Loading...
HomeMy WebLinkAbout001-220022_CV-1ABBREVIATIONS AB ANCHOR BOLT MATL MATERIAL A/C AIR CONDITIONING MECH MECHANICAL AFF ABOVE FINISH FLOOR MEMB MEMBRANE ALUM ALUMINUM MTL MEAN TIDE LEVEL APPROX APPROXIMATELY MFC METAL FURRING CHANNEL ARCH ARCHITECTURAL / ARCHITECT MFR MANUFACTURER BD BOARD MIN MINIMUM BLDG BUILDING MIR MIRROR BILK BLOCK MISC MISCELLANEOUS BOT / BOTT BOTTOM MO MASONRY OPENING BRG BEARING MR MOISTURE RESISTANT BTWN BETWEEN MT METAL THRESHOLD CAB CABINET NAT NATURAL CLG / CEIL CEILING NIC NOT IN CONTRACT CEM CEMENT # NUMBER CL CLOSET NOM NOMINAL CLR CLEAR NTS NOT TO SCALE COL COLUMN OA OVERALL / OUTSIDE AIR CONIC CONCRETE OC ON CENTER CONST CONSTRUCTION OPNG OPENING CONT CONTINUOUS OPP OPPOSITE CONTR CONTRACTOR ORIG ORIGINAL CT CERAMIC TILE PART PARTITION CTR CENTER PL PLATE DEG (°) DEGREE PLAS PLASTER DEPT DEPARTMENT PLWD PLYWOOD DTL DETAIL PNL PANEL DF DRINKING FOUNTAIN PNT/ PTD PAINT/ PAINTED DIA DIAMETER POL POLISHED DIM DIMENSION PREFAB PREFABRICATED DIN DOWN PROJ PROJECT DR DOOR PSF POUNDS PER SQUARE FOOT DWG DRAWING PSI POUNDS PER SQUARE INCH EA EACH PT PRESSURE TREATED EL/ELEV ELEVATION PVMT PAVEMENT ELEC ELECTRIC / ELECTRICAL QTY QUANTITY EQ EQUAL REF REFRIGERATOR EQUIV EQUIVALENT READ REQUIRED EQUIP EQUIPMENT REINF REINFORCED / REINFORCING EW EACH WAY RET RETURN EXH EXHAUST REV REVERSE / REVISION EXIST EXISTING RGD RIGID EXT EXTERIOR RM ROOM FD FLOOR DRAIN RO ROUGH OPENING FIN FINISH SCHED SCHEDULE FIX FIXTURE SD SOAP DISPENSER FL FLOOR SEP SEPARATE FLUOR FLUORESCENT SECT SECTION FTG FOOTING SHLF SHELF FURR FURRING SHT SHEET GA GAGE/GAUGE SIM SIMILAR GALV GALVANIZED SPEC SPECIFICATION GL GLASS/GLAZING SPKR SPEAKER GR GRADE SQ SQUARE GYP GYPSUM STD STANDARD HB HOSE BIBB STL STEEL HCP HANDICAP STOR STORAGE HDWR HARDWARE SUB SUBSTITUTE / SUBSTRATE HDWD HARDWOOD SURF SURFACE HGT HEIGHT SUSP SUSPEND/SUSPENDED HIM HOLLOW METAL SYS SYSTEM HR HOUR T&G TONGUE & GROOVE HVAC HEATING / VENTILATING TEL TELEPHONE HW HOT WATER THK THICK / THICKNESS IN INCH TPH TOILET PAPER HOLDER INCAND INCANDESCENT TRANS TRANSFORMER NCL INCLUDE TYP TYP I CAL INFO INFORMATION UGND UNDERGROUND INSUL INSULATE / INSULATION UL UNDERWRITERS LAB. INT INTERIOR VERT VERTICAL KIT KITCHEN W/ WITH LAM LAMINATED WC WATER CLOSET LAV LAVATORY WH WATER HEATER LB / LBS POUND / POUNDS WM WIRE MESH LIN LINEAR W/O WITHOUT LL LIVE LOAD WP WATERPROOF LT LIGHT WS WEATHER STRIPPING LVR LOUVER