Loading...
HomeMy WebLinkAboutCertification for Design Load CompliancePlanning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: DYER Project Address: 15360 SKY KING DRIVE, PT. SAINT LUCIE, FL 34987 Permit#: Occupancy Type:R-3 Construction Type:55=B INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition - o Any accessory structure requiring a building permit o Any non-residential structure. . Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida BUILDING Code Sixth Edition with 2017 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category:_I X _II _lll_IV Exposure Category:_B X C D 4. Design Wind Velocity170 mph End Zone Width: ft 5. Mean Roof Height 18 ft Roof Pitch: 5 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1:'21.7/-33.5 Zone 2: +21.7/-59.3 Zone 3: +21.7/-88.3 Zone 4: +37.81-39.9 Zone 5: +37.81A9.6 Garage: +31.51-38.1 7. Design Loads: Floor: 2500 PSF Roof/Deaci:25 PSF Roof/Live: 30 Balcony: N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure? X Yes -Not Applicable Explain Why Not 9. Is Continuous Load Path Provided?X Yes_ Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Lilllian Gonzalez Print Name Cent # & Co. Cent Auth. Goarch Engineering, Inc 1824 Richard Ln Palm Sorinos. FL 33406 Company Name & Address F %% 00#4