HomeMy WebLinkAboutProduct Review; Generac Auto Transfer SwitchesAutomatic FILE COPY Description GENERAC0 Service and non -Service rated Automatic Smart Transfer Switches 100 - 400 Amps, Single Phase C Ut, us LISTED &.LUCIE COUNTY PLAN REVIEW BLDG: DATE: ELE DATE 6 r0t PLUMB: DATE: MECH: DA O::�_ 'CUL only applies to non -service rated switches Geneac Automatic Transfer Switches are designed for use with single phase generators that utilize an Evolution'" or Nexus'" Controller. The 100, 200; and 400 amp open transition switches are available in single phase in both service equipment rated and non -service equipment rated configurations. The 150 and 300 amp open transition switches are only available in a service rated equipment configuration. Standard Features Service rated (RXSW) Generac Automatic Transfer Switches are housed in an aluminum NEMAIUL Type 3R enclosure*, with electrostatically applied and baked powder paint. The Heavy Duty General; Contactor is a UL recognized device, designed for years of service. The controller at the generator handles.all the timing, sensing, exercising functions, and transfer commands. All switches are covered by a 5 year limited warranty. Non -service rated (RXSC) switches are housed in a steel enclosure. DPM Technology Through the use of digital power technology (DPM), these switches have the capability to manage up to 4 individual HVAC (24 VAC controlled) loads with no additional hardware. When used in tandem with Smart Management Modules, up to 8 more loads can be managed as well, providing the most installation efficient power management options available. jISO 00, z000 GENERAC' 100-400 Amps, Single Phase Automatic Smart Transfer Switches Functions All timing and sensing functions odginatein the generator controller Utilityvoltage drop -cut .......................................................... ..................................................................................... ....................................................................... <65% Timer to generator start.................................................................................................. 10 second factory set; adjustable between 2-1500 seconds by a qual'1Bed dealer' Enginewarm up delay....................................................................................._..........................................................................................................................5 seconds Standbyvoltage sensor ......................... .......................... .......................................................... .......................................................................... ........... 65%for 5 seconds Utilityvoltage pickup .................. _..................................................................................................................................................................................... ................ >BD% Re-bansfer time delay................................................................................................................................................................... ........................................... .15 seconds Enginecool -down timer............................................................................................................................................................................................................ 60 seconds Exerciser............................................................................:.................................................................................5 or 12 minutes adjustable weekly/Ell-weekly/Monthly— The transferswitch can be operated manually without power applied. 'When used In conjunction with units utilizing Evolution- controls "Adjustable via the conholler Y Specifications Model RXSC100A3 RXSW100A3 RXSW15OA3 RXSC200A3 RXSW200A3 RXSW300A3 R)(SC40OA3 RXSW400A3 Amps 100 100 150 200 200 300 4W 400 Voltage 120240, 10 120240, to 120240,10 120240, to 120/240,1e 120/240,1e 120240, to 120/240, to Load Transition Type (Automatic) Open Transition Open Transition Service Rated Open Transition Service Rated Open Transition Open Transition Service Rated Open Transiition Service Rated Open Transition Open Transition Service Rated Enclosure Type NEMA/UL3R NEMNUL3R NEMWUL 3R NEMA/UL3R NEMA/UL3R' NEMA/UL3R NEMAAIL3R NEMA/UL 311 UL dating UUCUL UL UL ULICUL UL UL UUCUL UL Withstand Rating (Amps) 10,0GO 10.000 22,000 10,000 22,000 22,ODO 22,000 22.000 Lug Range 1/0-#14 250 MGM-#6 600 MGM -#4 or 1/0 - 250 MGM Dimensions Model RXS6700A3 Wffl00A3 WWISOA3 RXBC2WA3 RAW2= RXSW300/3 MMDOA3 WW400A3 Height H1 17.24/437.9 1724/437.9 26.751679.4 1724/4379 26.751679.4 42.9111089.S 31.25/793.9 2.91/10e99 (inlmm) H2 20/508 20/508 301762 207508 W62 4011219.2 361914.4 48/12192 WidthW1 12N3114 12.54117.5 10.5266.7 12.5/317.5 10.5/2669 16.69/42a.9 19.18/4872 16.69/423.9 QMmm) W2 14.6/370.8 14.6/d70.8 13.5/342.9 14.61370.8 13.53429 21415542 24/609.6 21.By5542 Depth (In/mm) 7.091180.1 7.09/180.1 6.3/160.1 7.09/160.1 62/160.1 10.06255.5 10.06/255.5 10.05/255.5 Wei9M (I8 x-) 20/9.07 22.5/1021 39/17.69 20/9.07 39/17.69 140/63.5 133/60.33 140/63.5 . oevm GENERAC• Generac Pourer Systems, Inc. • S45 W29290 HIM. 59, Waukesha, WI 53189 • generac.com ® ®2017Generec Power Gysmms,l2. NINhMmerve0. A➢spec0'xe6emmw*ct10dzVwr1wAr0lka BukOn I000ro1345&A 04/24/17