WWF WELDED WIRE FABRIC SYMBOLS LEGEND r(l� NORTH ARROW PARTITION TYPE TAG NORTH OX WINDOW TYPE TAG X ELEVATION XXX XXX DOOR TYPE TAG CEILING HT. VERTICAL ELEVATION X @ EL. # TAG XXX BUILDING /WALL SECTIONS Ai REVISION TAG x XXX DETAIL XX.XX MATERIAL OR TILT PANEL KEYNOTE ROOM x/ INTERIOR ELEVATIONS NAME XXX ROOM TAG BST ► \ 1/- DRAWING TITLE TITLE 1 SHEET NUMBER SCALE: A-1.Q1 SES UNITE[) TELEPORTS INTERIORIM ROV M NTS 10161 Range Line Road, Port St. Lucie, FL 34987 GENERAL NOTES 1. DO NOT SCALE DRAWINGS TO OBTAIN DIMENSIONS. ANY DIMENSION NOT GIVEN OR MISLABELED SHALL BE CONFIRMED WITH THE ARCHITECT PRIORTO CONSTRUCTION. 2. ANY DISCREPANCIES WITH THE DRAWINGS DIMENSIONS OR OTHERWISE SHALL BE BROUGHTTO THE ARCHITECT'S ATTENTION PRIOR TO PURCHASING OF MATERIALS, PROJECT COMPONENTS AND COMMENCEMENT OF CONSTRUCTION. 3, ALL WORK TO BE PERFORMED UNDER THIS CONTRACT SHALL COMPLY WITH THE CURRENT BUILDING CODE AS STATED ON THE BUILDING CODE SUMMARY IN THESE DOCUMENTS, AS WELL AS ALL CITY ORDINANCES, RULES AND REGULATIONS. ALL WORK SHALL CONFORM TO FLORIDA STATE STATUTES 4. THE CONTRACTOR SHALL FAMILIARIZE THEMSELVES WITH THE CONTRACT DOCUMENTS, AND CONTRACT SUPPLEMENTS RELATIVE TO THE SCOPE OF THE WORK RELATING TO THIS PROJECT, 5, GENERAL CONTRACTOR SHALL CALL 1-800-432-4770 (CALL BEFORE YOU DIG), TWO FULL BUSINESS DAYS BEFORE DIGGING. CONTRACTORSHALL BE RESPONSIBLE FOR ANY DISRUPTION TO ANY UTILITY SERVICES DAMAGED. 6. THE CONTRACTOR SHALL TAKE APPROPRIATE ACTION TO PROVIDE THE NECESSARY PROTECTION OF THE GENERAL PUBLIC AND PREVENT ACCESS TO THE PROJECT SITE. THE CONTRACTOR IS TO SECURE THE SITE WITH ADEQUATE SAFETY MEASURES TO PREVENT ACCESS TO THE PUBLIC OF AREAS UNDER CONSTRUCTION. 7, IT IS RECOGNIZED THAT THE CONTRACT DOCUMENTS DO NOT COVER SOME CONDITIONS OR MODIFICATIONS WHICH MAY BE REQUIRED AND WHICH MAY NOT ACCURATELY REFLECT THE EXISTING CONDITIONS, IT IS HOWEVER, INTENDED THAT THE CONDITIONS NOT DETAILED OR NOT SHOWN ACCURATELY SHALL BE DEVELOPED THOUGH THE TRADE CONTRACTORS VIA SHOP DRAWINGS, REPORTS OR SPECIFICATIONS TO THE SAME LEVEL OR AESTHETICS AND IN COMPLIANCE WITH THE PERFORMANCE CRITERIA AS INDICATED FOR DETAILED AREAS AND STIPULATED IN THESE DOCUMENTS. THE CONTRACTOR, IN THEIR PREPARATION OF THEIR BID, IS TO VISIT THE SITE AND DETERMINE THE EXISTING CONDITIONS FORTHEMSELVES. THE TRADE CONTRACTORS BY ACCEPTING A CONTRACT FOR THE WORK ACKNOWLEDGES THIS AND AGREES THAT THE OWNER AND ARCHITECT SHALL HAVE THE FINAL APPROVAL. 