Loading...
HomeMy WebLinkAboutTruss4451 ST. LUCIE BLVD FORT PIERCE, FL 34946 PH: 772-409-1010 FX: 772-409-1015 www.AlTruss.com I TRUSS,. ENGINEERING I BUILDER: PROJECT - COUNTY: LOT/BLK/MODEL: JOB#: INTEG-CRETE CONST %J �m6 PERCY BARN 0 m 0FRO:E 0 rn ST LUCIE ®� PERCY BARN z z tn m 73155 MASTER#: B51713 OPTIONS: NO OPTIONS �lljr uRAWING /SUBMITTAL RE AP OVED El APPROVEDAS NOTED REVISE AND RESUBMIT EJREJECTED IBMITTAL WAS REVIEWED FOR DESIGN CONFORM NERAL CONFORMANCE TO CONTRnrr nnri INK Architectonic fnc. Fort Pierce, FL 34950 MASTER#: B51713 OPTIONS: NO OPTIONS �lljr uRAWING /SUBMITTAL RE AP OVED El APPROVEDAS NOTED REVISE AND RESUBMIT EJREJECTED IBMITTAL WAS REVIEWED FOR DESIGN CONFORM NERAL CONFORMANCE TO CONTRnrr nnri INK Architectonic fnc. Fort Pierce, FL 34950 A-1 ROOF -TRUSSES AFLORIDACORPORATION RE: Job 73155 Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3 These truss designs rely on lumber values established by others. Site Information: Customer Info: INTEG-CRETE CONSTRUCTION, LLC Project Name: PERCY BARN Lot/Block: Model: PERCY BARN Address: 11298 MULLER RD FORT PIERCE, FL 34945Ddivision: City: County: St Lucie A-1 Roof Trusses 4451 St Lucie Blvd Fort Pierce, FL 34946 State: FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Cade: FBC2017/TPI2014 Design Program: MiTek 20/20 8.1 Wind Code: ASCE 7-10 Wind Speed: 160 Roof Load: 55.0 psf Floor Load: 0.0 psf This package Includes -124 individual, dated Truss Design Drawings and 16 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003,section 5 of the Florida Board of Professional Engineers Rules. No. Seal # Truss Name Date No. Seal # Truss Name Date No. Seal # Truss Name Date 1 A0157096 A01 IOh1/18 13 STDL03 STD. DETAIL 10111/18 25 STDL15 STD. DETAIL 10/11118 2 A0157097 A02 10111118 14 STDL04 STD. DETAIL 10/11/18 26 STDL16 STD. DETAIL 10111/18 3 A0157100 A05G 10/11/18 15 STDL05 STD. DETAIL 10/11/18 4 A0157098 A03 10111/18 16 STDL06 STD. DETAIL 10/11/18 5 A0157099 A04 10111118 17 STDL07 STD. DETAIL 10/11/18 6 A0157101 CA 10111118 18 STDL08 STD. DETAIL 10/11118 7 A0157102 CJ3 10/11/18 19 STDL09 STD. DETAIL 10/11/18 8 A0157103 CJ5 10/11/18 20 STDL10 STD. DETAIL 10/11/18 9 A0157104 HJ7 10/11/18 21 STDL11 STD. DETAIL 10/11/18 10 A0157105 J7 10/11/18 22 STDL12 STD. DETAIL 10/11/18 11 STDL01 STD. DETAIL 10/11/18 23 STDL13 STD. DETAIL 10/11/18 12 STDL02 STD. DETAIL 10/11/18 124 1 STDL14 I STD. DETAIL 10/11/18 The truss drawing(s) referenced have been prepared by MiTek Industries, Inc. under my direct supervision based on the oammelers Drovided by A-1 RoofTmsses. Ltd. Truss Design Engineer's Name: Anthony Tombo III My license renewal date for the state of Florida is February 28,2019. NOTE -.The seal on these drawings indicate acceptance of professional engineering responsibility solelyfor the truss components shown. The suitability and use of components for any particular building Is the responsibility of the building designer, perANSIITPI4 Sec. 2. The Truss Design Drawing(s)(T)DIs]) referenced have been prepared based on the construction documents (also referred to at times as 'Structural Engineering Documental provided by the Building Designer indicating the nature and character of the work. The design criteria therein have been transferred to Anthony Tombo III PE by [At Roof Trusses or specific location]. These TDDs (also referred to at times as 'Structural Engineering Documental are specialty structural component designs and may be part of the project's deferred or phased submittals. As a Truss Design Engineer (i.e., Specialty Engineer), the seal here and on the TDD represents an acceptance of professional Anthony engineering responsibility for the design ofthe single Truss depicted on the TDD only. The Building Designer Is responsible for and shall coordinate and review the TODs for compatibility with their written engineering requirements. Please review all TDDs and all related notes. This item has been electronically signed and sealed by Mlhony combo Ill. P.E. on 10111118 using a digital signaWre. Printed ooples of thlsdocument are not considered signed and sealed. The signaWre must be vented on any electronic copies. Ito P.E. SERIAL #-. 4d36b989999e20a51b6cde8e Page 1 of 1 Job Truss Truss Type Oty Ply , AO157096 73155 A01 Common 8 1 Joh Reference(ootionah A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com 0 Run: 8.210s May 182018 Print: 8.210 s May 182018 MIek 4.00 12 US II Inc. Thu Oct 11 13:59:07 2018 Dead Load Dee. =1/41n 3x4 = 416 = 3x4 = 3xe = 3z8 = LOADING(psf) SPACING- 2-M TCLL 30.0 Plate Grp DOL 1.25 TCDL 15.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress [nor YES BCDL 10.0 Code FBC2017/rP12014 LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-2-0 oc pudins. BOTCHORD Rigid ceiling directly applied or 6-0-12 oc bracing. MiTek recommends that Stabilizers and required cross bracing be Installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1834/0-8-0 (min. 0-2-3) 8 = 1834/0-8-0 (min. 0-2-3) Max Horz 2 = -85(LC 17) Max Uplift 2 = 401(LC 8) 8 = 401(LC 9) Max Grav 2 = 1834(LC 1) 8 = 1834(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3932/1663, 34=3416/1450, 4-5=-3302/1468, 5-6=3302/1468, 6-7=-3416/1450, 7-8=3932/1663 BOT CHORD 2-12=-141913646, 12-19=-831/2429, 11-19=-831/2429, 10-11=-831/2429, 8-10=1444/3646 WEBS 5-10=-384/1057, 7-10=-772/510, 5-12=384/1057. 3-12=-772/510 NOTES- 1) Unbalanced roof live loads have been considered for this design. CSI. DEFL. in (loc) I/defl Ud TC 0.71 Vert(LL) -0.3010-12 >999 360 BC 0.70 Vert(CT) -0.5410-12 >666 240 WB 0.40 Horz(CT) 0.12 8 n/a n/a Matrix -MS 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=24ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 401 lb uplift at joint 2 and 401 lb uplift at joint 8. LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight:1291b FT=10% arcl�n,eaao.�h,,,..m•1.1 mula�m¢(soartcmulnush[aamu6rmmM<'wm'lum�n[IIuaP� Imrytr�w.pmd.tam.m,tm.msa,+gla[Immtrmrt.Imnr:rirm,m,uxlr:„m ww�mpnmr3ee,me..y dnnmarlhxmdmmdmbmma�m[.eau.�wp�..N.Lm.AIq„Kmva.nmrmrameapnprpamdgsmq„ymtegmmlmppmuplmssq�emlaoat.rmtnt.ueePemgrahpgoma,vmmq Anthony T.Tomholll,P.E. Am,ddhtmvYmlWblhbmlmmnidb On,,.trdmYrbPd,glemkYapMip.ahuapdb V.L4C.ib W b4b'm WML%'g db mdmbenrdYlmtt�Sgbfgpup.bn^F..dhaly piYbmpai8tl t8DO83 mMd¢pau¢mudlm9M. mmmamhbmhmlbPmasmlptldvnpbbNgeepafpolfbm.