Loading...
HomeMy WebLinkAboutEngineering Submittal-DigiCert, Island Dunes, 7.16.20fro� Aw1h Fuck:51 \\�\��01N G. HUrC i �O ,-'"�iC by � This item has been electronically signed 3 N and sealed by Bowdoin G. Hutchinson, P.E. Hulchlil�vz Island Tenser, using a Digital Signature and Date. Printed Pivot Rio * = copies of this document are not considered iX-( OP ��\ signed and sealed and the signature must _ �i ds ORIDA ,-' ak' �' be verified on any electronic copies. 4 ONA I I IENG\\\\�� Stuart c ny �nTsen r Wet jwl t " ItI fdnc� i�a ll.fe�N u u'tyy.• i �k1IJ Bowdoin G. Hutchinson DN: c=US, st=Florida, I=Fort Pierce, o=Bowdoin G. Hutchinson, cn=Bowdoin G. Hutchinson Date: 2020.07.16 20:27:22 -04'00' Adobe Acrobat version: 2020.009.20074 F8o6 enchmark Engineering Island Dunes the Treasure Coast LLC 8735 South Ocean Drive 1 Owdoirl G, Hutchinson f .�. Aquatic Structures Division F�# 10818 - - Delaware Ave. Fort Pierce, FL 34950 1\ Jensen Beach, FL 00 0 ° w eo K ti d i7 riQ. n Q 10 rOQ o C) .s! _ j ALL, ��� or .., 00 ° drt o H* b� 03 a�� �y o All 00 v w bd O d O IZN '`r de- O Coco N e.. O 5 -. CC7 00 o o Fjy R IV 10 0 t �i 000-4 o F� 1" r O n n 7R - � S �1 S C 5 O - a � 1 1 • 00 o "� bd a \ \ VAR/ES —1— 36" TO 42" t rA � G s\tom: ti o O� rv) �p Z 4� ° L��t \ ) ti '` 1 ti V O vt I (� O NO n yy O a � rzi y � Lo pa rra1�5 O O #- J S OD 5 PILES 12' 0. C. MAX. - s EACH WAY _ Engineer's Certification for Wind Load Compliance Project Name: Island Dunes Street Address: 8735 South Ocean Drive, Jensen Beach, FL Construction Type: Dock/Boardwalk Bowdoin G. Hutchinson P.E. 806 Delaware Ave. Fort Pierce, FL 34950 certify that, to the best of my knowledge and belief, these plans and specifications have been designed to meet or exceed the applicable structural portion of the Building Codes currently adopted and enforced by Martin County. I also certify that structural elements depicted on these plans provide adequate resistance to the wind loads and forces specified by current code provisions. Design Parameters and Assumptions Used: 1 Florida Building Code 2017 Edition with N/A Supplements and ASCE 7-10 2. Building Design is: Enclosed: Partially Enclosed: Open Building: X 3. Mean Deck Height: 6'+ Roof Pitch: N/A Internal Pressure Coefficient: 0.0 4. Width of End Zone: 1' Wind Speed: 175 (3 sec. gust) 5. Building Classification Table 1-1. ASCE 7-10 FBC Table 1604.5 1 6. Wind Exposure Classification: D Adjustment Factor for Exposure & Height: 1.0 7. Components & Cladding Wind Pressure on Roof Zone 1 N/A 2 N/A 3 N/A _PSF 8. Components & Cladding Wind Pressure on Wall Zone 4 +60.6/-64.1 5 +70.1/-74.5 PSF 9. Components & Cladding wind Pressure on Overhead Garage Door N/A _PSF 10. Loads: Floor 40 PSF Roof/dead N/A PSF Roof/live N/A PSF 11. Shear Walls Considered for Structure? Yes X No (if No, attach explanation) 12. Continuous Load Path provided? Yes X No (if No, attach explanation) 13. Are Component and Cladding Details Provided? Yes X _ No (if No, attach explanation) 14. Minimum Soil Bearing Pressure: N/A _ Presumptive: N/A _ By Test: N/A _ PSF Engineer's Note: All Aqueous structures shall be designed for a minimum 170 MPH Min. wind load regardless of wind zone. As witnessed by my seal, I hereby certify that the information included with this certification is true and correct, to the best of my knowledge and belief. Name: Bowdoin G. Hutchinson Cert #: PE# 70878 Date: 6/9/2020