HomeMy WebLinkAboutProduct Review; Generac Smart Management Modules (SMM)Smart Management Modules (SMM) FEATURES r GENERAC® ACCESSORIES Model G007000-0 UPC 696471070002 C WIL US LISTED Generac's Smart Power Management System is designed to optimize the performance of a standby generator. The system can consist of up to 8 individual Smart Management Modules (SMM). Unlike other load management systems that depend on another control device, the SMM modules are actually self -aware and operate autonomously. Frequency is the true measure of generator engine performance and does not need to factor in increased ambient temperatures; elevation changes or generator fuel type. The modules monitor the frequency (Hz) of the power being produced by Generac's standby generators. If frequency falls below a certain threshold, the module will automatically fallow a power management algorithm to reduce the chance of a generator overload condition. The modules can be set to a load priority between 1-8, or be set in a lock -out only mode for loads that just simply do not need to run In an outage. This reduces the minimum size of the generator for a more cost-effective solution. SMM SPECIFICATIONS PowerSupply Source............................................................................................................................................................. •.............240 VAC (from Line Input) ContactVoltages..................................................................................................................................................................................................... 220/240 VAC ContactorCoil Voltage................................................................................................................................................................................................... 240 VAC CoilVA Inrush..........................................................................................................................................................................................................................30 CoilVA Sealed........................................................................................................................................................................................................................6.5 ResistiveAmps........................................................................................................................................................................................................................50 F/L Inductive Amps..................................................................................................................................................................................................................40 LockedRotor Amps................................................................................................................................................................................................................180 Enclosure Rating .......... Frequency Selectability GENERAC® ............UL 50 50 Hz / 60 Hz ""'ENERAC" Smart Management Modules (SMM) ®imehsions and UPC Model G007000-0 Height(iNmm) H1 6.17/156.8 112 2.36160 Width(io/mm) Wt 7.06/179.4 W2 4.72/120 Depth(III/mm) 3.7/94 Weight(IbAif) 2.06/0.94 Shipping Weight(lb/kg) 2.44/1.11 UPC Code 696471010002 SMM Controls (located behind the module cover) LID ON=LOAD CONNECTED LED FLASH 1S =LOAO SHED PRIORITY LOCKOUTLOADON LED FLASH 3S c 30 MIN LOCKOUT \ GENERATOR LED FLASH BS _ GFN LOAD LOCKOUT 7 LED OFF= NO MOOUIFPOWEII O ® • 0--] D LOCKOUT TEST DISABLED Priority D121(A) Sets module pdority Lockout Switch (0) Prevents load from Operating when system Is operating under generator power. Test Buffon(C) Disables cordactoroulputfor a specified time. LED(D) Provides module statute wMeasy viewing through the Wemalviewing window located in the upper right comer of the module. G E N G 1'f/Yi CO Genemc Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 - genemc.com @2018 Generao Powu Systems,Inc. All rights reserved. AH specifications are subject to change WIWI notice. Pad No. IDODD029407 rev B (1i/14118)