§aDODPmdagamlatlnenmml0pm,Npdan 1m16Re[bnfPm01mma1tlmdbLmvGVpe.lm,In�PFgmmNlmsYad®qub[ 4451 St. WCIe Blvd. ,Oumul,NdlPha4vEged,ph M4,11(dlµglindrtL hinu[Vlly Fghm6101hlddapbgm,uM,rl9aeibedmlmA84Ih,gAlmlaa,mmWml Y11N. � con Pierce,R 34946 0ppIBEI®70111�1Ioo11mm��IlvtlogLiamSem,P.E tepmdrdl000hlisbmmem,uoglmm.irpmh3AlCviaeNtlrnmrapr,mitiorhom A -I ta9Lnso-Avmonri.iamkplA,PL Job Truss Truss Type pty Ply 73155 A02 Hip 2 1 A0157097 Jore b Refence o tional n , nwi uu55c5, ruu rlcl .warn, ae51yr1Lwa mu55.W[[1 t 0 MUn; O.GIU 5 May to LU 10 V nnc O.<Iu a May io zwo M11 eK 4x6 = 4 46 = inc. Inu uct ii l3:owur zuiu Dead Load DeB. = 3116In 3x8 = i.Fut4 11 3x4 = 4x6 = V 1.5x4 II 3x8 = 3x4 = Ig LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Weft L/d PLATES GRIP TCLL 30.0 Plate Gdp DOL 1.25 TC 0.94 Vert(LL) -0.39 12-13 >929 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.72 Vert(CT) -0.6012-13 >597 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.92 Horz(CT) 0.13 7 n/a n/a BCDL 10.0 Code FBC2017/rP12014 Matrix -MS Weight: 135 Ib FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 6-1-15 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with! Installation vide. REACTIONS. (lb/size) 2 = 183410-8-0 (min. 0-2-3) 7 = 1834/0-8-0 (min. 0-2-3) Max Horz 2 = 75(LC 12) Max Uplift 2 = -411(LC 8) 7 = -411(LC 9) Max Grav 2 = 1834(LC 1) 7 = 1834(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-3=-3989/1618, 3-4=-296511258, 4-5=-2741/1245, 5-6=-2965/1258, 6-7=-3989/1618 BOTCHORD 2-13=-1372/3697,12-13=-1372/3697, 11-12>926/2741, 10-11=926/2741, 9-10=-1404/3697, 7-9=-1404/3697 WEBS 3-13=01272, 3-12=11861526, 4-12=-1601511, 5-10=-160/511, 6A 0=1 186/526, 6-9=0/272 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=24ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 411 lb uplift at joint 2 and 411 Ib uplift at Joint 7. LOAD CASE(S) Standard t.,q.rewm�,prmmmttmurlrms(w�muunaotlmamcmtmioo(fna)uncr✓mun•m,a vnryeonro,wmdatlanmwimroum6�wllw,ae.lentl,xmrtrtrm,a5sxu�n.. nanlme.mswl.e,loo..y mnm.core,srmNnnmmtoonN,x4.rlauruN<ro[V5u0,.L..rrWS�rnm,wnnmonP,emavwa+dmvtlnnmrw',Mupownunmminpamlmmm�eyrus.n,monlr.atlnl.mi,pe„anuwnmmler.,,msob Anthony T. TwIto 111, P.E. d,utl6r/mSkelrJGihbrtlWiWa!ON N mOmtxeetl ,aq4.b wo, ¢e..mM14tlb81.mL' W,v,W htT'c,,¢i V.1.IDWmItld, or n!'m dblutL+Y91mf4 m9,.hA0Snefxl� d�bhtt'01ld 380083 bbYghryvd(eONo. N�xsulwl�6WtlbFrtn,tl(•ddrldm6ligfura941ry. MavGe'W"Vae M maw mMvmllo rmtl Peet. on 44515t. Lucie Blvd. Ix..lurdmk.usmgmav1MTNrrrer.N,m.1 or. It, 4 mhOUNtaegNT'.1.nsm.It,.do,bret lLytl.dMnwOidatl5lltl. Fort Pierce, FL 34946 ipil IDItRI LolBvsset-A.Ilovyi.i.mt.11[.P.L lepmlvoiovvl4ild.mmeN,i.aeylve,ispl.hih'mdrilE.mill.rinevpelmisuwh.mA-11.o(inna�A.%myl.l.ml.114rt Job Truss Truss Type Oty Ply , 73155 A03 Hip 2 1 A015i098 Job Reference (optional) A-1 Root Trusses, Fort Pierce, FL 34946, design@a1bussAom Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 Mil 6x6 = 6x8 = Inc. Thu Oct 11 13:59:08 2018 Dead Load Defl. = 5116 in 3x8 = 3x8 = 4x6 _ 3x4 = 3.8 = LOADING(psf) SPACING- 2-" CSI. DEFL. in (loc) Well L/d TCLL 30.0 Plate Grip DOL 1.25 TC 0.90 Vert(LL) -0.30 9-17 >999 360 TCOL 15.0 Lumber DOL 1.25 BC 0.74 Vert(CT) -0.68 9-17 >526 240 BCLL 0.0 • Rep Stress Incr YES WB 0.36 Horz(CT) 0.13 7 n/a n/a BCDL 10.0 Code FBC2017frP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP No.2 *Except' T2: 2x6 SP No.2 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 1-10-4 oc puriins. BOTCHORD Rigid ceiling directly applied or 6-1-2 oc bracing. WEBS 1 Row at midpt 5-11 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, In accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1834/0-8-0 (min. 0-2-3) 7 = 1834/0-8-0 (min. 0-2-3) Max Horz 2 = 65(LC 16) Max Uplift 2 = 421(LC 8) 7 = 421(LC 9) Max Gram 2 = 1834(LC 1) 7 = 1834(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-3=-3973/1648, 34=3321/1344, 4-5=-3104/1322, 5-6=-3319/1344, 6-7=-397211648 BOTCHORD 2-11=-1405/3695, 10-11=-1047/3102, 9-10=-104713102, 7-9=-1436/3695 WEBS 3-11=-681/433,4-11=-90/501, 5-11=-282/285, 5-9=-95/501, 6-9=-682/433 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psh, BCDL=5.Opsf; h=24ft; Cat. 11; Exp B; Encl., GCpl=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 pat bottom chord live load nonconcurrent with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 421 lb uplift at joint 2 and 421 lb uplift at joint 7. LOAD CASE(S) Standard PLATES MT20 GRIP 244/190 Weight:141lb FT=10% Y.N'M1n<lmrgNlmwm'lllx(ilffiajiNfljf�IllltWtl[p®IIIC16061ptl(LLAe'I enpNai�fRh¢IeYl4tlppea,YfdnloMomrinukv¢pM111W,,dbllsllizA4rLldvm4WM mFJnfderly 9LlnbIDr.¢j YOflOmnrlMd6Y�IvbniabK111rlmrlolPYYnN-yeYPl Yi=immlaRlnMnatuvrtpatlm PtlM1e'd^I'w.InrRbmlkmd4tlblY�L,AL9�.blma't.Cf1M.M1b�i' OvRoL.d9�.4�11 MMonY T. T=b80083 Ill, P.E. I d.rdmlmvbn}bbpammpuWatlp Y.m.bOeeh�edgzamb'�1mpa,.bmvdbBr,bM,m164JWrgdrtlWt M1pprrdtlml]4damlmtlblmc MtgbGq mm,YRAe dm�4IDhbrtyatlbrd t88083 bnx.imp*drmrm.lo.ecru.�ubmoanpmarmWbnemmainrnwmwnsa.mn(Im�lauadNmdsm mmn&mind.mahmmra�mp.aannmawmbumnr4n.lmrm,gapuemrm,v�m,r�,.w� rm.mlirdlY��9d4edlL+ipolnnuswmn4 Relmseup Fl,m¢tl0lmlaMgmpn,nlnsssnnnr4n,nderbo9q. WiWmmimmmmltlWbllVi. St. Lucie � (a EIm7011A�i 4dlnsser-Amh LlomidltP.6 le ndodimolairdomme ppp oq p m,mooplormisprol0ded.dheN%a.rilmvperm'suor6oa 1�1ledlmm-Amhvori. tomlo0l,Pl Fort FOR Pierce,R 3494 34946 Job Truss Truss Type pry Ply 73155 A04 Hip 2 1 A0157099 Job Reference o tional n , nwi uuma un nenz, rL Orsvv, uesiyn�w,a iwss.com 4.8 = Run:mzius May is zuiu vrinn a.ziu a May 3a Zulu MIIeK industries, Inc. Inuuctll 1.5x4 II 4x8 = Dead Load Defl. = 114 In 3x8 = 3x4 = US 3x4 = 3x8 = 3x8 = LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (roc) Vdefl Ud TCLL 30.0 Plate Grip DOL 1.25 TC 0.59 Vert(LL) -0.30 12 >999 360 TCDL 15.0 Lumber DOL 1.25 BC 0.65 Vert(CT) -0.55 12 >655 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.36 Horz(CT) 0.13 8 We n/a BCDL 10.0 Code FBC20171TP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP N0.2 *Except* T2: 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-5-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-1-8 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (ID/Size) 2 = 183410-8-0 (min. 0-2-3) 8 = 1834/0-8-0 (min. 0-2-3) Max Horz 2 = -57(LC 9) Max Uplift 2 =-428(LC 8) 8 =-428(LC 9) Max Grav 2 = 1834(LC 1) 8 = 1834(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-4067/1643, 3-4=-3588/1420, 4-5=4059/1677, 5-6=4059/1677, 6-7=3588/1420, 7-8=406711643 BOTCHORD 2-13=141113790, 12-13=1 135/337 1. 