HomeMy WebLinkAboutExtreme Metal Fab Steel Roof Prod Approval2160 SW Poma Drive
Palm City, FL 34990
Compliant with Florida Building Code 2017 (6" ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Product: 1" Nailstrip 26GA Steel Roof Panel FBC Sec. 1507.4.2
Yield strength: 50 ksi min.; Attached to min.15/32" plywood or
Wood Deck w/ 0.42 specific gravity with 16" Coverage (Max.)
Rib Height V
Corrosion Resistant Compliant: FBC Sec.1507.4.3
Fastener 1: #10 x 1" (min.) Pancake Head Wood Screw to penetrate 3/16" (min.) thru
bottom of support.
Adhesive/Sealant : Bostik 915" Chem -Chalk one component, polyurethane adhesive with
3/16" continuous bead application along base of male rib vertical flange at each panel
seam.
Underlayment: To be compliant with FBC Sec 1507.1.1
Slope: Shall be in compliance with FBC Sec.1507.
install Details: Table A
DESIGN PRESSURE*
FASTENER SPACING
SEAM ADHESIVE
Allowable Loads
METHOD 1
.86 PSF Main field
6" O.C.
Not required
METHOD 2
-97.25 PSF Perimeter
6" O.C.
3/16" continuous bead
(see details) _
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527
UL 580-06 & UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen #1 & #2
EQUIVALENCY. UL1897-04 is equivalent to Test Standard UL1897--12.
Pressure margin of safety 2:1
Certificate of Independence:
Locke Bowden, P.E. does not have, not will acquire a financial "Stirr agyycompany manufacturing or distributing products
under this evaluation. �,�°�[_ 'B0�V
Locke Bowden, A.E. is not owned, operated, or controll y rr�p�� cturer, or distributing products under this
report. ! � • .
• -
1 7
sea!
STATE OF +4 4,
4.
•1.....i110
Limitations:
1. Underlaymentto be compliance with current Florida Building Code (FBC)2017 6t' ed..
2. Minimum slope to be compliant with Florida Building Code 2017 6t' ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method. 1-B
4. Engineering analysis for "project specific approval by local authorities wljurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 61 ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural
Loading.
7. This report does not imply warranty, Installation, recommended product use outside of this report.
FL 17022.5 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details
1611
Panel Profile
16" o.c.
314"
i
Deck:
-15132" or greater Plywood, or
- Wood plank
Integral Snap Lock
For METHOD 2:
Apply 311V Bead Bostik 915T"' Sealant
Continuous Along Male Rib Vertical Flange
Fastener
#10 x 1" Min. per Table "A"
Pancake Head Wood Screw
(Typical Fastening Pattern Across Width)
FL 17022.5 1.0 Nail Strip (26GA Steel), 1 B" Wide Roof Panel - Details
Fastener
#1 D x 1" Min. per Table "A"
Pancake Head Wood Screw
1" Dail Strip Roof Panel
Deck:
-15132" or greater Plywood, or
- Wood plank
Isometric View
Seam Adhesive Application:
For Method 2
Apply W16" Bead Bostik 915TM Sealant
ContinuousAlong Male Rib Vertical Flange
(Refer to Table'W)