8. ANY SUBSTITUTIONS, REVISIONS, OR ADDITIONS PROPOSED BY THE CONTRACTOR OR THEIR SUB -CONTRACTORS SHALL BE SUBMITTED TO OWNER FOR APPROVAL PRIOR TO IMPLEMENTATION, THE ARCHITECT IS NOT RESPONSIBLE FOR THE TECHNIQUES, MEANS, AND METHODS EMPLOYED BY THE CONTRACTOR OR THEIR SUBCONTRACTORS FOR THE FABRICATION OR INSTALLATION OF ANY SPECIFIED ITEM OR MATERIAL. IT IS THE RESPONSIBILITY OF THE PARTY SUBMITTING THE SUBSTITUTION REQUEST TO RESEARCH AND QUALIFY THAT PERFORMANCE AND CONSTRUCTION SPECIFICATIONS MEET THOSE OF THE ORIGINALLY SPECIFIED ITEM OR MATERIAL PRIOR TO SUBMISSION OF SUBSTITUTIONS TO THE DESIGNER. 9, CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND REPORT ANY CONDITIONS WHICH ARE IN CONFLICT WITH THE DRAWINGS AND SPECIFICATIONS TO ARCHITECT IMMEDIATELY. DO NOT PROCEED WITH CONSTRUCTION UNTIL ALL DISCREPANCIES ARE RESOLVED, ALL CONSTRUCTION SHALL CONFORMTO THE REQUIREMENTS OF ALL GOVERNING FEDERAL, STATE, AND LOCAL BUILDING CODES. 10. DIMENSIONS INDICATED ON THE DIMENSION PLAN ARE TO THE FACE OF STUD OR CONCRETE SUBSTRATE. 11. GENERAL CONTRACTOR SHALL NOTIFY THE ELECTRICAL CONTRACTOR AND/OR OWNER IF CONFLICTS OCCUR BETWEEN LIGHTING AND OTHER TRADES OR BUILDING STRUCTURE. DO NOT PROCEED WITH INSTALLATION IN THAT AREA UNTIL CONFLICT HAS BEEN RESOLVED TO THE SATISFACTION OF THE OWNER AND CONTRACTOR, 12. NOTIFY THE OWNER IMMEDIATELY IF THE REMOVAL OR INSTALLATION OF LIGHTING, PLUMBING, MECHANICAL, ELECTRICAL SYSTEMS OR COMPONENTS WILL ADVERSELY AFFECT THE OPERATION OF EXISTING SITE ELECTRICAL OR MEP SYSTEMS OUTSIDE THE SCOPE OF WORK. 13. CONTRACTOR TO COORDINATE AND SUPPLY, LOCATION, & REMOVAL OF DUMPSTERS FOR DEMOLITION & CONSTRUCTION. 14. FINISHES, EQUIPMENT, HARDWARE, FURNISHINGS, APPLIANCES AND LIGHTING NOTSPECIFIEDARE TO BE APPROVED BY OWNER PRIOR TO PURCHASING MATERIALS. CONTRACTOR SHALL SUBMIT SAMPLES AND MANUFACTURER'S PRODUCT INFORMATION TO OWNER FOR APPROVAL. 15. ALL CONSTRUCTION, DEMOLITION AND RENOVATION SHALL COMPLY WITH REQUIREMENTS OF NFPA 241. STANDARDS FOR SAFEGUARDING CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS, 2013 EDITION. 