Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Review; Generac Air-Cooled Gas Engine
16/20/22 kW INCLUDES: • True Power- Electrical Technology O Two Une LCD Multilingual Digital Evolution'" Controller (English/Spanish/ French/Portuguese) • Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. See Page 5 for Details. • Electronic Governor • Standard WT-Fi- Remote Monitoring • System Status & Maintenance Interval LED Indicators • Sound Attenuated Enclosure • Flexible Fuel Line Connector • Direct -To -Dirt Composite Mounting Pad • Natural Gas or LP Gas Operation • 5 Year Limited Warranty GENERACO GUAR®IANO SEMES Pke Residential Standby Generators Qop�,, Air -Cooled Gas Engine Standby Power Rating Models G007036-1, G007037-1 (Aluminum - Bisque) -16 kW 60 Hz Model G007035-1 (Aluminum -Bisque) -16 kW 60 F1z Models 6007039-1. G007038-1 (Aluminum - Bisque) - 20 kW 60 Hz ST.LUCIE COUNTViodels G007043-2, G007042-2 (Aluminum- Bisque) - 22 kW 60 Hz PLAN REVIEW BLDG: PLUMB: DATE: MECH: DATE: • Listed and Labeled by the Southwest Research Institute allowing installation as close as 18° (457 mm) to a structure.* *Must be located away from doors, windows, and fresh air intakes and /n accordance with local codes. https:/lassets.swrzorrggllibn ytDimctoryOlListedPmcfuctsf Conshuchonindushyl973 DoC 204 13204-01-01 Rey9.pol FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the head of Genamc's O success in providing the most reliable generators possible. Gamines's G-Force engine lineup offers added peace of mind and reliability for when you need it the most The G-Force series engines are purpose built and designed to handle the rigors of Wended run times In high temperatures and extreme operating conditions. O TRUE POWER" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O foal produce less than 5%Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed WAC systems. O TEST CRITERIA: V PHOTOTYPE TESTED V NEMA MGI-22 EVALUATION d SYSTEM TORSIONAL TESTED V MOTOR STARTING ABILITY OLISITED US QUIE-TlTESF � Note: CUL certification only applies to unbundled units and units packaged with limited circuit swilches. Unit packaged with the Smart Switch are UL certified in the USA only. SOLIDSTATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximbing regulation system Is standard on all Generac models. R provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage �egulatfon at x1%. SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire untL from the engine to the smallest electronic component O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line Includes its own transfer systems and controls for total system compatibility. O MOBILE LINK" REMOTE MONITORING: FREE with every Guardian Series Home _GENERAC _ standby generator. Allows you to monitor the status of your generatorfrom anywhere in the ;"'°. ""'� �� 5 O world using a smariphone, tablet, or PC. Easily access Information such as The current PROMISE �t �� ,� operating status and maintenance alerts. Connect your account to your authorized service dealer for fast, friendly and proactive service.Wdh Mobile Link, you are taken on of before the next power outage. e r I jj.,. D. 1'a_I . 16/20/22 W features and benefits Engine o Generac G-farce design Maximizes engine "breathing" for Increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine run cooler, reducing oil consumption resulting in longer engine life. "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition4park advance These features combine to assure smooth, quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. 9 Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulates the output voltage to ±1%prevents damaging voltage spikes. • UL2200listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers your vital electrical loads to the energized source of power. • NEMA 3R Can be Installed Inside or outside for maximum flexibility. • Remote mounting Mounts near your existing distribution panel for simple, low-cost installation. Evolution" Controls • Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication in any condition. • Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. • Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage, selpoints 65% dropout, 80% pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of five (5) seconds by a qualified dealer • Engine warm-up Ensures engine Is ready to assume the load, setpolnt approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute: • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift -out frontfor easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18° (457 mm) away from a building. 16/20/22 kW Installation•. System CJL+SIY V1ERAC" features and benefits ® 1 ft (805 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. ® Direct -to -did composite mounting pad Complex lattice design prevents settling or sinking of the generator system. m Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life. Remote Mlanitoring 6 Ability to view generator status ® Ability to view generator Exercise/Run and Total Hours IF Ability to view generator maintenance Information ® Monthly report with previous month's activity. 0 Ability to view generator battery Information ® Weather information Monitor your generator via your smariphone, tablet, or computer at any time via the Mobile Llnk application for complete peace of mind Review the generator's complete protection profile for exercise hours and total hours Provides maintenance Information for your specific model generator when scheduled maintenance Is due Detailed monthly reports provide historical generator information Built in battery diagnostics displaying current state of the battery Provides detailed local ambient weather conditions for generator location 16/20/22 W specifications Generator Model G007035-1, G007036-1, G007038-1, G007039.1 G007042.2, G007043.2 60070371 (16 kW) (20 kVb (22 hq -Hated MaxlmOm Continuous Power Dairen! (N) - .' 16000 Wa1t5'' _ 20;000:Wa115' 22,000Watte , Rated Maximum Cont'nuous Power CapedN(NG) 1.6,000Walts' 18,000Watls' --_. 19,500 Wells' Pa.IeU.Vat lage -; _..<...-. ', - `240' .. .240: . y_: Baled Maximum Continuous Load Cumrurd-240 Volts(LPING) 66.7166.7 83.3175.0 91.7/01.3 _ 7uIZI Harmo91p.01s(orllpn _ _ - - __ Less than 5%-,. - „ Less than 596•-' . Lessfhin 5% - Main Line Circuit Breaker 70 Amp 90 Amp 1o0 Amp Number of Rotor Poles .__.—._.__ .Hated A fyequency, 2 2 2 Power Factor - - 1.0 1.0 1.0 -"'^" Bari llequirement (hot included)..' ' : _ 12.9alis Glob rate - p P540 CCA MImm9m ukGrd 35AGM 650 CCA Minimum - up Unit Weight(IbAg) 409/186 4481203 466/211 Oimeps)ons (LxWa 93 x25 x 29 /121Bz038x732 Sound output In dB(A)at 23it(7m)With generator operating at normal load" 67 67 - 67 $oundoutolfijnd8(Al 912'd0pippwith'generalpriRgOiet:Tesl low-speeAenter cise_mgde - • -, -,55-, 55'"-' 57 Type of Engine GENERAC G-Fored1000 Series <Jpy moat ofCYlMdert;. .".2 2'_i`'' 2 Displacement 999 cc 999 cc 999 cc - a ...; •: A_lumIrumw/Casl'Gon Sleeve a Valve Arrangement Overhead Valve Overhead Valve Overhead Valve ;FnInitlooby»�lem' -5 - _ Sol(d=iet'eewf Magheto' Soli_d-stalew%Mayneio Solid-slafe W/Magneto Gossamer System Electronic Electronic Electronic CtimPressfon R`atlo.•, ._ J.s9.51r •' 95?�"���:9.5:1.. - _ Starter 12VDC 12 VDC• 12 VOC Oil�CepamNlnclddid9Flidr:;_. , + Approxr:19g1/1.B.L: •- APProx l.9 ql/LB C Apprwf._19111/1.8L _ 0peratng rpm 3,600 3,600 3,600 Epel.Codsumpltod ' INa[ural Gas GaPor (ma/gr) 12 Load; ,. 218 (617) -. > 204 (578) 228 (6,46) (4 Full Load; a ' .'c'•r y(815) 301 (B_52) ,' 327(926) Lttjuid Propane ft3Por(gaVhr)[Ipble; v • 12 Load. '. , s cn 74(203)1770] 87(237)[8.99): - 92(2.53)[9.57) - 142 (3:90) [14.771 Nola: fuel pipe must he sized for fullidad. Requited fuelppressure to AengratorNel inlet at all lead ranges 3.5-7'vater column(7-13 rem mercury) for natural ges,l0-12'wdler wlumn(19-22 mm mercury) for IP gas For BTU content multiply ft M x 2500 (LP) or 1NMx 1000 (NG). ForMegaloule content, muitipryma/arx 93.15 (LP) or III 37.26 INS) Controls - - - Two -Line Plain Text Multilingual LCD Display Simple user Interface for ease of operation. M de Butlons406 7 - - AulomaliE51ar1 on 011lllyle7Nre ]day eurdsei Manual Start with starter corral, unit stays on. if u68N fags transfer to load takes place. ., _• Cry:._', ` : ,. - Siopsunli: Pmver7s rcmoVeB. ..,.,- .._ .. _ . Conbalana eharperstill operate. _ Ready to NuNMainamance Messages Standard f gii epuorj Progmmmabie start tlatay between 2 1500 seconds Standard (programmable by dealer only) @kmi :VoltaHa LosslNeN)Ato UBlll-—&-hble(Afownout S-a erg), -' . `F0040171 VIl90=21fi V' Future Set Capable Eiereiser/Fxercise Set Error Wanting Shndar�d IitiNAla"mVMaintenadcelogs Engtneslarlsequence craclong: 16 sec on 7 real(9D see maximum duration). iia!le"Il_'dck-au ' _Cyclic - slad`eitanool ie-engage u9_tll5 sec'after engine bas slopped. amad Battery Charger Sandard dargerFav-�It/MlssI kAC?Nammg SlandaN;_ .ow Badery/Battery Problem Protection and Battery Condltlon Ictlicatfon Standard )u(hm'EIE VolI-"--"abider-' Over and Urider Vulh`ge PrdlecIIcY --- Inder-Frequency/Overload/Stepper Overcument Pmtection Standard IaYety Fusetl/FUSeFiohlem Prateillan _ _ - _ _ 'Slanda`id' mtomatic Low Oil Prassure%High till Temperature Shutdown Standard we(p�an'1 INv end( _72,fi ryMsense Cuss shuttlovm. .. ,. .. ,. .. .... _ _ .. .:'.. . - SWnd$rd=', .... .. .. ligh Engine Temperature Shutdown Standard tlema(FaulNnCoReafWinnA Proieitign ` a".._"`W .:.. .. - . • : ' - - staddu0 `' �ommon External fault CapabilityStandard Feld tadaie Eitmiv"dte`` - -. -. .. ._ _.Pg,�.�.,_,.... - .- _ .. -__ --Stanch@ - - ."__ . "Sound tattle are taken term mehoNads gere ater.Soundkteistakenfromelversidesofthegeneratornaybehigherdependingonfnstalegonpaameters.Rtirgdefmitiau-StandbyAppfira6leforsupplprgenerieocypmrerfortheduration It the u60ypgneruNage. No overload capablRy is trainable fortltis sling. (All stings In accordance wim BS5514, 603046 and 0n6271). 7 Mranum laws amps and gmeN anesubject to and Herbert bysudl laMa as fuel Bhpmega)rule content ambkntlampeMua,altitude, engine powerand condition. ele. Madmum grainer deaeasesabOutUnsnarl for each 1,000 feel(304.B melors) abmesea lev bandalso willdecreaseaboull percent lmeach 6.0(In above 16-C(60°H. GENE ACO 16/20/22 kW snitch options Limited Circuits 81,vitch Features • 16 space, 24 circuit, breakers not Included. • Electrically operated, mechanically -held contacts for fast, positive connections 9 Rated for all classes of load,100% equipment rated, both Inductive and resistive. 0 2-pole, 250 VAC contactors. • 30 millisecond transfer time. • Dual call design. • Rated for both copper and aluminum conductors. © Main contacts are silver plated or silver alloy to resist welding and sticking. 0 NEMA/UL 311 aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • Multi listed for use with 1'standard, tandem, GFCI and AFCI breakers from Siemens, Murray, Eaton and Square D for the most flexible and cost effective install. Dimensions Height width Depth H1 H2 wt W2 in 26.75 3D.1 10.5 13.5 6.91 mm 679A 764.3 1 266.7 343.D 175A Wire Ranges Conductor Lug Neutral Lug Ground Wg 1/0-#14 2A-414 210-#14 Service Rated Smart Switch Features • Includes Digital Power Management Technology standard (DPM). • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to four more large (240 VAC) loads can be managed when used in conjunction with Small Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of load, 100%equipment rated, both inductive and resis- tive. • 2-pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 311 aluminum outdoor enclosure allows for Indoor or outdoor mount- ing flexibility. Dimensions 