsq.ft.
0 ft-
0 It
0.3
Dining
Default(8 lba/sq.ft.
ft'
It
0.3
IOtchen
Default(8 lbs/sq.ft.
ft'
ft
0.3
M. Bathroom
Default(8 lbs/sq.ft.
ft'
ft
0.3
WIC
De%ult(8lbs/sq.ft.
ft'
ft
0.3
Master Bedroom
Default(8 lbsrsq.ft.
ft'
It
0.3
Living Room
Default(8 lbs/sq.ft.
ft'
ft
0.3
Foyer
Default(8 lbelsq.ft.
ft'
ft
0.3
Laundry
Default(8 lbs/sq.ft.
ft'
It
0.3
Bedroom 3
Default(B lbs/sq.ft.
ft'
ft
0.3
Bathroom
Defautt(B lbs/sq.ft.
ft'
ft
0.3
Bedroom 2
Default(8lbs/sq.ft.
ft'
ft
0.3
A/H
Default 8lbs/s .ft.
W
ft
0.3
Hall
11/20/2019 8:24 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
2017.- AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Bradescu Residence Builder Name:
Street: 7605 Roberts Road Permit Office: St. Lucie County
City, State, Zip: Fort Pierce, FL, 34951 Permit Number:
Y
U
Owner: loan eratlescu Jurisdiction: St. Lucie County
w
Design Location: FL, Fort Pierce
x
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed In the building envelope.
Air -permeable insulation shall
requirements
The exterlor thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Bre kG or joints in the air border shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soft shall be aligned with
The Insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed,
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be Insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed In substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity Insulation shall be installed to
(including
Insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity Insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation Installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth In unvented crawl spaces shall be covered with
Where provided instead of floor Insulation, insulation
a Class I vapor retarderwith overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
Installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
Installation readily conforms to available space shall
extend behind pipinci and wirina.
Showerltub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be Insulated.
Electrical1phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a mannerthat is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between e sprinkler cover plates and walls or ceilinas,
a. In addition, inspection of log walls shall be In accordance with the provisions of ICC-400.
11/20/2019 8:24 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX" = 95
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
A/H
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
28.8
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c)Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1282
d) Room uniUPTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.280
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.180
14. Heating system: Capacity
27.0
c) Area
7c.
157.8
a) Split system heat pump HSPF
b) Single package heat pump HSPP
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c,
a) Electric resistance EF
0.95
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level a) Ceiling fans Yes
a) Under attic 11 a. 30.0 b) Cross ventilation No
b) Single assembly 11b. c) Whole house fan No
c) Knee walls/skylight walls 11c. d) Multizone cooling credit
d) Radiant barrier installed 11d. No e) Multizone heating credit
f) Programmable thermostat Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder
Address of New Home: 7605 Roberts Road City/FL Zip: Fort Pierce, FL 34951
11/20/2019 8:24:42 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1