Loading...
HomeMy WebLinkAboutOwner Builder Affidavit (2) `'Florida Building Code Online Page 1 of 2 i� BCIS Home j Log In User Registration I Hot Topics i Submit Surcharge i Stats&Facts i Publications Contact Us BCIS Site Map i Links Search .d Florida i Product Approval ° USER:Public User Product Approval Menu>Product or Application Search>Aoollcation List>Application Detail I u FL# FL5680-R27 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer GAF Address%Phone/Email 1 Campus Drive i Parisppany,NJ 07054 (800)766-3411 mstieh@gaf.com Authorized Signature Robert Nieminen Ireith@nemoetc.com Technical Representative William Broussard Address/Phone/Email 1 Campus Drive Parsippany,NJ 07054 (800)766-3411 lTechnica[QuestionsGAF@gaf.com j . Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Modified Bitumen Roof System 1 ' Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer i- Evaluation Report-Hardcopy Received NNSID sev1e '���� � Florida Engineer or Architect Name who developed Robert J.M.Nieminen the Evaluation Report ®�� ® � � tL Florida License PE 59166 ®� C Quality Assurance Entity UL LLC ,0 9 Quality Assurance Contract Expiration Date 12/06/2022 V.0GG Validated By John W.Knezevich,PE Wj Validation Checklist-Hardcopy Received Certificate of Independence FL5680 R27 COI 2020 01 COI NIEMINEN.odf Referenced Standard and Year(of Standard) Standard Year ASTM D6162 2008 ASTM D6163 2008 ASTM D6164 2011 ASTM D6222 2011 FM 4470 2012 FM 4474 2011 TAS 114 2011 Equivalence of Product Standards Certified By -rile Copy https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgt45H1 a2AP3Iy... 8/3/2020. Florida Building Code Online„ Page 2 of 2 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 02/12/2020 Date Validated .02/13/2020 Date Pending FBC Approval 02/16/2020 Date Approved 04/07/2020 Summary of Products FL# Model,Number or Name Description 5680.1 GAF Modified Bitumen Roof Systems SBS and APP Modified Bitumen Roof Systems Limits of Use Installation Instructions Approved for use in HVHZ:No FL5680 R27 II 2020 02 12 FINAL Al ER FL5680-R27.ndf Approved for use outside HVHZ:Yes Verified By: Robert Nieminen PE-59166 Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure:+N/A/-465 Evaluation Reports Other: 1.)The DP noted herein pertains to one specific FL5680 R27 AE 2020 02 12 FINAL ER FL5680-R27.Ddf system. Refer to the ER Appendix for all systems and max. Created by Independent Third Party:Yes design pressures.2.)Refer to ER Section 5 for Limits of Use. Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: H M Credit Card . Safe https://www.flor'idabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgt45HI a2A P3Iy... 8/3/2020 O. NEMicutc. APPENbix • ORWIND UPLIFT RESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PR[GE� 1A Wood New,Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 6 113 Wood New Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet Bonded Insulation,Bonded Roof Cover -10 iC Wood New,Reroof(Tear-Off),Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover - 0�-13- 1D Wood New,Reroof(Tear-Off),Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover � 14 1E Wood New,Reroof(Tear-Off),Recover C Mech.Attached Insulation,Bonded Roof Cover 14-15 1F Wood New,Reroof(Tear-Off),Recover D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 16 1G Wood New,Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 16-17 1H Wood New,Reroof(Tear-Off),Recover 'E Non-Insulated,Mech:Attached Base Sheet,Bonded Roof Cover 18 11 Wood New,Reroof(Tear-Off) F Non-Insulated;Bonded Roof Cover 18 2A Steel or Structural concrete New,Reroof(Tear-Off),Recover B-1 Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 19-28 2B Steel or Structural concrete New,Reroof(Tear-Off),Recover B-2 Mech.Attached Thermal Barrier,Bonded Temp Roof,Bonded Insulation,Bonded Roof Cover 29-33 2C Steel or Structural concrete New,Reroof(Tear-Off),Recover