Loading...
HomeMy WebLinkAboutProduct Evaluation Report; Structural Wall. Force Engineering & Testing Inc. 195M RambLe d Drive H.b1gTX 77338 Product Evaluation Report t CARPORTS ANYWHERE Hampton Rib Wall Panel over open framing Florida Product Approval # 27403.1 Florida Building Code 2017 Per Rule 61G20.3 Method:2-B Category: Structural Components Subcategory: Structural Wall Compliance Method: 61G20-3.005(2)(b) NON HVHZ Product Manufacturer: Carport Anywhere 10858 S.E. County Road 221 Starke, Florida 32091 Engineer Evaluator: Terrence E. Wolfe, P.E. # 44923 Florida Evaluation ANE ID: 1920 Validator• Gary Hartman, P.E. #73227 Contents: Evaluation Report Pages 1-4 Se�mr,eL 006 /IAl1 FL# 27403.1 ``t�in+r rlirgr' C E, r CE HSB STATE Sl� STATE OF , JV*Lt/ is, toss Force Engineering:Testing Inc. 19530 Rxmblewood D» vc Hmnbl.,TX 77339 Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Cade 2017, Sections 1709.2. Product Description: Hampton Rib 26 Ga. and 29 Ga. Steel Wall Panel, 36" Wide, through fastened structural wall panel. Structural Applicatlon. Panel Material/Standards: Material: 26 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 50 29 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade Bo Conforming to Florida Building Code 2017 Section 1405.2. Panel Dimension(s): Thickness: 26 Ga.: 0.0185" min. order thickness 29 Ga.: 0.0142" min. order thickness Width: 36"'maximum coverage Rib Height Y." major rib at 9" O.C. Panel Rallformer: MRS Metal Rollforming Systems Panel Fastener: #12-14 x Y." HWH SDO with 14mm neoprene bonded washing or approved equal. ' Corrosion Resistance: Per Florida Building Code 2017. Substrate Description: Minimum 14 Ga. (Grade 501 Steel framing,. Minimum 16 Ga. (Grade 50) Steel framing, or Minimum 18 Ga. (Grade 50) Steel framing. See Table A & B for steel ' gauge. Framing must be designed in accordance w/ Florida Building Code 2017. Allowable Design Pressures: Table "A" 26 Ga. Hammon Rib Wall Panel Maximum resign Pressure: -57.3 psf -72.9 psf -67.7 psf +46.9 psf +54.7 psf Panel Fastener Pattern: 2-1-2-1 2-1-2-1 2-1-2.1 2-1-2.1 2-1.2-1 Panel Span: S'-0" O.C. 4'-0" O.C. 4'-0" O.C. S'-0" O.C. 4'-W O.C. Substrate: Min. 14 Ga. Steel Framing Min. 14 Ga. Steel Framing Min. 14 Ga. Steel Framing Min. 18 Ga. Steel Framing Min. 18 Ga. Steel Framing •Design Pressure includes a Safety Factor= 2.0. FL# 27403.1 No. 449 STATEOF :W se.wrw �i fs •. 1 �� O 1111is" ,, Jll qt 18, 2-018 r,orce Engtncenng &c Testing Inc. 195301tamblewood Dme Humble,TX 77338 Table "B" 29 Ga. Bamoton Rib Wall Panel Maaimum Design Pressure: -57.3 psf -1509 psf +39.0 psf +143.1 psf Fastener Pattern: 6"-3"-6"-3„-6'd"-6° 6"3"-6,=3"-6"-3"-6" 6"-3"-6"-3'-6"-3"-6" 6"-3"-6"-3"fi"-3"-6" Fastener Spacing: 4'-W O.C. 2'-0" O.C.4'-V O.C. T-W O.C. •Design Pressure includes a Safety Factor= 2.0. Code Compliance: The product described herein has demonstrated compliance with The Florida Building Cade 2017, Section 1709.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Cade 2017, as relates to Rule 61G20-3. Performance Standards: The product described herein has demonstrated compliance with: • ASTM E 1592-05 (2012) Test method for structural performance of sheet metal roof and siding systems by uniform static air pressure difference Reference Data: 1. ASTM E 1592-05 (2012) Test Force Engineering &Testing, Inc. (FBC Organization N T5T-5328) Report No. 667-DO60T-SSA-E, 667-0061T-ISA-D 2. Certificate of Independence By Terrence E. Wolfe, P:E. (No. 44923) @ Farce Engineering & Testing, .Inc. (FBC Organization # AN ID: 1920) Quality Assurance Entity: The manufacturer has established compliance of roof panel products In accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. Installation: Install per manufacturer's recommended details. Insulation: Manufacturer's approved product (Optional) ' Panel Fire Classification: Fire classification is not part of this acceptance. E I- v,, i C E ry NO. 40 •"• • SPATE OF m.arie• '�� • AL 0 P FL# 27403.1 Ja*Le,18, 2018 Force Enigincering & Testing Inc. 19530 Ramblewood Drive Humble,TX 77338 Shear Diaphragm: Shear diaphragm values are outside the scope of this report. Design Procedure: Based on the dimensions of the structure, appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2017 for wall dadding wind loads. These component wind loads for wall cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with Florida Building Code 2017 Chapter 22 for steel, and Chapter 16 for structural loading. `,,`punttgrr i CE I4SF:A��irr •^ • STATE OF : C �13, 0RID�s..�rru �i Ps; • 1. �� FU 27403.1 jV hx& 18, 2018 D 26 GA. HAMPTON RIB FASTENER PATTERN 2-1-2-1 #12-14 x 3/4' HWH S03 W/ 14MM BONDED NEOPRENE WASHER 29 GA. HAMPTON RIB FASTENER PATTERN 6"-3"-6"-3"-6"-3"-6" 6• 3' 6" 3' 6' 3• 6' #12-14 x 3/4" HWH SD3 W/ 14MM BONDED NEOPRENE WASHER \\IUUIIIII/ryAA�A OfwAs olane A'o.44923�'_ STAT 0� ;M182018