HomeMy WebLinkAboutPlot PlansEL-SID ENGINEERING, PROFESSIONAL CIVIL ENGINEERS ENGINEERING & CONSTRUCTION MGT. SIDNEY KOVNER, P.E. "No Job Too Small" (561) 3864385 (561) 352-5086 (561) 622-6820 Fax 139 Isle Verde Way elsideng(a comcastnet Palm Beach Gardens, PI, 33418 TMAL DjoAole MEAD CALCL,AT005 Q I ? W " 2f1 M9 FLU, Allow -- 3.0 ' 3-1 ap e 23 vA t1.34 I3•b 601+ aT I00, -- 8,5' 21.3 ►u^n.(^.r,� qi Row = 70 p-r^ Su* oh � 7,1 � < g 75 P-3 F- cc a E O a w0 rU T 00 l Co M M.0 O G ZW W W F W tn Cv� car' lei, vi N L N U. i 7 c Q d �I Q6 a o ���\11 I lil►►, �2 m W u_ O —_y;Z W W W Q y ; ° �Z• Z r~n N• (ZV File COPY IRiE42 O ®R f CODE COMPLIANC ST. LUCIE C T� 030CC 1��I2o7� .91 T rL 0 B - IZZi liprk of repose criteria for .5t. Lucie County only, for pool 5' from house 1) #3 re -steel '@ 6" OC/BW, and 2)'gunite Thickness.- 6" min WATER LINE�- UNDISTURBED OR COMPACTED SOIL M.P0 PROCTOR $TgNOARD 6U MIN. .O500 P51 POOL SECTION 4" 4' CONCRETE 1/4"-3/B" .BRITE #3 0 10 O.C/BW FOR DEPTH TO jr. S3 0 W O.C/BW FOR DEPTH jr- B' — 251 T L DBN BRICK CANTI—LEVER .L19R8 _ CONCRETE w OVER —POUR s WALL SE 5/8" OR BETTER PLYWOOD SHEATHING 2"x 4"x 8' 0 2' O.C. 2------- SHORING - DETAIL R N.T.S. �u DRAIN BRICK 014511M. u,_-. SAN.�4oNcREE. i5Ray_DcK SCREEN ENCI.OAIRE ENOINEEWNO (BY OTHERS) _ iMUM PAVERS 1-0 REBAR CONT. � li' %SVU P51 COM96M , 2500 PSI CONCRETE W/6"x 6" Cf3-t'3 # 10/10 STEEL WE MESH OR FIBER MESH, (11b/':YD.') I�1,• o O—o o� .O—O #3 REBAR U.STNUBED'SOIL 00 i m /T nam \ Po FOOTER.. DETAIL I - 4 1� 012'W/6w( P N ROAR T(T ERV1v o 1ax/Ew (Tv.) xo'armon\ , SWIM IN BENCH DETAIL SWIM OUT BENCH DETAIL NTS NTS HovSr w 00 m 0 0 v a 0® >071 idi SWIMMING POOL PLAN SCALE: I WATER LEVEL 5" MIN. 6„ j 36„ 18„ ANTI-rh9MI PIPE PVC PIPE/ COVER FLEX PIP 1'-MINIMUM STEEL COVER 5"-10"MIN. % PVC PIPING IN GUNITE/ 16T--r III ' ; S3 0 12' - O.C./BW MD.� 6" MIN. SHOTCRETE WALLS / SID KOV , P.E. #16668 FOR POOLS &/OR SPAS I S WIMMI NG P\QA\, PLAN FOR jj\ME5 $ CARLA LAN ! l^ No. 16668 ay rcAV ST STATE OF ; 4l z �L7r-, b •, c P: \��� 0RIO G\\\WO I EL-SID ENGINEERING #EB-0006831 139ISLE VERDE. WAY PALMBEACHGARDENS, FL 33418 a� Y.LLVE 1F' FlLIFA p�Y, 4 w . PUFIP A IWB R lMI S�NFR PIPING SCHEMATIC ms --I M r m me c0 030 m ® m ® :E 0 m 00 1�7 0 .r c0 � 69' TO 2- LED 896BLEaq POOL PIPE SIZE FLOW(ft/sec) :. FLOW THRU 6M P MD GRATES PIPE , - - PIPEFLOW SMAIN KIMMER IN — ZL+ 7.1 6 RETURN TO POOL/SPA__ .Z".._ .. _. %I OO. . ASSUMPTIONS: POOLFLOW 67%MD 33%SKIMMER SPA FLOW 100%MD POOL RETURN �� FROM PUMP, V. FROM TEE, )I-" AF IRWT �-. .