Florida Building Code Online
FL #
FL27499-R1
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Year
Archived
1995
Product Manufacturer
Dynamic Metals
Address/Phone/Email
3201 SE Dominica Terace
Stuart, FL 34997
(772)872-8030
juan@dynamicmetal.net
Authorized Signature Lara )esus
juan@dynamicmetal.net
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Scott Wolters
Evaluation Report
Florida License PE -62354
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/31/2026
Validated By Lucas A. Turner, P.E. MBA
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
Validation Checklist - Hardcopy Received
FL27499 Rl COI Dyn COI.pdf
Standard
Year
TAS 100
1995
TAS 110
2003
TAS 125
2003
https://www.floridabuilding.org/prlpr_app_dtl,aspx?param=wGEVXQvvtDquHOE2Ywe%2bOsCepABg3°/a2bkM6B4KrS3X7m7RLNDTr%2fv7QaQ°/a3d°/o... 1/4
4/10/2020 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
FL #
27499.1
Model, Number or Name
DM Class 1000 1" Nailstrip
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eva[ report for Limits of Use.
27499.2 1 DM Class 1000 1" Nailstrip,
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
02/22/2019
08/29/2019
08/30/2019
10/15/2019
27499.3 1 DM Class 1050 1 1/2" Nailstrip
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
27499.4 ( DM Class 1050 1 1/2" Nailstrip
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
1 27499.5( DM Class 1500 1 1/2" Mechanical
Seam
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
27499.6( DM Class 1500 1 1/2" Mechanical
Seam
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
27499.7( DM Class 1500 1 1/2" Mechanical
Seam
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Description
26 Ga. galvalume coated steel roof panel, 16" wide, with 1"
snap fit seams.
Installation Instructions
FL27499 Rl II NSSI6HZ.pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 RI AE DM Evall pdf
Created by Independent Third Party: Yes
.032" Aluminum roof panel, 16" wide, with 1" snap fit seams.
Installation Instructions
F1,27499 RI II NSAI6HZ pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 R1 AE DM Eva12 pdf
Created by Independent Third Party: Yes
.032" Aluminum Roof Panel, 19" Wide, with 1 1/2" snap fit
seams,
Installation Instructions
FL27499 RI II NSAI9HZ pdf
Verified By: Scott Wolters, PE. FLPE# 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 Rl AE DM Eva]3.pdf
Created by Independent Third Party: Yes
24 Ga. Galvalume coated steel roof panel, 19" wide, with 1
1/2" snap fit seams
Installation Instructions
FL27499 RI II NSSI9HZ.pdf
Verified By: Scott Wolters, P.E. FLPE# 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 Rl AE DM Eval4 pdf
Created by Independent Third Party: Yes
.032" Aluminum roof panel, 20" wide, with 1 1/2" standing
seams.
Installation Instructions
FL27499 R1 II 15MSA20HZ Pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 R1 AE DM Eval5.pdf
Created by Independent Third Party: Yes
16 oz. Copper roof panel, 16" wide, with 1 1/2" standing
seams.
Installation Instructions
FL27499 Rl II 15MSCHZ.pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 RI AE DM Eval6.pdf
Created by Independent Third Party: Yes
26 Ga. galvalume coated steel roof panel, 16" wide, with 1 1/2"
standing seams.
Installation Instructions
FL27499 RI II 15MSS1626HZ.pdf
Verified By: Scott Wolters 62354
https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABg3%2bkM6B4KrS3X7m7RLNDTr%2fv7QaQ°/ 3d%... 2/4
ENGINEERING, DRAFTING, CONSULTING
PRODUCT
MANUFACTURER
To all concerned,
15211 971^ Road N
West Palm Beach, FL 33412
Ph/Fx: (561) 225-1982
PRODUCT EVALUATION
(FOR HVHZ APPROVED PRODUCT)
DM CLASS 1500 .032" ALUMINUM 1%" MECHANICAL SEAM 20" WIDE
ROOF PANEL (FLPA# 27499.5)
DYNAMIC METALS, LLC
340 PIKE ROAD
WEST PALM BEACH, FL 33411
The DM Class 1500 Series .032" Aluminum 1'/2" Mechanical Seam 20" Roof Panel, manufactured by
Dynamic Metals LLC, is a non-structural Fluropon painted aluminum roof panel (25 ksi min) that meets the
requirements of Sections 1507,4 and 1518.9 of the 6th Edition (2017) Florida Building Code. The panel has been
tested per TAS 100 and TAS 125 by Intertek, with results shown in test reports G3443.43-450-44 and H2687.02-
450-44, and per TAS 110 by PRI Construction Materials Technologies, with results shown in test reports VLS-004-
02-01 and VLS-005-02-01.
Technical Documentation:
1. Drawing "15MSA20-HZ' dated 8/15/19, signed and sealed by Scott Wolters, PE,
2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE, and
by PRI Construction Materials Technologies, signed and sealed by Zachary R Priest, PE,
3. Supplemental Calculations to support "15MSA20-HZ" drawing, signed and sealed by Scott Wolters,
PE.
I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61G20-3.005
(4). Based on the limitations listed below and those provided in the documents above, this product meets all the
requirements of the 6th Edition (2017) Florida Building Code generally, and chapter 15 specifically, including the
HVHZ provisions.
Limitations: This panel is approved for use inside and outside of the HVHZ.
