Loading...
HomeMy WebLinkAboutENCODE (2)EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 64/23/2020 4:49 PM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY PACE 2000, INC. GARRY WILLIAMS WILLIAMS RESIDENCE Street: City, State, Zip: FORT PIERCE , FL , Permit Number: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) New (From Plans) Single-family 1 No 1999 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Sgl, U=0.58 210.00 ft² SHGC=0.23 Sgl, U=0.56 126.00 ft² SHGC=0.23 Sgl, U=0.65 96.00 ft² SHGC=0.21 other (see details)93.33 ft² other (see details) 8. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 1999.00 ft² R=f t ² R=f t ² 9. Wall Types a. Concrete Block - Ext Insul, Exterior R=4.1 1762.70 ft² b. Frame - Wood, Adjacent R=11.0 340.00 ft² c. N/A R=f t ² 10. Ceiling Types a. Roof Deck (Unvented)R=20.0 1999.00 ft² f t ² R=b. N/A c. N/A R = f t ² 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic 12. Cooling systems 13. Heating systems 14. Hot water systems a. Electric Cap: 1 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:5.624 ft. Area Weighted Average SHGC:0.235 Description Area Insulation Area Insulation Area Insulation Area 15. Credits None 3 (525.3 sqft.) (2102.7 sqft.) (1999.0 sqft.) (1999.0 sqft.) Conditioned floor area below grade (ft²) 0 a. Central Unit a. Electric Strip Heat k B t u / h r 35.2 SEER:16.00 Efficiency k B t u / h r Efficiency 27.0 COP:1.00 f t ² R 6 150 Tankless EF: 0.980 Glass/Floor Area: 0.263 Total Proposed Modified Loads: Total Baseline Loads: 69.21 71.46 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2017 4-24-2020 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY PACE 2000, INC. 1 GARRY WILLIAMS WILLIAMS RESIDENCE Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle:0 No 1 1999 3 New (From Plans) Single-family Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , FORT PIERCE , St. Lucie Street Address Comment: Building Type: User Cross Ventilation:No Whole House Fan:No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer CLIMATE 90 70 7529962 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Entire House 1999 20225.2 Number NameAreaVolume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1M TOILET30300 No 0 Yes Yes1Yes 2 M BATH 110 1100 No 0 Yes Yes1Yes 3M WIC 70 700 No 0 Yes Yes1Yes 4 MASTER BEDROO 295 2950 No 01 Yes Yes1Yes 5 FOYER 105 1050 No 0 Yes Yes1Yes 6 LIVING ROOM 336 3595.2 No 0 Yes Yes1Yes 7 NOOK 221 2210 No 0 Yes Yes1Yes 8 KITCHEN1821820 Yes 0 Yes Yes1Yes 9 BATH 2 104 1040 No 0 Yes Yes1Yes 10 HALL 68 680 No 0 Yes Yes1No 11 LINEN 18 180 No 0 Yes Yes1No 12 CLST 2 18 180 No 0 Yes Yes1No 13 BEDROOM 2 185 1850 No 01 Yes Yes1Yes 14 BEDROOM 3 185 1850 No 01 Yes Yes1Yes 15 CLST 3 18 180 No 0 Yes Yes1Yes 16 LAUNDRY54540 No 0 Yes Yes1Yes # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 1 30 ft² 100______ Slab-On-Grade Edge Insulation - - - -011 ft M TOILET 2 110 ft² 100______ Slab-On-Grade Edge Insulation - - - -013 ft M BATH 4/23/2020 4:49 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 3 70 ft² 100______ Slab-On-Grade Edge Insulation - - - -07 ft M WIC 4 295 ft² 100______ Slab-On-Grade Edge Insulation - - - -033 ft MASTER BEDRO 5 105 ft² 100______ Slab-On-Grade Edge Insulation - - - -07 ft FOYER 6 336 ft² 100______ Slab-On-Grade Edge Insulation - - - -019 ft LIVING ROOM 7 221 ft² 100______ Slab-On-Grade Edge Insulation - - - -013 ft NOOK 8 182 ft² 100______ Slab-On-Grade Edge Insulation - - - -014 ft KITCHEN 9 104 ft² 100______ Slab-On-Grade Edge Insulation - - - -08 ft BATH 2 10 68 ft² 100______ Slab-On-Grade Edge Insulation - - - -01 ft HALL 11 18 ft² 100______ Slab-On-Grade Edge Insulation - - - -01 ft LINEN 12 18 ft² 100______ Slab-On-Grade Edge Insulation - - - -01 ft CLST 2 13 185 ft² 100______ Slab-On-Grade Edge Insulation - - - -016 ft BEDROOM 2 14 185 ft² 100______ Slab-On-Grade Edge Insulation - - - -026 ft BEDROOM 3 15 18 ft² 100______ Slab-On-Grade Edge Insulation - - - -02 ft CLST 3 16 54 ft² 100______ Slab-On-Grade Edge Insulation - - - -06 ft LAUNDRY #Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Flat Concrete 2001 ft² Medium 0.2 20 2.4______No42 ft² 0.9 NoN ATTIC #Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 No attic Unvented 1999 ft² N N0 4/23/2020 4:49 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT #Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Unvented)0 30 ft² 0.1 Wood______M TOILET Blown 2 Under Attic (Unvented)0 110 ft² 0.1 Wood______M BATH Blown 3 Under Attic (Unvented)0 70 ft² 0.1 Wood______M WIC Blown 4 Under Attic (Unvented)0 295 ft² 0.1 Wood______MASTER BEDRO Blown 5 Under Attic (Unvented)0 105 ft² 0.1 Wood______FOYER Blown 6 Under Attic (Unvented)0 336 ft² 0.1 Wood______LIVING ROOM Blown 7 Under Attic (Unvented)0 221 ft² 0.1 Wood______NOOK Blown 8 Under Attic (Unvented)0 182 ft² 0.1 Wood______KITCHEN Blown 9 Under Attic (Unvented)0 104 ft² 0.1 Wood______BATH 2 Blown 10 Under Attic (Unvented)0 68 ft² 0.1 Wood______HALL Blown 11 Under Attic (Unvented)0 18 ft² 0.1 Wood______LINEN Blown 12 Under Attic (Unvented)0 18 ft² 0.1 Wood______CLST 2 Blown 13 Under Attic (Unvented)0 185 ft² 0.1 Wood______BEDROOM 2 Blown 14 Under Attic (Unvented)0 185 ft² 0.1 Wood______BEDROOM 3 Blown 15 Under Attic (Unvented)0 18 ft² 0.1 Wood______CLST 3 Blown 16 Under Attic (Unvented)0 54 ft² 0.1 Wood______LAUNDRY Blown WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 4.1 0M TOILET 000 6 1 0NConcrete Block - Ext Insul 0.20Exterior60.0 ft² ____ 2 4.1 0M TOILET 000 5 1 0WConcrete Block - Ext Insul 0.20Exterior50.0 ft² ____ 3 4.1 0M BATH 000 8 1 0NConcrete Block - Ext Insul 0.20Exterior80.0 ft² ____ 4 4.1 0M BATH 000 5 1 0WConcrete Block - Ext Insul 0.20Exterior50.0 ft² ____ 5 4.1 0M WIC 000 7 1 0WConcrete Block - Ext Insul 0.20Exterior70.0 ft² ____ 6 4.1 0MASTER BE 000 1 8 1 0SConcrete Block - Ext Insul 0.20Exterior180.0 ft² ____ 7 4.1 0MASTER BE 000 1 5 1 0WConcrete Block - Ext Insul 0.20Exterior150.0 ft² ____ 8 4.1 0FOYER000 7 1 0SConcrete Block - Ext Insul 0.20Exterior70.0 ft² ____ 9 4.1 0LIVING ROO 080 1 9 1 0SConcrete Block - Ext Insul 0.20Exterior202.7 ft² ____ 10 4.1 0NOOK000 1 3 1 0NConcrete Block - Ext Insul 0.20Exterior130.0 ft² ____ 11 4.1 0KITCHEN000 1 4 1 0NConcrete Block - Ext Insul 0.20Exterior140.0 ft² ____ 12 4.1 0BATH 2 000 8 1 0NConcrete Block - Ext Insul 0.20Exterior80.0 ft² ____ 13 11 0BATH 2 000 1 3 1 0E Frame - Wood 0.20.1Garage130.0 ft² ____ 14 11 0HALL000 1 2 1 0N Frame - Wood 0.20.1Garage120.0 ft² ____ 15 4.1 0BEDROOM 2 000 1 3 1 0SConcrete Block - Ext Insul 0.20Exterior130.0 ft² ____ 16 4.1 0BEDROOM 2 000 3 1 0WConcrete Block - Ext Insul 0.20Exterior30.0 ft² ____ 17 4.1 0BEDROOM 3 000 1 3 1 0EConcrete Block - Ext Insul 0.20Exterior130.0 ft² ____ 18 4.1 0BEDROOM 3 000 1 3 1 0SConcrete Block - Ext Insul 0.20Exterior130.0 ft² ____ 19 4.1 0CLST 3 000 2 1 0EConcrete Block - Ext Insul 0.20Exterior20.0 ft² ____ 20 4.1 