HomeMy WebLinkAboutWnuk GEN SPECS20/22 kW
INCLUDES:
: True Power'" Electrical Technology
* Two-line multilingual digital LCD Evolution" controller
(English/Spanish/French/Ponuguese)
• 200 amp service rated smart switch transfer switch available
• Electronic governor
• Standard Wi-Fi® connectivity
• System status & maintenance interval LED indicators
• Sound attenuated enclosure
0 Flexible fuel line connector
• Natural gas or LP gas operation
• 5 Year limited warranty
• Listed and labeled by the Southwest Research Institute allowing
installation as close as 18 in (457 mm) to a structure."
'Must be located away from doors, windows, and fresh air intakes and in
accordance with local codes.
https.l/assets.swri.orgllibrary/DirectoryONrstedProducts/
Constructionlndustryl973 DoI 204 13204-01-01 Rev9.pdf
FEATURES
O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Gen-
erac's success in providing the most reliable generators possible. Generac's G -
Force engine lineup offers added peace of mind and reliability for when it's needed
the most. The G -Force series engines are purpose built and designed to handle the
rigors of extended run times in high temperatures and extreme operating conditions.
O TRUE POWER'" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave
form produce less than 5% Total Harmonic Distortion for utility quality power. This
allows confident operation of sensitive electronic equipment and micro -chip based
appliances, such as variable speed HVAC systems.
O TEST CRITERIA:
✓ PROTOTYPE TESTED ✓ NEMA MG1-22 EVALUATION
✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY
O MOBILE LINK® CONNECTIVITY: FREE with select Guardian Series Home standby
generators, Mobile Link Wi-Fi allows users to monitor generator status from any-
where in the world using a smartphone, tablet, or PC. Easily access information such
as the current operating status and maintenance alerts. Users can connect an
account to an authorized service dealer for fast, friendly, and proactive service. With
Mobile Link, users are taken care of before the next power outage.
GENERAL®
GUARDIAN® SERIES
Residential Standby Generators
Air -Cooled Gas Engine
Standby Power Rating
G007038-1, G007039-1, G007038-3, G007039-3 (Aluminum - Bisque) - 20 kW 60 Hz
G007042-2, G007043-2, G0070423, G007043-3 (Aluminum - Bisque) - 22 kW 60 Hz
s or 4LISTED DS Qv I.c �� uu
Note: CETL or CUL certification only applies to unbundled units and units ppaackaged
with limited circuit switches. Units packaged with the Smart Switch are ETL or UL
certified in the USA only.
O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This
state-of-the-art power maximizing regulation system is standard on all Generac mod-
els. It provides optimized FAST RESPONSE to changing load conditions and MAXI-
MUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge
loads to the engine. Digital voltage regulation al ±1%.
O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network
provides parts and service know-how for the entire unit, from the engine to the small-
est electronic component.
O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with
GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC
product line is offered with its own transfer systems and controls for total system
compatibility.
�IPROMISE®@ '
Unit
• SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding
winds up to 150 mph (241 km/h). Hinged key locking roof panel for security. Lift -out front for easy access
to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability.
• Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
• Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18 in (457 mm) away from a structure.
ENERAC®
20/22 IOW
Features and Benefits
Engine
• Generac G-Force design
Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly
"Spiny-lok"
rings help the engine run cooler, reducing oil consumption and resulting in longer engine life.
• cast iron cylinder walls
Rigid construction and added durability provide long engine life.
• Electronic ignition/spark advance
These features combine to assure smooth, quick starting every time.
• Full pressure lubrication system
Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer engine
life. Now featuring up to a 2 year/200 hour oil change interval.
• Low oil pressure shutdown system
Shutdown protection prevents catastrophic engine damage due to low oil.
• High temperature shutdown
Prevents damage due to overheating.
Generator
• Revolving field
Allows fora smaller, lightweight unit that operates 25% more efficiently than a revolving armature generator.
• Skewed stator
Produces a smooth output waveform for compatibility with electronic equipment.
• Displaced phase excitation
Maximizes motor starting capability.
• Automatic voltage regulation
Regulating output voltage to ±1 % prevents damaging voltage spikes.
• UL 2200 listed
For your safety.
Transfer Switch (if applicable)
• Fully automatic
Transfers vital electrical loads to the energized source of power.
* NEMA 3R
Can be installed inside or outside for maximum flexibility.
• Remote mounting
Mounts near an existing distribution panel for simple, low-cost installation.
Evolution- Controls
■ AUTO/MANUAUOFF illuminated buttons
Selects the operating mode and provides easy, at-a-glance status indication in any condition.
• Two-line multilingual LCD display
Provides homeowners easily visible logs of history, maintenance, and events up to 50 occurrences.
• Sealed, raised buttons
Smooth, weather-resistant user interface for programming and operations.
• Utility voltage sensing
Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage.
• Generator voltage sensing
Constantly monitors generator voltage to verify the cleanest power delivered to the home.
• Utility interrupt delay
Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5
seconds by a qualified dealer.
• Engine warm-up
Verifies engine is ready to assume the load, setpoint approximately 5 seconds.
• Engine cool-down
Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
• Programmable exercise
Operates engine to prevent oil seal drying and damage between power outages by running the generator for
5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing
flexibility and potentially lower fuel costs to the owner.
• Smart battery charger
Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Compatible with lead acid and AGM-style batteries.
■ Main line circuit breaker
Protects generator from overload.
• Electronic governor
Maintains constant 60 Hz frequency.
Unit
• SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding
winds up to 150 mph (241 km/h). Hinged key locking roof panel for security. Lift -out front for easy access
to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability.
• Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
• Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18 in (457 mm) away from a structure.
GENERAC
20/22 kW Features and Benefits
Installation System
f 14 in (35.6 cm) flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply
piping.
• Integral sediment trap Meets IFGC and NFPA 54 installation requirements.
Connectivity (Wi-Fi equipped models only)
* Ability to view generator status Monitor generator with a smartphone, tablet, or computer at any time via the Mobile Link application for
complete peace of mind.
Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours.
* Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due.
• Monthly report with previous month's activity Detailed monthly reports provide historical generator information.
® Ability to view generator battery information Built in battery diagnostics displaying current state of the battery.
• Weather information Provides detailed local ambient weather conditions for generator location.
GENERA`
20/22 kW
Specifications
Generator
Model
G007038 -1,G007039-1 6007042-2,G007043-2 G007038 -3,G007039-3 G007042-3, G007043-3
(20 �)
iidtfi Con tiiui annumra I(
Rated maximum continuous power capacity (G
(22 kW) (20 kW) (22 �
kfiw i MUM* 208100 4�atts l MO-OfQ-k%-*
ve e
18,000 Watts' 19,500 Watts' 18,000Watts' 19,500 Watts'
Rated maximum continuous load current -240 volts (LP/NG)
`'f'tDi`d(T-�aEtlt4gci6Yfidh
24�
83.3/75.0 91.7/81.3 83.3/75.0 91.7/81.3
Main line circuitt breaker`
ER
90 amp 100 amp 90 amp 100 amp
Number of rotor poles
t
'gyp
2
Power factor
6
T Ire i` � }
Unit weight (Ib / kg)
10
1 iKR `f> UP KV, �I Gln iurir ar (�(iiip 35 � W6 CA Neff aai
mertslQns(Lx1NxH1_w c
448/203 466/211 436/198 445/202
Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load"
4�z'�"x`���i2i X79.7
e � .� V-6— exeI r
67 67 67 67
5 57
Exercise duration -
0 57
Engine -
5 min
Engine type
r
GENERAC G -Force 1000 Series
Displacement
2
999 cc
Valve arrangement
rte nrim oa r on eeve
—. ,
M
Overhead valve
Governor system
S6_Ff_o'_ w�rtfagneto
- n-iD
Electronic
Starter
M
c v[
12 VDC
Operating rpm
.19 of%4L
[Fue['rT,bdStrmoai
3,600
Natbralgas INAF, (irt3/hr)
1/2 Load
Full Lead
tLiquidpropans fha/ta (gat/hr) [flfxl
204 (5.7,i) 228 {6.467 1-64(4.64) 203 (5.75)
301(8.52) 327 (9.26) 287 (8.13) 306 (8.66)
1/2 Load
Fu(f Loaf)
Note: Fuel pipe must be sized for full load. Required fuel pressure to fuel inlet
87 (2.37) [8,99] 92 (2.53) [9.57] 86 (2.36) [8:95) 92 (253) [9.57]
130(3 *56) [13.48) 142 (3:90) [1437] 136 (3.74) [14.15] 142 (3.90) [14.77]
generator at all load ranges - 3.5-7 in water column (0.87-1.74 kPa) for NG, 10-12 in water column (2.49-2.99 kPa) for LP gas.
For BTU content, multiply ft3/hr x 2500 (LP) or ft%r x 1000 (NG). For Megajoule content, multiply m3/hr x 93.15 (LP) or m3/hr x 37.26 (NG).
Controls
Two-line plain text multilingual LCD
o q 0
Simple user interface for ease of operation
MANUAL'p,.
Aiddat tc slai('ao uk1 #arjure. Vee 3' ®Gwaeor Mont tebl
stae m rci r.
F
Start with stager control unit stays on. If utility fails, transfer to load takes place.
Ready to Run/Maintenance messages
fops�n Poweh iemaV C n rof acid charger s I npera(e.
";h me r1Plio�e r $on
Standard
Programmablleag deeia between 2-1500 seconds
Stannda d
ki!Ig'�e`ergit([tyed�feewifbutsettg)
Future Set
Standard (programmable by dealer only)
Frgm140.(fiji902isv
Capable Exerciser/Exercise Set Error warning
[#ura anrogs
Standard
Engine stag sequence
Mrfa oul
50 6nr ea6tj
pi
Cyclic cranking: 16 sec on 7 rest (90 sec maximum duration).
Smart Battery Charger
Staher canndt re-engage unts"5 sec atC„ fir e9 ftas�dpped,
Cher Fjssin AC wammg
Standard
"
Law Battery/Battery Problem Protection and Battery Condition indication
dd
a1 i olta u i[qn w Over and �(fhder`VitlaOe ProtecG0
Standard
Stan
Under-Frequency/Ovegoad/Stepper Overcurrent Protection
dose P efn" roii chars
Standard
Automatic Low Oil Pressur e/Hrgh'pg Temperature Shutdown
tandda_rd
i eii cion vt . 'fi2lfz m" rise ass
Standard
Si
High Engine Temperature Shutdown
ndaid
)ritema( Fau nc'orrecf�fA, -.fiction
Standard
Common external fault capab
mrdility
I'iel�i uPOradleirmwaog
Standard
Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation param�eteri. -Rating definitions - Standby: ing
emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, IS03046 and DIN6271). " Maximum
for nit
subject to ampsland
and limited by such factors as fuel BTU/megajoule content, ambient temperature, altitude, engine
level; and also will decrease approximately 1 % for each 10 °F (6'C) above 60'F (16 °C).
kilovolt cur eicabe
are
powerand condition, etc. Maximum power decreases approximately 3.5%foreach 1,000 ft (304.8 m) above sea
200 Amps 120/240,18
Open Transition Service Rated
Height Width
Hi H2 W1 W2 Depth
in 26.75 30.1 10.5 13.5 6.91
cm 67.95 76.45 26.67 34.29 17.55
Wire Ranges
Conductor Lug Neutral Lug Ground Lug
400 MCM - #4 350 MCM - #6 2/0 - 014 J
1- DEPTH -7 I--wz --I
GENERAC®
20/22 kW
Switch Options
Service Rated Smart Switch Features
Includes digital power management technology (DPM) standard.
Model
G007039-1 (20 kW)
0007043-2 (22 kW)
i Intelligently manages up to four air conditioner loads with no additional hardware.
G00703M (20 kW)
• Up to eight additional large (240 VAC) loads can be managed when used in
of
0007043-3 (22 kW)
conjunction with SmartManagement ModulesSMMs .
( )
Current rating (amps)
200
0 Electrically operated, mechanically-held contacts for fast, clean connections.
N )
W-2-40,
O-240,1_0
+� Rated for all classes of load, 100% equipment rated, both inductive and resistive.
Utility voltage monitor (fixed)'
• 2-pole, 250 VAC contactors.
-Pick-up
-Dropout65%
80%
Service equipment rated, dual coil design.
lk—.M Uftl*
_
r4 f3Sec
� Rated for both aluminum and copper conductors.
Exercises bi-weekly for 5 minutes'
r til. listed
Standard
• Main contacts are silver plated or silver alloy to resist welding and sticking.
Enclosure type
NEMA/UL 3R
0 NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting
L 'tbreaker ocerecteti
22,aW
flexibility.
Lug range
250 MCM - #6
*Function of Evolution controller
Dimensions
Exercise can be set to weekly or monthly
200 Amps 120/240,18
Open Transition Service Rated
Height Width
Hi H2 W1 W2 Depth
in 26.75 30.1 10.5 13.5 6.91
cm 67.95 76.45 26.67 34.29 17.55
Wire Ranges
Conductor Lug Neutral Lug Ground Lug
400 MCM - #4 350 MCM - #6 2/0 - 014 J
1- DEPTH -7 I--wz --I
20/22 kW
I mom # Product Rescripifun
G005819-0
G007101-0
G007102-0
G007103-1
G005621-0
GENERAC®
Available Accessories
26R Wet Cell Battery Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell battery
for use with all air-cooled standby product (excluding PowerPact®).
Battery Pad Warmer Pad warmer rests under the battery. Recommended for use if temperature regularly falls below 0 IF (-18 °C). (Not
necessary for use with AGM -style batteries).
Oil Warmer
Breather Warmer
Auxiliary Transfer Switch
Contact Kit
G007027-0 - Bisque Fascia Base Wrap Kit
(Standard on 22 kW)
Oil warmer slips directly over the oil filter. Recommended for use if temperature regularly falls below 0 IF (-18 °C)
Breather warmer is for use in extreme cold weather applications. For use with Evolution controllers only in climates
where heavy icing occurs.
The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not
be needed. Not compatible with 50 amp pre -wired switches.
I The fascia base wrap snaps together around the bottom of the new air-cooled generators. This offers a sleek, con-
toured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the
base.
G005703-0 - Bisque Touch -Up Paint Kit
If the generator enclosure is scratched or damaged, it is important to touch up the paint to protect from future corro-
6007038-1
sion. The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure.
G006485-0 Scheduled Maintenance Kit
Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a
6007039-1
Generac automatic standby generator (oil not included).
G007005-0 Wi-FI LP Tank Fuel Level
The Wi-F! enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank. Monitoring
Monitor
the LP tanks fuel level is an important step in verifying the generator is ready to run during an unexpected power failure.
G007042-3
Status alerts are available through a free application to notify users when the LP tank is in need of a refill.
G007000-0 (50 amp) Smart Management Module
Smart Management Modules (SMM) are used to optimize the performance of a standby generator. It manages large
G007006-0 (100
electrical loads upon startup and sheds them to aid in recovery when overloaded. In many cases, using SMM's can
amp)
reduce the overall size and cost of the system.
G007169-0 Mobile Link® Cellular
The Mobile Link family of Cellular Accessories allows users to monitor generator status from anywhere in the world,
Accessories
using a smart phone, tablet, or PC. Easily access information such as the current operating status and maintenance
alerts. Users can connect an account with an authorized service dealer for fast, friendly, and proactive service. With
Mobile Link, users are taken care of before the next power outage.
Model
UPC
6007038-1
696471074185
G007038-3
696471074185
6007039-1
696471074192
G007039-3
696471074192
G007042-2
696471074208
G007042-3
1 696471074208
6007043-2
696471074215
6007043-3
696471074215
GENERAC®
�z
[2
Dimensions & PCs
1— im
LEFT SIDE VIEW FRONT VIEW
Dimensions shown are approximate. See installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.
Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com
02020 Generac Power Systems, Inc. All rights reserved. All specifications are sublectto change without notice. Part No. A0000221268 Rev. B 05/28/2020