C-1 Mech.Attached Insulation,Bonded Roof Cover 34744 2D Steel or Structural concrete New,Reroof(Tear-Off),Recover C-1A Thermal Barrier with Vapor Barrier,Mech.Attached Insulation,Bonded Roof Cover 45 2E Steel or Structural concrete New,Reroof(Tear-Off),Recover C-2 Bonded and Mech.Attached Insulation,Bonded Roof Cover 45 2F Steel or Structural concrete New,Reroof(Tear-Off),Recover D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 46-49 3A Structural concrete New,Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover(Base Insulation Layer Only) 50-53 3B Structural concrete New,Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover(Base and Top Insulation Layers) 54-63 . 3C Structural concrete New,Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 64 4A Lightweight concrete New,Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 65-67 46 Lightweight concrete New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 68 4C Lightweight concrete New,Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 69-72 4D Lightweight concrete New,Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 72 5A Cementitious wood fiber New,Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 73 5B Cementitious wood fiber New,Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Banded Roof Cover " 74 5C Cementitious wood fiber New,Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 75 6A Gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 76 66 Gypsum Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 77 6C Gypsum Reroof(Tear-Off) C Mech.Attached Insulation,Bonded Roof Cover 77 6D Gypsum Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 78 7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover(Base Insulation Layer.Only) 79-88 7B Various Recover A-1 Bonded Insulation,Bonded Roof Cover(Base and Top Insulation Layers) 89-106 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Unless otherwise noted,fasteners and stress plates for insulation or base sheet attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: ➢ Wood: - Drill-Tec#12 Fastener or Drill-Tec#14 Fastener with Drill-Tec 3"Standard Steel Plate,Drill-Tec 3"Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate.(insulation: only),Drill-Tec ASAP 3S,Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a-3"Metal Plate,Drill-Tec#12 DP Fastener or Drill-Tec#14 HD Fastener with Drill-Tec 3"Flat Steel Plate, Drill-Tec#12 DPH Fastener with Drill-Tec 3"Recessed Steel Plate,Drill-Tec 3"ASAP Flat or Drill-Tec 3"ASAP Recessed. Minimum 0.75-inch plywood penetration or minimum 1-inch wood plank embedment. NEMO ETC,LLC Evaluation Report 01506.11.04-R27 for FL5680-R27 J' Certificate of Authorization#32455 — - — 67H EDITION-(2017)-FBC NON-HV.HZ_EVALUATION _ Revision 27:02/12/2020 02019 NEMO ETC,LLC GAF Modified Bitumen Roof Systems;(800)766-3411 Appendix 1,Page 1 of 106 NNEMOjetc. ➢ Steel: Drill-Tec#12 Fastener,Drill-Tec#14 Fastener or Drill-Tec XHD Fastener with Drill-Tec 3"Standard Steel Plate,Drill-Tec 3"Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate(insulation only);Drill-Tec ASAP 3S;Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3"Metal Plate;Drill-Tec Extra Heavy Duty ASAP Roofing Fastener-Insulation, Drill-Tec#12 DP Fastener,Drill-Tec#14 HD Fastener or Drill-Tec#15 EHD Fastener with Drill-Tec 3"Flat Steel Plate,Drill-Tec#12 DPH Fastener with Drill-Tec 3"Recessed Steel Plate,Drill-Tec 3"ASAP Flat or Drill-Tec 3"ASAP Recessed. Minimum 0.75-inch steel penetration and engage the top flute of the steel deck. ➢ Structural concrete: Drill-Tec#14 Fastener or Drill-Tec CD-10 with Drill-Tec 3"Standard Steel Plate,Drill-Tec 3"Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate(insulation only), Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3"Metal Plate,Drill-Tec#14 HD Fastener with Drill-Tec 3"Flat Steel Plate or Drill-Tec 3"ASAP Flat(#14 only). Minimum 1-inch embedment into pilot hole in accordance with the fastener manufacturer's published installation instructions. 3. Unless otherwise noted,insulation may be any one layer or combination of polyisocyan u rate,polystyrene,wood fiberboard,perlite,gypsum-based roof board or mineral wool roof board that meets the QA requirements of F.A.C.Rule 61G20-3 and is documented as meeting FBC 1505.1 and,for foam plastic,Chapter 26,when installed with the roof cover. VersaShield®Solo'"Fire-Resistant Slip Sheet may be used as a non-load-bearing, fire-barrier slip-sheet component within any system outlined herein. 4. Minimum 200 psi,minimum 2-inch thick lightweight insulating concrete may be substituted for,or installed beneath rigid insulation board for System Type D(mechanically attached base sheet,bonded roof cover), whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5. Preliminary insulation attachment for System Type D:Refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29(January 2016). 6. Unless otherwise noted,insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢ Hot asphalt: Full coverage at 25-30 Ibs/square ➢ OMG OlyBond 500(OB500): Continuous 0.75-inch wide ribbons,12-inch o.c.using PaceCart,SpotShot or Canister dispensers. Note: OlyBond Classic or OlyBond 500 Green may be used where OlyBond 500 is referenced. ➢ GAF LRF Adhesive M(LRF-M): Continuous 1-inch wide ribbons,12-inch o.c ➢ H.B.Fuller Millennium One-Step Foamable Adhesive(M-OSFA): Continuous 1-inch wide ribbons,12-inch o.c. ➢ GAF 2-Part Roofing Adhesive(GAF 2-Part): Continuous 2.5 to 3-inch wide ribbons,12-inch o.c. ➢ Note: When multiple layers(s)of insulation and/or coverboard are installed in ribbon-applied adhesive,board joints shall be staggered. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted,all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyan u rate at the following thickness limitations may be substituted with the following Maximum Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MOP listings in the tables;rather if MDP listing below meets or exceeds that listed for a particular system in the tables,then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table. ➢ Hot asphalt: MDP -240.0 psf (Min.0.5-inch thick) ➢ OlyBond 500(013500): MDP -292.5 psf (Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard NH Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation, EnergyGuard NH Ultra Polyiso Insulation) ➢ OMG OlyBond 500(OB500): MDP -315.0 psf (Min.0.5-inch thick EnergyGuard RH or RN) ➢ OMG OlyBond 500(OB500): MDP -485.0 psf (Min.0.5-inch thick EnergyGuard RA) ➢ GAF 2-Part Roofing Adhesive(GAF 2-Part): MDP -117.5 psf (Min.1.0-inch thick) 8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 9. For mechanically attached components or partially bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16,and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1,FM Loss Prevention Data Sheet 1-29,Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. 10. For fully bonded assemblies,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16,and no rational analysis is permitted. 11. For mechanically attached components over existing decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Stanard TAS 105. NEW ETC,LLC Evaluation Report 01506.11.04-R27 for FL5680-R27 Certificate of Authorization#32455 EP EDITION(2017)FBC NON-HVHZ EVALUATION Revision 27:02/12/2020 ©2019 NEMO ETC,LLC GAF Modified Bitumen Roof Systems;(800)766-3411 Appendix 1,Page 2 of 106 tom• ONEMOQtc. 