HomeMy WebLinkAboutBlower Door Tests=+- ice`
�YI n
Hate -1 �zi/ tiotio
Contractor:
Job Address:
Construction:
Planning g: Development Services
Building c Code Regulation Division
2300 Virginia Ave, Rm 201
Fort Pierce, FL 34902
Phone: 772.462-2165 Fa3s 772-462-6443
8H OWCR DOOR TEST FORM
House Infiltration Test Cer41catian
Presei"Ptive and Perf®rmaRce Method
Permit . I oil 0 — 03 —I4
12. __ 1-
--••••..� ��.co�vo9 —L:31 a1p7e4C
) EXIsting —Aicer Additions
House infiltratuon Fest Results
CFM (50) = 12 i Z SLC Clunate Zone 2 F
Volume = a Test Date.-
ACM
ate:ACM (50) = CFM (50) 1160 / volume = -5,-3
Passing results must be c ACH (50) or less Mecanrcal Uenrilaiion required less than 3 ^CH
(,)'[ass { )Fall
FBC, Energy i
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conduced with a
blower door at a pressure of 0.2 inches w, g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(,""), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code offdal. Testing shall be perormed at any time a ler creation of all penetrations of the building
thermal envelope.
FPC. Residential
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
Pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code,
the dwelling unit shall be provided with whole house Energy Conservation
mechanical ventilation in accordance with Section M1507.3.
Testing Compary
Company Name: Pro-DuCt Services
Address: 1915 Rio Vista Drive, Ft. Pierce, FL 34949
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance ith Sectio 11402.4.1.2 Climate %one 2.
Signature:
Printed Name: Malin Klein
License/Certification 4; 6061633