Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Fl-orida Department of Business and Professional Regulation - Residential Performance Method Project Name: FYC-PSL-Wardwell Builder Name: Synery Homes, LLC' Street: 6104 Yucca Drive Permit Office: City, State, Zip: Fort Pierce, FL, 34982 Permit Number: Owner: Synergy Homes, LLC Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1301.4 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=6.5 1136.00 ft2 b. Frame - Wood, Adjacent R=13.0 165.36 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (1450.0 sgft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 1450.00 ft2 6. Conditioned floor area above grade (ft2) 1450.12902832 b. N/A R= ft2 c. N/A R= ft2 Conditioned floor area below grade (ft2) 0 11. Ducts R ft2 7. Windows(118.0 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 290.02 a. U-Factor: Dhl, U=0.32 118.02 ft2 SHGC: SHGC=0.19 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 24.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 16.0 COPA.00 SHGC: Area Weighted Average Overhang Depth: 2.526 ft. Area Weighted Average SHGC: 0.190 14. Hot water systems a. Electric Cap: 50 gallons 6. Floor T Types 1450.0 s ft.) Insulation Area yp ( fl EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1450.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.081 Total Proposed Modified Loads: 48.39 PASS , Total Baseline Loads: 48.45 F1.7.7 1 hereby certify that the plans and specifications covered by Review of the plans and OF SHE STq�F this calculation are in compliance with the Florida Energy specifications covered by this y „ _ - r O� Code. calculation indicates compliance u� ri., with the Florida Energy Code. > PREPARED BY: Xis Before construction is completed aUrp ry O DATE: a 1/12/2019 this building will be inspected for compliance with Section 553.908 �� wO A I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. COD WEJ OWNER/AGEMT:-� BUILDING OFFICIAL: DATE: q 1 q' ( 0! DATE: _I - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed In accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACISVCC§JQW&D FOR CODE COMPLIANCE E ST, LUCIE COUNTY BOCC 11/12/2019 12:54 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - F aRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: ' Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: FYC-PSL-Wardwell User Synergy Homes, LLC 1 Synery Homes, LLC Single-family New (From Plans) Kingston Model Bedrooms: 3 Conditioned Area: 1450 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: Whole House Fan: Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 6104 Yucca Drive County: St. Lucie City, State, Zip: Fort Pierce , FL, 34982 CLIMATE Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 1450.129 11601 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Whole House 1450.129 11601 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Whole House 165 ft 0 1450 ft2 ---- 0.85 0 0.15 ROOF V # Roof Gable Roof Type Materials Area Area Color Red Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1571 ft2 0 ft2 Medium N 0.75 No 0.9 No 20 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1450 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) Whole House 0 Blown 1450 ft2 0.11 Wood 1111212019 12:54 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant. Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS ' Adjacent Cavity Width Height Sheathing Framing Solar Below n"I Space 1 E Exterior Concrete Block - Int InsUYhole House 6.5 13.67 0 8 0 109.4 ft2 0 0 0.8 0 2 _ S Exterior Concrete Block - Int InsUVhole House 6.5 16 0 8 0 128.0 ft2 0 0 0.8 0 _ _ 3 S Exterior Concrete Block - Int InstHhole House 6.5 10 0 8 0 80.0 ft2 0 0 0.8 0 -4 W Garage Frame - Wood Whole House 13 6.67 0 8 0 53.4 ft2 0 0.23 0.8 0 -5 W Garage Frame - Wood Whole House 13 6 0 8 0 48.0 ft2 0 0.23 0.8 0 _ 6 S Garage Frame - Wood Whole House 13 2 0 8 0 16.0 ft2 0 0.23 0.8 0 _ 7 W Garage Frame - Wood Whole House 13 6 0 - 8 0 48.0 ft' 0 0.23 0.8 