11-12=1152/3371, 10-11=115213371, 8-10=-1442/3790 WEBS 3-13=492/326, 4-13=59/415, 4-12=-3471947, 5-12=-617/349, 6-12=-347/947, 6-10=59/415, 7-10=492/325 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=24ft; Cat. II; Exp B; Encl., GCpl=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) This truss has been designed for a 10.0 pat bottom chord live load nonconcument with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 428 Ib uplift at joint 2 and 428 lb uplift at joint 8. LOAD CASE(S) Standard PLATES GRIP MT20 2441190 Weight: 140 lb FT=10% totl,phyYa,glhmYrb'dl NGill�uflntule4u(19Y1tN6111G6[0.10Yj10.a}l(IlttileNllPYiv letlthmppomntl�dvlrcvM1�lmtCepRmypWidb4Avt1 Wv0.r21ehcn9vtKnm9,bt@evly OeJmklGO.aj WeYmvvmnYrttmflbmlbblMYY,rid.l�alm�Gnlplvpully.Spnvtllbyvq,OeWnvllCl npmKKvv¢ttmaJW polmbvl5gmreq,gvtlOrytrNMyv9bteJvinsslgimrveblWv�p.mlvUL Lvbupnvapnm,L3gmMn�,uuJM{ Anthony T. Tornbe 111, P.E. tlmvvlhlmtYgkYg6bsGadbPaw.hO.mivNattl4dv6vbYvi GnC+.YhmOVtlb YIbCdQt YibY4v4dIM1LIbYYvmtlbIDlda6Yu�dLlmcYffi9Udgr+n166ik1dndtrWiJ9hbmPWlld 380083 bbYglv{mdlmvm. avbmmvbIILtlblmmidpmlm�6 W l�vmrlwmm'�Ardvn.0appvudhW dIW mmvmEmryxP�lhl trEmL•mprslfr �efMvfOaMtM9PvlmtMpapmellnu dslaavv,vkn 4451LYFBlvd. vlvaluidntlllvLIDmgdgmYMNIbdIIVMBNM Iklnuh:¢FgLnp101b YLgpe:ga,rtlmsSryvY(vll�vdo1M00q N9dvdkovtmlda9mlM11. FOt Nence,L 34946 Lppi1N®lpll Ml laAlnsses-Awlavyl.lvmAllll P.E lepmdvmov d8isdvometl,ivvrylvim,ivpivGlnedxiMvntivxnoevpemiftieetrvm A -I kdltnus-Av2vvyi.ivmly N, PL Job Truss Truss Type Oty Ply 73155 A05G HIP GIRDER 2 A01527100 Job Reference o tlonal A-1 Hoot Trusses, Fort Plerce, FL 34946, deslgnLaltnAss.com 052 8.210 s May 18 2018 MITek Industries, Inc. Thu Oct 11 14:44:27 2018 Dead Lead Deal. = 51161n a l� " 25 26 " 27 28 11 29 30 31 ' 3.8 = 2x4 II 48 = 5x10 MT20HS= 2x4 II 3x8 = 4x4 = LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (too) I/deb L/d TCLL 30.0 Plate Grip DOL 1.25 TC 0.84 Vert(LL) -0.38 10-12 >958 360 TCDL 15.0 Lumber DOL 1.25 BC 0.40 Vert(CT) -0.70 10-12 >514 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.62 Horz(CT) 0.10 7 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matdx-MS LUMBER - TOP CHORD 2x4 SP M 30 SOT CHORD 2x6 SP 240OF 2.0E WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 3-7-11 oc pudins. BOT CHORD Rigid ceiling directly applied or 10-M oc bracing REACTIONS. (lb/size) 2 = 3371/0-8-0 (min. 0-1-8) 7 = 3371/0-8-0 (min. 0-1-8) Max Horz 2 = 50(LC 4) Max Uplift 2 = -685(LC 4) 7 = -685(LC 5) Max Gray 2 = 3371(LC 1) 7 = 3371(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 23=-8932/1554, 3-1 8=-1 1190/2026, 18-19=11190/2026, 4-19=-11190/2026, 4-20=1119012026, 20-21=-11190/2026. 21-22=-11190/2026, 5-22=1119012026, 5-23=-1126812042, 23-24=1126812042, 6-24=1126812042. 6-7=8918/1551 BOTCHORD 2-13=-1419/8392, 13-25=-1411/8428, 25-26=1411/8428, 12-26=1411/8428, 12-27=1949/11268, 27-28=-1949/11268, 11 -28=-1 949/11268, 11-29=-1949111268, 10-29=1949/11268. 10-30=138018412, 30-31=1380/8412, 931=1380/8412, 7-9=-1388/8378 WEBS 3-13=0/676, 3-12=59913157, 4-12=-9701363, 5-10=-9751363, 6-10=-620/3257, 6-9=0/652 NOTES- 1) 2-ply truss to be connected together with IOd (0.131"x3") nails as follows: Top chords connected as follows: 2x4 -1 row at 0-7-0 Do. Bottomchords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 -1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind; ASCE 7-10; Vult-160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=24ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water pending. 6) All plates are MT20 plates unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 685 lb uplift at joint 2 and 685 lb uplift at joint 7. PLATES GRIP MT20 244/190 MT20HS 187/143 Weight:315lb FT=10% 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 489 lb down and 289lb up at 7-0-0, 169 Ib down and 118 lb up at 9-0-12, 169 lb down and 118 lb up at 11-0-12 , 169 lb down and 118 lb up at 13-0-12, 1691b down and 118 lb up at 15-0-0, 169 Ile down and 118 lb up at 16-11-4, 169 lb down and 118 lb up at 18-11-4, and 169 lb down and 118 lb up at 20-11-4, and 489 lb down and 289 lb up at 23-0-0 on top chord, and 281 Ib down at 7-0-0, 90 lb down at 9-0-12, 90 lb down at 11-0-12, 90 lb down at 13-0-12, 90 Ib down at 15-0-0, 90 lb down at 16-11-4. 90 lb down at 18-11-4, and 90 lb down at 20-11-4, and 281 Ib down at 22.11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-90, 3-6=-90, 6-8=90, 2-7=20 Concentrated Loads (lb) Vert: 3=-419(B) 6=-419(B) 13=-263(B) 9=-263(B) 18=169(B) 19=169(B) 20=-169(B) 21=-169(B) 22=169(B) 23=169(13) 24=-169(B) 25=-75(B) 26=75(B) 27=-75(B) 28=-75(8) 29=75(B) 30=-75(B) 31=-75(B) emax.leu+myW�mv.bvanprmm�lcolrlmnulaasYcecmammlpx(wrclX[ocn[l:Xun'em 1.haaPwwmmmmm,.mlm,w.pm,rcvOw;mm+mrl.rmr,Rltmw,amkt.M mw,am.mmammma.my mom cx,Xaraabmdrmlaaa,aie.rm,emp[gwpv,yoc7nr®rm,wmmma,gmmamlmamn+mvma.mw.qmbvvro-ma>Qatrwp,u,ssymmmm„p.wml.navPw,p m.ddymmn,,mea1 AnthonyT. Tomho It[, P.E. ' mmamlm,mmrwlxmmm,nmreamm,mo.w•,.aeat.mxmXomy.,.amavamecmu.smbdxmgmmmimynNammpmatrvmamrmaesa4hrymyammrnms�nsna,vyosr,a z80083 mbXgpnlsimleMm. Nmm,Ew.minmblimvsmlrelJu,tlmpJYynrymm Wirkvmeoe(IM,ryNrhlplgmnn,uMnmlm�,NPa�m II41LAvsbuymJYa„ppAbamLrt,R,yrt,lm,luTep„neNfm[YxMa,5e4n CnIVIJudwofe6Y,p,tl,peevAWlhalpM eN,LL 11r1nss0.11yfquml,XplblYMmpBneon,elnm Sryb FwbuamlMiffiq IpoFCvdme,umMutlbll4l. 4451r Lucie Blvd. �[vppi'k01pIlMI[vdheves-AmlavpCivmhe N, Pi tepmdeaivvd0isdvmmed,iv vglmn,iswdililedmhkdnrmmuv pnmitsivvhamdi [edrmus�AvlXvvpi.ivmkvlll,rL Fort Piero, FL 34946 Job Truss Type Qty Ply 73155 CJ1 TrsnerJack 8 1 A0157101 Job Reference o tional nmth.e.Zhum my t 1 18 2018 MiTek Industries, Inc. Thu Oct 11 13:59:102018 Page 1 LOADING(psf) SPACING- 2-0-0 1 CSI. DEFL. in (too) I/deg L/d TCLL 30.0 Plate Grip DOL 1.25 TC 0.40 Vert(LL) 0.00 5 >999 360 TCDL 15.0 Lumber DOL 1.25 BC 0.06 Vert(CT) 0.00 5 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 2 n/a n/a BCDL 10.0 Code FBC2017/7P12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 0-11-11 oc puriins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = -52/Mechanical 2 = 43310-8-0 (min.0-1-8) 4 = -91/Mechanical Max Horz 2 = 54(LC 8) Max Uplift 3 = -52(LC 1) 2 = -238(LC 8) 4 = -91(LC 1) Max Grav 3 = 42(LC 8) 2 = 