HomeMy WebLinkAboutDrawingIdentification Schedule for Opening Protective Device or System (The following minimum information shall be provided to facilitate plan review and'inspection of the proposed installation, opening, protective device orsystenz) Address: 1805 HAZELWOOD DR, FORT PIERCE, FL 34982 Tyne of Structure: PERMIT #: Dev. # Device Type Device Manufacturer Approval Opening Width Opening Height Shutter Width Shutter Height # Storm Bars Reg. Anchor Spacing Header Reinf. Re 1. NOT COVERED NOT COVERED 'No 2. Accordion Town & Country FBC 13757 243 100.5 266 100.5 N/A 12" No ALL AMERICAN SHUTTERS & GLASS 1638 Donna Road, Wbs;t Palm Beach, 'FL 38409 (561) 7*12-9882 w Av.a,llamericanshuiteis.00m Information Owner: HOLBERTON JESSICA Address: 1805 HAZELWOOD DR FORT PIERCE, FL 34982 Building Information Wind Zone: 170 MPH. Exposure Category: B Minimum Building Dimension: 50 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device FHeight (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 7 0.0 0.0 2 Int 266 100.5 7 25.2 -27.9 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads -Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1