Phone: 772-589-0712
C.A.# 5693
KSMengineering.net
DATE TESTED:KSM JOB # :192955-1pd/CH/ct
CONTRACTOR:Ericka Villegas PERMIT #:2001-0383
JOB LOCATION:335 SE Tranquilla Avenue NUC #417
Port St Lucie, Florida Nuc Model:3500
Nuc Serial #:3417
ITEM TESTED :Pool Backfill Compaction
TEST LOCATION
OF SAMPLE DEPTH PEN
READ
DRY
DENSITY
MAX. DRY
PROCTOR VALUE
PERCENT
COMPACTION
1 S.W.0'-1'45 106.9 110.6 96.7%
2 1'-2'45 -"95.0% +
3 2'-3'48 -"95.0% +
4 3'-4'48 -"95.0% +
5 N.W.0'-1'45 107.2 110.6 96.9%
6 1'-2'48 -"95.0% +
7 2'-3'50 -"95.0% +
8 3'-4'50 -"95.0% +
9 S.E.0'-1'43 106.6 110.6 96.4%
10 1'-2'45 -"95.0% +
11 2'-3'45 -"95.0% +
12 3'-4'48 -"95.0% +
Soil Description:
Gray Sand
In Place Moisture:
7.8%
Proctor Optimum Moisture:
12.0%
Proctor Max. Dry Density: P.C.F.
110.6
@ Test Locations the Density &
Penetrometer reading indicate the
Degree of Compaction Meets
Minimum Requirement
for Unplumbed Backfill
Respectfully Submitted:
Bryan E. Dahlke, P.E.
V.P. of Engineering
PE # 81439 7/31/2020
Email to: ericka382000@yahoo.com
SOIL COMPACTION REPORT
ASTM D 1557 and ASTM D 6938
July 30, 2020
Disclaimer:Contractor is responsible to maintain
the pool backfill in the condition that KSM
completed the indicated passed compaction test.
KSM is not responsible if the poolbackfill has been
altered from the approved inspected condition.
Proudly Serving Florida since 1990
107.0
108.0
109.0
110.0
111.0
112.0
9 10 11 12 13 14 15
W
E
I
G
H
T
P
.
C
.
F
.
D
R
Y
Moisture -% of Dry Weight