HomeMy WebLinkAboutsoil testArdaman in -Place
Density Report Client:
& Associates, Inc. Permit # 2006-0514
Report Date: 8/3/2020
Port St. Lucie Branch Test Method: ASTM D 6938
Florida CA No. 5950
460 NW Concourse Place, Unit 1
Port St. Lucie, FL 34986
Phone:772-878-0072
Renar Development Corp.
3725 S. East Ocean Boulevard, Suite 101
Stuart, FL 34996
Project:
113-15-66-5434B
Morningside Residential Lots
Fort Pierce
Fort Pierce, FL
051
Test Results
Test #
Retest
Of
Test
Date
Proctor ID
Method
Soil
Classification
Optimum
Moisture
N
Maximum
Dry Density
(pcf)
In Place
Moisture
N
In Place
Dry Density
(pcf)
Probe
Depth
(in)
Percent
Compaction
Min Comp.
N
Remark
320
7/31/20
20-207
(Modified)
A
-
11.5
115.0
9.8
108.9
12
95
95
Pass
.321
7/31/20
20-207
(Modified)
A
-
11.5
115.0
8.7
109.4
12
95
95
Pass
322
7/31/20
20-207
(Modified)
A
-
11.5
115.0
9.3
109.7
12
95
95
Pass
323
7/31/20
20-207
(Modified)
A
-
11.5
115.0
9.0
111.0
12
97
95
Pass
324
7/31/20
20-207
(Modified)
A
11.5
115.0
11.7
109.6
12
95
95
Pass
325
7/31/20
20-207
(Modified)
A
11.5
115.0
12.4
110.6
12
96
95
Pass
326
7/31/20
20-207
(Modified)
A
--
11.5
115.0
10.9
111.4
12
97
95
Pass
327
7/31/20
20-207
(Modified)
A
--
11.5
1 115.0
1 13.2
1 110.2
12
96
95
Pass
Test
Information
Test #
Test Location
Elevation
Reference
Gauge
Make / Model / SN / Calibrated
Field Technician
320
Foundation: Housepad Lot 110. 340 Palm Breezes Dr. SW Corner
-1.0
Top of Pad
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
321
Foundation: Housepad Lot 110. 340 Palm Breezes Dr. NW Corner
-1.0
Top of Pad
Troxler / T-3430 121330 /
Tech, Port St. Lucie
322
Foundation: Housepad Lot 110. 340 Palm Breezes Dr. NE Corner
-1.0
Top of Pad
Troxler / T-3430 121330 /
Tech, Port St. Lucie
323
Foundation: Housepad Lot 110. 340 Palm Breezes Dr. SE Corner
-1.0
Top of Pad
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
324
Footings: Housepad Lot 110. 340 Palm Breezes Dr. SE Corner
-2.0
Top of Pad
Troxler / T-3430 121330 /
Tech, Port St. Lucie
325
Footings: Housepad Lot 110. 340 Palm Breezes Dr. SW Corner
-2.0
Top of Pad
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
326
Footings: Housepad Lot 110. 340 Palm Breezes Dr. NW Corner
-2.0
Top of Pad
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
327
Footings: Housepad Lot 110. 340 Palm Breezes Dr. NE Corner
-2.0
Top of Pad
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
Remarks
Comments
Pass: Density Pass
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
1"Backscatter". Gauge calibration data on file with the testing agency.
AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 2
THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED
PENDING OUR WRITTEN APPROVAL.
Ardaman In -Place Density Report Client: Project:
& Associates, Inc. Permit # 2006-0514 Renar Development Corp. 113-15-66-5434B
Report Date: 8/3/2020 3725 S. East Ocean Boulevard, Suite 101 Morningside Residential Lots
Port St. Lucie Branch Test Method: ASTM D 6938 Stuart, FL 34996 Fort Pierce
Florida CA No. 5950 Fort Pierce, FL
460 NW Concourse Place, Unit 1
Port St. Lucie, FL 34986
Phone: 772-878-0072
fe/4 -71 c:�,
~�r'��'ic'r`�, 'j'��O
' No.63911 �
OF
R
This item has been digitally signed and sealed by Branch
Manager Dan J. Zrallack, P.E. on Aug 03, 2020 using a
Digital Signature.
Printed copies of this document are not considered signed
and sealed and the SHA authentication code must be
verified on any electronic copies.
AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND -OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2
THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED
PENDING OUR WRITTEN APPROVAL.