0LAUNDRY000 6 1 0EConcrete Block - Ext Insul 0.20Exterior60.0 ft² ____ 21 11 0LAUNDRY000 9 1 0N Frame - Wood 0.20.1Garage90.0 ft² ____ 4/23/2020 4:49 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1N Low-E Single 0.56 0.23 8.0 ft² 8 ft 0 in 0 ft 0 in NoneVinyl None______Yes1 N 2N Low-E Single 0.56 0.23 8.0 ft² 8 ft 0 in 0 ft 0 in NoneVinyl None______Yes3 N 3S Low-E Single 0.58 0.23 90.0 ft² 8 ft 0 in 0 ft 0 in NoneVinyl None______Yes6 N 4W Low-E Single 0.56 0.23 12.0 ft² 0 ft 0 in 0 ft 0 in NoneVinyl None______Yes7 N 5S Low-E Single 0.3 0.28 48.0 ft² 8 ft 0 in 0 ft 0 in NoneVinyl None______Yes8 N 6S Low-E Single 0.56 0.23 90.0 ft² 8 ft 0 in 0 ft 0 in NoneVinyl None______Yes9 N 7N Low-E Single 0.65 0.21 96.0 ft² 8 ft 0 in 0 ft 0 in NoneVinyl None______Yes10 N 8N Low-E Single 0.56 0.23 8.0 ft² 8 ft 0 in 0 ft 0 in NoneVinyl None______Yes11 N 9N Low-E Single 0.3 0.28 21.3 ft² 8 ft 0 in 0 ft 0 in NoneVinyl None______Yes12 N 10 S Low-E Single 0.58 0.23 60.0 ft² 0 ft 0 in 0 ft 0 in NoneVinyl None______Yes15 N 11 S Low-E Single 0.58 0.23 60.0 ft² 0 ft 0 in 0 ft 0 in NoneVinyl None______Yes18 N 12 E Low-E Single 0.3 0.28 24.0 ft² 0 ft 0 in 0 ft 0 in NoneVinyl None______Yes20 N # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation GARAGE 1 441 ft² 441 ft² 34 ft 10 ft 11______ Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 2359.6 7129.54.00045Wholehouse .1713243.62Proposed ACH(50)1 HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtypeBlockSpeed 1 Electric Strip Heat/COP:1 27 kBtu/hr ______sys#1None1 # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtypeBlockSubtype 1 Central Unit/SEER: 16 35.2 kBtu/hr 1056 cfm 0.8______sys#1Split1 Single # System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Electric 0.98 1 gal 60.9 gal 120 deg None______Tankless LAUNDRY FSEC Company Name System Model #Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert #Area Volume None None f t ² ______ 4/23/2020 4:49 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Location R-Value Area Location Area ---- Supply -------- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 150 ft² Attic 15 ft² Default Leakage Attic (Default) c______1 1 (Default) c TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec [X] Dec[X] Nov [X] Nov [ ] Oct [X] Oct [ ] Sep [ ] Sep [ ] Aug [ ] Aug [ ] Jul [ ] Jul[ ] Jun [ ] Jun [X] Jun [ ] May [ ] May [ ] Apr [X] Apr [X] Mar [X] Mar [X] Feb [ ] Feb [X] Jan [ ] Jan Heating Venting Thermostat Schedule:HERS 2006 Reference Hours Schedule Type 12345678910 11 12 Cooling (WD)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Heating (WD)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area T hickness Furniture Fraction Space Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 M TOILET Default(8 lbs/sq.ft.f t ² f t 0.3 M BATH Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BEDROO Default(8 lbs/sq.ft.f t ² f t 0.3 FOYER Default(8 lbs/sq.ft.f t ² f t 0.3 LIVING ROOM Default(8 lbs/sq.ft.f t ² f t 0.3 NOOK Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 2 Default(8 lbs/sq.ft.f t ² f t 0.3 HALL Default(8 lbs/sq.ft.f t ² f t 0.3 LINEN Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 2 Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 2 Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 3 Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 3 Default(8 lbs/sq.ft.f t ² f t 0.3 LAUNDRY 4/23/2020 4:49 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT