HomeMy WebLinkAboutENCODEEnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 64/23/2020 4:49 PM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
PACE 2000, INC.
GARRY WILLIAMS
WILLIAMS RESIDENCE
Street:
City, State, Zip: FORT PIERCE , FL , Permit Number:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
New (From Plans)
Single-family
1
No
1999
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
d. U-Factor:
S H G C :
Sgl, U=0.58 210.00 ft²
SHGC=0.23
Sgl, U=0.56 126.00 ft²
SHGC=0.23
Sgl, U=0.65 96.00 ft²
SHGC=0.21
other (see details)93.33 ft²
other (see details)
8. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 1999.00 ft²
R=f t ²
R=f t ²
9. Wall Types
a. Concrete Block - Ext Insul, Exterior R=4.1 1762.70 ft²
b. Frame - Wood, Adjacent R=11.0 340.00 ft²
c. N/A R=f t ²
10. Ceiling Types
a. Roof Deck (Unvented)R=20.0 1999.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
12. Cooling systems
13. Heating systems
14. Hot water systems
a. Electric Cap: 1 gallons
b. Conservation features
None
d. N/A R=f t ²
Area Weighted Average Overhang Depth:5.624 ft.
Area Weighted Average SHGC:0.235
Description Area
Insulation Area
Insulation Area
Insulation Area
15. Credits None
3
(525.3 sqft.)
(2102.7 sqft.)
(1999.0 sqft.)
(1999.0 sqft.)
Conditioned floor area below grade (ft²) 0
a. Central Unit
a. Electric Strip Heat
k B t u / h r
35.2 SEER:16.00
Efficiency
k B t u / h r Efficiency
27.0 COP:1.00
f t ² R
6 150
Tankless
EF: 0.980
Glass/Floor Area: 0.263
Total Proposed Modified Loads:
Total Baseline Loads:
69.21
71.46 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2017
4-24-2020
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
PACE 2000, INC.
1
GARRY WILLIAMS
WILLIAMS RESIDENCE
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle:0
No
1
1999
3
New (From Plans)
Single-family
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL ,
FORT PIERCE ,
St. Lucie
Street Address
Comment:
Building Type: User
Cross Ventilation:No
Whole House Fan:No
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 7529962 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 Entire House 1999 20225.2
Number NameAreaVolume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1M TOILET30300 No 0 Yes Yes1Yes
2 M BATH 110 1100 No 0 Yes Yes1Yes
3M WIC 70 700 No 0 Yes Yes1Yes
4 MASTER BEDROO 295 2950 No 01 Yes Yes1Yes
5 FOYER 105 1050 No 0 Yes Yes1Yes
6 LIVING ROOM 336 3595.2 No 0 Yes Yes1Yes
7 NOOK 221 2210 No 0 Yes Yes1Yes
8 KITCHEN1821820 Yes 0 Yes Yes1Yes
9 BATH 2 104 1040 No 0 Yes Yes1Yes
10 HALL 68 680 No 0 Yes Yes1No
11 LINEN 18 180 No 0 Yes Yes1No
12 CLST 2 18 180 No 0 Yes Yes1No
13 BEDROOM 2 185 1850 No 01 Yes Yes1Yes
14 BEDROOM 3 185 1850 No 01 Yes Yes1Yes
15 CLST 3 18 180 No 0 Yes Yes1Yes
16 LAUNDRY54540 No 0 Yes Yes1Yes
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
1 30 ft² 100______ Slab-On-Grade Edge Insulation - - - -011 ft M TOILET
2 110 ft² 100______ Slab-On-Grade Edge Insulation - - - -013 ft M BATH
4/23/2020 4:49 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
3 70 ft² 100______ Slab-On-Grade Edge Insulation - - - -07 ft M WIC
4 295 ft² 100______ Slab-On-Grade Edge Insulation - - - -033 ft MASTER BEDRO
5 105 ft² 100______ Slab-On-Grade Edge Insulation - - - -07 ft FOYER
6 336 ft² 100______ Slab-On-Grade Edge Insulation - - - -019 ft LIVING ROOM
7 221 ft² 100______ Slab-On-Grade Edge Insulation - - - -013 ft NOOK
8 182 ft² 100______ Slab-On-Grade Edge Insulation - - - -014 ft KITCHEN
9 104 ft² 100______ Slab-On-Grade Edge Insulation - - - -08 ft BATH 2
10 68 ft² 100______ Slab-On-Grade Edge Insulation - - - -01 ft HALL
11 18 ft² 100______ Slab-On-Grade Edge Insulation - - - -01 ft LINEN
12 18 ft² 100______ Slab-On-Grade Edge Insulation - - - -01 ft CLST 2
13 185 ft² 100______ Slab-On-Grade Edge Insulation - - - -016 ft BEDROOM 2
14 185 ft² 100______ Slab-On-Grade Edge Insulation - - - -026 ft BEDROOM 3
15 18 ft² 100______ Slab-On-Grade Edge Insulation - - - -02 ft CLST 3
16 54 ft² 100______ Slab-On-Grade Edge Insulation - - - -06 ft LAUNDRY
#Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1 Flat Concrete 2001 ft² Medium 0.2 20 2.4______No42 ft² 0.9 NoN
ATTIC
#Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 No attic Unvented 1999 ft² N N0
4/23/2020 4:49 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
#Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Unvented)0 30 ft² 0.1 Wood______M TOILET Blown
2 Under Attic (Unvented)0 110 ft² 0.1 Wood______M BATH Blown
3 Under Attic (Unvented)0 70 ft² 0.1 Wood______M WIC Blown
4 Under Attic (Unvented)0 295 ft² 0.1 Wood______MASTER BEDRO Blown
5 Under Attic (Unvented)0 105 ft² 0.1 Wood______FOYER Blown
6 Under Attic (Unvented)0 336 ft² 0.1 Wood______LIVING ROOM Blown
7 Under Attic (Unvented)0 221 ft² 0.1 Wood______NOOK Blown
8 Under Attic (Unvented)0 182 ft² 0.1 Wood______KITCHEN Blown
9 Under Attic (Unvented)0 104 ft² 0.1 Wood______BATH 2 Blown
10 Under Attic (Unvented)0 68 ft² 0.1 Wood______HALL Blown
11 Under Attic (Unvented)0 18 ft² 0.1 Wood______LINEN Blown
12 Under Attic (Unvented)0 18 ft² 0.1 Wood______CLST 2 Blown
13 Under Attic (Unvented)0 185 ft² 0.1 Wood______BEDROOM 2 Blown
14 Under Attic (Unvented)0 185 ft² 0.1 Wood______BEDROOM 3 Blown
15 Under Attic (Unvented)0 18 ft² 0.1 Wood______CLST 3 Blown
16 Under Attic (Unvented)0 54 ft² 0.1 Wood______LAUNDRY Blown
WALLS
#Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
1 4.1 0M TOILET 000 6 1 0NConcrete Block - Ext Insul 0.20Exterior60.0 ft² ____
2 4.1 0M TOILET 000 5 1 0WConcrete Block - Ext Insul 0.20Exterior50.0 ft² ____
3 4.1 0M BATH 000 8 1 0NConcrete Block - Ext Insul 0.20Exterior80.0 ft² ____
4 4.1 0M BATH 000 5 1 0WConcrete Block - Ext Insul 0.20Exterior50.0 ft² ____
5 4.1 0M WIC 000 7 1 0WConcrete Block - Ext Insul 0.20Exterior70.0 ft² ____
6 4.1 0MASTER BE 000 1 8 1 0SConcrete Block - Ext Insul 0.20Exterior180.0 ft² ____
7 4.1 0MASTER BE 000 1 5 1 0WConcrete Block - Ext Insul 0.20Exterior150.0 ft² ____
8 4.1 0FOYER000 7 1 0SConcrete Block - Ext Insul 0.20Exterior70.0 ft² ____
9 4.1 0LIVING ROO 080 1 9 1 0SConcrete Block - Ext Insul 0.20Exterior202.7 ft² ____
10 4.1 0NOOK000 1 3 1 0NConcrete Block - Ext Insul 0.20Exterior130.0 ft² ____
11 4.1 0KITCHEN000 1 4 1 0NConcrete Block - Ext Insul 0.20Exterior140.0 ft² ____
12 4.1 0BATH 2 000 8 1 0NConcrete Block - Ext Insul 0.20Exterior80.0 ft² ____
13 11 0BATH 2 000 1 3 1 0E Frame - Wood 0.20.1Garage130.0 ft² ____
14 11 0HALL000 1 2 1 0N Frame - Wood 0.20.1Garage120.0 ft² ____
15 4.1 0BEDROOM 2 000 1 3 1 0SConcrete Block - Ext Insul 0.20Exterior130.0 ft² ____
16 4.1 0BEDROOM 2 000 3 1 0WConcrete Block - Ext Insul 0.20Exterior30.0 ft² ____
17 4.1 0BEDROOM 3 000 1 3 1 0EConcrete Block - Ext Insul 0.20Exterior130.0 ft² ____
18 4.1 0BEDROOM 3 000 1 3 1 0SConcrete Block - Ext Insul 0.20Exterior130.0 ft² ____
19 4.1 0CLST 3 000 2 1 0EConcrete Block - Ext Insul 0.20Exterior20.0 ft² ____
20 4.1 0LAUNDRY000 6 1 0EConcrete Block - Ext Insul 0.20Exterior60.0 ft² ____
21 11 0LAUNDRY000 9 1 0N Frame - Wood 0.20.1Garage90.0 ft² ____
