Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
FL NOA 18-0430.06
M IAM I•QADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy PGT Industries, Inc. 1070 Technology Drive North Venice, FL 34275 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami —Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. - DESCRIPTION: Series "SH7700A" Aluminum Single Hung Window — L.M.I. APPROVAL DOCUMENT: Drawing No. 7700NOA-1, titled "Aluminum Single Hung Install (LM)", sheets 1 through 11 of 11, dated 04/01/18, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E., bearing the Miami -Dade County Product Control Approval stamp with the Notice of Acceptance number and approval date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of this page 1 and evidence pages E-1 and E-2, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez, P.E. NOA No. 18-0430.06 Expiration Date: August 23, 2023 Approval Date: August 23, 2018 Page 1 PUT Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No. 7700NOA4, titled "Aluminum Single Hung Install (LM), sheets 1 through 11 of 11, dated 04/01/18, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411.3.2.1, and TAS 202-94 along with marked -up drawings and installation diagram of an aluminum single hung window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL48-7835.1, dated 04/03/18, signed and sealed by Idalmis Ortega, P.E. 2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411.3.2.1, and TAS 202-94 window, prepared by Fenestration Testing Laboratory, Inc., Test Reports No. FTL484835.2, dated 05/04/18, signed and sealed by Idalmis Ortega, P.E. C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 6tn Edition (2017), dated 04/23/18, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 2. Glazing complies with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER). Product Contral Exa finer NOA No. 0 30.06 Expiration Date: August 239 2023 Approval Date: August 23, 2018 E-1 PGT Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 17-1114.14 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 01/18/18, expiring on 07/08/19. 2. Notice of Acceptance No. 17-0808.02 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Glass Interlayers" dated 12/28/17, expiring on 07/04/230 F. STATEMENTS 1. Statement letter of conformance to FBC 6th Edition (2017), dated April 24, 2018, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 2. Statement letter of no financial interest, dated April 24, 2018, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 3. Proposal No. 1&0005R issued by the Product Control Section, dated 01/16/18, signed by Manuel Perez, RE G. OTHERS 1. None. E-2 ManuelPer .E. Product Control E a ner NOA No. 18-0 30.06 Expiration Date: August 23, 2023 Approval Date: August 23, 2018 SERIES SH7700A IMPACT RESISTANT SINGLE HUNG WINDOW 1) THIS PRODUCT HAS BEEN DESIGNED & TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ). 2) SHUTTERS ARE NOT REQUIRED WHEN USED IN WIND-BORNE DEBRIS REGIONS. FOR INSULATED GLASS INSTALLATIONS ABOVE 30' IN THE HVHZ, THE OUTBOARD LITE (CAP) MUST BE TEMPERED, USE ONLY GLASS TYPES 3, 7, 12, 13 OR 15. 3) FOR MASONRY APPLICATIONS IN MIAMI-DADE COUNTY, USE ONLY MIAMI-DADE COUNTY APPROVED MASONRY ANCHORS. MATERIALS USED FOR ANCHOR EVALUATIONS WERE SOUTHERN PINE, ASTM C90 CONCRETE MASONRY UNITS AND CONCRETE WITH MIN. KSI PER ANCHOR TYPE. 4) ALL WOOD BUCKS LESS THAN 1-1/2" THICK ARE TO BE CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2" THICK OR GREATER. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED AND SECURED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. WOOD BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER, (EOR) OR ARCHITECT OF RECORD, (AOR). 5) ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. USE ANCHORS OF SUFFICIENT LENGTH TO ACHIEVE REQUIRED MIN, EMBEDMENT. INSTALLATION ANCHORS SHOULD BE SEALED. OVERALL SEALING & FLASHING STRATEGY FOR WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS AND IS BEYOND THE SCOPE OF THESE INSTRUCTIONS. 6) 1/4" MAX. SHIMS ARE REQUIRED AT EACH ANCHOR LOCATION WHERE THE PRODUCT IS NOT FLUSH TO THE SUBSTRATE. USE SHIMS CAPABLE OF TRANSFERRING APPLIED LOADS. 7) DESIGN PRESSURES: A. NEGATIVE DESIGN LOADS BASED ON STRUCTURAL &CYCLE TESTING AND GLASS PER ASTM E1300. B. POSITIVE DESIGN LOADS BASED ON WATER TEST PRESSURE, STRUCTURAL & CYCLE TESTING AND GLASS PER ASTM E1300, C. DESIGN LOADS ARE BASED ON ALLOWABLE STRESS DESIGN, ASD, 8) THE ANCHORAGE METHODS SHOWN HAVE BEEN DESIGNED TO RESIST THE WINDLOADS CORRESPONDING TO THE REQUIRED DESIGN PRESSURE. THE 33-1/3%STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT, THE 1.6 LOAD DURATION FACTOR WAS USED FOR THE EVALUATION OF ANCHORS INTO WOOD. ANCHORS THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE FLORIDA BUILDING CODE FOR CORROSION RESISTANCE, 9) METAL SUBSTRATE TO MEET MIN. STRENGTH AND THICKNESS REQUIREMENTS PER CURRENT FLORIDA BUILDING CODE AND TO BE REVIEWED BY THE AUTHORITY HAVING JURISDICTION, 10) REFERENCES: TEST REPORTS FTL 18-7835.1 & 18-7835.2; ELCO ULTRACON NOA; ELCO CRETEFLEX NOA; NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION, ANSI/AF&PA NDS & ALUMINUM DESIGN MANUAL 11) APPLICABLE EGRESS REQUIREMENTS TO BE REVIEWED BY BUILDING OFFICIAL. FIGURE A: ALLOWABLE SASH CONFIGURATIONS AND SHAPES C7 0 / w w w w _ W / RECTANGULAR RADIUS -TOP RECTANGULAR WITH EQUAL WITH PROVIEW WITH CUSTOM LITE SASH SASH SASH ALL SHAPES WITH ALL SASH CONFIGURATIONS ARE APPROVED, SHAPES MAY BE USED BY INSCRIBING THE SHAPE IN A BLOCK AND OBTAINING DESIGN PRESSURES AND ANCHORAGE FOR THAT BLOCK SIZE FROM THE TABLES ON THE FOLLOWING SHEETS. 17-3/4" MAX. (17-1/4" BUCK) B, SEE SHEETS 8 & 9 f A, SEE SHEETS 8 & 9 r EQUALLY SPACED ANCHORS PER TABLES 6 & 7 EQUALLY SPACED ANCHORS PER TABLES 6 & 7 9-1/2 " MAX. (9" MAX. BUCK) 17-13/16" MAX. O.0 18-3/8" MAX. 17-3l4" MAX. 9-1/2" MAX. O.C. (9 11 MAX. BUCK) 53-1/8" MAX. TIP TO TIP WIDTH _ T 17-3/16" MAX. C i 12-1/16" MAX. C 13 5/16jl" MAX _ 1 _i 84" MAX. TIP TO TIP HEIGHT 1" WEEP NOTCH AT EACH END ELEVATION FOR TYP. FLANGE FRAME SHOWN WITH EQUAL-LITE CONFIGURATION TART F 1 • AI I nWABLE GLASS TYPES Tia� Yp Description (Listed from Exterior to Interior) Tab e # 1 1/8"AN, .090" PVB, 1/8" AN 2 2 13/16" LIG: 1/8" AN CAP, AIRSPACE, 1/8" AN, .090" PVB, 1/8" AN 2 3 13/16" LIG: 1/8" TP CAP, AIRSPACE, 1/8" AN, .090" PVB, 1/8" AN 3 4 1/8" HS, .090" PVB, 1/8" HS 4 5 3/16" AN, .090" PVB, 3/16" AN 4 6 13/16" LIG: 3/16" AN CAP, AIRSPACE, 1/8" AN, .090" PVB, 1/8" AN 4 7 13/16" LIG: 3/16" TP CAP, AIRSPACE, 1/8" AN, .090" PVB, 1/8" AN 4 8 3/16" AN, .090" SG, 3/16" AN 5 9 3/16" HS, .090" SG, 3/16" HS 5 10 13/16" LIG: 1/8" AN CAP, AIRSPACE, 1/8" HS, .090" SG, 1/8" HS 5 11 13/16" LIG 1/8" AN CAP, AIRSPACE, 3/16" AN, .090" SG, 3/16" AN 5 12 13/16" LIG: 1/8" TP CAP, AIRSPACE, 1/8" HS, .090" SG, 1/8" HS 5 13 13/16" LIG: 1/8" TP CAP, AIRSPACE, 3/16" AN, .090" SG, 3/16" AN 5 14 13/16" LIG: 3/16" AN CAP, AIRSPACE, 1/8" HS, .090" SG, 1/8" HS 5 15 13/16" LIG: 3/16" TP CAP, AIRSPACE, 1/8" HS, .090" SG, 1/8" HS 5 CODES /STANDARDS USED: •2017 FLORIDA BUILDING CODE (FBC), 6TH EDITION •ASTM E1300-09 •ANSI/AF&PA NDS-2015 FOR WOOD CONSTRUCTION •ALUMINUM DESIGN MANUAL, ADM-2015 •AISI S100-12 •AISC 360-10 DESIGN PRESSURE RATING IMPACT RATING VARIES PER GLASS TYPE, SEE SHEETS 2-5 LARGE & SMALL MISSILE IMPACT RESISTANT 52-1/8 MAX. BUCK WIDTH D, SEE _41 - SHEET 10 C, SEE SHEET 10 5" MAX. Q.C. 5" MAX. O.C. C D � 4-11/16" MAX. J 1" WEEP NOTCH AT EACH END ELEVATION FOR TYP. FIN FRAME SHOWN WITH EQUAL-LITE CONFIGURATION USER INSTRUCTIONS: 1) DETERMINE THE SITE SPECIFIC, WINDOW OPENING'S DESIGN PRESSURE REQUIREMENT FROM ASCE 7. 