12. For existing substrates in a bonded recover or re-roof installation,the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive,and the exi ting roof system(for recover)shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction,as documented through field uplift testing in accordanc�ith ANSI/SPRI IA-1,ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13. For Recover Applications using System Type D, the insulation is optional. Alternatively, min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard NH Polyiso Insulation, EnergyGuard Ultra Polyiso Insu at' n, EnergyGuard NH Ultra Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra, Structodek High Density Fiberboard Roof Insulation, EnergyGuard RH HD Polyiso Insu tion, EnergyGuard HD Polyiso Insulation, EnergyGuard NH HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation or EnergyGuard NH HD Plus Polyiso Insulation or min.0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass-Mat Roof Board may be used as a separator board prior to base sheet installation. The existing roof system shall be suitable for a recover application. The separator component shall be documented as meeting FBC 1505.1 and,for foam plastic,FBC 2603.4.1 or 2603.6,when installed with the roof cover in Recover applications. 14. Lightweight insulating concrete(LWIC)shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced,refer to current LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted,for systems where specific LWIC is not'referenced,the minimum design mix shall be 300 psi. In all cases,the minimum top-coat thickness is 2-inches. For LWIC over structural concrete,reference is made to FBC Section 1917.4.1,Point 1. For"pre-existent'LWC references,listings were established through testing over lightweight concrete cast using only foaming agent(ASTM C896),water and Portland cement(ASTM C150),with no proprietary additives,in accordance with procedures adopted by Miami-Dade BCCO(FBC CER1592). Unless otherwise noted, use of these listings in new construction or re-roof(tear-off)applications is at the discretion of the Designer or Record and Authority Having Jurisdiction. 15. Unless otherwise noted,refer to the following references for bonded base,ply or cap sheet applications. - •` ° GAF ROOF COVER/ADHESNE COMBINATIONS - REFERENCE. LAYER MATERIAL APPLICATION BP-AA Base Ply: GAFGLAS#75 Base Sheet,Tri-Ply#75 Base Sheet,GAFGLAS#80 Ultima Base Sheet Hot asphalt at 25 Ibs/square. (Base/Ply sheets,Asphalt-Applied) Ply: One or more plies GAFGLAS Ply 4,Tri-Ply Ply 4 Ply Sheet,GAFGLAS FlexPly 6 BP-CA Base Ply: GAFGLAS#75 Base Sheet,Tri-Ply#75 Base Sheet Matrix'"'102 SBS Membrane (Base/Ply sheets,Cold-Applied) Adhesive at 1.5 gal/sq. Base Ply or Ply: One or two plies Ruberoid 20 Smooth,Ruberoid Mop Smooth,Ruberoid Mop Smooth 1.5,Ruberoid Mop Plus Smooth SBS-AA Ruberoid 30 Granule,Ruberoid 30 Granule FR,Ruberoid EnergyCap 30 Granule FR,Ruberoid Mop Smooth,Ruberoid (SBS,Asphalt-Applied) Cap Ply: Mop Smooth 1.5,Ruberoid Mop Plus Smooth,Ruberoid Mop Granule FR,Ruberoid Mop Granule,Tri-Ply SBS Granule Hot asphalt at 25 Ibs/square. Cap Sheet,Intec Flex PRF,Ruberoid Mop Plus Granule FR,Ruberoid Mop Plus Granule,Ruberoid EnergyCap Mop Plus Granule FR Base Ply or Ply: Ruberoid 20 Smooth SBS-CA Matrix'"'102 SBS Membrane (SBS,Cold-Applied) Cap Ply: Ruberoid 30 Granule FR,Ruberoid EnergyCap 30 Granule FR,Ruberoid Mop Granule FR,Ruberoid Mop Plus Granule Adhesive at 1.5 gal/sq. FR,Ruberoid EnergyCap Mop Plus Granule FR Base Ply: Ruberoid 20 Smooth or Ruberoid Mop Smooth 1.5 Matrix"101 Premium SBS SBS-CAl Ruberoid 30 Granule FR,Ruberoid EnergyCap 30 Granule FR,Ruberoid Mop Plus Granule FR,Ruberoid EnergyCap Mop Membrane Adhesive at 1.5— (SBS,Cold-Applied) Cap Ply: Plus Granule FR 2.0 gal/square SBS-TA Base Ply or Ply: One or two plies Ruberoid HW 25 Smooth,Ruberoid HW Smooth (SBS,Torch-Applied) Cap ply: Ruberoid HW Granule,Ruberoid HW Granule FR,Ruberoid HW Plus Granule,Ruberoid HW Plus Granule FR,Ruberoid EnergyCap HW Plus Granule FR Torch applied APP-TA Base Ply or Ply: One or two plies Ruberoid Torch Smooth,Tri-Ply APP Smooth Membrane (APP,Torch-Applied) Cap Ply: Ruberoid Torch Granule,Tri-Ply APP Granule Membrane,Ruberoid Torch Plus Granule FR,Ruberoid EnergyCap Torch