HomeMy WebLinkAboutDrawingIdentification Schedule for Opening Protective Device or System
(The following minimum information shall be provided to facilitate plan review and'inspection of the proposed installation, opening, protective device orsystenz)
Address: 1805 HAZELWOOD DR, FORT PIERCE, FL 34982 Tyne of Structure: PERMIT #:
Dev.
#
Device
Type
Device
Manufacturer
Approval
Opening
Width
Opening
Height
Shutter
Width
Shutter
Height
# Storm
Bars Reg.
Anchor
Spacing
Header
Reinf. Re
1.
NOT COVERED
NOT COVERED
'No
2.
Accordion
Town & Country
FBC 13757
243
100.5
266
100.5
N/A
12"
No
ALL AMERICAN
SHUTTERS & GLASS
1638 Donna Road, Wbs;t Palm Beach, 'FL 38409
(561) 7*12-9882 w Av.a,llamericanshuiteis.00m
Information
Owner: HOLBERTON JESSICA
Address: 1805 HAZELWOOD DR
FORT PIERCE, FL 34982
Building Information
Wind Zone: 170 MPH.
Exposure Category: B
Minimum Building Dimension: 50 ft.
Mean Roof Height: 15 ft.
Risk Category: II
Design Pressure Calculations
Opening
Number
Location
Zone
Device
Width (in)
Device
FHeight (in)
Device
Elevation (ft)
Max Positive
Pressure (psf)
Max Negative
Pressure (psf)
1
Int
7
0.0
0.0
2
Int
266 100.5 7
25.2
-27.9
Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads -Components and Cladding. 6th Edition (2017) Florida Building Code.