16. TRASH AND CONSTRUCTION DEBRIS SHALL BE COLLECTED AND PLACED IN AN ON -SITE CONSTRUCTION DUMPSTER AT THE END OF EACH WORK DAY. PROJECT DATA SITE DATA PROJECT ADDRESS: SES / UNITED TELEPORTS 10161 Range Line Road Port St. Lucie, FL 34987 ZONING DESIGNATION: IH - INDUSTRIAL HEAVY FUTURE LAND USE. I ND MUNICIPALITY. SAINT LUCIE COUNTY PROPOSED CONSTRUCTION TYPE. TYPE II (UNPROTECTED) FULLY SPRINKLERED OCCUPANCY CLASSIFICATION. BUSINESS GROUP B PRIMARY USE. SATELLITE COMMUNICATIONS FACILITY BUILDING HEIGHT N/A DIVISION 1 -GENERAL REQUIREMENTS 1.01 ARCHITECT'S STATUS : THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR AND WILL NOT HAVE CONTROL OR CHARGE OF CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEEDURES' OR FOR THE SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK. THE CONTRACTOR IS SOLELY RESPONSIBLE TO CARRY OUT THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS, AND SHALL HAVE CONTROL OR CHARGE OVER THE ACTS OF THEIR SUBCONTRACTORS AND ANY OF THEIR AGENTS OR EMPLOYEES RELATED TO THE WORK. THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR PERFORMING ANY OF THE WORK. 1.02. CODES. A. ALL CODES HAVING JURISDICTION SHALL BE OBSERVED STRICTLY IN THE CONSTRUCTION OF THE PROJECT, INCLUDING ALL APPLICABLE STATE, CITY AND COUNTY BUILDING, ZONING, ELECTRICAL, MECHANICAL, PLUMBING, LIFE SAFETY & FIRE CODES. CONTRACTORSHALL VERIFY ALL CODE REQUIREMENTS IN THE COSTRUCTION DOCUMENTS TO THE ATTENTION OF THE ARCHITECT. B. CONSTRUCTION DOCUMENTS SHALL COMPLY WITH. • LAND DEVELOPMENT CODE SAINT LUCIE COUNTY, FLORIDA • FLORIDA BUILDING CODE, 2017 • FLORIDA FIRE PREVENTION CODE, 2017 • NFPA 101 2017 1.03 PERMITS: THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL REQUIRED BUILDING AND TRADE PERMITS AND THEIR RESPECTIVE COSTS. 1.04. JOB CONDITIONS. A. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRI OR TO SUBMITTAL OF BID AND/OR CONTRACT NEGOTIATIONS AND SHALL VERIFY EXISTING CONDITIONS WITH THE CONSTRUCTION DOCUMENTS, DISCREPANCIES BETWEEN CONSTRUCTION DOCUMENTS (AND THEIR INTENT) SHALL BE BROUGHTTO THE ARCHITECT'S ATTENTION FOR CLARIFICATION IN WRITING. BIDS SHALL NOT BE NOT BE SUBMITTED OR CONSTRUCTION CONTRACTS NEGOTIATED BY THE CONTRACTOR PRIORTO THE CLARIFICATION OF THE INTENT OF THE CONSTRUCTION DOCUMENTS WHERE SUCH INTENT IS IN DOUBT. B. DIMENSIONS AND NOTES SHALL TAKE PRECEDENCE OVER SCALE AND GRAPHICS. 1.05 WORK NECESSARY TO COMPLETE CONSTRUCTION IT IS THE PURPOSE OF THESE PLANS AND SPECIFICATIONS TO DESCRIBE A COMPLETE AND FINISHED PROJECT OTHER THAN ITEMS MARKED "N.1.C." (NOT IN CONTRACT. 