433(LC 1) 4 = 68(LC 8) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; 13CDL=5.Opsf; h=24ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 52 lb uplift at joint 3, 238 Ito uplift at joint 2 and 91 lb uplift at joint 4. LOAD CASE(S) Standard 126 PLATES GRIP MT20 244/190 Weight: 6lb FT = 10% emdn.eetmlvetflhtnYxh•umarneo¢(uua15faauwuerowneacwlonnwolmwoY�ernm txn,Y[IPp tl mnve rut o k�u q�nn[tlhAm,rt tm urtltrn.Desxletga al [ ax.l mp n roa y Ypeamtm[IYV[n�MenlhbnpxlenLLllefin[nn�pfgpwlu.btnhlrym.M„MuiluvrMttpnenex¢yaephlN:u�+gyawu9txlmgOetMnt MyidltrsajelmslyWlmh N�xq.tivAl.Ih N[pnnnlntu,YCryntlan; urclNry Anthony T. Tom6o 111, P.E. Nutelb'[Im[hmp NlYmRlvhrtquwhlril4Pnn,hO,mieuEmntlgllxMlnVag�nye,shmtndNld,hR:a1h4m1'aYry[eGmd MI. hgmNtlW00mlutflVntRbtms,NJ,mplm&Bparrye6[9lbtuxtlh¢q YAMbrtywBinftl t80083 ' IbhVgd[gmtlfem,m.IAxprulogYhNneYh4..rmlgndtlhetltleM1dPp Gx.W®Y!try eeevm@Sr)Idl¢Itllr lfltlflanonhhmdhhpmNPdmhn 11el4px[bmyadYPxcefmt[0hlm[Npye.Im[Pn1n [pnrcallnupn,lxxrt,xint 44515t. Wde Blvd. sev.lmmuahetouaeywepnmlghmiwsealrel'ImtrvudumteptntnlmhumvRsvqwv,xtnn5rammNxte.rer*q. ulop�dvdn[mnHmdnml. Fort Pierce, 34946 (vppilA16201EAlbollrozes-AmhonyT.TombellhP.LRepmdodioeollAisdommem,iooeyfolm,isp1o10dedxitOcvlthe xdihvpemissieehdnA-I Revfinnes AnlM1oopL/vmEo111,P.L Job Truss Truss Type Qty Ply A0157102 73155 CJ3 Corner Jack 8 1 Job Reference o 8onal A-1 Roof Trusses, Fort Pierce, FL 34946, design@aitruss.com Run: 8.210 s May 182018 Print: 8.210 s May 18 2018MiTek Industries, 02018 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well L/d PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.40 Ven(LL) -0.00 4-7 >999 360 MT20 2441190 TCDL 15.0 Lumber DOL 1.25 BC 0.08 Vert(CT) -0.01 4-7 >999 240 BCLL 0.0 ' Rep Stress Incr YES We 0.00 Horz(CT) 0.00 2 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP Weight: 12 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-11-11 oc purlins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MITek recommends thattStabilizem and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 78/Mechanical 2 = 409/0-8-0 (min. 0-1-8) 4 = 17/Mechanical Max Horz 2 = 81(LC 8) Max Uplift 3 = -31(LC 12) 2 = -172(LC 8) Max Grav 3 = 78(LC 1) 2 = 409(LC 1) 4 = 45(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=24ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 31 lb uplift at joint 3 and 1721b uplift at joint 2. LOAD CASE(S) Standard Yvm,lLeunv�dg�mnm'I.uoctlmss[srstw}saautlulfArommcurmlloa(Bwaylmuwuwln•a. vxyaaammammdbwnnm�tnnenpa..gPdclb�dun�t.wamrt unmrawi<m.w. wnsam.E�manmlol,mry mlfwuMlara0darnlab ao Minn. Anthony T. Tombo 111, P.E. ' md,mAlblm'a'14inhmiutuWillgelmltbllmlt.Wkr1c1.h=1WL1111m0b, TOW Iftodnrll,lmvmlem'Wir,"IMMmmlrilin Abbn,,vAdevd. ?80083 m1mYaAongmWlorm. WmsrstlWlmlooatlmliolvn�IWtlonlmYW'4mPamLl,pNwemlWllWutmPo@eaSl(InaMmmlaimkpdvsllHlM1oshn4mi8Pnma,RUOLLnsaWn.l,n�onPraAmutllnuYm,lemryakm 44515L Lode Blvd. 1anlmlYaddy.falmgetlgnbMliq MelllMnlN,e4 mlms huy[qunkAmmERamiaugw,nlnusPao6lne„rdmrb3W. ulgwaNMn�nmWdnml. Fort Pierce, EL 34946 � (eppidhl®7dIAA�l lvoflmsses-AmEvvpi. iomAv III, P.L lepmdvGivvvinisddmmem,ivvvlfvrm,ispwdihAedwAEvml6e vn11evpmmissivoM1omkl Hmlinssvo-Anmvvpi.ivmCv111,P.[. Job Truss Truss Type city Ply 73155 CJ5 Corner Jack 8 1 A0157103 Job Reference (optional) A-1 Root Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Thu Oct 11 13:59:11 2018 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) VdeB Lid TCLL 30.0 Plate Grip DOL 1.25 TC 0.40 Vert(L-) 0.03 4-7 >999 360 TCDL 15.0 Lumber DOL 1.25 BC 0.24 Vert(CT) -0.06 4-7 >999 240 BCLL 0.0 Rep Stress lncr YES WB 0.00 Horz(CT) 0.00 3 We n/a BCDL 10.0 Code FBC2017/rP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or4-11-11 oc pudins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 172/Mechanical 2 = 49310-8-0 (min. 0-1-8) 4 = 60/Mechanical Max Horz 2 = 108(LC 8) Max Uplift 3 = -65(LC 12) 2 = -173(LC 8) Max Grav 3 = 172(LC 1) 2 = 493(LC 1) 4 = 88(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psh BCDL=5.Opsf; h=24ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate gdp DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tail by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 65 Ito uplift at joint 3 and 173 lb uplift at joint 2. LOAD CASE(S) Standard PLATES GRIP MT20 2441190 Weight: 18 lb FT=10% eauxnwae,aN,m�.m•A1nOFnman[nRA6aaltlnMf!<omnmucmolfwn'Iwr[cunun•mr. r,h'wawv+wnm,dun.nlrmoKwnv.cr(mwdm�rl.lm�4rlm.�anvmvmv. w���uren:,mamn<ma, y WletmnipM YIDNrdLbnluYNl.I�rlm, mspywN.LwY6 4ur1pgl�OnPmmewiaaGlelMn�blWsenlnVntlaolhrhlnTCO�WInnMMe41W W.abAL RlnPemlrr.hvgoNe4val9q Anthony T.T01nbo III, P.E. dodb Nlft lndmbLmdN"Wft A04 S80083 N WYgleyz�rm+o..Nvnm.a�N10ld6p�ua�vlptl9mY6rtl6gr,gad Yglloats/gprdNkihlndlwmrdv9fYpiplm Al6lvnN�mmMh�ibeYNLnvkep.Mrbpf¢vdrmslm�¢v1tt I "515L WCIa BIA. onnu4rmhvf�mrrrdvpvn2yhrAPmwYrcl Nlnv Riryrq�nwlbraglap..olnuhvaymlmrWp Nryaiallvemeb`plemt Fort Pierce, FL 34946 fvppipMOl0lAbl belfrvssvt Amlvvpi.iomhvlO,PL teprvdoeimvllhblomoem,mrorloim,ispmbibindd0cmnv.onevpelmusinham Ad ivdinsuo- ArbnyT.TomEom,PL Job Truss Truss Type Qty Ply , A0157104 73155 HJ7 Diagonal Hip Girder 4 1 Job Reference o tional A-1 Roof Trusses, Fort Pierce, FL 34946, design@a1truss.com 3x4 = LOADING(psf) SPACING- 2-0-0 TCLL 30.0 Plate Grip DOL 1.25 TCDL 15.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr NO BCDL 10.0 Code FBC2017/rP12014 LUMBER - TOP CHORD 2x4 SP 240OF 2.0E BOT CHORD 2x6 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 5-7-10 oc pudins. BOTCHORD Rigid ceiling directly applied or 5-3-12 oc bracing. MITek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with,' Installation uide. REACTIONS. (lb/size) 3 = 377/Mechanigl 2 = 801/0-10-15 (min. 0-1-8) 4 = 216/Mechanical Max Horz 2 = 134(LC 4) Max Uplift 3 = -142(LC 8) 2 = -306(LC 4) Max Grav 3 = 377(LC 1) 2 = 801(LC 1) 4 = 248(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=24ft; Cat. II; Exp B; Encl., GCpi=0.18: MWFRS (envelope); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. US 8.210 s Mav 18 2018 MITek Industries. Inc. Thu Oct 11 14:43:57 2018 2.83 12 Cat. DEFL. in (loc) I/deft Ud TC 0.96 Vert(LL) -0.22 4-6 >628 360 BC 0.94 Vert(CT) -0.43 4-6 >270 240 WE 0.00 Horz(CT) -0.00 3 n/a n/a Matrix -MS 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 142 lb uplift at Joint 3 and 306 lb uplift at joint 2. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 41 lb down and 281b up at 4-2-8, 41 It, down and 28 lb up at 4-2-8, and 82 Ito down and 72 It, up at 7-0-7, and 82 lb down and 721b up at 7-0-7 on top chord, and 34 lb down and 80 Ito up at 1-4-8, 34 lb down and 80 lb up at 1-4-8, 23 lb down and 3 lb up at 4-2-8, 23 lb down and 3 It, up at 4-2-8, and 36 lb down at 7-0-7, and 36 Ib down at 7-0-7 on bottom chord. The design/selection of such connection devices) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead +Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-90,2-4=-20 Concentrated Loads (Ib) Vert: 6=86(F=43, B=43) 8=-89(F=-44, B=-44) 9=6(F=3, B=3) 1 0=-64(F=-32, B=32) 10 Defl. = 3116 in 2.5-12 i 1 PLATES GRIP MT20 244/190 Weight: 42lb FT=10% eeQnM1=6�vNh�,m.m•rimnnmsarsw�AsnwuowAmump3mno�rPnoywmn[swrl.=,.Naarw,vam,a.da,s.m„n,ranpwvgAelmtlunw,.l.mviun,�eaMvm.,,. mmsem„mamA.ama„®} Yllekaemlb,fl9NrulhM1,a.Y,tld rsrLni B,cpbpwp,.W�9nr�j,mWv,garnPo,mo®hntlbPl�rNdykvgn4,wY0EIbOrinPitl,Yj,M1urytluM1mA.p.obiM.M1bvpnoge,gYtlqmlv,t�1� Anthony T. Tombo Ill, P.E. dn,Qle,m.,kWr�IhN,nP>�1QM1Oem.hNm'rrbad49.6WGIM4P..bm9eQ0oCNad4WhC9o4tl0.1.Ib4Fl.lYWvr,tlmGJ n,QN,metl6l ka�MeYC0,6ne1bc4J9YbmryOtlfrQ 180083 ' M1dYgM{ndoam.Natims�tll[A rIM1P�mId�iMlMAgrwp25[�1[eom�Ptl,tltlhWdSllln�tivmf6ymtll�r-1e100ub,rymifa,NLisQbMelnirm.,mrbpapvel,nula'ne,ahv 4451 St. Lucie Blvd. • rb�Nl,6tlhr,�v99WeA��n9heI M1Q�M1,mrduprga4nitllr�gdayv.uLmi,caapwim�d4 aq�r�maltel.lrN. Fort Pierce,R. 30946 [vppirbOIDIEA4lvvfhesses-AmEmp6lae5vlll,LE.lepmdvmavvfmisdvmmm,avgfv�aispwilQed�ofvmelxdoevpamisdwhveil WT.... AmEvvpl.Ioedv Ill,Pi Job Truss Truss Type Oty Ply 73155 J7 Jack -Open 18 1 A01571O5 Job Reference (optional) A-3 Roor Trusses, Fort Fierce, FL s4 b, aesign(maltruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MITek Industries. Inc. Thu Oct 11 13:59:12 2018 Pace 1 Dead Load Deft. = 1/8In m V D1 - N 7-f1-0 LOADING(psf) SPACING- 2-" CSI. OEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.93 Vert(LL) 0.13 4-7 >617 360 MT20 2441190 TCDL 15.0 Lumber DOL 1.25 SC 0.59 Vert(CT) -0.26 4-7 >319 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.01 3 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 25 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- LOAD CASE(S) TOP CHORD Standard Structural wood sheathing directly applied. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 259/Mechanical 2 = 593/0-M (min. 0-1-8) 4 = 95/Mechanical Max Horz 2 = 135(LC 8) Max Uplift 3 = -98(LC 12) 2 = -184(LC 8) Max Grav 3 = 259(LC 1) 2 = 593(LC 1) 4 = 130(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.0psf; h=24ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and G-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 3) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 98 lb uplift at joint 3 and 184 lb uplift at joint 2. Y¢p lYwla,�IrmY.m'H roof VgBrUfr6O91tIa0Y[[6GIIL6aSIkYY(IClellfa4tilnLiRMc rng4YppnYmm�eln.mlwMgmwq(R4�am41gt4+A4rtIMmeBenhien¢Otl¢eCewmia.blAl,wy dlfumamnYY509m.u1Lm1]pYb.44lt.tmf W"Eq.im"tlrMOM, Nupmnmm,4C9¢ekbFnhl9ry Anthony T. Tornbm ill• P.E. .d.iede�Im�Y WNUkikmmru�l4lytlbmn¢,m Orvi�.:6Md.g9¢Relnlbppulyn,YbmM1ddm9C11[vIbYWMkolM, rdlRL ibginNdibIDfWn!O�Umdbimu.J,Ggtdfmy+mgr.ImMLmtlfnmpiltllbbngmedgtl 980083 otw'k>qndr I 44515t. Lucie Blvd. .Snk.IdW11.LffNgMgo6.2ghtlrvbvNtlrtt TulmebYpFgm�klpt6lY'lyWpvr,vlmslryR.feOuntlnfbbp NgM¢tlbm¢amltladh1141, Fort Piuce, FL 34946 � fvppid6l®701641Ioaliques�Amdavp7.lvmidld/l4pmG4ivvolaisluvmvl,m4pkim,ispwl0tlediitdvnlhe.nrterpnmisslb6vmb11volinssmAvhev7i.ivmlvl14P1 JANUARY 17, 2017 TYPICAL HIP / KING JACK CONNECTION I STDTL01 A4 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 CORNERSET GENERAL SPECIFICATI MAX LOAD: 55 psf Roof Load, 175 mph, ASCE 7-10, Exp. B, C up to 60' Mean Roof Height and Exposure D up to 30' Mean Roof Height. Attach End Jack's w/ (4) 16d Toe Nails b TC & (3) 16d Toe Nails @ BC CD n Attach King Jack w/ (3) 16d Toe ,Nails @ TC & 24" Strap w/ (6) 10d x 1.5" ea. end @ BC 3ch Corner Jack's (2) 16d Toe Nails ) TC & BC (Typ) Attach Corner Jack's w/ (2) 16d Toe Nails @ TC & BC (Typ) ,MtbwFTT=boM, 0X. "BOOBS 44515t LWO BIr4;.. FbOle{Ce, FL 34946: FEBRUARY 17, 2017 1 ALTERNATE GABLE END BRACING DETAIL 1 STDTL03 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 7724MI010 ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORO 1' - 3' MAX. DIAG. BRACE AT 1/3 POINTS IF NEEDED IT IS THE RESPONSIBILITY OF THE BLDG. DESIGNER OR THE PROJECT ENGINEER/ARCHITECT TO DESIGN THE CEILING DIAPHRAGM AND ITS ATTACHMENT TO THE TRUSSES TO RESIST ALL OUT OF PLANE LOADS THAT MAY RESULT FROM THE BRACING OF THE GABLE ENDS. HORIZONTAL BRACE (SEE SECTION A -A) TRUSSSES 0 24' D.C. 2X6 DIAGONAL BRACE SPACED 48' O.C. ATTACHED TO VERTICAL WITH (4) - 16d NAILS, AND ATTACHED TO BLOCKING WITH (5) - 10d COMMONS. NAIL DIAGONAL BRACE TO PURLIN WITH TWO 16d NAILS. 2X4 PURLIN FASTENED TO FOUR TRUSSES WITH (2) - 16d NAILS EACH. FASTEN PURLIN TO BLOCKING W/ (2) - 16d NAILS (MIN.). ' PROVIDE 2X4 BLOCKING BETWEEN THE TRUSSES SUPPORTING THE \ BRACE AND THE TWO TRUSSES ON \EITHER SIDE AS NOTED. TOENAIL \ BLOCKING TO TRUSSES WITH (2) - \ 10d NAILS AT EACH ENO. ATTACH DIAGONAL BRACE TO BLOCKING WITH (5) - IOd COMMON WIRE NAILS. ENO WALL CEILING SHEATHING BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED: METHOD 1: ATTACH A MATCHING GABLE TRUSS TO THE INSIDE FACE OF THE STRUCTURAL GABLE AND FASTEN PER THE FOLLOWING NAIL SCHEDULE. METHOD 2: ATTACH 2X_ SCABS TO THE FACE OF EACH VERTICAL MEMBER ON THE STRUCTURAL GABLE PER THE FOLLOWING NAILING SCHEDULE. SCABS ARE TO BE OF THE SAME SCAB ALONG SIZE, GRADE, AND SPECIES AS THE TRUSS VERTICALS. VERTICAL NAILING SCHEDULE: - FOR WINO SPEEDS 120 MPH (ASCE 7-98, 02, 05% 150 MPH (ASCE 7-10) OR LESS, NAIL ALL MEMBERS WITH ONE ROW OF 10d (.131' X 3') NAILS SPACED 6' O.C. - FOR WINO SPEEDS GREATER 120 MPH (ASCE 7-98, 021 05), 150 MPH (ASCE 7-10) NAIL ALL MEMBERS WITH TWO ROWS OF 10d C131'X3') NAILS SPACED 6' O.C. (2X4 STUDS MINIMUM). STRUCTURAL GABLE TRUST MAXIMUM STUD LENGTHS ARE LISTED ON PAGE 1. ALI BRACING METHODS SHOWN ON PAGE I ARE VALID AND ARE TO BE FASTENED TO THE SCABS OR VERTICAL STUDS OF THE STANDARD GABLE TRUSS ON THE INTERIOR SIDE OF THE STRUCTURE. NOTE: THIS DETAIL IS TO BE USED ONLY FOR STRUCTURAL GABLES WITH INLAYED / STUDS. TRUSSES WITHOUT INLAYED STUDS ARE NOT