-...... ... _ ... PIPING DIAGRAM I :TTO PUMPII , 3—TREAD LADDER N.T.S. HANDRAIL & STEPS (240—SQ.IN. MIN) N.T.S. 2"OuPW .- Po Pool I{''c.O.N.r-rF.__MAG.or_PAVERS Jt 3 FaUJj() )Eg1T 5F"F0 w� I /d x._/8 7_F1Q(ANS qr emuly H/W VAG LACK pW40 FBc zolyyppMC 4gq.41-S3.-L,� ----j- - & ANSI/I(SME A112.19.BM ...�.� SKIMMER & VAC DETAIL �- AfJSI �..aB..� I F6c 3Z GriANNELDR41fNS GiegtTOftleWCOOStillCiroII O�YelT70deIt + � � 1 s h t Y r, •open Area=38.791n' -FlowRate Verified May2011 to CPSC Test Protocol •lAPMO Listed Flow Rates: •Forz.5"plumbing usfng two outerports= 308GPM (Floor) & 212GPM'(Wall) For 2.5" plumbing using cen teY port only= 2000PM (Plo, r) &"168GPM (Wall) -For 211 pluniblriy using two outer ports 2& = 68GPM (Floor) 192GPM (Wolf) �:21_•For2"plumbing using centerport only= No.16668 1 .0 ', STATE OF ; 'U Z i P 'j' XN • �COR\OP' (�� ID KOVN �x'//SSIONAL ?��\\ EUVID 1YR�I KG #EB-0006831 139ISLE VERDE WAY PALM BEACH GARDENS, FL 33418 For DRAWNBY.• SHEET2 OF JOB NO: E #16668 Ina GPM (F/., AR 176GPM (Wnlll NOTES ME OF -TN IOWIN- PCOL SAFrrV : FEATURE OPTLMS MUST HE PROVIDED: I. THE POOL MUST BE:ISCLATTD FROM ACCESS TO A HOME BY AN ENCLOSURE THAT MEETS THE POOL BARRIER REQUIREMENTS OF4M17 OF THE FLORIDA BUILDING CODE -I 2 THE POOL MUST BE'EQUIPPED WITH AN APPROVED SAFETY POOL COVER. A ALL DOORS AND WINDOWS PROVIDING DIRECT ACCESS FROM THE HOME TO THE POOL MUST BE EQUIPPED WITH AN EXIT ALARM THAT HAS A MINIMUM SOUND PRESSURE RATING OF 85db A AT 10 FEET OR; 4. ALL DOORS PROVIDING DIRECT ACCESS FROM THE HOME TO THE POOUMUST'BE EQUIPPED TWTH A SELF- CLOSINO, SELF -LATCHING DEVICE WITH A RELEASE MECHANISM PLACED NO LOWER THAN 54 INCHES ABOVE THE FLOOR ' Mw�t9M FLow. .1VRNOVER T5 GPM p (W RPM1 MINIMU l R'RTRI DraE E b R EAR D- SAND FT�� I O , WIVE ELECTRIC R15ER 01A. 14DOSE PARL it I 70 -� FPL D ,? SP CIFIATIONS: ����N p{LYat, . CtION R10'J 2.1 I. THESE ENGDTEBAING PLA�S C01v67 W�1 t �P-BC 26 7 CC 4yt' .8 PRIVATE SWIMMING POOL FBC 201'-SEC.1trj01, ENGINEERING DESIGN, CONSTRUCTION AND WORKMANSHIP ANSUNSPI -4-92 & NSPI -5. 101.2.1 ANS1/AP.SP-1.5n7 2. GUNITE/ SHOTCRETE / CONCRETE TO ATTAIN 3560 PSI ® 28 DAYS., ....., .. An"J I/ASVC/ ICC - %5,6 3. RE -STEEL TO BE INTERMEDIATE GRADE 40 ASTM 615 STANDARDS, PLACED TO ACT STANDARDS. " 4. PIPING & PLUMBING TO BE SCH, 40 & 80 PVC PIPE TO CONFORM TO NSF STANDARDS & FBC 4.%2.3, 2.13.2'� PURPLE PRIMER APPLIED P RIOR TO ALL GLUE JOINTS FBC PLUMBING SEC. 6.05.21 WATER PLUMBING PRESSURE 35 PSI FOR 15 MINUTES (NO AIR PRESSURE) SEC. 450,2.12.1. 