Loading...
HomeMy WebLinkAboutCertification for Design Load ComplianceR b a' Planning& Development Services Department Building & Code Regulations Division D 2300 Virginia Avenue, Fort Pierce, FL 34982— (772) 462-1553 ST. I_ucle County, Permitting Certification for Design Load Compliance Project Name: SCHNEIDER Project Address: 119 QUEEN ELIZABETH CT, FORT PIERCE, FL 34949 Permit#: Occupancy Type: Construction INSTRUCrIONS FOR USE: This certification must be completed, signed, and sealed by the design professional of record. o Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential, Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for Interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida BUILDING Code Sixth Edition with 2017 Supplements using ASCE 7-10 2. Structure Designed as (check one): _Enclosed _Partially Enclosed X Open 3. Risk Category:_I X II _III_IV Exposure Category:—B—C X D 4. Design Wind Velocity165 mphASD X LRFD End Zone Width: 1 ft S. Mean Roof Helght 5+/- DECK HEIGHT ft Roof Pitch: :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: Zone 2:—Zone 3:Zane 4:+60.6/-64.1 Zone 5:+70.1/-74.5 Garage: 7. Design Loads: Floor: PSF Roof/Dead—.PSF Roof/Live—.Balcony: PSF Dock: 40 PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF B. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X YesNot Applicable Explain Why Not: 10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the b knowledge and belief, the attached plans & specifications have been designed to comply with the � licab'tkntt© portions of the building codes currently adopted and enforced by St. Lucie County. I also that strut ments depicted on these plans provide adequate resistance to the design forces sp y VOI21OlH O0 DANIEL PAUL RETHERFORD 72451 =10 1,V1S int Name Cert # & Co. Cert Auth. p TSb2L ON 0 d 3'N1 ICopy 1 z Signature, yn seal n� ? 1402 HARTMAN ROAD, FORT PIERCE, FL 34947 Company Name &Address REVIEWED FOR Revised 12/07/2018 CODE COMPLIANCE ST. LUCIE COUNTY BOCC