ADDRESSED HERE. STANDARD GABLE TRUSS URAL TRUSS oTUO AN ADEQUATE DIAPHRAGM OR OTHER METHOD OF BRACING MUST BE PRESENT TO PROVIDE FULL LATERAL SUPPORT OF THE BOTTOM CHORD TO RESIST ALL OUT OF PLANE LOADS. THE BRACING SHOWN IN THIS DETAIL IS FOR VERTICAL/STUDS ONLY. JULY 17, 2017 STANDARD PIGGYBACK TRUSS STDTL04 CONNECTION DETAIL C' THIS DETAIL IS APPLICABLE FOR THE FOLLOWING WIND CONDITIONS: �I ASCE 7-98, ASCE 7-02, ASCE 7-05, ASCE 7-10 WIND STANDARDS UNDER ALL ENCLOSURE AND EXPOSURE CI CONDITIONS AS LONG AS NO UPLIFT EXCEEDS 377 LBS. REFER TO ACTUAL PIGGYBACK TRUSS DESIGN Ci DRAWING FOR UPLIFTS. NOTE: THIS DETAIL IS VALID FOR ONE PLY TRUSSES SPACED 24' O.C. OR LESS. A-1 ROOF TRUSSES 4451 ST. LUCIE BLVO. FORT PIERCE, FL 34946 772-409-1010 PIGGYBACK TRUSS REFER TO ACTUAL TRUSS DESIGN DRAWING FOR ADDITIONAL PIGGYBACK TRUSS INFORMATION. SPACE PURLINS ACCORDING TO THE MAXIMUM SPACING ON THE TOP CHDRD OF THE BASE TRUSS (SPACING NOT TO EXCEED 24' DL) A PURLIN TO BE LOCATED AT EACH BASE TRUSS JOINT. ATTACH PIGGYBACK TRUSS TO THE BASE TRUSS WITH 2' X 8' TEE -LOCK MULTI -USE CONNECTION PLATES SPACED 48'O.C. PLATES SHALL BE PRESSED INTO THE PIGGYBACK TRUSS AT 48' O.C. STAGGERED FROM EACH FACE AND NAILED TO THE BASE TRUSS WITH FOUR (4) 6d (1.5' X 0.099') NAILS IN EACH PLATE TO ACHIEVE A MAXIMUM UPLIFT CAPACITY OF 377 LSS. AT EACH 2' X 8' TEE -LOCK MULTI -USE CONNECTION PLATE. (MINIMUM OF 2 PLATES) ATTACH EACH PURLIN TO THE TOP CHORD OF THE BASE TRUSS. (PURLINS AND CONNECTION BY OTHERS) BASE TRUSS REFER TO ACTUAL TRUSS DESIGN DRAWING FOR ADDITIONAL BASE TRUSS INFORMATION. Anft"Ti Tm bo III, F.E. tom 4451;SL Lude BNd. Fort metre; FL 349416. JULY 17, 2017 I TRUSSED VALLEY SET DETAIL - SHEATHED I STDTL05 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 VALLEY TRUSS (TYPICAL) SECURE VALLEY TRUSS W/ ONE ROW OF iOd NAILS 6' O.C. GABLE END, COMMON TRUSS, OR GIRDER TRUSS DETAIL A P 12 SEE DETAIL'A' BELOW (T1'P.) GENERAL SPECIFICATIONS: 1. NAIL SIZE =3"X0.131'=10d 2. WOOD SCREW = 4.5' WS45 USP OR EQUIVALENT. 3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES. 4. INSTALL VALLEY TRUSSES (24' O.C. MAXIMUM) AND SECURE TO BASE TRUSSES AS PER DETAIL'A'. 5. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIDUAL DESIGN DRAWINGS. 6. NAILING DONE PER NOS -01. 7. VALLEY STUD SPACING NOT TO EXCEED 48' O.C. BASETRUSSES VALLEYTRUSS (TYPICAL) GABLE END, COMMON TRUSS, OR GIRDER TRUSS TRUSS CRITERIA: WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH WIND DESIGN PER ASCE 7-10: 170 MPH MAX MEAN ROOF HEIGHT = 30 FEET ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12 CATERGORY II BUILDING EXPOSURE WIND DURATION OF LOAD INCREASE: 1.60 MAX TOP CHORD TOTAL LOAD =50 PSF ATTACH 2X4 CONTINUOUS## MAX SPACING =24- O.C. (BASE AND VALLEY) SYP TO THE ROOF W/TWO USP MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. WS45 (1/4' X4.5') WOOD SCREWS INTO EACH BASE TRUSS. AnBwm/.Ti'Tombo M, P.E. ,780083 4451,SL Lode Blvd. FOR Pia j FL ,34946, FEBRUARY 5, 2018 1 TRUSSED VALLEY SET DETAIL I STDTL06 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT. PIERCE, FL 34946 772-409-1010 GABLE END, COMMON TRUSS, OR GIRDER TRUSS GENERAL SPECIFICATIONS: 1. NAIL SIZE=3'X 0.131'=100 2. WOOD SCREW =3' WS3 USP OR EQUIVALENT. 3. INSTALL VALLEY TRUSSES (24- O.C. MAXIMUM) AND SECURE PER DETAIL 'A. i 4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIUAL DESIGN DRAWINGS. S. BASE TRUSS SHALL BE DESIGNED WITH A PURUN SPACING EQUIVALENT TO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING. 6. NAILING DONE PER NDS-01. 7. VALLEY STUD SPACING NOT TO EXCEED 48' O.C. 1j I II �I I i 1 I 11 ii �1 1 11 1 1� BASETRUSSES VALLEY TRUSS (TYPICAL) L 11 VAII 2 SEE DETAIL'A' BELOW (TVP.) EV TRUSS (TYPICAL) GABLE END, COMMON TRUSS, OR GIRDER TRUSS SECURE VALLEY TRUSS W/ ONE ROW OF 10d WIND DESIGN PER ASCE 7-98, ASCE 7-02. ASCE 7-05: 146 MPH NAILS 6' O.C. WIND DESIGN PER ASCE 7-10: 170 MPH MAX MEAN ROOF HEIGHT = 30 FEET ROOF PITCH = MINIMUM 3/12 MAXIMUM 6112 CATERGORY II BUILDING EXPOSURE WIND DURATION OF LOAD INCREASE: 1.60 ATTACH 2X4 CONTINUOUS N2 MAX TOP CHORD TOTAL LOAD = 50 PSF SYP TO THE ROOF W/TWO USP MAX SPACING= 24'O.C.(BASE AND VALLEY) WS3(1/4' X 3') WOOD SCREWS MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. INTO EACH BASE TRUSS. DETAIL A (NO SHEATHING) N.T.S. Anthwq T,Tombo.IB;P.E 9 90083 4151St. Lucie 81v& Fmt.Plerce R. 34945 DULY 17, 2017 1 I` (HIGH WIND VELOCITY) ^(L STDTL07 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772.409-1010 ATTA( WIND DESIGN PER ASCE 7-98, ASCE 7- WIND DESIGN PERASCE 7-10: 170 MPI MAX MEAN ROOF HEIGHT = 30 FEET CATERGORY II BUILDING EXPOSURE B OR C WIND DURATION OF LOAD INCREASE:' MAX TOP CHORD TOTAL LOAD = SO PSI MAX SPACING = 24' O.C. (BASE AND VA SUPPORTING TRUSSES DIRECTLY UNC_.....___ . ...------------- DESIGNED WITH A MAXIMUM UNBRACED LENGTH OF 2' -10° ON AFFECTED TOP CHORDS. NOTES: 1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEY TRUSSES. 2. THIS DETAIL IS NOT APPLICABLE FOR SPF-S SPECIES LUMBER. FOR BEVELED BOTTOM CHORD, CLIP MAY BE APPLIED TO EITHER FACE. NON -BEVELED BOTTOM CHORD CLIP MAY BE APPLIED TO THIS FACE UP TO A MAXIMUM 6/12 PITCH NON -BEVELED BOTTOM CHORD CLIP MUST BE APPLIED TO THIS FACE WHEN PITCH EXCEEDS 6112 (MAXIMUM 12M2 PITCH) i..". or. Y{ AMiwny T`Tombo 111, D,E: 9 80083, 4451:SL.Lude Blvd. rod Rene, R 34946' FEBRUARY 17, 2017 1 STANDARD GABLE END DETAIL 1 STDTL08 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34W 7724094010 * DIAGONAL BRACING REFER TO SECTION A -A TYPICAL 2X4 L-BRACE NAILED TO 2X4 VERTICALS W/IOd NAILS, 6' O.C. VERT STUD SECTION S-B TRUSS GEOMETRY AND CONDITIONS SHOWN ARE FOR ILLUSTRATION ONLY. DIAGONAL BRACE 4' - 0' O.C. MAX. SEE INDIVIDUAL ENGINEERING DRAWINGS FOR TRUSS DESIGN CRITERIA. V Q VARIES TO COMMON TRUSS k* 3X4= v ** L - BRACING REFER TO SECTION B-B 24' MAX. NOTE: 1. MINIMUM GRADE OF #2 MATERIAL IN THE TOP AND BOTTOM CHORDS. 2. CONNECTION BETWEEN BOTTOM CHORD OF GABLE END TRUSS AND WALL TO BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT. 3. BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT BLDG. ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF SYSTEM. 