Loading...
HomeMy WebLinkAboutmetal sales low slope product approvalEVALUATION REPORT OF METAL SALES MANUFACTURING CORPORATION `26 GA. 5V -CRIMP PANEL' FLORIDA BUILDING CODE 6TH EDITION (2017) FLORIDA PRODUCT APPROVAL FL 14645.3-R3 ROOFING METAL ROOFING Prepared For: Metal Sales Manufacturing Corporation 545 South 3rd Street, Suite 200 Louisville, KY 40202 Telephone: (502) 855-4300 Fax: (502)855-4200 Prepared By: Bala SockaLingam, Ph.D., P.E. Florida Professional Engineer #62240 1216 N Lansing Ave., Suite C Tulsa, OK 74106 Telephone: (918) 492-5992 FAX: (866) 366-1543 This report consists of Evaluation Report (3 Pages including cover) °°wamsu Installation Details (1 Page) No 62240 p. � Report No. C2182-3 •. STATE OF <U .pO . P,. Dater 9.9.17 p 10Cy��,t FL 14645.3-R3 C2182-3 9.9.17 Page 2 of 3 Manufacturer: Metal Sales Manufacturing Corporation Product Name: 5V -Crimp Panel Description: 24" wide coverage with (5) 1/2" high ribs Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Deck Description: Min. 19/32" plywood or min. 3/4' thick wood plank (min SG of 0.42) for new and existing constructions. Designed by others and installed as per FBC 2017. Deck Attachment: 8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c. (Minimum) in the field and @ 4" o.c. at edges. Designed as per FBC 2017. New Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1. Required for new construction and optional for reroofing construction. Existing Underlayment: One layer of asphalt shingles over one layer of #30 felt. For reroofing (Optional) construction only. Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2. Requires applied lap sealant for roof slopes less than 3:12. Design Uplift Pressure: 41.6 psf @ fastener spacing of 36" o.c. (Factor of Safety = 2) 74.8 psf @ fastener spacing of 16" o.c. 196.75 psf @ fastener spacing of 8" o.c. Fastener Pattern: Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener shall be of sufficient length to penetrate through the deck a minimum of 3/8". At panel ends @ 6" o.c. across panel width At intermediate @ 12" o.c. across panel width Test Standards: Roof assembly tested in accordance with TAS 125-03 `Standard Requirements for Metal Roofing Systems'. Code Compliance: The product described herein has demonstrated compliance with FBC 2017 Section 1507.4. Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum support spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity FL 14645.3-R3 C2182-3 9.9.17 Page 3 of 3 Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2017 Section 1505 and current approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: TAS 125 Test Reports Farabaugh Engineering and Testing Inc Project No. T181-05, Reporting Date 7/21/05 (Tests #1 & 2) Project No. T240-09, Reporting Date 9/22/09 Architectural Testing, Inc. — West Palm Beach, FL (Formerly Hurricane Test Laboratory, LLC) Project No. 0103-0712-09, Reporting Date 9/1/09 §§§ � ( \ � l : (§ ( ) ) 'd "THd 'MNrrONOOS YM 13NVd MIND—Ag 1 ` , !\§ ® _ 0 f z/ (Z. / ®\+ ' \G§ � 3! / [ c ! ® // 2 : ([7 'd "THd 'MNrrONOOS YM 13NVd MIND—Ag / � \ 1 ` , !\§ ® _ 0 f z/ (Z. / ®\+ ' \G§ � 3! / [ c ! / � \ 1 ` , !\§ ® _ 0 (Z. ®\+ ' ) G! ! ® // 2 ( % /Be p \ RO \ / c