Loading...
HomeMy WebLinkAboutWnuk GEN LOAD CALCSLoad Calculation by: To: The Martin County Building Department Re: Load calculation for the Wnuk Residence Date: 6/30/2020 CRMO POWER 2,120 Sq. ft x 3 watts per square foot 6,360 Watts 2 Appliance circuits @ 1500 watts 3,000 Watts 2 Refrigerator circuits @ 1500 watts each 3,000 Watts 1 Laundry circuits @ 1500 watts 1,500 Watts 1 Dishwasher & Disposal 3,000 Watts 1 Microwave 1,200 Watts 1 Range/Oven _ 8,000 Watts _ 1 Air Handler #1 0 Watts�Shed 1 Air Compresor #1 0 Watts 1 GDO 1,600 Watts 1 Water Heater 4,500 Watts 1 Water Pump 0 Watts Shed 1 Dryer 5,000 Watts TOTAL EXISTING WATTS 39,160 Watts existing First 10000 watts @ 100% 10,000 Watts 29,160 (Existing watts - 10,000) Remainder @ 40% 11,664 Watts TOTAL GENERATOR LOAD 21,664 Watts/ 90.3 Sincerely Amps