Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WS-LOT-15 ENERGY CALC-1
FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WATERSTONE LOT -15 Builder Name: K. HOVNANIAN Street: TBD Permit Office: ST. LUCIE COUNTY City, Slate, Zip: FT. PIERCE, FL, 34951 Permit Number: Owner: Jurisdiction: .Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1716.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Ext Insul, Exterior R=4.1 1450.20 R' b. Frame - Wood, Adjacent R=11.0 265.78 ft2 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 4 d. N/A R= ft2 10. Ceiling Types (1616.0 sgft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1616.00 ft2 6. Conditioned Floor area above grade (112) 1616 b. N/A R= IF Conditioned floor area below grade (ft') 0 0. N/A R= ft2 11. Ducts R 112 7. Windows(163.6 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 448 a. U -Factor: Dbl, U=0.32 106.11 112 SHGC: SHGC=0.30 b. U -Factor: Dbl, U=0.55 41.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a. Central Unit 28.8 SEER:14.00 c. U -Factor: Dbl, U=0.32 16.44 ft2 SHGC: SHGC=0.27 13. Heating systems kBtu/hr Efficiency it. U -Factor: N/A ft2 a. Electric Heat Pump 28.8 HSPF:8.60 SHGC: Area Weighted Average Overhang Depth: 4.626 ft. Area Weighted Average SHGC: 0.307 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (1616.0 sgft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 1616.00 ft2 b. Conservation features b. N/A R= ft2 None G. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.101 Total Proposed Modified Loads: 54.63 PASS Total Baseline Loads: 57.63 1 hereby certify that the plans and specifications covered by Review of the plans and 4214E Spg7, this calculation are in compliance with the Florida Energy specifications covered by this V0,FOA Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 0 I hereby certify that this building, as designed, is in compliance Florida Statutes. COD with the Florida Energy Code. WE'C4� OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 7/16/2020 4:32 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT 7/16/2020 4:32 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: WATERSTONE LOT -15 User 1 K. HOVNANIAN ST. LUCIE COUNTY Single-family New (From Plans) Bedrooms: 4 Conditioned Area: 1616 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: TBD County: St. Lucie City, State, Zip: FT. PIERCE, FL, 34951 CLIMATE V/ Design Location TMY Site Design Temp 97.5% 2.5% Int Design Temp Healing Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 1616 14059.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 1616 14059.2 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R -Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 167.2 ft 0 1616 ft' ---- 0 0 1 ROOF / V # Type Materials Roof Gable Roof Area Area Color Rad Solar SA Emitt Emilt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1750 ft2 0 ft2 Medium N 0.4 N 0.9 No 0 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1616 IF N N CEILING # Ceiling Type Space R -Value Ins Type Area Framing Frac Truss Type _ 1 Under Attic (Vented) Main 30 Blown 1616 W 41 Wood 7/16/2020 4:32 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM 8405-2017 INPUT SUMMARY CHECKLIST REPORT 7/16/2020 4:32 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below it C)rnt Space To WAI Type p _ n Aron R -\/Ano Frnrrn 1 N Exterior Concrete Block - Ext Insul Main 4.1 52 0 8 8 450.7 ft' 0 0 0.3 0 _ 2 E Exterior Concrete Block- Ext Insul Main 4.1 16 4 8 8 141.6 ft' 0 0 0.3 0 _ 3 S Exterior Concrete Block - Ext Insul Main 4.1 64 0 8 8 554.7 ft' 0 0 0.3 0 4 W Exterior Concrete Block - Ext Insul Main 4.1 35 0 8 8 303.3 W 0 0 0.3 0 5 - Garage Frame - Wood Main 11 30 8 8 8 265.8 112 0 0.25 0.3 0 DOORS # Ornt Door Type Space Storms U -Value Width Height Area Ft In Ft In 1 E Wood Main None .39 3 7 21 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang �/ # Ornt ID Frame Panes NFRC U -Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Double (Clear) Yes 0.32 0.3 N 15.0 It' 1 It 0 in 1 It 0 in None None 2 E 2 Vinyl Double (Clear) Yes 0.32 0.27 N 16.4 ft' 1 it 0 in 1 ft 0 in None None 3 S 3 Vinyl Double (Clear) Yes 0.32 0.3 N 16.4 ft2 1 it 0 in 1 it 0 in None None 4 S 3 Vinyl Double (Clear) Yes 0.55 0.34 N 41.0 fP 10 ft 0 in 1 it 0 in None None 5 W 4 Vinyl Double (Clear) Yes 0.32 0.3 N 49.8 ft2 1 ft 0 in 1 It 0 in None None 6 W 4 Vinyl Double (Clear) Yes 0.32 0.3 N 24.9 ft2 10 it 0 in 1 it 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 380 It 380 ft2 64 it 8 it 1 INFILTRATION # Scope Method SLA CFM 50 FLA EgI-A ACH ACH 50 1 Wholehouse Proposed ACH(50) .000387 1640.2 90.05 169.35 .1387 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.6 28.8 kBtulhr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Por Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 14 28.8 kBtu/hr cfm 0.7 1 Sys#1 7/16/2020 4:32 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM 8405-2017 INPUT SUMMARY CHECKLIST REPORT 7/16/2020 4:32 PM EnergyGauge© USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cori # Company Name System Model # Collector Model # Area Volume FEF None None fl' DUCTS ---Supply--- ---Return--- Air CFM 25 CFM25 HVAC# U # Location R -Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 448 W Attic 212 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Piogramabl(e Thermostat: Calling Fans: Heating EX� Jan �JY Feb r[ Mar Ap,{[Doc I ` J] r Jun IX) Jul IX� ] Aug lXJ I 1 Sep € (rX,� Nov rr H Venting ll Jan llI 111 Feb L 1 [[[IX Mar l� Apr I May ll 11 Jun Il 1111 Jul IX1 E 111 Aug I 1 Sep Od [X] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 fib 66 68 68 68 68 68 68 68 PM 68 68 68 fib 68 68 68 68 68 fib 66 66 MASS Type FD.f.11t(8 Area Thickness Furniture Fraction Space lb./.,.ft. 0 ft2 0 ft 0.3 Main 7/16/2020 4:32 PM EnergyGauge© USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4