HomeMy WebLinkAboutLoad CalculationOptional Load Calculation
Heat Larger Than Air
IS SF x 3VA Living Only
(2) Small appliance ckts @ 1500VA each
Refrigerator @ 1500
Refrigerator @ 1500
Freezer @ 1500
Washing Machine @ 1500
Dishwasher @ 1500
Disposal @ 1S00
Mini Sewer @ 1500
Clothes Dryer @ 5000
Range @ 12000
Water heater @ 4500
Fixed microwave @ 1500
Vacuum @ LSOO
Trash Compactor @ 1500
Pool Heater @ 'name plate'
Spa @'name plate'
Motors 746VA per HP
Garage Door Opener
i) Total
2) First 10 KVA of general load @ 100%
3) Subtract line 2 from 1
4) Multiply line 3 @ 40%
s) Add lines 2 and 4
6) 60/50amp breakerfor heat (10000)
7) 40/30amp breaker for heat (5000)
8) Total heat -Add lines 6 and 7
9) Multiply line 8 @ 65%
10) Add lines 5 and 9
11) Divide line 10 by 240
Summary:
Line 10 is the total KW
Line 11 is the total Amps
75-60
3000
) s
- 16-00
- ISUO
- LS
1a! q6q
0
DEC 17 2019
S'F. Lucie County, Permitting
=fQ�SOD
— Q (Generator5ize Needed)
, 6 (Breaker size Needed)