Overall Limitations: Maximum Panel Width: 20"
Minimum Rib Height: 1 %'
Clip Anchors: 26 Ga galvanized steel, 2" long
Min. Slope: HVHZ: 2'/12"
Non-HVHZ: ''/i/12"
5FLCIAIZIN6 IN IMPACTF55fANI CUP1"AINWAI,I-5, 510FFFF0Nr5, & WINDOWS
Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current
fire directory listing for fire ratings of this roofing system assembly as well
as the location of the fire barrier within the assembly. (See note #2 below)
Note: Outside of the HVHZ, 1" round plastic caps may be used to prevent
galvanic reactions.
Underlayment: Minimum ASTM D 226 Type II with 4" overlaps and 6" end -laps, anchored
with 12 Ga. x 1 '/" galvanized roof nails with 32 Ga. Tin caps spaced 6"
O.C. in rows at the perimeter, at overlaps, and two intermediate rows
staggered and spaced 12" O.C.
(or)
Any underlayment with a valid FLPA or Miami -Dade NOA
Note: Outside of the HVHZ, 1" round plastic caps may be used to prevent
galvanic reactions.
Minimum Substrate: %' (15/32" min) 4 -ply CDX Plywood, nailed to 2x rafters spaced 24" max.
O.C. with 8d ring -shank nails spaced 4" O.C.
Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or
1515,2.
2. Fire classification is not a part of this evaluation. Refer to a current
Approved Roofing Materials Directory for fire ratings of this product.
3. Design of substrate is by others and is not a part of this evaluation.
4. Rational analysis, provided by a Florida licensed Architect/Engineer
per FAS 61 G20.3.005(e), may be used for project specific approval by
the local authorities having jurisdiction.
5. All panels shall be permanently labeled with the manfacturer's name
and/or logo, and the following statement, "Dynamic Metals
FL# 27499.5, DM Class 1500".
5 fCIA RING IN IMPACT Y.H5fANTCUp1AINWAU,5, 5fOfffF0NT5, & WINPOWS
Field
Installation
Perimeter & Corner
Installation
Max. Design Pressure:
-156 psf
-198.5 psf
Clip Anchor Spacing:
4" From Ends, 13" Max. O.C.
4" From Ends, 101/2" Max. O.C.
Min Panel Fasteners:
#10x1" Panclip Fasteners
(2) Per_Clip
#10x1" Panclip Fasteners
(2) Per Clip
Panels are Seamed to 900
Panels are Seamed to 90°
Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current
fire directory listing for fire ratings of this roofing system assembly as well
as the location of the fire barrier within the assembly. (See note #2 below)
Note: Outside of the HVHZ, 1" round plastic caps may be used to prevent
galvanic reactions.
Underlayment: Minimum ASTM D 226 Type II with 4" overlaps and 6" end -laps, anchored
with 12 Ga. x 1 '/" galvanized roof nails with 32 Ga. Tin caps spaced 6"
O.C. in rows at the perimeter, at overlaps, and two intermediate rows
staggered and spaced 12" O.C.
(or)
Any underlayment with a valid FLPA or Miami -Dade NOA
Note: Outside of the HVHZ, 1" round plastic caps may be used to prevent
galvanic reactions.
Minimum Substrate: %' (15/32" min) 4 -ply CDX Plywood, nailed to 2x rafters spaced 24" max.
O.C. with 8d ring -shank nails spaced 4" O.C.
Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or
1515,2.
2. Fire classification is not a part of this evaluation. Refer to a current
Approved Roofing Materials Directory for fire ratings of this product.
3. Design of substrate is by others and is not a part of this evaluation.
4. Rational analysis, provided by a Florida licensed Architect/Engineer
per FAS 61 G20.3.005(e), may be used for project specific approval by
the local authorities having jurisdiction.
5. All panels shall be permanently labeled with the manfacturer's name
and/or logo, and the following statement, "Dynamic Metals
FL# 27499.5, DM Class 1500".
5 fCIA RING IN IMPACT Y.H5fANTCUp1AINWAU,5, 5fOfffF0NT5, & WINPOWS
Panel Forming: These panels may be jobsite roll formed with the following Dynamic Metals machines, per
approval of 31d party CIA provider, to the dimensions shown on Drawing 15MSA20-HZ:
SSO-6800617 SSQ-5150216 SSQ-6810617
SSO-6690517 SSQ-4560615 SSQ-8681118
5VC-0490718 5VC-0360516 5VC-052121 8
Re -Roofing: The DM Class 1500 Series .032" Aluminum 1 Y2" Mechanical Seam 20" Roof Panel may
be installed over a single layer of existing asphalt shingles, provide the existing roof meets
the requirements of Section 1521 (HVHZ) or Section 1511 (outside of HVHZ) of the
Florida Building Code,
If you have any questions or need more information concerning this approval please contact me.
Thank you,
0 � i I A
�00�
C'o Vv
F N
No 62354
FI_ PEff 62354
AUG 69 71f'1
'°. - STATE OF 4u
0 R k
r� A
9KCIA ZIN(4 IN UPA(' , I , 0`515TAN'r CURIANALL, ,, PUNI'7 & 4AiNt2(7/v5
C)
N
SIV13N -DINVNA(J
I
I
10
z
1-71 LU
cl
ld
Y3o
t3
LLI
ui
CL
0
0
LO
qL—
cn
C4
Cl
I
I
10
z
1-71 LU
Y3o
t3