1.06 CLEAN UP/ REPAIR A. THE CONTRACTOR SHALL MAINTAIN THE PREMISED CLEAD AND FREE OF ALL TRASH, DEBRIS AND SHALL PROTECT ALL ADJACENT WORK FROM DAMAGE, SOILING, PAINT 0VEIRS PRAY, ETC. ALL FIXTURES, EQUIPEMENT, GLAZING FLOOR, ETC. SHALL BE LEFT CLEAN AND READY FOR OCCUPANCY UPON COMPLETION OF THE PROJECT. B. THE CONTRACTOR SHALL REPAIR AND/OR REPLACE ALL EXISTING ITEMS DAMAGED BY THE PROCESS OF NEW CONSTRUCTION AND SHALL FINISH ALL PATCHWORK AND REPAIRS TO MATCH EXISTING ADJACENT AREAS AND SURFACES, 1.07 SHOP DRAWINGS: THE CONTRACTOR SHALL SUBMIT ELECTRONIC SETS OF SHOP DRAWINGS OF ALL FABRICATED ITEMS AND EQUIPMENT FOR OWNER'S / ARCHITECT'S REVIEW PRIOR TO FABRICATION AND COMMENCEMENT WITH THE WORK, 1.08 ALLOWANCES. FIXTURES, EQUIPMENT, HARDWARE AND FINISHES NOT SPECIFIED SHALL BE PROVIDED FOR IN THE CONTRACTOR'S BID AS LINE ITEM ALLOWANCES ON A SCHEDULE OF VALUES. 1.09 SCHEDULE. THE CONTRACTOR SHALL DELIVER TO THE OWNER, AS PART OF THE BID DOCUMENTS, THEIR PROPOSED SCHEDULE FOR CONSTRUCTION, INCLUDING COMMENCEMENTOF WORK THROUGH CERTIFICATE OF OCCUPANCY AND SHALL INCLUDE PRODUCT AM WORKMANSHIP WARRANTY PERIODS. BUILDING CODE SUMMARY SCOPE OF WORK. • ALTERATION -LEVEL 2: INTERIOR IMPROVEMENTS TO EXISTING COMMNUNICATIONS ROOM - ADDITION OF OFFICE SPACE AND STORAGE PLATFORM INSIDE OF EXISTING SINGLE STORY SATELLITE COMMUNICATIONS FACILITY DESIGN CRITERIA: FLORIDA BUILDING CODE 2017 - EXISTING BUILDING FLORIDA BUILDING CODE 2017 - BUILDING FLORIDA BUILDING CODE 2017 - ENERGY CONSERVATION LAND DEVELOPMENT CODE - SAINT LUCIE COUNTY, FLORIDA FLORIDA FIRE PREVENTION CODE 2017 LIFE SAFETY CODE, NFPA 101 - 2012 PROJECT CONSULTANTS: SURVEYOR CIVIL ENGINEER LAND PLANNER GEOTECHNICAL ENGINEER STRUCTURAL ENGINEER ARCHITECT MECHANICAL / ELECTRICAL / WATSON KILLANE MICHAEL B SCHORAH MANAGED LAND ENTITLEMENTS ANDERSEN ANDRE CONSULTING WIEDER ENGINEERING, INC. BRENT A. WOOD PLUMBING ENGINEER SURVEYING & MAPPING & ASSOCITATES, INC, 3710 BUCKEYE ST, ENGINEERS, INC. 11718 SE FEDERAL HWY#373 ARCHITECTURE, LLC, FORT PIERCE ENGINEERING, INC. 2240 NE DIXIE HWY, 1850 FOREST HILL BLD. SUITE 100 834 SW SWAN AVENUE HOBE SOUND, FL 33455 20 SE OCEAN BLVD. 315 SOUTH 7th STREET JENSEN BEACH, FL 34957 WPB, FL 33406 PBG, FL. 33410 PORT ST. LUCIE, FL 34983 STUART, FL. 34996 FT. PIERCE, FL. 34950 T 772-334-0868 T 561-968-0080 T 561-568-8045 T 772-807-9191 T 772-546-5823 T 772-220-1217 T 772-672-4636 SES'' beyond frontiers � U n ited Teen. ["'r,rt CROSSTOWN PARKWAY O Z TRADITION : •„ GATLIN