HomeMy WebLinkAboutsoil testArdaman in -Place Density Report Client: & Associates, Inc. Permit # 2006-0514 Report Date: 8/3/2020 Port St. Lucie Branch Test Method: ASTM D 6938 Florida CA No. 5950 460 NW Concourse Place, Unit 1 Port St. Lucie, FL 34986 Phone:772-878-0072 Renar Development Corp. 3725 S. East Ocean Boulevard, Suite 101 Stuart, FL 34996 Project: 113-15-66-5434B Morningside Residential Lots Fort Pierce Fort Pierce, FL 051 Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture N Maximum Dry Density (pcf) In Place Moisture N In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min Comp. N Remark 320 7/31/20 20-207 (Modified) A - 11.5 115.0 9.8 108.9 12 95 95 Pass .321 7/31/20 20-207 (Modified) A - 11.5 115.0 8.7 109.4 12 95 95 Pass 322 7/31/20 20-207 (Modified) A - 11.5 115.0 9.3 109.7 12 95 95 Pass 323 7/31/20 20-207 (Modified) A - 11.5 115.0 9.0 111.0 12 97 95 Pass 324 7/31/20 20-207 (Modified) A 11.5 115.0 11.7 109.6 12 95 95 Pass 325 7/31/20 20-207 (Modified) A 11.5 115.0 12.4 110.6 12 96 95 Pass 326 7/31/20 20-207 (Modified) A -- 11.5 115.0 10.9 111.4 12 97 95 Pass 327 7/31/20 20-207 (Modified) A -- 11.5 1 115.0 1 13.2 1 110.2 12 96 95 Pass Test Information Test # Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 320 Foundation: Housepad Lot 110. 340 Palm Breezes Dr. SW Corner -1.0 Top of Pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie 321 Foundation: Housepad Lot 110. 340 Palm Breezes Dr. NW Corner -1.0 Top of Pad Troxler / T-3430 121330 / Tech, Port St. Lucie 322 Foundation: Housepad Lot 110. 340 Palm Breezes Dr. NE Corner -1.0 Top of Pad Troxler / T-3430 121330 / Tech, Port St. Lucie 323 Foundation: Housepad Lot 110. 340 Palm Breezes Dr. SE Corner -1.0 Top of Pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie 324 Footings: Housepad Lot 110. 340 Palm Breezes Dr. SE Corner -2.0 Top of Pad Troxler / T-3430 121330 / Tech, Port St. Lucie 325 Footings: Housepad Lot 110. 340 Palm Breezes Dr. SW Corner -2.0 Top of Pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie 326 Footings: Housepad Lot 110. 340 Palm Breezes Dr. NW Corner -2.0 Top of Pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie 327 Footings: Housepad Lot 110. 340 Palm Breezes Dr. NE Corner -2.0 Top of Pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie Remarks Comments Pass: Density Pass Tests are "Direct Transmission" (Method A) unless probe depth is noted as 1"Backscatter". Gauge calibration data on file with the testing agency. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 2 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL. Ardaman In -Place Density Report Client: Project: & Associates, Inc. Permit # 2006-0514 Renar Development Corp. 113-15-66-5434B Report Date: 8/3/2020 3725 S. East Ocean Boulevard, Suite 101 Morningside Residential Lots Port St. Lucie Branch Test Method: ASTM D 6938 Stuart, FL 34996 Fort Pierce Florida CA No. 5950 Fort Pierce, FL 460 NW Concourse Place, Unit 1 Port St. Lucie, FL 34986 Phone: 772-878-0072 fe/4 -71 c:�, ~�r'��'ic'r`�, 'j'��O ' No.63911 � OF R This item has been digitally signed and sealed by Branch Manager Dan J. Zrallack, P.E. on Aug 03, 2020 using a Digital Signature. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any electronic copies. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND -OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.