WS-12 MANUAL-J
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Jul-14 16:45:48 Rig ht-Su ite® U niv er sal 20 12 12 .1.05 RSU0 2818 Page 1 C:\Users\Jason\Documents\Wrightsoft HVAC\WATERSTONE LOT-12.rup Calc = MJ8 Front Door faces: W Job:Load Short Form Jul 14, 2020Date:Entire House By: Project Information WATERSTONE LOT-12For: ARMINA PL (LOT 12 BLOCK 3), FT. PIERCE, FL 34951 Design Information InfiltrationClgHtg SimplifiedMethod9143Outside db (°F) Semi-tightConstruction quality7570Inside db (°F) 0Fireplaces1627Design TD (°F) L-Daily range 4930Inside humidity (%) 600Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Goodman Mfg.Make Goodman Mfg. Trade GOODMAN, JANITROL, AMANA DISTI...Trade GOODMAN, JANITROL, AMANA DISTI... Model GSZ140301A*Cond GSZ140301A* AHRI ref 4888616 Coil AR*F193116C* AHRI ref 4888616 Efficiency 8.6 HSPF Efficiency 12.0 EER, 14 SEER Heating input Sensible cooling Btuh20160 Heating output Btu h @ 47°F28000 Latent cooling Btuh8640 Temperature rise °F27 Total cooling Btuh28800 Actual air flow cfm960 Actual air flow cfm960 Air flow factor cfm/Btuh0.056 Air flow factor cfm/Btuh0.047 Static pressure in H2O0 Static pressure in H2O0 Space thermostat Load sensible heat ratio 0.68 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) OWNERS SUITE 180 2936 3777 165 179 DINING AREA 123 1189 1145 67 54 GREAT ROOM 287 4486 5794 252 275 BED 2 150 3308 2998 186 142 KITCHEN 184 184 1792 10 85 OS BATH 86 861 439 48 21 OS WIC 51 507 258 28 12 FOYER 74 738 543 41 26 MECH 13 13 381 1 18 HALL BATH 57 802 370 45 18 LAUNDRY 65 250 824 14 39 BEDROOM 3 141 1777 1655 100 79 HALL 29 29 57 2 3 PANTRY 30 29 178 2 8 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Jul-14 16:45:48 Rig ht-Su ite® U niv er sal 20 12 12 .1.05 RSU0 2818 Page 2 C:\Users\Jason\Documents\Wrightsoft HVAC\WATERSTONE LOT-12.rup Calc = MJ8 Front Door faces: W Entire House 1470 17107 20213 960 960 Other equip loads 0 0 Equip. @ 0.95 RSM 19303 Latent cooling 9643 TOTALS 1470 17107 28947 960 960 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Jul-14 16:45:48 Rig ht-Su ite® U niv er sal 20 12 12 .1.05 RSU0 2818 Page 1 C:\Users\Jason\Documents\Wrightsoft HVAC\WATERSTONE LOT-12.rup Calc = MJ8 Front Door faces: W Job:Project Summary Jul 14, 2020Date:Entire House By: Project Information WATERSTONE LOT-12For: ARMINA PL (LOT 12 BLOCK 3), FT. PIERCE, FL 34951 Notes: Design Information Vero Beach Municipal AP, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F43 Outside db °F91 Inside db °F70 Inside db °F75 Design TD °F27 Design TD °F16 Daily range L Relative humidity %49 Moisture difference gr/lb60 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh14771 Structure Btuh16276 Ducts Btuh2337 Ducts Btuh3937 Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0 Humidification Btuh0 Blower Btuh0 Piping Btuh0 Equipment load Btuh17107 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh19303 Method Latent Cooling Equipment Load SizingSimplified Construction quality Semi-tight 0Fireplaces Structure Btuh8590 Ducts Btuh1053 CoolingHeating Central vent (0 cfm)Btuh0 14701470Area (ft²)Equipment latent load Btuh9643 1278812788Volume (ft³) Air changes/hour 0.160.31 Equipment total load Btuh28947 Equiv. AVF (cfm)3466 Req. total capacity at 0.70 SHR ton2.3 Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg.Make Goodman Mfg. Trade GOODMAN, JANITROL, AMANA DISTI...Trade GOODMAN, JANITROL, AMANA DISTI... Model GSZ140301A*Cond GSZ140301A* AHRI ref 4888616 Coil AR*F193116C* AHRI ref 4888616 Efficiency 8.6 HSPF Efficiency 12.0 EER, 14 SEER Heating input Sensible cooling Btuh20160 Heating output Btu h @ 47°F28000 Latent cooling Btuh8640 Temperature rise °F27 Total cooling Btuh28800 Actual air flow cfm960 Actual air flow cfm960 Air flow factor cfm/Btuh0.056 Air flow factor cfm/Btuh0.047 Static pressure in H2O0 Static pressure in H2O0 Space thermostat Load sensible heat ratio 0.68