4-11/16" MAX. 83" MAX. BUCK HEIGHT 2) KNOWING YOUR GLAZING OPTION (TABLE 1), WINDOW CONFIGURATION AND SIZE, DETERMINE YOUR WINDOW S DESIGN PRESSURE FROM TABLES 2-5. IT MUST EQUAL OR EXCEED THE DESIGN PRESSURE REQUIREMENT FOR THE WINDOW OPENING OBTAINED IN STEP 1. 3) DETERMINE THE ANCHOR QUANTITY FROM TABLES 6 & 7. 4) INSTALL AS PER SHEET 7 FOR FLANGE INSTALLATION, SHEET 8 FOR EQUAL LEG INSTALLATION OR SHEET 9 FOR INTEGRAL FIN INSTALLATION. NOTE:DESIGN PRESSURE RATING DETERMINATION IS THE SAME PROCESS FOR ALL FRAME TYPES (FLANGE, INTEGRAL FIN OR EQUAL LEG/BOX). SG= KURARAY SENTRYGLAS® INTERLAYER BY KURARAY AMERICA, INC. PVB = KURARAY TROSIFOL® PVB INTERLAYER BY KURARAY AMERICA, INC. AN =ANNEALED HS = HEAT -STRENGTHENED TP =TEMPERED GENERAL NOTES ................................................. 1 ELEVATIONS......................................................... 1 DESIGN PRESSURES /GLAZING DETAILS........ 2-4 ANCHOR QUANTITIES .......................................... 5-6 INSTALLATION, FLANGE ...................................... 7 INSTALLATION, EQUAL LEG,''..., ...... I...................8 INSTALLATION, INTEGRAL FIN ............................ 9 EXTRUSION PROFILES ......................................... 10 ASSEMBLY & PARTS LIST... ................. a .... a .......... 11 LL1 z (n W O �j naN Io O o o w O Q a}oQ z � O O M � cn Z J O a� Z W O ^ O = LLI o �8 U UMOJQ ON W Z = Q J J W .-. Q SMa a Z O O IL U) O Z O Z Q � D J O L = W ® rn J C� w = Z aayS U) O Z O Q O H Z O I` w W ti U Z 2 J W U) Q (D al}!1 'asa0 sauaS ��•��ONY LYN/1/ * No. 58705me a * _ ST TE OF 4! �CORIOP.•'AL A. LYNN MILLER, P.E. P.E.# 58705 TART C 0- Bottom Sash Description for Gieen Range Sash Height Range in g Design Pressure (Ibs/ft2) for Glass Types 1 & 2 Tip to Tip Width 18" 25" 33" 37" 41" 45" 49" 53-1/8" 24" Equal-lite 12.464 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 Equal-lite 15.964 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 31" Standard Promew 12.994 - 15.963 +65.0 -80.0 +65.0 .80.0 +65.0 -80.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 Shortest 12.464 - 12.993 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Equal-lite 19.652 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Standard Proview 15.944 - 19.651 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -8&0 38-3/8" Custom Size 15.131 - 15.943 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Custom Size 14.131 - 15.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +6&0 -80.0 +65.0 .80.0 +65.0 -80.0 +65.0 80.0 +65.0 -80.0 Shortest 12.464 - 14.130 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 +65.0 -80.0 +65.0 80.0 +65.0 .80.0 Equal-lite 22.964 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 Custom Size 20.131 - 22.963 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Standard Promew 18.594 - 20.130 +65.0 -80.0 +6&0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 45" Custom Size 16.131 - 18.593 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 1 +65.0 -80.0 +65.0 -80.0 Custom Size 15.131 - 16.130 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 Custom Size 14.131 - 15.130 +65.0 .80.0 +65.0 -80.0 +65.0 .80.0 +65.0 .80.0 +65.0 -80.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 Shortest 12.464 - 14.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Equal-lite 24.964 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 +65.0 -80.0 Custom Size 22.131 - 24.963 +65.0 80.0 +65.0 -80.0 +65.0 -80.0 +65.0 80.0 +65.0 80.0 +65.0 80.0 +65.0 80.0 +65.0 80.0 Standard Proview 20.194 - 22.130 +65.0 -80.0 +65.0 -80.0 +65.0 80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 80.0 +65.0 80.0 49" Custom Size 18.131 - 20.193 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Custom Size 16.131 - 18.130 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Custom Size 14.131 - 16.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -77.6 Shortest 12A64 - 14.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -75.1 Equal-lite 25.777 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 o Custom Size 24.131 - 25.776 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 O Standard Proview 20.844 - 24.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 a Custom Size 20.131 - 20.843 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 50-5/8" Custom Size 18.131 - 20.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Custom Size 16.131 - 18.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -77.6 Custom Size 14.131 - 16.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -75.1 Shortest 12.464 - 14.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -73.9 Equal-lite 31.964 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Custom Size 28.131 - 31.963 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -77.6 Standard Promew 25.794 - 28.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -73.9 Custom Size 24.191 - 25.793 +65.0 -80.0 +65.0 80.0 +65.0 80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -72.7 63" Custom Size 22.131 - 24.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80. ++65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -78.8 +65.0 -70.5 Custom Size 20.131 - 22.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -77.1 +65.0 -68.4 Custom Size 18.131 -20.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -75.4 +65.0 -66.5 Custom Size 16.131 -18.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -77.1 +65.0 -73.8 +64.7 -64.7 Shortest 13.194* - 16.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -75.9 +65.0 -71.8 +65.0 -68.2 +62.3 -62.3 Equal-lite 38.464 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -73.9 Custom Size 36.131 - 38.463 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -79.8 +65.0 -71.6 Custom Size 34.131 - 36.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -77.9 +65.0 -69.4 76" Standard Promew 30.994 - 34.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -75.4 +65.0 -66.5 Custom Size 30.131 - 30.993 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -78.9 +65.0 -74.6 +65.0 -65.6 Custom Size 28.131 - 30.130 +65.0 j -80.0 j +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -79.1 +65.0 -75.3 +65.0 -71.9 +63.8 -63.8 Shortest 26.194* - 28.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -75.9 +65.0 -71.8 +65.0 -68.2 +62.3 -62.3 Equal-lite 42.464 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -77.9 +65.0 -69A 84" Custom Size 38.131 -42.463 +65.0 -80.0 +65.0 -8&0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -78.9 +65.0 -74.6 +65.0 -65.6 Standard Promew 34.194* - 38.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80. ++65.0 -80.0 +65.0 -75.9 +65.0 -71.8 +65.0 68.2 +62.3 62.3 *MINIMUM SASH HEIGHT FOR FLANGED WINDOWS IS: TIP TO TIP HEIGHT - 49.391 MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG WINDOWS IS: BUCK HEIGHT - 48.391 MINIMUM SASH HEIGHT FOR FLANGED, RADIUS TOP WINDOWS IS: TIP TO TIP HEIGHT - 49.806 MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG, RADIUS TOP WINDOWS IS: BUCK HEIGHT - 48.806 1) TIP TO TIP DIMENSIONS SHOWN. FOR INTEGRAL FIN AND EQUAL -LEG WINDOWS, SUBTRACT 1" FROM THE TIP TO TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. 2) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE SIZE. 3) FOR RADIUS TOP WINDOWS, FIND THE SMALLEST WINDOW SIZE IN THE TABLE ABOVE WHICH THE RADIUS TOP WINDOW WILL COMPLETELY FIT WITHIN. 4) WINDOWS WITH THE LOW SILL OPTION ARE LIMITED TO A MAXIMUM POSITIVE DESIGN PRESSURE OF +65 PSF. NEGATIVE DESIGN PRESSURES ARE UNAFFECTED. 090" 34 I� GLASS STACK 1 /8" AN GLASS /8" AN GLASS GLASS TYPE 1 AIRSPACE 1/8"AN GLASS 31 5�OR 2C°. EXTERIOR a 35 OR(3 75 13/16" NOM. GLASS STACK 090' PVB 1 /8" AN GLASS 75 1/2" NOM. GLASS BITE ( 70-73 ) GLASS TYPE 2 AN=ANNEALED TP=TEMPERED HS= HEAT STRENGTHENED O Y L11 Z z U) vi w O q Q Aa� ❑ !�- O (n ti o LU w O Q a}o0 U' N Z I � O O M LU U) Z J O a. U) Z O _ W o = W N0 J WF- UMOJQ ON � z = Q J J W .-. Q OMO Z O U Z C� Z ILL O = N ® N J 0 = Z aaUS U) O D J 0 Z m 0 0 w ~ ❑ _ U J CIL U) Q ❑ // �sa0 sauaS TADI C'2 Bottom Sash Description for Gisen Range Sash Height Range in g Design Pressure (lbs/ft2) for Glass Type 3 Tip to Tip Width 18" 25" 33" 37" 41" 45" 49" 53-1/8" 24" Equal-lite 12.464 +65.0 -80.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 80.0 +65.0 -80.0 +65.0 -80.0 Equal-lite 15.964 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 31" Standard Pro\�iew 12.994 - 15.963 +65.0 -80.0 +65.0 -80.0 +65.0 80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Shortest 12.464 - 12.993 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Equal-lite 19.652 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -8&0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Standard Promew 15.944 - 19.651 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 1 +65.0 .80.0 +65.0 -80.0 38-3/8" Custom Size 15.131 - 15.943 +65.0 -80.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 Custom Size 14.131 - 15.130 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 Shortest 12.464 - 14.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 Equal-lite 22.964 +65.0 -80.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Custom Size 20.131 - 22.963 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Standard ProHew 18.594 - 20.130 +65.0 -80.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 45" Custom Size 16.131 - 18.593 +65.0 80.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 1 +65.0 -80.0 +65.0 -80.0 Custom Size 15.131 - 16.130 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 80.0 Custom Size 14.131 - 15.130 +65.0 80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Shortest 12.464 - 14.130 +65.0 -80.0 +65.0 .80.0 +65.0 -80.0 +65.0 .80.0 +65.0 .80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Equal-lite 24.964 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Custom Size 22.131 - 24.963 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Standard Pro\iew 20.194 - 22.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 .80.0 49" Custom Size 18.131 - 20.193 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Custom Size 16.131 - 18.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Custom Size 14.131 - 16.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 r Shortest 12.464 - 14.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Equal-lite 25.777 +65.0 -80.0 +65.0 80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 = n Custom Size 24.131 - 25.776 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 F 0 Standard Proview 20.844 - 24.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 a Custom Size 20.131 - 20.843 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 F. 50-5/8" Custom Size 18.131 - 20.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Custom Size 16.131 - 18.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Custom Size 14.131 - 16.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Shortest 12.464 - 14.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Equal-lite 31.964 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -BO.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Custom Size 28.131 - 31.963 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Standard Proview 25.794 - 28.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Custom Size 24.131 - 25.793 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 63" Custom Size 22.131 - 24.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Custom Size 20.131 - 22.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -78.0 Custom Size 18.131 - 20.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -75.8 Custom Size 16.131 - 18.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -73.8 Shortest 13.194* - 16.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -77.7 +65.0 -71.0 Equal-lite 38.464 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Custom Size 36.131 - 38.463 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 Custom Size 34.131 - 36.130 +65.0 -80.0 +65.0 80.0 +65.0 80.0 +65.0 80.0 +65.0 80.0 +65.0 80.0 +65.0 80.0 +65.0 79.1 76" Standard Pro\Aew 3a994 - 34.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -75.8 Custom Size 30.131 - 30.993 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -74.8 Custom Size 28.131 - 30.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -72.7 Shortest 26.194* - 28.130 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -77.7 +65.0 -71.0 Equal-lite 42.464 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -79.1 84" Custom Size 38.131 - 42.463 +65.0 -80.0 +65.0 1 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -74.8 Standard Proview 34.194* - 38.130 +65.0 80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -80.0 +65.0 -77.7 +65.0 -71.0 *MINIMUM SASH HEIGHT FOR FLANGED WINDOWS IS: TIP TO TIP HEIGHT - 49.391 MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG WINDOWS IS: BUCK HEIGHT - 48.391 MINIMUM SASH HEIGHT FOR FLANGED, RADIUS TOP WINDOWS IS: TIP TO TIP HEIGHT - 49.806 MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG, RADIUS TOP WINDOWS IS: BUCK HEIGHT - 48.806 1) TIP TO TIP DIMENSIONS SHOWN. FOR INTEGRAL FIN AND EQUAL -LEG WINDOWS, SUBTRACT 1"FROM THE TIP TO TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. 2) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE SIZE. 3) FOR RADIUS TOP WINDOWS, FIND THE SMALLEST WINDOW SIZE IN THE TABLE ABOVE WHICH THE RADIUS TOP WINDOW WILL COMPLETELY FIT WITHIN. 