5. ALL RE -STEEL, LITES, LADDERS & HANDRAILS BONDED W / 08 GROUND WIRE TO NEC. # 680-AG141 6. SOILSTATEMEMENT. SWIMMING POOL/SPA/ PATIO- $Zft QW% Pft5S18jW_ y,wu� -,�}Q0 7. POOL / SPA SURROUNDED BY SCREEN ENCLOSURE OR 4' FENCE WITH SELF -CLOSING GATES. ' HOUSE SAFETY BARRIERTO BE "THE BABY" FENCE OR ALARM SYSTEM PER CODE (BY 410 y . 8. POOL / SPA HEATER INSTALLAT ION TO PBC. 2.14.1 HEATER TO HAVE THERMOSTAT AND HIGH PRESSURE CONTROL TO LIMIT WATER TEMPERATURE TO -5104 OF. FBC. SEC. 4$A.2.14.4. ---- 9.. ALL GAS PAPING TO FBC. FUEL GAS SEC. 24.2.25 / ALL ELECTIRCAL TO NEC. It 680.1201 it - 10. AFTER COMPLETION, THE .POOL /.SPA MUST NEVER BE DRAINED BY THE HOME OWNER FOR ANY REASON WHAT -SO- - EVER A LICENSED POOL.CONTRACrOR MUST BE CONSULTED TO ACCOMPLISH THIS. HYDRO STATIC RELIEF VALVE IS USED AT ENGINEER'S DISCRETION ONLY. BACK FLAW PRFV13NTPR ON WATER SERVICE (WPB ONLY 11. THE POOL / SPA -EQUIPMENT SHALL BE SECURED TO A SUBSTANTIAL PAD SO AS TO ELIMNINATE STRAIN ON PIPING. 12. TYPE'O' POOL WALLS VERTICAL WITHIN IT a, DRAINAGE POOL / PATIO TO GRASS (PBC). 13. EL-SID ENGINEERING ASSUMES NO RESPONSIBILITY FOR POOL CONSTRUCTION IN EASEMENTS, OR REQUIRED SETBACK AREAS. THE POOL CONTRACTOR SHALL VERIFY ALL LAYOUT DIMENSIONS IN FIELD WITH HOUSE AND LOT LINES PRIOR TO CONSTRUCTION, ADDITIONALLY, UNDER AND OVER GROUND UTTLTTIPS AT SITE. WATER EDGE SHALL BB TO' MIN. (HORIZONTAL) FROM OVER HEAD ELECTRIC LINES. s 14. THIS ENGINEERING PLAN REMAINS THE SOLE PROPERTY OF EL -SID ENGINEERING AND IS NON -TRANSFERRABLE TO ANYONE WITHOUT EXPRESS PERMISSION OF THIS ENGINEER 15. WARRANTY: THIS ENGINEER WARRENTS THE SERVICES PERFORMED BY EL SID ENGINEERING ARE CONDUCTED IN A MANNER CONSISTENT WITH THAT LEVEL OF CARE AND SKILL ORDINARILY EXERCISED BY MEMBERS OF THIS PROFESSION CURRENTLY PRACTICING UNDER SIMILAR CONDITIONS. NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE MADE. POOLDATA& EQUIPMENT & CRITERIA: POOLDEVIENSIONS I U 17 29 1 AREA 300t". PERIMETER 70/ DEPTH VARIATION !1 S. VOLUME 9 GALLONS SPADIMENSIONS RAISED W / JACUZZI JETS 1°PVC ! 2�4 1►des pig 2p Pump ¢g GR� Cl� 1p.15_ J O PUMP__1_i_BP IV GPM Q. With TTURNOVER RATE '2- FIRS. Ln ES t LED - P001- WATTS HEATER BTU FUEL HANDRAIL bw"/swim -pNgtIN lur-L"Eu DIAMONDBRITB/GEM COAT 3TANDARV) COLOR SLIDE DIVINQ BOARD AUTO -VAC CLEANER iNLiNEcL2ft0TftIQ SHEAR DESCENT WATERFALL LIONS HEAD / ROSETTE PATIO r�Qn'k - MATERIAL PAYERS W/DOD_ Q90FD _ C�fell �..