BLVD. w PROJECT LOCATION a' r LOCATION PLAN NORTH DRAWING INDEX SHEET# SHE ET TITLE FIRST ISSUED REVISION NUMBER LATEST REVISION ARCHITECTURAL CV-1 COVERSHEET, DRAWING INDEX, ABBREVIATIONS, GENERAL NOTES, BUILDING CODE ANAL ISYS & PROJECT LOCATION MAP 07-15-2020 1 09-14-2020 STRUCTURAL S-1.01 FOUNDATION & MEZZANINE FRAMING PLANS 07-15-2020 S-2 01 STRUCTURAL NOTES & DETAILS 07-15-2020 ARCHITECTURAL EX-1.11 EXISTING BUILDING FLOOR PLAN 07-15-2020 EX-1.12 ENLARGED EXISTING RF-1 FLOOR PLAN 07-15-2020 EX-1.13 EXISTING REFLECTED CEILING PLAN @ RF-1 07-15-2020 D-1.11 DEMOLITION FLOOR PLAN & NOTES koo 07-15-2020 LS-1.11 LIFE SAFETY PLAN & NOTES 09-14-2020 1 09-14-2020 A-1.11 OVERALL BUILDING FLOOR PLAN 07-15-2020 - - A-1.12 ENLARGED RF-1 FLOOR PLAN & MEZZANINE PLAN 07-15-2020 A-1.13 ENLARGED RF-1 FINISH FLOOR PLAN & MEZZANINE FINISH PLAN 07-15-2020 A-1.14 ENLARGED RF-1 REFLECTED CEILING PLAN & MEZZANINE REFLECTED CEILING PLAN 07-15-2020 A-3.01 MEZZANINE SECTIONS & DETAILS 07-15-2020 A-3.02 MEZZANINE SECTIONS & DETAILS 07-15-2020 A-3 03 STAIR SECTIONS & DETAILS 07-15-2020 A-6 01 DOOR SCHEDULE, HARDWARE SCHEDULE, NOTES &DOOR TYPES 07-15-2020 ELECTRICAL E-1,0 ELECTRICAL SYMBOL LEGEND, SPECIFICATIONS & ABBREVIATIONS 07-15-2020 E-2.1 EXISTING ELECTRICAL POWER SYSTEMS FLOOR PLAN 07-15-2020 E-2.2 ENLARGED EXISTING POWER & LIGHTING PLANS 07-15-2020 E-2.3 ELECTRICAL NEW WORK POWER SYSTEMS PLANS 07-15-2020 E-3,1 LIGHTING SYSTEMS NEW WORK PLANS 07-15-2020 E-4,0 ELECTRICAL DETAILS, RISERS & SCHEDULES 07-15-2020 E-5,0 ELECTRICAL PANEL SCHEDULES 07-15-2020 MECHANICAL M-1.0 HVAC GENERAL NOTES, SYMBOLS & SCHEDULES 07-15-2020 M-2.1 HVAC EXISTING PLAN 07-15-2020 M-2.2 HVAC NEW FLOOR PLAN 07-15-2020 M-2.3 HVAC EXISTING & NEW ENLARGED FLOOR PLANS 07-15-2020 M-3.1 MECHANICAL DETAILS 07-15-2020 CHAPTER 8 803.1 GENERAL. INTERIOR WALL AND CEILING FINISH MATERIALS SHALL BE CLASSIFIED FOR FIRE PERFORMANCE AND SMOKE DEVELOPMENT IN ACCORDANCE WITH SECTION 803,1,1 OR 803,1.2, EXCEPTAS SHOWN IN SECTIONS 803.2 THROUGH 803.1.3. MATERIALS TESTE4D IN ACCORDANCE WITH SECTION 803.1.2 SHALL NOT BE REQUIRED TO BE TESTED IN ACCORDANCE WITH SECTION 803.1.1 803.1.1 INTERIOR WALL AND CEILING FINISH MATERIALS. INTERIOR WALL CAN CEILING FINISH MATERIALS SHALL BE CLASSIFIED IN ACCORDANCE WITH ASTM E 84 OR UL 723. SUCH INTERIOR FINISH MATERIALS SHALL BE GROUPED IN THE FOLLOWING CLASSES IN ACCORDANCE WITH THEIR FLAME SPREAD AND