4) WINDOWS WITH THE LOW SILL OPTION ARE LIMITED TO A MAXIMUM POSITIVE DESIGN PRESSURE OF +65 PSF. NEGATIVE DESIGN PRESSURES ARE UNAFFECTED. AIRSPACE GLASS- 31 13/16" IN I GLASS STACK 090' PVB 1/8" AN GLASS 75 1/2" NOM. GLASS BITE 70J3 GLASS TYPE 3 AN=ANNEALED TP=TEMPERED HS= HEAT STRENGTHENED Y 111 Z ? U) w p nay � � O O U) = Lu = O r' a]oa CO CV z 0 O O M � U) Z O O Z c4 ro~ x W -I O r� Lll r N 0 �8 U O UMDJa ON W J Z ¢ J c� Q SMO F� Z O U Z _ � O � Z LL. O 2 c+) ® rn J 04 C� Z aayS = H U) LL O D J 0 Z m 0 w F _ U J U) Q a�}�l 'asaQ sa�JaS No.58705 ST TE OF � ` � (r .P4ORiOrk A. LYNN MILLER, P.E. P.E.# 58705 TART F d Design Pressure (lbs/ft2) for Glass Types 4-7 Bottom Sash Description for Given Range Sash Height Range (in) Tip To Tip Width 24" Equal-lite 12.464 +65.0 -80.0 Equal-lite 15.964 +65.0 -80.0 31" Standard Proview 12.994 - 15.963 +65.0 -80.0 Shortest 12.464 - 12.993 +65.0 -80.0 Equal-lite 19.652 +65.0 -80.0 Standard Proview 15.944 - 19.651 +65.0 -80.0 38-3/8" Custom Size 15.131 - 15.943 +65.0 -80.0 Custom Size 14.131 - 15.130 +65.0 -80.0 Shortest 12.464 - 14.130 +65.0 -80.0 Equal-lite 22.964 +65.0 -80.0 Custom Size 20.131 - 22.963 +65.0 -80.0 Standard Proview 18.594 - 20.130 +65.0 -80.0 45" Custom Size 16.131 - 18.593 +65.0 -80.0 Custom Size 15.131 - 16.130 +65.0 -80.0 Custom Size 14.131 - 15.130 +65.0 -80.0 Shortest 12.464 - 14.130 +65.0 -80.0 Equal-lite 24.964 +65.0 -80.0 Custom Size 22.131 - 24.963 +65.0 -80.0 Standard Proview 20.194 - 22.130 +65.0 -80.0 49" Custom Size 18.131 - 20.193 +65.0 -80.0 Custom Size 16.131 - 18.130 +65.0 -80.0 Custom Size 14.131 -16.130 +65.0 -80.0 S hortest 12.464 - 14A 30 +65.0 -80.0 Equal-lite 25.777 +65.0 -80.0 = Custom Size 24.131 - 25.776 +65.0 -80.0 ~ 0 Standard Proview 20.844 - 24.130 +65.0 -80.0 n 50-5/8" Custom Size 20.131 - 20.843 +65.0 -80.0 i- Custom Size 18.131 - 20.130 +65.0 -80.0 Custom Size 16A31 -18.130 +65.0 -80.0 Custom Size 14.131 - 16.130 +65.0 -80.0 Shortest 12.464 - 14.130 +65.0 -80.0 Equal-lite 31.964 +65.0 -80.0 Custom Size 28.131 - 31.963 +65.0 -80.0 Standard Proview 25.794 - 28.130 +65.0 -80.0 Custom Size 24.131 -25.793 +65.0 -80.0 63" Custom Size 22.131 - 24.130 +65.0 -80.0 Custom Size 20.131 - 22.130 +65.0 -80.0 Custom Size 18.131 - 20.130 +65.0 -80.0 Custom Size 16.131 - 18.130 +65.0 -80.0 Shortest 13.194* - 16.130 +65.0 -80.0 Equal-lite 38.464 +65.0 -80.0 Custom Size 36.131 - 38A63 +65.0 -80.0 Custom Size 34.131 - 36.130 +65.0 -80.0 76" Standard Proview 30.994 - 34.130 +65.0 -80.0 Custom Size 30.131 - 30.993 +65.0 -80.0 Custom Size 28.131 - 30.130 +65.0 -80.0 Shortest 26.194* - 28.130 +65.0 -80.0 Equal-lite 42.464 +65.0 -80.0 84" Custom Size 38.131 -42A63 +65.0 -80.0 Standard PrmAew 34.194* - 38.130 +65.0 -80.0 ® 5/16" NOM. GLASS STACK .090" PVB 1/8" HS GLASS 30 1/8" H$ GLASS 26 Ir 1/2" NOM. EXTERIOR GLASS BITE 74 34 GLASS TYPE 4 .090" PVB 30 27 EXTERIOR a 7/16" NOM. GLASS STACK 3/16" AN GLASS 3/16" T GLASS 1/2" NOM. GLASS BITE 34 GLASS TYPE 5 AIRSPACE 3/16" AN GLAD' 31 EXTERIOR a 74 13/16" NOM. GLASS STACK �QT 090" PVB /8" AN�GLASS �--F174 J NOM. GLASS BITE 35 OR 35B GLASS TYPE 6 AIRSPACE 3/16" TP GLASS - 31 5 )OR 58 EXTERIOR a 35 OR 35B I� 13/16" NOM. GLASS STACK 090" PVB 1/8" AN GLASS 74 i 1/2" NOM. GLASS BITE GLASS TYPE 7 TABLE 5: Design Pressure for Glass Types 8=15 Bottom Sash Description for Given Range Sash Height Range (in) Tip To Tip Width 53-1/8" 24" Equal-lite 12.464 +80.0 -110.0 Equal-lite 15.964 +80.0 -110.0 31" Standard Proview 12.994 - 15.963 +80.0 -110.0 Shortest 12.464 - 12.993 +80.0 -110.0 Equal-lite 19.652 +80.0 -110.0 Standard Proview 15.944 - 19.651 +80.0 -110.0 38-3/8" Custom Size 15.131 - 15.943 +80.0 -110.0 Custom Size 14.131 - 15.130 +80.0 -110.0 Shortest 12.464 - 14.130 +80.0 -110.0 Equal-lite 22.964 +80.0 -110.0 Custom Size 20.131 - 22.963 +80.0 -110.0 Standard Proview 18.594 - 20.130 +80.0 .110.0 45" Custom Size 16.131 - 18.593 +80.0 -110.0 Custom Size 15.131 -16.130 +80.0 -110.0 Custom Size 14.131 - 15.130 +80.0 -110.0 Shortest 12.464 - 14.130 +80.0 -110.0 Equal-lite 24.964 +80.0 -110.0 Custom Size 22.131 - 24.963 +80.0 -110.0 Standard Proview 20.194 - 22.130 +80.0 -110.0 49" Custom Size 18.131 - 20.193 +80.0 -110.0 Custom Size 16.131 - 18.130 +80.0 -110.0 Custom Size 14.131 - 16.130 +g0.0 -110.0 r Shortest 12.464 - 14.130 +80.0 -110.0 Equal-lite 25.777 +80.0 -110.0 = a Custom Size 24.131 - 25.776 +g0.0 -110.0. ~ 0 Standard Proview 20.844 - 24.130 +80.0 -110.0 0 50-5/8" Custom Size 20.131 - 20.843 +80.0 -110.0 Custom Size 18.131 -20.130 +80.0 -110.0 Custom Size 16.131 - 18.130 +80.0 -110.0 Custom Size 14.131 - 16.130 +80.0 -110.0 Shortest 12.464 - 14.130 +80.0 -110.0 Equal-lite 31.964 +80.0 -110.0 Custom Size 28.131 - 31.963 +80.0 -110.0 Standard Proview 25.794 - 28.130 +80.0 -110.0 Custom Size 24.131 - 25.793 +g0.0 -110.0 63" Custom Size 22.131 - 24.130 +80.0 -110.0 Custom Size 20.131 - 22.130 +80.0 -110.0 Custom Size 18.131 - 20.130 +80.0 -110.0 Custom Size 1&131 - 18.130 +80.0 -110.0 Shortest 13.194* - 16.130 +80.0 -110.0 Equal-lite 38.464 +80.0 -110.0 Custom Size 36.131 - 38.463 +80.0 -110.0 Custom Size 34.131 - 36.130 +80.0 -110.0 76" Standard Proview 30.994 - 34.130 +80.0 -110.0 Custom Size 30.131 - 30.993 +80.0 -110.0 Custom Size 28.131 - 30.130 +80.0 -110.0 Shortest 26.194* - 28.130 +80.0 -110.0 Equal-lite 42.464 +80.0 -110.0 84" Custom Size 38.131 - 42.463 +80.0 -110.0 Standard Pro\hew 34.194* - 38.130 +80.0 -110.0 *MINIMUM SASH HEIGHT FOR FLANGED WINDOWS IS: TIP TO TIP HEIGHT - 49.391 MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG WINDOWS IS: BUCK HEIGHT - 48.391 MINIMUM SASH HEIGHT FOR FLANGED, RADIUS TOP WINDOWS IS: TIP TO TIP HEIGHT - 49.806 MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG, RADIUS TOP WINDOWS IS: BUCK HEIGHT - 48.806 3/16" AN GLASS 3/16" HS GLASS 090" SG 090" SG 30 3/16" A� GLASS 1$7 3/16" H� GLASS 26 1/2" NOM.1/2" NOM. EERIOR GLASS BITE EXTEGLASS BITE a a 74 74 34 GLASS TYPE 8 GLASS TYPE 9 13/16" NOM. �~ 13/16" NOM. GLASS STACK GLASS STACK 090" SG 090" SG AIRSPACE AIRSPACE 1/8" AN GLA 1/8" HS GLASS 1/8" AN GLASS 3/16" AN GLASS XCC 31 74 I SA OR. Z5 OR 5B 1/2" NOM. EXTERITE EXTERIOR GLASS BITE aa 35 O35 OR 35B 70-73 GLASS TYPE 11 Imo_ 13/16'GLASS NOM. Imo- 13/16" NOM. GLASS STACK GLASS STACK 7 090" SG .090" SG AIRSPACE AIRSPACE 1/8" TP GLASS 11�1/8" HS GLASS 1/8" TP GLASS 3/16" AN GLASS 31 74 t35B KIACC S�OR 5B 1/2" NOM. 5@OR EXTERIOR GLASS BITE EXTERIE a a 70-73 35 OR 35B 35 O GLASS TYPE 12 13116" NOM. 13/16" NOM. GLASS STACK GLASS STACK 090" SG .090" SG AIRSPACE AIRSPACE 3/16" AN GLASS 1/8" HS GLASS 3/16" TP GLASS 1/8" HS GLASS 31 74 31 74 5�oR 5B 1/2" NOM. S@OR 5B 1/2" NOM. EXTERIOR GLASS BITE EXTERIOR GLASS BITE a a 35 OR 35B 70 73 35 OR 35B 70-73 GLASS TYPE 14 GLASS TYPE 15 1) TIP TO TIP DIMENSIONS SHOWN. FOR INTEGRAL FIN AND EQUAL -LEG WINDOWS, SUB' RACT 1" FROM THE TIP TO TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. 2) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE SIZE. 3) FOR RADIUS TOP WINDOWS, FIND THE SMALLEST WINDOW SIZE IN THE TABLE ABOVE WHICH THE RADIUS TOP WINDOW WILL COMPLETELY FIT WITHIN. 4) WINDOWS WITH THE LOW SILL OPTION ARE LIMITED TO A MAXIMUM POSITIVE DESIGN PRESSURE OF +65 PSF. NEGATIVE DESIGN PRESSURES ARE UNAFFECTED. AN=ANNEALED TP= TEMPERED HS= HEAT STRENGTHENED a0 Y W Z ? (n > w C) O > > nab O U) LLI CV Z w O M LU rn Z Oz J O n- u) Z O _ W O = LLI WU @ uMoaO 9Ma 000 w J Q Z O U Z _ C LL O c0 = ® LU N J oi 3 = Z aayS H U) O D J 00 Z m ~ w F � ~ = _ U J d U) a< �as�a0 sauaS i _ No. 58705 eve 4� S ATEOF (v ••.PCOR19P.*so / s®®NAB.- t� A. LYNN MILLER, P.E. P.E.# 58705 TART F R, Anchor Quantities Required for "Through -Frame" Installation using Glass Types 1-7 Tip to Tip Width 18° 2s" 33° 3711 4111 4511 49" 53-1/8" Jamb = Jamb Jamb Jamb a) Jamb a5 Jamb a `) Jamb `) a Jamb a CID Bottom Sash Description for Given Range Sash HeightTccoo Range (in) > o= a Q g 3>> m m o= a ¢ g 0 m o= a ¢ T m 2�� 4) o -0 ¢ Of 3 o= a) m Ir o= a ¢ tr 3 a) m tr o= a Q r g 3 a) Co 2i o_ .o Q 3 a) m 2 1 2 2 1 2 2 1 2 2 1 2 2 24" Equal-lite 12.464 1 2 1 1 2 1 1 2 1 1 2 Equal-lite 15.964 1 2 1 1 2 1 1 2 1 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 31" Standard Proview 12.994 - 15.963 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 3 2 2 2 Shortest 12.464 - 12.993 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Equal-lite 19.652 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Standard Proview 15.944 - 19.651 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 38-3/8" Custom Size 15.131 - 15.943 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Custom Size 14.131 - 15.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Shortest 12.464 - 14.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Equal-lite 22.964 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Custom Size 20.131 - 22.963 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Standard Proview 18.594 - 20.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 45" Custom Size 16.131 - 18.593 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Custom Size 15.131 - 16.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Custom Size 14.131 - 15.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Shortest 12.464 - 14.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 Equal-lite 24.964 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Custom Size 22.131 - 24.963 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Standard Proview 20.194 - 22.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 49" Custom Size 18.131 - 20.193 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Custom Size 16.131 - 18.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 Custom Size 14.131 - 16.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 Shortest 12.464 - 14.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 Equal-lite 25.777 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 = Custom Size 24.131 - 25.776 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 ~ 0 Standard Proview 20.844 - 24.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 o- Custom Size 20.131 - 20.843 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 H 50-s/8" Custom Size 18.131 - 20.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 Custom Size 16.131 - 1&130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 Custom Size 14.131 - 16.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 Shortest 12.464 - 14.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 Equal-lite 31.964 2 3 1 2 3 1 2 3 1 2 3 2 2 3 2 2 3 2 2 3 2 2 3 2 Custom Size 28.131 - 31.963 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 Standard Proview 25.794 - 28.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 3 2 Custom Size 24.131 - 25.793 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 63" Custom Size 22.131 - 24.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 Custom Size 20.131 - 22.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 Custom Size 18.131 - 20.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 Custom Size 16.131 - 18.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 Shortest 13.194* - 16.130 4 2 1 4 2 1 4 2 1 4 2 2 4 2 2 4 2 2 4 2 2 4 2 2 Equal-lite 38.464 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 Custom Size 36.131 - 38.463 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 Custom Size 34.131 - 36.130 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 76" Standard Proview 30.994 - 34.130 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 Custom Size 30.131 - 30.993 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 11 2 3 3 2 3 3 2 Custom Size 28.131 - 30.130 3 3 1 3 3 1 3 3 1 3 3 2 3J32 3 3 2 3 3 2 3 3 2 Shortest 26.194* - 28.130 4 2 1 4 2 1 4 2 1 4 2 2 4 4 2 2 4 2 2 4 3 2 Equal-lite 42.464 3 4 1 3 4 1 3 4 1 3 4 2 3 3 4 2 3 4 2 3 4 284" Custom Size 38.131 - 42.463 3 4 1 3 4 1 3 4 1 3 4 2 3 3 4 2 3 4 2 3 4 2 Standard Proview 34.194* - 38.130 4 3 1 4 3 1 4 3 1 4 3 24 4 3 2 4 3 2 4 3 2 *MINIMUM SASH HEIGHT FOR FLANGED WINDOWS IS: TIP TO TIP HEIGHT - 49.391 MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG WINDOWS IS: BUCK HEIGHT - 48.391 MINIMUM SASH HEIGHT FOR FLANGED, RADIUS TOP WINDOWS IS: TIP TO TIP HEIGHT - 49.806 MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG, RADIUS TOP WINDOWS IS: BUCK HEIGHT - 48.806 Glass Type Description (Listed from Exterior to Interior) 1 1/81AN2 .090" PVB, 1/8" AN 2 13/16" LIG: 1/8" AN CAP, AIRSPACE, 1/8" AN, .090" PVB, 1/8" AN 3 13/16" LIG: 1/8" TP CAP, AIRSPACE, 1/8" AN, .090" PVB, 1/8" AN 4 1/8" HS, .090" PVB, 1/8" HS 5 3/16" AN, .090" PVB, 3/16" AN 6 13/16" LIG: 3/16" AN CAP, AIRSPACE, 1/8" AN, .090" PVB, 1/8" AN 7 13/16" LIG: 3/16" TIP CAP, AIRSPACE, 1/8" AN, .090" PVB, 1/8" AN 1) TIP TO TIP DIMENSIONS SHOWN. FOR INTEGRAL FIN AND EQUAL -LEG WINDOWS, SUBTRACT 1" FROM THE TIP TO TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. 2) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE SIZE. 3) FOR RADIUS TOP WINDOWS, FIND THE SMALLEST WINDOW SIZE IN THE TABLE ABOVE WHICH THE RADIUS TOP WINDOW WILL COMPLETELY FIT WITHIN. 4) WINDOWS WITH THE LOW SILL OPTION ARE LIMITED TO A MAXIMUM POSITIVE DESIGN PRESSURE OF +65 PSF. NEGATIVE DESIGN PRESSURES ARE UNAFFECTED. O LL1 ? U) w O �j na{ it U) O }D � 0 Q a}oa N z � (n Z OZ J O CD EL W Cl) Z LLI O co _ ^ O = LLI N 0 U UMOJQ 'ON W Z = Q J J W ^ c9 Q HMO Z U Z J � m LL• �_ < O to L0 ® rn J H C ~ = Z Z aa4S CY O 0 Z U U = J Z (A Q Q al}!1 asao sauas \\11111111/�// �'�`Z` •' �IGENgF ����� Off No. 58705 _ �® UTOF�4�\ '• '•'�<ORiOP.•' N�� //lIIII11\\\ A. LYNN MILLER, P.E. P.E.