4. L' BRACES SPECIFIED ARE TO BE FULL LENGTH, SPF OR SP #3 OR BETTER WITH ONE ROW OF 10d NAILS SPACED 6' O.C. 5. DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAGM AT 4'-0. O.C. 6. CONSTRUCT HORIZONTAL BRACE CONNECTING A 2X6 AND A 2X4 AS SHOWN WITH 16d NAILS SPACED 6' O.C. HORIZONTAL BRACE TO BE LOCATED AT THE MIDSPAN OF THE LONGEST GABLE STUD. ATTACH TO VERTICAL GABLE STUDS WITH (3) 10d NAILS THROUGH 2X4 (REFER TO SECTION A -A) 7 GABLE STUD DEFLECTION MEETS OR EXCEEEDS L/240 VERTICAL 2X6 SP OR SPF STUDVBRACE #2 DIAGONAL BRACE (4) - 16d NAILS16d NAILS SPACED 6' D.C. (2) lOd NAILS INTO 2X62X6 SP OR SPF #2 2X4 SP OR SPF #2L HORIZONTAL NAILED TO RTICALS SECTION A -A W/(4) - 10d NAILS PRDVIOE 2X4 BLOCKING BETWEEN THE FIRST TWO TRUSSES AS NOTED. TOENAIL BLOCKING TO TRUSSES WITH (2) - 10d NAILS AT EACH ENO. ATTACH DIAGONAL BRACE TO BLOCKING WITH (5) - U]d NAILS (4) Bd NAILS MINIMUM, PLYWOOD SHEATHING TO 2X4 STD SPF BLOCK B. THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES. DIAG. BRACE 9. DO NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPE AT 1/3 POINTS TRUSSES. IF NEEDED 10. 10d AND 16d NAILS ARE 0.131'X3.0' AND 0131'X35' COMMON WIRE NAILS RESPECTIVELY. 11. SOUTHERN PINE LUMBER DESIGN VALUES ARE THOSE EFFECTIVE 06-DI-12 BY SPIB/ALSO. MINIMUM STUD SIZE SPECIES AND GRADE STUD SPACING WITHOUT BRACE 2X4 L - BRACE DIAGONAL BRACE (2) DIAGONAL BRACES AT 1/3 POINTS MAXIMUM STUD LENGTH 2X4 SP 431STUD 12'O.C. 3-8.10 5.6-11 6-6-11 11-1-13 2X4SP#3/STUD 16'0.C. 3-3-10 4-9.12 6-6.11 9.10-15 2X4 SP#31STUO 24'0.C. 2-8-6 3.11-3 54-12 8.1-2 2X4SP#2 12'0.C. 3.10.15 5-6-11 6.6-11 11-8-14, 2X4SP#2 16'O.C. 3.6.11 4-9-12 6-&ll 10-8-0 47 24'0.C. 3-14 3.11-3 6-2-9 9-3-13 DIAGONAL BRACES OVER 6' - 3- REQUIRE A 2X4 T-BRACE ATTACHED TO ONE EDGE DIAGONAL BRACES OVER 12' - 6' REQUIRE 2X4 I -BRACES ATTACHED TO BOTH EDGES. FASTEN T AND I BRACES TO NARROW EDGE OF DIAGONAL BRACE WITH Uld NAILS 6' O.C., WITH 3' MINIMUM END DISTANCE. BRACE MUST COVER SOX OF DIAGONAL LENGTH. T OR I BRACES MUST BE 2X4 SPF #2 OR SP #2. rom ROOF SHEATHING (2) - 10d NAILS "TRUSSES @ 24' OZ. '2X6 DIAGONAL BRACE SPACED 4B' O.C. ATTACHED TO VERTICAL WITH (4) - ISd NAILS, AND ATTACHED TO BLOCKING WITH IS) - 19d NAILS. HORIZONTAL BRACE (SEE SECTION A -A) END WALL MAX MEAN ROOF HEIGHT= 30 FEET EXPOSURE B OR C ASCE 7-10 19D MPH STUD DESIGN IS BASED ON COMPONENTS AND CLADDING. DURATION OF LOAD INCREASE: 1.60 CONNECTION OF BRACING IS BASED ON MWFRS. FEBRUARY17,2017 I WITH 2X BRACE ONLY I STDTL09 NOTES: T-BRACING / I -BRACING TO BE USED WHEN CONTINUOUS LATERAL BRACING IS IMPRACTICAL. T-BRACE / I -BRACE MUST COVER BOX OF WEB LENGTH. THIS DETAIL NOT TO BE USED TO CONVERT T-BRACE / I -BRACE WEBS TO CONTINUOUS LATERAL BRACED WEBS. A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 NAILING PATTERN T-BRACE SIZE NAIL SIZE NAIL SPACING 20 OR 2X6 OR 2XB 10d 6' O.C. NOTE. NAIL ALONG ENTIRE LENGTH OF T-BRACE / ]-BRACE (ON TWO-PLY TRUSSES NAIL TO BOTHPLIES) BRACE SIZE FOR ONE -PLY TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 2X4 20 T-BRACE 2X4 I -BRACE 2X6 2X6 T-BRACE 2X6 I -BRACE 2X8 2XB T-BRACE 2X8 I -BRACE BRACE SIZE FOR TWO-PLY TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 2X4 2X4 T-BRACE 2X4 I -BRACE 2X6 2X6 T-BRACE 2X6 I -BRACE 2XB 2XB T-BRACE, 2XB I -BRACE T-BRACE / I -BRACE MUST BE .SAME SPECIES AND GRADE (OR BETTER) AS WEB MEMBER. NAILS WEB NAILS I -BRACE NAILS WEB T-BRACE SECTION DETAILS FEBRUARY 17, 2017 LATERAL BRACING RECOMMENDATIONS I STDTL10 h1 ROOF TRUSSES 4451 ST. WCIE BLVD. FORT PIERCE, FL 34945 7724D9-1010 TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS, 2XG 'STRONGBACK' IS RECOMMENDED, LOCATED EVERY 8 TO 10 FEET ALONG A FLOOR TRUSS: NOTE 1: 2X6 STRONGBACK ORIENTED VERTICALLY MAY BE POSITIONED DIRECTLY UNDER THE TOP CHORD OR DIRECTLY ABOVE THE BOTTOM CHORD, SECURELY FASTENED TO THE TRUSS USING ANY OF THE METHODS ILLUSTRATED BELOW. NOTE 2: STRONGBACK BRACING ALSO SATISFIES THE LATERAL BRACING REQUIREMENTS FOR THE BOTTOM CHORD OF THE TRUSS WHEN IT IS PLACED ON TOP OF THE BOTTOM CHORD, IS CONTINUOUS FROM ENO TO ENO, CONNECTED WITH A METHOD OTHER THAN METAL FRAMING ANCHOR, AND PROPERLY CONNECTED, BY OTHERS, AT THE ENDS. USE METAL FRAMING ANCHOR TO ATTACH TO TOP CHORD BLOCKING BEHIND THE VERTICAL WEB IS RECOMMENDED WHILE NAILING THE STRONGBACK USE METAL FRAMING ANCHOR TO ATTACH TO BOTTOM CHORD INSERT WOOD SCREW THROUGH OUTSIDE FACE OF CHORD INTO EDGE OF STRONGBACK (DO NOT ATTACH TO VERTICAL ATTACH TO VERTICAL USE DRYWALL TYPE SCREWS) WEB WITH (3) - 10d SCAB WITH (3)- 10d NAILS (0.131' X 3.7 NAILS (0.131' X 3'). ATTACH TO VERTICAL WEB WITH (3) - 10d NAILS (0131' X 3') /ATTACH TO VERTICAL WEB WITH (3) - 10d NAILS (0131' X 3') ATTACH 2X4 VERTICAL TO FACE OF TRUSS. ATTACH TO CHORD FASTEN TO TOP AND WITH (2) N12 X 3' BOTTOM CHORD WITH WOOD SCREWS (2) - 10d NAILS (0.131' (0.216' OIA.) X 3') IN EACH CHORD ATTACH TO VERTICAL SCAB WITH (3) - IOd NAILS (0.131' X 3') /INSERT SCREW THROUGH OUTSIDE FACE OF CHORD INTO EDGE OF STRONGBACK (00 NOT USE DRYWALL TYPE SCREWS) TRUSS 2X6 4' - O' WALL STRONGBACK r (TYPICAL SPLICE) (BY OTHERS) THE STRONGBACKS SHALL BE SECURED AT THEIR ENDS TO AN ADEQUATE SUPPORT, DESIGNED BY OTHERS. IF SPLICING IS NECESSARY, USE A 4' - 0' LONG SCAB CENTERED ON THE SPLICE AND JOINED WITH (12) - 10d NAILS (0131' X 31) EQUALLY SPACED. ALTERNATE METHOD OF SPLICING: OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4' - 0' AND FASTEN WITH (12) - 10d NAILS (0.131' X 3') STAGGERED AND EQUALLY SPACED (TO BE USED ONLY WHEN STRONGBACK IS NOT ALIGNED WITH A VERTICAL). BLOCKING (BY OTHERS) FEBRUARY17,2017 I LATERAL TOE -NAIL DETAIL STDTL11 NOTES: 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45° WITH THE MEMBER AND MUST HAVE FULL WOOD SUPPORT (NAIL MUST BE DRIVEN THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER ENO AS SHOWN). C, 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. A-1 ROOF TRUSSES 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO 4451 ST. LUCIE BLVD. SPECIES FOR MEMBERS OF DIFFERENT SPECIES. FORT PIERCE, FL 34946 772-409-1010 TOE -NAIL SINGLE SHEAR VALUES PER NOS 2001 (LB/NAIL) DIA SP OF HF SPF SPF-S .131 80.0 80.6 69.9 68.4 59.7 U o .135 93.5 85.6 74.2 72.6 63.4 J .162 108.8 99.6 86.4 84.5 73.8 Ni .128 74.2 67.9 5B.9 57.6 50.3 co p .131 75.9 69.5 - "6D.3 59.0 51.1 J n .148 81.4 74.5 64.6 63.2 52.5 ri VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) - 16d NAILS (0162' DIA. X 35') WITH SPF SPECIES BOTTOM CHORD FOR LOAD DURATION INCREASE OF 1.15: 3 (NAILS) X 845 (LB/NAIL) X 115 (DOL) = 2915 LB MAXIMUM CAPACITY ANGLE MAY