SMOKE -DEVELOPED INDEXES. CLASS A. = FLAME SPREAD INDEX 0-25, SMOKE DEVELOPED INDEX 0-450 CLASS B. = FLAME SPREAD INDEX 26-75, SMOKE DEVELOPED INDEX 0-450 CLASS C. = FLAME SPREAD INDEX 76-200, SMOKE DEVELOPED INDEX 0-450 EXCEPTION: MATERIALS TESTED IN ACCORDANCE WITH SECTION 8031.2 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY k GROUP SPRINKLERED INTERIOR EXIT CORRIDORS AND STAIRWAYS, ENCLOSURE FOR ROOMS AND INTERIOR EXIT EXIT ACCESS ENCLOSED RAMPS AND EXIT STAIRWAYS AND SPACES C PASSAGEWAYS a'b EXIT ACCESS RAMPS B B C C FOR SI. 1 INCH = 25.4 MM, 1 SQUARE FOOT = 0,0929M2, a) CLASS C INTERIOR FINISH MATERIALS SHALL BE PERMITTED FOR WAINSCOTTING OR PANELING OF NOT MORE THAN 1,000 SQUARE FEET OF APPLIED SURFACE AREA IN THE GRADE LOBBY WHERE APPLIED DIRECTLY TO A NONCOMBUSTIBLE BASE OR OVER FURRING STRIPS APPLIED TO A NONCOMBUSTIBLE BASE AND FIREBLOCKED AS REQUIRED BY SECTION 803.13.1. b) IN OTHER THAN GROUP 1-3 OCCUPANCIES IN BUILDINGS LESS THAN THREE STORIES ABOVE GRADE PLANE, CLASS B INTERIOR FINISH FOR NONSPRINKLERED BUILDINGS AND CLASS C INTERIOR FINISH FOR SPRINKLERED BUILDINGS SHALL BE PERMITTED IN INTERIOR EXIT STAIRWAYS AND RAMPS, c) REQUIREMENTS FOR ROOMS AND ENCLOSED SPACES SHALL BE BASED UPON SPACES ENCLOSED BY PARTITIONS, WHERE A FIRE -RESISTANCE RATING IS REQUIRED FOR STRUCTURAL ELEMENTS, THE ENCLOSING PARTITIONS SHALL EXTEND FROM THE FLOOR TO THE CEILING, PARTITIONS THAT DO NOT COMPLY WITH THIS SHALL BE CONSIDERED ENCLOSING SPACES AND THE ROOMS OR SPACES ON BOTH SIDES SHALL BE CONSIDERED ONE. IN DETERMINING THE APPLICABLE REQUIREMENTS FOR ROOMS AND ENCLOSED SPACES, THE SPECIFIC OCCUPANCY THEREOF SHALL BE THE GOVERNING FACTOR REGARDLESS OF THE GROUP CLASSIFICATION OF THE BUILDING OR STRUCTURE. k) FINISH MATERIALS AS PROVIDED FOR IN OTHER SECTIONS OF THIS CODE. Y�� � �l �IO C4 d 0 N O N 67 Q Y C� L U Y C U CL Q) U V � J Digitally signed by Brent Brent A. Wood DN: cn=Brent A. Wood, o=Brent A. Wood A. Architecture, LLC., ou=Architecture, email=erick@bawoodar c=US Wood Date: 2, Date: 2020.09.14 12:52:10-04'00' o � 5� J u_ z �LL [� a > ti O m N O c �U Q m a/ �-1 0 CV z w� MM w u� m CA F_ U) m Y -0 =w Z �w w z 0 Q 0 z w W z LLl 0:E a-w LU w ° LU 45 E z ILLE z t v 'o d a LLI {n Q 0 W ZJ -Q � Z J Q Z LU 00 a° Z Z Op U� O06 H W LIJ Z LLJ O = I- o w J Z W 0 U § OQ a UU Co rn w z J J w u_ (D aS Z Q J 65 L 0 N d 0 o N N j N � c7)Q E > z a� C CD es aid p O N Cl) d d