-.I Moro 3 0. Is EQUIPOTENTIAL BONDING GRID NEC 680.26 (c) 20.111 0 -0 ® Q r_ on ICI Alternative Method C per FL Senate Bill SR 2836 0 . ' Executive Order 2007-187 signed June 19, 2007 � F@C Iof.2.lj M ! p Single #8 AWG bare solid copper wire around entire perimeter of pool andconfuted to pool re -steel in 4-equally r spaced places from #8 solid m'sulatedtails and connected w/approvedjmechanical fasteners i.e., split bolt, rade bronze pipe clamp (w/bronze screws) I or concrete deck --� A EQUIPOTENTIAL BONDING ` !' #8 solid ground wire shall be positioned 4" to 6" Into subgrade material of decking adjacent to ' Pool structure.1 This #8 wire shall be bonded to LEDudw. Pool structure rebar in 4 equally spaced points Where decking exist. This 98 wire shall be placed ' 18" to 24" in proximity to pool structural wall. - - Isguy - 1-15mLe AVPO�TRT104 a.IBM 40 PVC BLEAVE SP 10-53 WALL FMITIG-OR EQUAL INUALLEDINSID9FIFE ELECTRICAL DIAGRAM GD AMP POOL PANEL W/ 2947.* $ ' CU WTTm MANUAL MOTOR STARTER SWITCH 11, MIN. ELEC. CONDUIT HP PUMP MOTOR w/BUILT-IN OVERLOAD SWITCH W/ 3 - 012 THEN q8 HOLID CU GROUND WILE CU WITHIN 161" MIN. CONDUIT TO HIGST. PANEL .CT (GFCI PROTEL-12DT TiS.P.S.T. y IME CLOCK ' TOGGLE SWITCH W.P,DISCONNECT 12 VOLT TRANSFORMER POOL LIGHTS (GFI NOT REQUIRED) JUNCTION Box 2. ALL HLECTRICALTOCOMPLY 111MUM111NATIONALELECTRIC CODE. ELECTRICAL CONTRACTOR TO VERITY ADEQUATE CAPACITY AT POINT OF CONNECTION. 2. 3412 TIM CU WITHIN 112" MIN, CONDUIT FOR POOL LIGHT(S), 3. GROUND ALL BOXES, LIGHTS, MOTORS, ETC. w/ 08 SOLID, RARE COPPER. 4. PROVIDE W.P.G.F.L OUTLET WNW, - 20' MAR. FROM WATER'S EDGE, 5. ALL POOL PUMPS TO HE GFCI PROTECTED PAR NEC 680.22(B).`2p1 _- 0 Install in Skimmer. • Uelnoproper¢IzedplaFllcbushlnaa,PoPlBand ribs lnsl¢Ilad In one or the threaded skhnmer outlet pods. Bee •Assembly Preoedme• for proper tlahtenln0 or Peslasnd. 44 0 Install In a return line: Is PoOlDond oan be Installed In the fillrallon return line adjacent to Inlet tlfinD. Avoid Installations that could trap air. • If ¢tees Isrequlad arvicepasa sprinkle slalamvelvebox ran baUsedarsccoa.s.r^ t svI Do Nq YWsll asdloAn � Tlepped ebxD pmedptpelmnEad Wdhwaler QInstall on suction side adjacent to equipment.pad: 17- • Install on BUGIIOR aide pkin;Wa0 al least W tPOIDw water level. • It eoteas Is required for saMco purposes, a apdnkler system valve box oan be used, tmeA• N.s - - a.lo"vAulLnd / 1 BE solid cokD A split Bolt L ' �\\\\IIIII////// No.16668 STATE OF ' U Z i O P• "!,u /;A&:c�ORID`aG\���\� SID EL-SID ENGINEERING #EB-0006831 139 ISLE VERDE WAY ` PALM BEACH GARDENS, FL 33418 For PoalBend Cntln I Inoh Meta Pips Thread i 1i 2019 E E. #1666E Wa �:T.IIn