# 58705 TARI F 7- Anchor Quantities Required for "Through -Frame" Installation u ing Glass Types 8-15 Tip to Tip Width 18" 25" 33" 37" 41" 45" 49" 53-1/8" Jamb > 3 o= s a) QQ o 0> Jamb 0ri Jamb ro = Jamb oa a)> Jamb a 0 Jamb aa) = Jamb 0> Jamb 0 Bottom Sash Description for Given Range Sash Height Range (in) o .0 3 o= a) m o= s Q 3 a) m o= .0 ¢ 3 a) m o Q 3 o m o Q 3 o= Co o_ Q 3 Co 24" Equal-lite 12.464 1 2 1 1 2 1 1 2 1 1 2 2 1 2 2 1 2 2 1 2 2 Equal-lite 15.964 1 2 1 1 2 1 1 2 1 1 2 2 1 2 2 1 2 2 1 2 2 31" Standard Pro\iew 12.994 - 15.963 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 Shortest 12.464 - 12.993 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 f22 2 2 2 Equal-lite 19.652 2 2 1 2 2 1 2 2 1 2 2 2 2 t22 2 2 2 2 2 2 Standard Pro\Aew 15.944 - 19.651 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 38-3/8" Custom Size 15.131 - 15.943 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 Custom Size 14.131 - 15.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 1 2 1 2 2 2 Shortest 12.464 - 14.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Equal-lite 22.964 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 3 2 2 3 2 Custom Size 20.131 - 22.963 2 2 1 2 2 1 2 2 1 2 2 2 1 2 2 2 2 2 2 2 3 2 2 3 2 Standard Pro\Aew 18.594 - 20.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 3 2 45" Custom Size 16.131 - 18.593 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 Custom Size 15.131 - 16.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 Custom Size 14.131 - 15.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 Shortest 12.464 - 14.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 3 Equal-lite 24.964 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 3 2 2 3 2 2 3 2 Custom Size 22.131 - 24.963 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 3 2 2 3 2 2 3 2 Standard ProHew 20.194 - 22.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 3 2 2 3 3 49" Custom Size 18.131 - 20.193 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 Custom Size 16.131 - 18.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 3 Custom Size 14.131 - 16.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 3 2 3 L Shortest 12.464 - 14.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 3 2 3 Equal-lite 25.777 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 3 2 2 3 2 2 3 2 n. Custom Size 24.131 - 25.776 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 3 2 2 3 2 2 3 2 ~ Standard Promew 20.844 - 24.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 3 2 2 3 2 2 3 3 n Custom Size 20.131 - 20.843 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 50-5/8" Custom Size 18,131 - 20.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 3 3 Custom Size 16.131 - 18.130 3 2 1 3 2 1 3 2 1 3 1 2 1 2 3 2 2 3 2 2 1 3 2 3 3 2 3 Custom Size 14.131 - 16.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 3 2 3 Shortest 12.464 - 14.130 3 1 2 1 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 3 2 3 Equal-lite 31.964 2 3 1 2 3 1 2 3 1 2 3 2 2 3 2 2 3 2 2 3 2 2 4 3 Custom Size 28.131 - 31.963 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 3 3 4 3 Standard Pro\Aew 25.794 - 28.130 3 2 1 3 2 1 3 2 1 3 2 2 3 3 2 3 3 2 3 3 3 3 3 3 Custom Size 24.131 - 25.793 3 2 1 3 2 1 3 2 1 3 2 2 3 3 2 3 3 2 3 3 3 3 3 3 63" Custom Size 22.131 - 24.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 3 2 3 3 3 3 3 3 Custom Size 20.131 - 22.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 3 3 3 3 3 Custom Size 18.131 - 20.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 4 3 3 Custom Size 16.131 - 18.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 4 2 3 4 2 3 Shortest 13.194* - 16.130 4 2 1 4 2 1 4 2 1 4 2 2 4 2 2 4 2 2 4 4 2 3 Equal-lite 38.464 3 3 1 3 3 1 3 3 1 3 3 2�jj 3 3 2 3 4 2 3 3 4 3 Custom Size 36.131 - 38.463 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 4 2 3 t43 3 4 3 Custom Size 34.131 - 36.130 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 4 2 3 3 4 3 76" Standard Pro\Aew 30.994 - 34.130 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 4 4 3 Custom Size 30.131 - 30.993 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 4 4 4 3 Custom Size 28.131 - 30.130 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 4 3 2 4 3 3 4 4 3 Shortest 26.194* - 28.130 4 2 1 4 2 1 4 2 1 4 2 2 4 3 2 4 3 2 4 3 3 4 3 3 Equal-lite 42.464 3 4 1 3 4 1 3 4 1 3 4 2 3 4 2 3 4 2 3 4 3 3 5 3 84" Custom Size 38.131 - 42.463 3 4 1 3 4 1 3 4 1 3 4 2 3 4 2 3 4 2 4 4 3 4 5 3 Standard Promew 34.194" - 38.130 4 3 1 4 3 1 4 3 1 4 3 2 4 3 2 4 4 2 4 4 3 4 4 3 *MINIMUM SASH HEIGHT FOR FLANGED WINDOWS IS: TIP TO TIP HEIGHT - 49.391 MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG WINDOWS IS: BUCK HEIGHT - 48.391 MINIMUM SASH HEIGHT FOR FLANGED, RADIUS TOP WINDOWS IS: TIP TO TIP HEIGHT - 49.806 MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG, RADIUS TOP WINDOWS IS: BUCK HEIGHT - 48.806 TARI F 7R Glass Type Description (Listed from Exterior to Interior) 8 3/16" AN, .090" SG, 3116" AN 9 3/16" HS, .090" SG, 3/16" HS 10 13/16" LIG: 1/8" AN CAP, AIRSPACE, 1/8" HS, .090" SG, 1/8" HS 11 13/16" LIG: 1/8" AN CAP, AIRSPACE, 3/16" AN, .090" SG, 3/16" AN 12 13/16" LIG: 1/8" TP CAP, AIRSPACE, 1/8" HS, .090" SG, 1/8" HS 13 13/16" LIG: 1/8" TP CAP, AIRSPACE, 3/16" AN, .090" SG, 3/16" AN 14 13/16" LIG: 3/16" AN CAP , AIRSPACE, 1/8" HS, .090" SG, 1/8" HS 15 13/16" LIG: 3/16" TP CAP, AIRSPACE, 118" HS, .090" SG, 1/8" HS 1) TIP TO TIP DIMENSIONS SHOWN. FOR INTEGRAL FIN AND EQUAL -LEG WINDOWS, SUBTRACT 1"FROM THE TIP TO TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. 2) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE SIZE. 3) FOR RADIUS TOP WINDOWS, FIND THE SMALLEST WINDOW SIZE IN THE TABLE ABOVE WHICH THE RADIUS TOP WINDOW WILL COMPLETELY FIT WITHIN. 4) WINDOWS WITH THE LOW SILL OPTION ARE LIMITED TO A MAXIMUM POSITIVE DESIGN PRESSURE OF +65 PSF. NEGATIVE DESIGN PRESSURES ARE UNAFFECTED. O L11 ? U) w O �j nab O 0 Ho Op =o uj � O Q a}oQ U' N z Lu O O M 07 Z OZ J O EL Cl) Z O co `D _ ^ o = W N0 J r g U � UMOJQ ON W oo J Z 0 Q J J `)MO Z O U Z - W m U. < O ® J H C\j O ~ aay5 Z ZQ = H O Q < O 0 Z O 0 w � _ ~ v U 2 J Z (n Q Q aI}il asaQ sauas / \,\GENS _ No. 58705 USTF F�ORIDP • ��°ev \ i is '••..... � ZONAL �- �!NA1�� A. L / MILLER\P.E. P.E.# 58705 INSTALLATION OPTION 1 ANCHORED THROUGH FRAME INTO 2X WOOD FRAME OR BUCKSTRIP. SEE NOTE 2, THIS SHEET. TIP TO TIP HEIGHT 27 EDGE DISTANCE 10 FIXED VISIBLE LIGHT HEIGHT be I)� 43 32 EMBED,, I MENT EDGE r DISTANCE 1/4" MAX SHIM 1 1 SEE TABLE NOTE B, FOR / HEAD TYPE TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE,SEE TABLE 8. TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUE SEE SASH VISIBLE LIGHT HEIGGHT 1 EXTERIOR i a 33 10 15 OPTIONAL HI -RISE SILL SHOWN. SEE 1" WEEP 42 SHEET 10 FOR NOTCH AT STANDARD SILL. EACH END 1/4 11 MAX. SHIM REQUIRED IN FLANGE OR a m EQUAL -LEG a FRAME SILLS VERTICAL SECTION B-B r e�i-. ■3s?0 INSTALLATION OPTION 2 ANCHORED THROUGH FRAME DIRECTLY INTO CONCRETE/CMU. EMBEDMENT 1/4" MAX SHIM 4 6 al ilk I Le ANCHORED THROUGH FRAME AND 1X BUCKSTRIP INTO CONCRETE/CMU. SEE NOTE 2, THIS SHEET. 1/4" MAX SHIM —► I►— SASH VISIBLE � 17 LIGHT WIDTH a 19 FIXED VISIBLE 7 L I LIGHT WIDTH [ ° e 44 d a ° 31 5 OR 5B T^^ ^^ TIP TO TIP WIDTH HORIZONTAL SECTION A -A SHIM DADE APPROVED MULLION, FBC COMPLIANT ALUMINUM/STEEL FRAMING OR STEEL STUD. MAY BE VERTICAL OR HORIZONTAL. SEE SUBSTRATE PROPERTIES, TABLE 8. INSTALLATION OPTION 4 ANCHORED THROUGH FRAME INTO METAL Anchor Substrate Min. Edge Distance Min. Embedment P.T. Southern Pine (SG=0.55) 9/16 1-3/8" #12 Steel, Aluminum, 6063-T5 min. 3/8" 0,063" 18-8 or 410 SS Screw A36 Steel 3/8" 0.063" Steel Stud, Gr. 33 min. 3/8" 0,045" (18 Ga) Concrete (min. 3.35 ksi) 1" 1=3/4" SS CeF Ungrouted CMU, (ASTM C-90) 2-1/2" 1-1/4" reteFlex P.T. Southern Pine (SG=0.55) 1" 1-3/8" Concrete (min. 2.85 ksi) been 1" 1,,3/8" 1/4" Steel Ultracon Ungrouted CMU, (ASTM C0,90) 2-1/2" 1-1/4" P.T. Southern Pine (SG=0.55) 1" 1-3/8" A) IN. OF 3 THREADS BEYOND THE METAL SUBSTRATE. B) USE ONLY FLATHEAD ANCHORS IN JAMBS, PAN/HEX/FLAT HEAD TYPE IS ALLOWABLE FOR ANCHORS IN THE HEAD. C) "UNGROUTED CMU" VALUES MAY BE USED FOR GROUTED CMU APPLICATIONS. EMBEDMENT d° EDGE DISTANCE d l° s d a ° 4 TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 8. VISIBLE LIGHT FORMULAS: (SHOWN FOR HI -RISE SILL; SEE SHEET 9 FOR STANDARD SILL) WIDTH @ SASH &FIXED LITE: TIP TO TIP WIDTH - 5.12" HEIGHT (EQUAL-LITE) TIP TO TIP HEIGHT/2 be 3.73" HEIGHT (PROVIEW) @FIXED LITE: TIP TO TIP HEIGHT/2 + 3.78" @SASH: TIP TO TIP HEIGHT/2 be 11.93" HEIGHT (CUSTOM SASH) @FIXED LITE: TIP TO TIP HEIGHT - SASH HEIGHT - 3.55" @SASH: SASH HEIGHT -4.60" NOTES: 1) USE ONLY SUBSTRATE -APPROPRIATE ANCHORS LISTED ON TABLE 8. FOLLOW EMBEDMENT AND EDGE DISTANCE LIMITS. ANY INSTALLATION OPTION SHOWN MAY BE USED ON ANY SIDE OF THE WINDOW. 2) MASONRY ANCHORS MAY BE USED INTO WOOD AS PER TABLE 8. ALL WOOD BUCKS LESS THAN 1-1/2" THICK ARE TO BE CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2" THICK OR GREATER. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. WOOD BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD, 3) VISIBLE LIGHT WIDTH OR HEIGHT (ALSO REFERRED TO AS DAYLIGHT OPENING) IS MEASURED FROM BEADING TO BEADING. rb W z U) r w Op O nay o O a�oa (� N z LU Q O M LU U) Oz O J O EL u Z O �= ^ � w o U O UMDJa 'ON W OO J Z = Q J J W Q DMO IL U) Z o Z CD Z L- O _� ~ ® rn N W Z rn J (D _ H Z U aays U) D U) L X o z W O _ � z LLJ U J J U) Q u_ @W1 :)saQ saua5 \\IIIIIP/t, �S .• \�\CENSF' No.58705Web 4ij ' ®'. A OF � 4. so ''.FZORIDR.•' \� ss®®AL ��t/11111I\\ie A. LYNN MILLER, P.E. P.E.# 58705 INSTALLATION OPTION 1 ANCHORED THROUGH FRAME INTO 2X WOOD FRAME OR BUCKSTRIP. SEE NOTE 2, THIS SHEET. BUCK HEIGHT NO ANCHORS REQUIRED IN FLANGE OR EQUAL -LEG FRAME SILLS 1" WEEP NOTCH AT EACH END EDGE DISTANCE �-1 + EMBED- MENT EDGE 1 r DISTANCE 1/4" MAX SHIM ---� ----J---I 'F" SEE TABLE / 3 NOTE B, FOR HEAD TYPE VERTICAL SECTION B-B TYP. ANCHOR TYPE, EMBEDMENTAND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 8. TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 8. USE EITHER 1 SWEEP LATCH @ MIDSPAN OR 2 BOTTOM LOCKS OPTIONAL HI -RISE SILL SHOWN. SEE SHEET 10 FOR STANDARD SILL. 1 /4" MAX. SHIM IAA INSTALLATION OPTION 2 ANCHOREDTHROUGH FRAME DIRECTLY INTO CONCRETE/CMU, EMBEDMENT 1/4" MAX SHIM 19 ° rFIXED VISIBLE LIGHT WIDTH e BUCK WIDTH INSTALLATION OPTION 3 ANCHORED THROUGH FRAME AND 1X BUCKSTRIP INTO CONCRETE/CMU. SEE NOTE 2, THIS SHEET. SASH VISIBLE LIGHT WIDTH HORIZONTAL SECTION AA ►— 1/4" MAX. SHIM DADE APPROVED MULLION, FBC COMPLIANT ALUMINUM/STEEL FRAMING OR STEEL STUD. MAY BE VERTICAL OR HORIZONTAL. SEE SUBSTRATE PROPERTIES, TABLE 8. INSTALLATION EQUAL OPTION 4 LEGlBOX ANCHORED THROUGH FRAME FRAME INTO METAL SHOWN Anchor Substrate Min. Edge Distance Min. Embedment P.T. Southern Pine (SG=0.55) 9/16" 1-3/8" #12 Steel, Aluminum, 6063-T5 min. 3/8" 0,063" 18-8 or 410 SS Screw A36 Steel 3/8" 0,063" Steel Stud, Gr. 33 min. 3/8" 0.045" (18 Ga) Concrete (min. 3.35 ksi) 1" 1,M3/4" teF SS CreteFlex Ungrouted CMU, (ASTM C-90) 2-1/2" 1-1/4" P.T. Southern Pine (SG=0.55) 1" 1-3/8" Concrete (min. 2.85 ksi) 1" 1-3/8" 1/4" Steel Uftracon Ungrouted CMU, (ASTM C-90) 2-1/2" 1-1/4" P.T. Southern Pine (SG=0.55) 1" 1-3/8" A) IN. OF 3 THREADS BEYOND THE METAL SUBSTRATE. B) USE ONLY FLATHEAD ANCHORS IN JAMBS. PAN/HEX/FLAT HEAD TYPE IS ALLOWABLE FOR ANCHORS IN THE HEAD. C) "UNGROUTED CMU" VALUES MAY BE USED FOR GROUTED CMU APPLICATIONS. 1/4" MAX SHIM 17 r-f� G� EMBEDMENT EDGE DISTANCE TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 8. VISIBLE LIGHT FORMULAS: (SHOWN FOR HI -RISE SILL; SEE SHEET 9 FOR STANDARD SILL) WIDTH @ SASH &FIXED LITE: BUCK WIDTH - 4.12" HEIGHT (EQUAL-LITE) BUCK HEIGHT/2 - 3,23" HEIGHT (PROVIEW) @FIXED LITE: BUCK HEIGHT/2 + 4.28" @SASH: BUCK HEIGHT/2 - 11.43" HEIGHT (CUSTOM SASH) @FIXED LITE: BUCK HEIGHT - SASH HEIGHT - 2.55" @SASH: SASH HEIGHT -4.60" NOTES: 1) USE ONLY SUBSTRATE -APPROPRIATE ANCHORS LISTED ON TABLE 8. FOLLOW EMBEDMENT AND EDGE DISTANCE LIMITS, ANY INSTALLATION OPTION SHOWN MAY BE USED ON ANY SIDE OF THE WINDOW. 2) MASONRY ANCHORS MAY BE USED INTO WOOD AS PER TABLE 8. ALL WOOD BUCKS LESS THAN 1-1/2" THICK ARE TO BE CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2" THICK OR GREATER. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. WOOD BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD. 3) VISIBLE LIGHT WIDTH OR HEIGHT (ALSO REFERRED TO AS DAYLIGHT OPENING) IS MEASURED FROM BEADING TO BEADING. O w O nab `fi O � ❑ O U) � LLJ > O c' a}o0 U` cal z � O O M LU cn z J O CL u W O _ O � J I� �8 U O of UMaJQ ON W J z = Q J J W ^ c7 Q 0M0 FFFFO a U) Z o Z CD z0 LL O M H O ® rn J U IN (� U) z I aa4S H U) X D O J z O W Q U CY U) Q W a�}il asa0 sauaS No. 58705 IiSO F k; F%%O ONAL III A. LYNN MILLER, P.E. P.E.# 58705 INSTALLATION DETAILS FOR INTEGRAL FIN FRAMES BUCK HEIGHT I EDGE EDGE DISTANCE DISTANCE EMBEDMENT 1 �- _ 1 0 a EDGE DISTANCE I 1/4" MAX SHIM 1/4" MAX SHIM ! EL � C�= 5 (� SASH VISIBLE 17 LIGHT WIDTH EMBEDMENT 19 � h 27EMBEDMENT L1/411mAx. FIXED VISIBLE —(2 1 SHIM LIGHT WIDTH n �: r 1� n IL a, f30 18 TYP, ANCHOR TYPE77 EMBEDMENT AND EDGE FIXED DISTANCE PER SUBSTRATE, 44 VISIBLE SEE TABLE 9. VI LIGHT HEIGHT 5B ( 31 5 OR 5 BUCK WIDTH — 11 14 43 63 SASH VISIBLE LIGHT HEIGHT EXTERIOR 42 1" WEEP NOTCH AT EACH END 32 13 USE EITHER 1 SWEEP LATCH @ MIDSPAN OR 2 BOTTOM LOCKS � STANDARD SILL SHOWN. SEE 33 PREVIOUS SHEET 8 FOR OPTIONAL HI -RISE SILL. 1/4 11 MAX SHIM If TYP. ANCHOR TYPE, EMBEDMENT AND EDGE EDGE DISTANCE DISTANCE PER SUBSTRATE, SEE TABLE 9. (SCREW SHOWN) --Otto]EMBEDMENT VERTICAL SECTION D-D HORIZONTAL SECTION C-C DADS APPROVED MULLION, FBC OMPLIANT ALUMINUM/STEEL FRAMING R STEEL STUD. MAY BE VERTICAL OR ORIZONTAL. SEE SUBSTRATE ROPERTIES, TABLE 9. #10 OR #12 STEEL SELF —DRILLING SMS (G5), SEE TABLE 9. INSTALLATION OPTION 7 ANCHORED THROUGH INTEGRAL FIN INTO METAL Anchor Substrate Min. Edge Min. Distance Embedment 2-1/2" x .113" Box Nail P.T. Southern Pine (SG=0.55) 5/16" 2,438 2-1/2" x .131" Common Nail P.T. Southern Pine (SG=0.55) 3/8" 2.438 2-1/2" x .145" Roofing Nail P.T. Southern Pine (SG=0.55) 318" 2,438 2-1/2" x .145" Roofing Nail P.T. Southern Pine (SG=0.55) 3/8" 2.438 P.T. Southern Pine (SG=0.55) 1/2" 1.375 #10 Steel Trusshead Screw or 12 Steel, 18-8 or 410 SS 0.125" Aluminum, 6063-T5 min. 5/16" 0.125 # Screw 0.050" A36 Steel 5/16" 0.05 0,045" (18 Ga) Steel Stud, Gr. 33 min. 5/16" 0.045 A) IN. OF 3 THREADS BEYOND THE METAL SUBSTRATE. TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 9. (NAIL SHOWN) VISIBLE LIGHT FORMULAS: (SHOWN FOR STANDARD SILL; SEE SHEETS 7 OR 8 FOR HI -RISE SILL) WIDTH @ SASH &FIXED LITE: BUCK WIDTH - 4.12" HEIGHT (EQUAL-LITE) BUCK HEIGHT/2 - 3.23" HEIGHT (PROVIEW) @FIXED LITE: BUCK HEIGHT/2 + 4.28" @SASH: BUCK HEIGHT/2 - 11.43" HEIGHT (CUSTOM SASH) @FIXED LITE: BUCK HEIGHT -SASH HEIGHT - 2.55" @SASH: SASH HEIGHT to 4.60" NOTES 1) USE ONLY SUBSTRATE -APPROPRIATE ANCHORS LISTED ON TABLE 9. FOLLOW EMBEDMENT AND EDGE DISTANCE LIMITS. ANY INSTALLATION OPTION SHOWN MAY BE USED ON ANY SIDE OF THE WINDOW. 2) VISIBLE LIGHT WIDTH OR HEIGHT (ALSO REFERRED TO AS DAYLIGHT OPENING) IS MEASURED FROM BEADING TO BEADING. A) IN. OF 3 THREADS BEYOND THE METAL SUBSTRATE. TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 9. (NAIL SHOWN) VISIBLE LIGHT FORMULAS: (SHOWN FOR STANDARD SILL; SEE SHEETS 7 OR 8 FOR HI -RISE SILL) WIDTH @ SASH &FIXED LITE: BUCK WIDTH - 4.12" HEIGHT (EQUAL-LITE) BUCK HEIGHT/2 - 3.23" HEIGHT (PROVIEW) @FIXED LITE: BUCK HEIGHT/2 + 4.28" @SASH: BUCK HEIGHT/2 - 11.43" HEIGHT (CUSTOM SASH) @FIXED LITE: BUCK HEIGHT -SASH HEIGHT - 2.55" @SASH: SASH HEIGHT to 4.60" NOTES 1) USE ONLY SUBSTRATE -APPROPRIATE ANCHORS LISTED ON TABLE 9. FOLLOW EMBEDMENT AND EDGE DISTANCE LIMITS. ANY INSTALLATION OPTION SHOWN MAY BE USED ON ANY SIDE OF THE WINDOW. 2) VISIBLE LIGHT WIDTH OR HEIGHT (ALSO REFERRED TO AS DAYLIGHT OPENING) IS MEASURED FROM BEADING TO BEADING. W z \ (>Y U) W O > O nab OO U) D LLJ O a}Dp (� N Z w Q O M � rn Oz Z _! O a. � O o toot U UMDJptoo W J ~ Z ¢ J <ON W .-. 9Mp Z O U_ Z 9t""' z O LL O co = C) a7 ® W 0 e7 U X Z z aays Q LL O Q 0O FootZ ly C7 r L'%ftwo U J Foot Q Z a1f asap sauasYN A. LYNN MILLER, P.E. P.E.# 58705 2.848" .062" 1.489" 062" FLANGE FRAME HEAD O O FLANGE FRAME SILL 1.300" OINTEGRAL FIN FRAME HEAD If-- 2.798" �I .466" ® 2.560" ® 2.060" (� 2.848" 062" f 062" .062"' 2„ 2.724" 2.724" 2.724" -� 1.125" �- .987" .062" O EQUAL LEG FRAME HEAD Imo-- 2.798" �-I OINTEGRAL FIN FRAME SILL �- 2.273" .120" 170" 2.150" 13 SASH TOP RAIL O EQUAL LEG FRAME SILL 2.772" 2.211" .062" .062" - 1.300" I ►- 14 FIXED MEETING RAIL 15 SASH BOTTOM RAIL - HI -RISE 341" 2.273" 2.105" 062 -Owl1.300" I� - FLANGE FRAME JAMB O O10 FLANGE FRAME SILL HI -RISE 1s SASH BOTTOM RAIL 1.300" 17 SASH SIDE RAIL 1.446" -"a- 1,522" lI.634" 465" .617" - -� I.496 1 .040" 627" .040" _ .802" 802" 802 802" .813" 73 1.370" .070" f 070" .045" -� f 050" f 18 HEAD ANCHOR 1s SASH STOP COVER 25a IG BEAD 2sa IG SNAP BEAD zs 5/16" LAMI BEAD 27 7/16" LAMI BEAD COVER 3„ OINTEGRAL FIN FRAME JAMB 11 INTEGRAL FIN FRAME SILL - HI -RISE STRUCTURAL POLYISOBUTYLENE WITH DESICCANT EXT. GLASS ILICONE 1 /4" NOM. V4�1 \-INT. GLASS 70 KODISPACE 4SG TPS ALUMINUM REINFORCEMENT BUTYL & DESICCANT FOAM EXT. GLASS-7 3„ O EQUAL LEG FRAME JAMB 2.798" G12 EQUAL LEG FRAME SILL HI -RISE STRUCTURAL SILICONE FOAM WITH DESICCANT EXT. GLASS 008" -MELT BUTYL 3/16" NOM. \-INT. GLASS 71 SUPER SPACER° NXT TM POLYISOBUTYLENE SEAL ROLL -FORMED STAINLESS STEEL GLASS 72 DURASEAL® SPACER EXT. GLASS DESICCANT FILL 5/16" NOM. SILICONE SEAL GLASS 73 XL EDGETM SPACER co Y W z T uS OLu >� nab O (n i Z) > O aioQ U' N z Lcr O 0 d � [n Z J O o U) W O LL _ O Z aO = = LLI o 2 f� g WU� �� uoa� ~ W Q J Q SMa 0 > Of F� O O o Z 0 Z C� Z LL O = O � 0 N rn J CD z aa4S U) Z 0 : O O � CD Z O � r� U 07 Q W a!}il �sa� sauaS L IN No.58705 =0�,°'. SAT F (� .#'CORIDP.•. //1lti10 A. LYNN MILLER, P.E. P.E.# 58705 TABLE 11: It#m PGT Part# Description Material 1 642001 Head, Flange Alum. 6063-T6 2 624017 Head, Integral Fin Alum. 6063-T6 3 624028 Head, Equal -leg Alum. 6063-T6 4 624004 Jamb, Flange Alum. 6063-T6 4A Jamb, Flange (Used For Alternate Radius Top Head) Alum, 6063-T52 5 624020 Jamb, Integral Fin Alum, 6063-T6 5A Jamb, Integral Fin (Used For Alternate Radius Top Head) Alum. 6063-T52 6 624031 Jamb, Equal -leg Alum. 6063-T6 6A Jamb, Equal -leg (Used For Alternate Radius Top Head) Alum. 6063-T52 7 624002 Sill, Flange Alum. 6063-T6 8 624018 Sill, Integral Fin Alum. 6063-T6 9 624029 Sill, Equal -leg Alum. 6063-T6 10 624003 Sill, Hi -Rise, Flange Alum. 6063-T6 11 624019 Sill, Hi -Rise, Integral Fin Alum, 6063-T6 12 624030 Sill, Hi -Rise, Equal -leg Alum. 6063-T6 13 624006 Sash Top Rail Alum. 6005A-T61 14 624005 Fixed Meeting Rail Alum. 6005A-T61 15 624012 Sash Bottom Rail - Hi -Rise Alum, 6063-T6 16 624068 Sash Bottom Rail Alum. 6063-T6 17 624007 Sash Side Rail Alum. 6063-T6 18 624051 Head Anchor Cover Alum. 6063-T6 19 624015 Sash Stop Alum, 6063-T6 25A 624009 IG Bead Alum. 6063-T5 25B 624011 IG Snap Bead Alum, 6063-T5 26 624013 5/16" Lami Beading Alum. 6063-T6 27 624026 7/16" Lami Beading Alum. 6063-T6 30 6TP247 Glazing Bead, Bulb Vinyl for #624023 Vinyl 31 6TP248 Glazing Bead, Bulb Vinyl for #624009 & #624011 Vinyl 32 724046 Sweep Latch (@ Top Rail) Cast Zinc 33 624049 Bottom Latch (@ Sill) Alum. 6063-T6 34 Setting Block (1/8" X 1/2" X 4") Neoprene 35A IG Setting Block (1/8" X 3/4" X 4") Neoprene 35B 724014 IG Snap Setting Block Vinyl 36 724044 Bottom Rail Weatherstrip Extension 37 724053 Sill Gasket Polyethylene 38 724054 Sash Top Rail Gasket Polyethylene 39 724055 Sash Bottom Rail Gasket Polyethylene 40 724057 Head Gasket Polyethylene 41 724063 Meeting Rail Gasket Polyethylene 42 61226D Sash Bottom Rail Bulb Vinyl Polyethylene 43 Weatherstrip, .270" x .187", Fin Seal (@ MR) 44 67S16G Weatherstrip, .170" X .270", Fin Seal (@ Sash Side Rail) 45 Weatherstrip, .170" X .187", Fin Seal (@ Top Sash Rail) 46 varies Balance with Cover & Trim Rigid Vinyl 51 781PSQX #8 X 1" PH SMS (Assembly) Stainless Steel 55 7834AA #8 X 3/4" Ph. PN SMS (Balance) Stainless Steel 63 - Alum. Screen with Fiberglass Mesh Varies 70 - Kommerling Kodispace 4SG TPS See Sheet 10 for 71 - Quanex Super Spacer nXT 72 - Quanex Duraseal Spacer Materials 73 - Cardinal XL Edge Spacer 74 - Dow 791, 899 or GE 7700 Backbedding Silicone J NOTES: 1) ALL CORNERS TO USE GASKET AND/OR SEALANT. 2) SOME PARTS/OPTIONS NOT SHOWN ON DRAWING FOR CLARITY. SAS H SIDE RAI L ASSEMBLY DETAILS FOR (OTHER FRAME TYPES SIMILARb SASH BOTTOM RAIL INTERIOR �11 TABLE 10: MATERIAL PROPERTIES USED FOR ANCHORAGE CALCULATIONS: Material Min. FyFu Steel Screw 92 ksi 120 ksi 18-8 Screw 60 ksi 95 ksi 410 Screw 90 ksi 110 ksi Elco UltraCon® 155 ksi 177 ksi 410 SS Elco CreteFlex® 127.4 ksi 189.7 ksi 6063-T5 Aluminum 16 ksi 22 ksi A36 Steel 36 ksi 58 ksi Gr. 33 Steel Stud 33 ksi 45 ksi 2a complying WRb i >. s n'aj�a€tg !e 3 Roe prMedSamn KUL . ial w Z U) U w O > O nab it o o cn �- Cl) CD Ld > O a}oQ U' N z Q O M N LL1 U7 O Z z OZ J O EL� .. W O O �_ = w N� j ti e U Umoa0 uUJ W ~ W ¢ J Q SMa ° Z z U r• U) Z U. O Q (0 = t— ® w N J 0 (D elf = Z }aays U) Z tY D o o z_ 0 06 U D _ �j O co Q 00 a�}�l osa� sauas LYIV� No.58705 SAT OF �\ tOM 5/ONAL III A. LYNN MILLER, P.E. P.E.# 58705