Loading...
HomeMy WebLinkAboutWind Design Pressure Chart Exposure D Building height Zone 4 Area 15 20 25 30 35 40 45 50 55 60 10 pos 46 48.5 50.4 52 53.2 54.5 55.7 56.7 57.6 58.6 neg 49.9 52.6 54.7 56.4 57.7 59.1 60.4 61.5 62.5 63.5 20 pos 44.1 46.5 48.3 49.8 51 52.2 53.4 54.3 55.2 56.1 neg 47.9 50.5 52.5 54.1 55.4 I 56.7 58 59 60 60.9 50 pcs 43 45.3 47 48.5 49.7 50.8 52 52.9 53.8 54.6 neg 45.1 47.5 49.4 50.9 52.1 53.3 54.6 55.5 56.4 57.3 100 pos 39.2 41.3 42.9 44.2 45.3 46.4 47.4 48.2 49 49.8 neg 43 45.4 47.1 48.6 49.8 50.9 52.1 53 53.9 54.8 500 pos 34.3 36.2 37.6 38.7 39.7 40.6 41.5 42.2 42.9 43.6 neg 38.2 40.3 41.8 43.1 44.2 45.2 46.2 47 47.8 48.6 Building height End zone 5 15 20 25 30 35 40 45 50 55 60 10 pos. 46 48.5 50.4 52 53.2 54.5 55.7 56.7 57.6 58.6 neg 61.7 65 67.5 69.6 71.3 73 74.7 75.9 77.2 I 78.4 20 pos 44.1 46.5 48.3 49.8 51 52.2 53.4 54.3 55.2 56.1 neg 57.5 60.6 63 64.9 66.5 68.1 69.6 70.8 72 73.2 50 pos 43 45.3 47 48.5 49.7 50.8 52 52.9 53.8 54.6 neg 51.9 54.8 56.9 58.7 60.1 61.5 62.9 64 65 66 100 pos 39.2 41.3 42.9 44.2 45.3 46.4 47.4 48.2 49 49.8 neg 47.9 50.5 52.5 54.1 55.4 56.7 58 59 59.9 60.9 500 pos 34.3 36.2 37.6 38.7 39.7 40.6 41.5 42.2 42.9 43.6 neg 38.2 40.3 41.8 43.1 44.2 45.2 46.2 47 47.8 48.6 Wind design Pressure Chart for structures subject to Florida Residential Code 170 mph exposure D Wall component and Cladding pressures from Table R302.2(2) modified by adjustment factors from R301.1(3). Converted to Vasd according to R302.1.2.1.1 MILLER7224 MYSTIC WAY PSL,FL