200 Amps 120/240, 10 Open Transition Service Rated Height Width Depth HI H2 Wl W2 1 in 26.75 30.1 10.5 13.5 6.91 ram 679.4 764.3 1 266.7 343.0 175A Model G007036.1 (16kW) current Rating(Amps) 100 ':.12b oJil .. . . Utlllty Voltage Monitor (Fixed)' -Pick-up 60% -Dropout 65% sec. .. -. Exercises 5 minutes* Standard _bl-weeklyfor Total Circuits Available 24 Ta+n�em, B`re59eT6Apa611iliesi - _ alandems Chun Breater Protected Available RMS symmetrical 10,000 Fault current Q 250 Volts *Function of Evolution Controller Exercise can be set to weekly or monthly 1 (. '^ wrJ �DEpDI µ W[ Model 13007037.1 (16kM/G007039.1 (20kM/ 0007043.2 (22 kl'l7 6W°f ... ...:_,_ current Bating (Amps) 200 .VNNOKAgp!AC);�`?�; u,-'f �t:':•-..�:`•.i .12g240�19 utility Voltage Monitor (Feed)' .. -Pick-up ee% -Diropour 65% ;Bety;;:'_approL135ec! Exercises bl-weektyfor5 minutes' standard fUL Lisled'_'���..'.'=�:•'".ts�... _ `.'<:'�. _=; Standard,. .' . Enclosure Type NEMAM311 Cttcud pryakefPiolecled _ ' 22doo Lug Range 250 MCM -#6 *Function of Evolution Controller Exercise can be set to weekly or monthly 9 6/20/22 kW Model # Prdducl ` Uescnpl)an The WI-FI enabled LP fuel level mordtorprovides constant monitoring of the connected LP fuel tank. Mon- the LP tanks fuel level is an important step In making sum your generator is ready to ran during an G007005-0,W-F LP Fuel Level Monitor unexpected powerfailure. Status alerts are available through afree application to notify when your LP tank is in need of a refill. Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet IG005819-0, 26R Wet Cell Battery cell battery for use with all air-cooled standby product (excluding PowerPaGt®). 'Battery The pad warmer rests under the battery. Recommended for use if the temperature regularly falls below 'G007101-0• Pad Warmer 0 IF (-18 °C). (Not necessary for use with AGM -style batteries). ',Oil warmer slips directly overtheoil filter.Recommended for use tithe temperatureregularly falls below 0°F G007102-0 'Oil Wanner (-18 °C). -The breather warmer is for use in extreme cold weather applications. For use with Evolution controllers •G007103-1 Breather Wanner only in climates where heavy icing occurs. (Auxiliary Transfer Switch 1TheauxlllaryWaterswitchcontactkitallowsthetransferswitchtolocko6tasinglelargeelectricalload! G005621.01 ;Contact KB +;you may not need. Not compatible with 50 amp pre -wired switches. 'The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a Fascia Base Wrap IGt j G007027-0 - Bisque Fasciaallon Wrap 'sleek, contoured appearance as well as offering protection from rodents and Insects by covering the lifting (Standi 2 WO holes located in the base. I !If the generator enclosure Is scratched or damaged, it Is Importard to touch up the palatto protect from �G005703-0.-Bisque 'PaintR future corrosion. The paint kit Includes the necessary paint to property maihtaln or touch up a generator enclosure. ; G006485-0: :Scheduled Maintenance Kt, Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine I maintenance on a Generac automatic standby generator. 1 Smart Management Module �Smart Management Modules are used Inconjunction with the AuromagcTransfer Switch toIncrease its G006873-0; , power management capabilities. It provides additional power managementflexibilfty not found in any other 1(50 Amps) ! power management system. ,. dimensions & PCs Dimensions shmm areapprudmate. RefeelolnstalWaa DO NO USE THESE DWENSIDNS FOR INSTAL APoNPURPDSES. LEF'r SIDEV1EW MDWVIEW Model UPC G007035-1 696471074161 G007036-1 696471074154 G007037-1 696471074178 G007038-1 696471074185 G007039-1 696471074192 G007042-2 696471074208 G007043-2 696411174215 GE1 V EIS ACO Generac Power Systems, Inc. I S45 W29290 HWY.59, Waukesha, WI 53189 • generac.gom • . 02018 Generac Power Sysiems,MD. AD 99hB reseNed.A0 specrficanons are subject to change wMoutnmlce. Pad No. 10000000194-H (8101/16) -