0 _ 8 W Exterior Concrete Block - Int InsUVhole House 6.5 16.5 0 8 0 132.0 ft' 0 0 0.8 0 _ 9 E Exterior Concrete Block - Int InsWhole House 6.5 11.5 0 8 0 92.0 ft2 0 0 0.8 0 _ 10 E Exterior Concrete Block - Int InsUVhole House 6.5 11.67 0 8 0 93.4 ft2 0 0 0.8 0 11 E Exterior Concrete Block - Int InsWhole House 6.5 14 0 8 0 112.0 ft' 0 0 0.8 0 _ 12 N Exterior Concrete Block - Int InsUVhole House 6.5 14 0 8 0 112.0 ft' 0 0 0.8 0 _ 13 N Exterior Concrete Block - Int InsUVhole House 6.5 5 0 8 0 40.0 ft' 0 0 0.8 0 _ 14 W Exterior Concrete Block - Int InslWhole House 6.5 13.33 0 8 0 106.6 ft' 0 0 0.8 0 _ 15 N Exterior Concrete Block - Int InsUVhole House 6.5 13.33 0 8 0 106.6 ft2 0 0 0.8 0 16 S Exterior Concrete Block - Int InsUVhole House 6.5 3 0 8 0 24.0 ft' 0 0 0.8 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated Whole House None .29 2.7 6.7 17.8 ft2 2 W Insulated Whole House None .29 3 8 24 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 1 Vinyl Low-E Double Yes 0.32 0.19 N 15.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 2 S 3 Vinyl Low-E Double Yes 0.32 0.19 N 4.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 3 W 8 Vinyl Low-E Double Yes 0.32 0.19 N 20.0 ft2 4 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 4 E 9 Vinyl Low-E Double Yes 0.32 0.19 N 40.0 ft2 4 ft 0 in 1 ft 0 in Drapes/blinds None 5 E 10 Vinyl Low-E Double Yes 0.32 0.19 N 9.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 6 E 11 Vinyl Low-E Double Yes 0.32 0.19 N 15.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 7 W 14 Vinyl Low-E Double Yes 0.32 0.19 N 15.0 ftz 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation ' 1 400 ft2 400 ft2 60 ft 8 ft 0 11/12/2019 12:54 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 r=nann Pena-0n17 IPIPI IT SI IMMARY CHECKLIST REPORT INFILTRATION # Scapa Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 966.8 53.07 99.81 .0881 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Black Ducts 1 Electric Strip Heat/ None COPA 16 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ None SEER: 16 24 kBtu/hr 720 cfm 0.77 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft' DUCTS / --- Supply---- V # Location R-Value Area ---- Return --- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC # Heat Cool 1 Attic 6 290.02 Attic 72.506 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Y r Programabl[e an Heat ng (XI Jan [� Feb [ Mar Venting [[ ]) Jan l 111 Feb [[[���111 Mar Crfeiling Fans:Coollf ]] f[` ]J fl]j [� ]]]8ctfr N Apr (I May Jay un lxl Jul lxl Aug lXl Sep 1xl Oct [ Nov Jun (((( 1111 Jul [[[[ 1111 Aug 1111 Sep lxl Dec Dec 11/12/2019 12:54 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 ,Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 76 78 78 78 78 78 78 78 78 _ PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD)- AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 65 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System Runtime Vent 50 0 0 0 1 - Electric Strip Heat % 1 -Central Unit MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft' 0 ft 0.3 Whole House 11 /12/2019 12:54 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* =100 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 2-4 0 a) Split system SEER 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1450 d) Room unit/PTAC EER e) Other 16.0 7. Windows, type and area a) U4actor:(weighted average) 7a. 0,320 b) Solar Heat Gain Coefficient (SHGC) 7b. 0,190 14. Heating system: Capacity-1 60 c) Area 7c. 118.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 6.5 f) Heat recovery unit HeatReC% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 13.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 0.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No ,c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: �� _ Date: Address of New Home: 6104 Yucca Drive City/FL Zip: Fort Pierce, FL 34982 11/12/2019 12:55:07 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1