- wrightsoft' Load Short Form Entire House Project Information For: MW-57 2630 KNOLLWOOD LN, FORT PIERCE, FL 34951 Job: Date: Nov 4, 2019 By: Design Information Htg Clg Infiltration Outside db (°F) 43 91 Method Simplified Inside db (°F) 70 72 Construction quality Semi -tight Design TD (°F) 27 19 Fireplaces 0 Daily range - L Inside humidity (%) 30 50 Moisture difference (gr/lb) 0 65 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Lennox Trade Trade 14ACX SERIES Model Cond 14ACX-047-230' AHRI ref Coil CBX27UH-048-230`++TDR AHRI ref 3869174 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 8.8 kW Sensible cooling 32550 Btuh Heating output 30073 Btuh Latent coaling 13950 Btuh Temperature rise 18 OF Total cooling 46500 Btuh Actual air flow 1550 cfm Actual air flow 1550 cfm Air flow factor 0.052 arm/Btuh Air flow factor 0.047 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.69 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (Cfm) Clg AVF (Cfm) MASTER SUITE 305 4704 3895 244 183 HIS WIC 40 666 350 34 16 MASTER BATH 166 1781 2088 92 98 HER WIC 74 62 267 3 13 DEN 201 4178 3202 216 151 FOYER 69 1465 1367 76 64 DINING 175 2506 2279 130 107 MECH 34 414 694 21 33 UTILITY 59 72 771 4 36 BATH 2 58 995 1132 52 53 BED 2 180 1716 2788 89 131 BED 3 178 1761 2804 91 132 BATH 3 58 1659 1348 86 63 NOOK 147 3479 2679 180 126 KITCHEN 222 185 1961 10 92 207 235 GREAT RM 445 3988 4990 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Nov-06 14:21:20 g wr19ht90ffr RightSulte® Universal 201212.1.05 RSU02818 Pagel )m C:1UsersVason\DocumentslWrightsaR HVAC\MW-57.rup Calo=MJ8 Front Door faces: S U IILIIY HALL 8b Jul JJL to -ib Entire House 2507 29931 32944 1550 1550 Other equip loads 0 0 Equip. @ 0.95 RSM 31462 Latent cooling 14837 T/ Al C 4LLrI 4LLn Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. � +C wrightSOW RightSeite® Universal 201212.1.05 RSU02818 /Ai{rl� C:\UsemWawn\Documents\Wrightsoft HVAC\MW-57.mp Caic=MJ8 Front Doorfaces: S 2019-Nov-08 14:21.20 Page 2 - wrightsoftProject Summary Entire House Project Information For: MW-57 2630 KNOLLWOOD LN, FORT PIERCE, FL 34951 Notes: Design Information Weather: Vero Beach Municipal AP, FL, US Job: Date: Nov 4, 2079 By: Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 91 OF Inside db 70 OF Inside db 72 OF Design TO 27 OF Design TO 19 OF Daily range L Relative humidity 50 % Moisture difference 65 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 25136 Btuh Structure 24591 Btuh Ducts 4795 Btuh Ducts 8353 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 29931 Btuh Use manufacturers data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 31462 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construcflon quality Semi -tight Fireplaces 0 Structure 12578 Btuh Ducts 2259 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft2) 2507 2507 Equipment latent load 14837 Btuh Volume (ft) 24389 24389 Air changes/hour 0.22 0.11 Equipment total load 46299 Btuh Equiv. AVF (cfm) 89 45 Req. total capacity at 0.70 SHR 3.7 ton Heating Equipment Summary Cooling Equipment Summary Make Make Lennox Trade Trade 14ACX SERIES Model Cond 14ACX-047-230* AHRI ref Coil CBX27UH-048-230*++TDR AHRI ref 3869174 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 8.8 kW Sensible cooling 32550 Btuh Heating output 30073 Btuh Latent cooling 13950 Btuh Temperature rise 18 OF Total cooling 46500 Btuh Actual air flow 1550 cfm Actual air flow 1550 cfm Air flow factor 0.052 cfm/Btuh Air flow factor 0.047 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.69 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. C Wrl t1t`SOfY 201&Nov-061421:21 g RightSuite® Universal 201212.1.05 RSU02818 Page C:\UsemJason\Downnents\Wrlghtsoft HVACWW-57.mp Cale =MIA Front Door faces: S Cl 4TON BEDROOM 3 1 lax Io.T BEDROOM 2 1Ox10xT 2 2 CAR GARAGE NOOK tOX1axT 125 CFM 1 COVERED LANAI Y MASTER SUITE L199 CFM xIJ ro W: HERS tBY1fi' axe I CHEAT ROW FLAG.OIT It CFM 6x FLEX BX5 I 2xxe 13C 10CFM KIT 9TCFM tY Y 9Y ti OFM TSTAT SHALL BE W IN 3 FEEf O. HORRONTALLY OF MAIN RETURN 8a8x6 TOCFM WASTER 21k RAG. eY BATH wo 5Y So W CFM r O EXHAUST UPL 10A fa xT taTCFM 2k12 e X6x5 _ BAB%B 6� 84 CFM �"G' F(EX 39 CFM rO DRYER EXHAUST ro FOYER toxtoxe 20Y DDING 151 CFM AHU-1 DEN LTON GENTRY 9 2CFM O ENTRY DO NOT 804.E PLANS L GHO HOMES MW-57 9630 KNOLLWOODLN FORT PIERCE, FL 34951