Granule FR,Ruberoid EnergyCap Torch Plus Granule FR SBS-SA(self-adhering) Base Ply or Ply: Liberty SBS Self-Adhering Base/Ply Sheet Self-adhered Cap Ply Liberty SBS Self-Adhering Cap Sheet NEMO ETC,LLC Evaluation Report 01506.11.04-R27 for FL5680-1127 Certificate of Authorization#32455 — -- -- — 6T"EDITION-(2017)-FBC NON-HVHZ.EVALUATION-__ _ _ Revision 27:02/12/2020 ©2019 NEMO ETC,LLC GAF Modified Bitumen Roof Systems;(800)766-3411 Appendix 1,Page 3 of 106 OMEMO I etc. 16. Vapor barrier options for over structural concrete deck with adhered insulation carry the following Maximum Design Pressure(MDP)limitations. The lesser of the MDP listings below vs.those in Table 3A applies: VAPOR BARRIER OPTIONS;STRUCTURAL CONCRETE DECK;ADHERED INSULATION,PER TABLE 3A OR 38 OPTION VAPOR BARRIER MOP PRIMER INSULATION ADHESIVE # TYPE ATTACH (PSF) C-VB-1. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies,GAFGLAS#75 Base Sheet,Tri-Ply#75 Base Hot asphalt applied Hot asphalt -360.0 Sheet,GAFGLAS Ply 4,Tri-Ply Ply 4 or GAFGLAS FlexPly 6 C-VB-2. GAF SA Primer Ruberoid SA Universal Base Sheet Self-adhering GAF 2-Part,12-inch o.c. -157.5 C-VB-3. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Granule Torch-applied GAF 2-Part,12-inch o.c. -169.0 C-VB-4. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth or Ruberoid HW Smooth Torch-applied GAF 2-Part,12-inch o.c. -180.0 C-VB-5. GAF SA Primer GAF SA Vapor Retarder Self-adhering GAF 2-Part,12-inch o.c. -202.5 C-VB-6. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Liberty SBS Self-Adhering Cap Sheet Self-adhering GAF 2-Part,12-inch o.c. -250.0 C-VB-7. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies,GAFGLAS#75 Base Sheet,Tri-Ply#75 BaseSheet,GAFGLAS Ply 4,Tri-Ply Ply 4 Ply Sheet or GAFGLAS FlexPly 6 Hot asphalt applied GAF 2-Part,12-inch o.c. 262.5 C-VB-8. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid 30 Hot asphalt applied GAF 2-Part,12-inch o.c. -270.0 C-VB-9. GAF SA Primer Ruberoid SA Universal Base Sheet Self-adhering LRF-M,12-inch o.c. -157.5 C-VB-10. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth or Ruberoid HW Smooth Torch-applied LRF-M,12-inch o.c. -180.0 C-VB-11. GAF SA Primer GAF SA Vapor Retarder Self-adhering LRF-M,12-inch o.c. -202.5 C-VB-12. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies,GAFGLAS#75 Base Sheet,Tri-Ply#75 Base Hot asphalt applied LRF-M,12-inch o.c. -495.0 Sheet,GAFGLAS Ply 4,Tri-Ply Ply 4 Ply Sheet or GAFGLAS FlexPly 6 C-VB-13. GAF SA Primer Ruberoid SA Universal Base Sheet Self-adhering OlyBond 500,12-inch o.c. -157.5 C-VB-14. Matrix 307 Premium-Asphalt Primer or ASTM D41 primer Ruberoid Torch Smooth Torch-applied OlyBond.500,12-inch o.c. -165.0 C-VB-15. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth Torch-applied OlyBond 500,12-inch o.c. -180.0 C-VB-16. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Liberty SBS Self-Adhering Cap Sheet Self-adhering OlyBond 500,12-inch o.c. -187.5 C-VB-17. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid 20 Smooth Matrix 102 SBS Membrane OlyBond 500,12-inch o.c. -202.5 Adhesive at 1.5 gal/square C-VB-18. GAF SA Primer GAF SA Vapor Retarder Self-adhering OlyBond 500,12-inch o.c. -202.5 C-VB-19. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Granule Torch-applied OlyBond 500,12-inch o.c. -225.0 C-VB-20. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW Smooth Torch-applied OlyBond 500,12-inch o.c. -232.5 C-VB-21. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies,GAFGLAS#75 Base Sheet,Tri-Ply#75 Base Hot asphalt applied OlyBond 500,12-inch o.c. -352.5 Sheet,GAFGLAS Ply 4,Tri-Ply Ply 4 Ply Sheet or GAFGLAS FlexPly 6 MEMO ETC,LLC Evaluation Report 01506.11.04-R27 for FL5680-1127 Certificate of Authorization#32455 CH EDITION(2017)FBC NON-HVHZ EVALUATION Revision 27:02/12/2020 02019 NEMO ETC,LLC GAF Modified Bitumen Roof Systems;(800)766-3411 Appendix 1,Page 4 of 106