VARY FROM 30° TO 60• 45.00` ANGLE MAY VARY FROM 30' TO ED* THIS DETAIL IS ONLY APPLICABLE TO THE THREE END DETAILS SHOWN BELOW. SIDE VIEW (2X3) 2 NAILS NEAR SIDE NEAR SIDE SIDE VIEW (2X4) 3 NAILS NEAR SIDE NEAR SIDE NEAR SIDE 45.00° SIDE VIEW (2X3) 2 NAILS NEAR SIDE NEAR SIDE NEAR SIDE NEAR SIDE ANGLE MAY VARY FROM 30' TO 60' 45.00' FEBRUARY 17, 2017 1 UPLIFT TOE -NAIL DETAIL I STDTL12 A-1 ROOF TRUSSES 4461 ST. LUCIE BLVD. FORT PIERCE, FL 34948 772-0094010 THIS DETAIL SHALL BE USED FOR A CONNECTION RESISITING UPLIFT FORCES ONLY. BUILDING DESIGNER IS RESPONSIBLE FOR LOADS IN OTHER DIRECTIONS. NUTES: TOE -NAIL WITHDRAWAL VALUES PER NOS R005 (LB/NAIL) DIA. SP OF HF SPF SPF-S LD .131 59 46 32 30 20 0 .135 60 48 33 30 20 Ill m .162 72 58 39 37 25 J 2 C.0 .128 54 42 28 27 19 I— Z Z .131 55 43 29 28 19 LU .148 62 E 48 34 31 21 J in J N _ Q M Z .120 51 39 27 26 17 (� Z .128 49 38 26 25 17 O .131 51 39 27 26 17 0 .148 57 44 31 28 20 M 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 30' WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE MEMBER ENO AS SHOWN. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE BASED ON THE SPECIE WITH LOWER NAIL CAPACITY BETWEEN THE TWO MEMBERS IN THE CONNECTION. VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) - 16d NAILS (0162' DIA. X 35') WITH SPF SPECIES TOP PLATE FOR WIND DOL OF 1.33: 3 (NAILS) X 37 (LB/NAIL) X 133 (DOL FOR WINO) = 14B LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND FOR WINO DOL OF LED: 3 (NAILS) X 37 (LB/NAIL) X 1.60 (DOL FOR WIND) = 177 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WINO IF THE UPLIFT REACTION SPECIFIED ON THE TRUSS DESIGN DRAWING EXCEEDS 147 LBS (177 LBS) BUILDING DESIGNER 15 RESPONSIBLE TO SPECIFY A DIFFERENT CONNECTION. ire USE (3) TOE -NAILS ON 2X4 BEARING WALL as* USE (4) TOE -NAILS ON 2X6 BEARING WALL NEAR SIDE FAR S. lE TOP PLATE OF WALL 4AIL IAIL SIDE VIEW END VIEW FtBRUARY 5, 2016 TYP 2x2 NAILER ATTACHMENT I STDTLI3 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 1.5 x 4 2x2 NAILER ATTACHMENT GENERAL SPECIFICATIONS MAX LOAD: 55 psf Roof Load, 170 mph, ASCE 7-10, 29'-0" Mean Height, Exp. B, C or D. April 11, 2016 !I TYPICAL ALTERNATE BRACING DETAIL FO EXTERIOR FLAT GIRDER TRUSS STDTL14 A-1 ROOF TRUSSES 4451 ST..LUCIE:BLVD. FORT PIERCE, FL 34948 n2409-1010 (4) 12d TRUSS 2411 O.C. UPLIFT CONNECTION (SEE ROOF TRUSS) EXTERIOR FLAT GIRDER 12 VARIES (4) 12d MAX 3011 (21-611) 2x6 #2 SP (Both Faces) 2411 O.C. SIMPSON H5 stt�lam�pmisoantRmeM+ll7uarlWal',w. luryaww��nYw.a aonu.ubww.4ia�rmwe�tfwsaetwmwswrtn wmnb.uua.mn4.4r mlY,mev(1aaYdb.WmblEaabu'rI n.luv&LDIPWrM RI¢.ibWnRtOE�prmhsvaf Ilbph,Mi�a^M,npPo�lYtbbVYbY�iw NbYnY,IWMfiMY1Ni. bGVWn?Ww+�l�J+4�h MMonY T. TamLIKIbo<BIlll. P.E. ' NwYMlmub lelgYbvycY:n,YbO.aimOMlanevign.bWq&¢i batraEb'YiRWbWbVgILaYQ4l bapeYtlYmdy6tlwYYmgaif;laBgb�.Y9pYs.lagJpbbap.0bltl y.�� I�aq,.mvawNmwb'Hw7?r8nsi bYW,Y.ym4tu YnnNYabPiNb/Wi.Iptl4a1YY1r1d,fMYYgYMYpppld'iMhW.Y9p navtl4YNpbv AlMarvbn9eYnm,albnabmub�pa:igprry�MbmY,pu.e.aYn InetolMaYoulMwP�+�.1.bL.eBu4PPntlImW,tn6e I y4515L vL. YmrmYMy aNuhb*1#.Y.IewEY 4wamYiou ,omolaNl. m F�Plerte, FL 34946 (apP�eb10401i1,IIwiLwbl•lupkYYl.leu6plilpi llPNmtwdM1ilLwawetianrylmgbWod3n:Ivademi6Y�,wpe�umievhw411atlmsnhLLe.p14m6n W,ft I4 2017 STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND FEB6RY 17STDTLI5 DAMAGED OR MISSING CHORD SPLICE PLATES A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 TOTAL NUMBER OF NAILS EACH SIDE OF BREAK + X (INCHES) MAXIMUM FORCE (LBS) 15% LOAD DURATION SP OF SPF HF 2X4 2X6 2X4 2X6 2X4 2X6 2X4 2X6' 2X4 2X6 20 30 24' 1706 2559 1561 2342 1320 1980 1352 2028 26 39 30' 2194 3291 2007 3011 1697 2546 1738 2608 32 48 36' 2681 4022 2454 3681 2074 3111 2125 3187 38 57 42' 3169 4754 2900 4350 2451 3677 2511 3767 44 66 48' 3657 5485 3346 5019 2829 1 243 2B98 4347 DIVIDE EQUALLY FRONT AND BACK ATTACH 2X_ SCAB OF THE SAME SIZE AND GRADE AS THE BROKEN MEMBER TO EACH FACE OF THE TRUSS ( CENTER ON BREAK OR SPLICE) WITH 10d NAILS (TWO ROWS FOR 2X4, THREE ROWS FOR 2X6) SPACED 4' O.C. AS SHOWN (131' OIA. X 3'). STAGGER NAIL SPACING FROM FRONT FACE AND BACK FACE FOR A NET 2' O.C. SPACING IN THE MAIN MEMBER. USE A MIN. 3' MEMBER END DISTANCE. THE LENGTH OF THE BREAK (C) SHALL NOT EXCEED 12'. (C=PLATE LENGTH FOR SPLICE REPAIRS) THE MINIMUM OVERALL SCAB LENGTH REQUIRED (L) IS CALCULATED AS FOLLOWS: L = (2) X + C • 10d NAILS NEAR SIDE + 10d NAILS FAR SIDE BREAK 6' MIN THE LOCATION OF THE BREAK MUST BE GREATER THE REQUIRED X DIMENSION FROM ANY PERIMETER AND A MINIMUM OF S' FROM ANY INTERIOR JOINT 00 NOT USE REPAIR FOR JOINT SPLICES NOTES: 1. THIS REPAIR DETAIL IS TO BE USED ONLY FOR THE APPLICATION SHOWN. THIS REPAIR DOES NOT IMPLY THAT THE REMAINING PORTION OF THE TRUSS IS UNDAMAGED. THE ENTIRE TRUSS SHALL BE INSPECTED TO VERIFY THAT NO FURTHER REPAIRS ARE REQUIRED. WHEN THE REQUIRED REPAIRS ARE PROPERLY APPLIED, THE TRUSS WILL BE CAPABLE OF SUPPORTING THE LOADS INDICATED. 2. ALL MEMBERS MUST BE RETURNED TO THEIR ORIGINAL POSITIONS BEFORE APPLYING REPAIR AND HELD IN PLACE DURING APPLICATION OF REPAIR. 3. THE ENO DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 4. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. 5. THIS REPAIR IS TO BE USED FOR SINGLE PLY TRUSSES IN THE 2X_ ORIENTATION ONLY. 6. THIS REPAIR IS LIMITED TO TRUSSES WITH NO MORE THAN THREE BROKEN MEMBERS. TRUSS CONFIGURATION AND BREAK LOCATIONS FOR ILLUSTRATIONS ONLY THAN OR EQUAL TO BREAK OR HEEL JOINT (SEE SKETCH ABOVE). FEBRUARY 17, 2017 1 SCAB APPLIED OVERHANGS I STDTL16 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34045 772-409.1010 TRUSS CRITERIA: LOADING: 40-10-0-10 DURATION FACTOR: 115 SPACING: 24' O.C. TOP CHORD; 2X4 OR 2X6 PITCH: 4/12 - 12/12 HEEL HEIGHT: STANDARD HEEL UP TO 12' ENERGY HEEL ENO BEARING CONDITION NOTES: 1. ATTACH 2X-SCAB (MINIMUM #2 GRADE SPF, HF, SP, OF) TO ONE FACE OF TRUSS WITH TWO ROWS OF I9d COMMON WIRE NAILS (14B' DIA. X 3') SPACED 6' O.C. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. 2X SC NOTE: TRUSS BUILT WITHOUT AN OVERHANG. THIS DETAIL IS NOT TD BE USED WHEN OVERHANG HAS BEEN BROKEN OFF. ViNwaam THIS DETAIL TO BE USED ONLY WITH TRUSSES (SPANS LESS THAN 40') SPACED 24' O.C. MAXIMUM AND HAVING PITCHES BETWEEN 4/12 AND 12/12 AND TOTAL TOP CHORD LOADS NOT EXCEEDING 50 PSF. TRUSSES NOT FITTING THESE CRITERIA SHOULD BE EXAMINED INDIVIDUALLY.