4/23/2020 4:49 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1N Low-E Single 0.56 0.23 8.0 ft² 8 ft 0 in 0 ft 0 in NoneVinyl None______Yes1 N
2N Low-E Single 0.56 0.23 8.0 ft² 8 ft 0 in 0 ft 0 in NoneVinyl None______Yes3 N
3S Low-E Single 0.58 0.23 90.0 ft² 8 ft 0 in 0 ft 0 in NoneVinyl None______Yes6 N
4W Low-E Single 0.56 0.23 12.0 ft² 0 ft 0 in 0 ft 0 in NoneVinyl None______Yes7 N
5S Low-E Single 0.3 0.28 48.0 ft² 8 ft 0 in 0 ft 0 in NoneVinyl None______Yes8 N
6S Low-E Single 0.56 0.23 90.0 ft² 8 ft 0 in 0 ft 0 in NoneVinyl None______Yes9 N
7N Low-E Single 0.65 0.21 96.0 ft² 8 ft 0 in 0 ft 0 in NoneVinyl None______Yes10 N
8N Low-E Single 0.56 0.23 8.0 ft² 8 ft 0 in 0 ft 0 in NoneVinyl None______Yes11 N
9N Low-E Single 0.3 0.28 21.3 ft² 8 ft 0 in 0 ft 0 in NoneVinyl None______Yes12 N
10 S Low-E Single 0.58 0.23 60.0 ft² 0 ft 0 in 0 ft 0 in NoneVinyl None______Yes15 N
11 S Low-E Single 0.58 0.23 60.0 ft² 0 ft 0 in 0 ft 0 in NoneVinyl None______Yes18 N
12 E Low-E Single 0.3 0.28 24.0 ft² 0 ft 0 in 0 ft 0 in NoneVinyl None______Yes20 N
# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
GARAGE
1 441 ft² 441 ft² 34 ft 10 ft 11______
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
2359.6 7129.54.00045Wholehouse .1713243.62Proposed ACH(50)1
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtypeBlockSpeed
1 Electric Strip Heat/COP:1 27 kBtu/hr ______sys#1None1
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtypeBlockSubtype
1 Central Unit/SEER: 16 35.2 kBtu/hr 1056 cfm 0.8______sys#1Split1 Single
# System Type EF Cap Use SetPnt Conservation
HOT WATER SYSTEM
SubType Location
1 Electric 0.98 1 gal 60.9 gal 120 deg None______Tankless LAUNDRY
FSEC
Company Name System Model #Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert #Area Volume
None None f t ² ______
4/23/2020 4:49 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Location R-Value Area Location Area
---- Supply -------- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6 150 ft² Attic 15 ft² Default Leakage Attic (Default) c______1 1 (Default) c
TEMPERATURES
Programable Thermostat: N Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec
[X] Dec[X] Nov
[X] Nov
[ ] Oct
[X] Oct
[ ] Sep
[ ] Sep
[ ] Aug
[ ] Aug
[ ] Jul
[ ] Jul[ ] Jun
[ ] Jun
[X] Jun
[ ] May
[ ] May
[ ] Apr
[X] Apr
[X] Mar
[X] Mar
[X] Feb
[ ] Feb
[X] Jan
[ ] Jan
Heating
Venting
Thermostat Schedule:HERS 2006 Reference Hours
Schedule Type 12345678910 11 12
Cooling (WD)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Cooling (WEH)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Heating (WD)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type Area T hickness Furniture Fraction Space
Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 M TOILET
Default(8 lbs/sq.ft.f t ² f t 0.3 M BATH
Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC
Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BEDROO
Default(8 lbs/sq.ft.f t ² f t 0.3 FOYER
Default(8 lbs/sq.ft.f t ² f t 0.3 LIVING ROOM
Default(8 lbs/sq.ft.f t ² f t 0.3 NOOK
Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN
Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 2
Default(8 lbs/sq.ft.f t ² f t 0.3 HALL
Default(8 lbs/sq.ft.f t ² f t 0.3 LINEN
Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 2
Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 2
Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 3
Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 3
Default(8 lbs/sq.ft.f t ² f t 0.3 LAUNDRY
4/23/2020 4:49 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT