HomeMy WebLinkAboutLetter; Post Tension CablesSt Lucle County Panning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, Florida 34952 772-462-1553 Re: 10410 South Ocean Drive Jensen Beach, Florida 34957 Dear Building Official: The existing structural slab on the address listed above is reinforced with post tension cables. Attachments to the slab can be made with the use of fasteners with a length of 3/4" or less. This will allow for fastener penetration that Is less than the minimum coverage requirements for post tension cables. As a result, there should be no conflict with the cables. Attachment to concrete or masonry shall be via power driven fasteners. Secure runners with fasteners located 2" from each end and spaced a maximum of 16" on center. Sincerely; J!• Al ��• j, 0�1 C*E NHS. .6 4i N0, 43855 r ":;e �15UtiJt�>v'•r�i.ai.,+l7i,+ -. m7c" `L sTATEOF- Roger M Babe'r """"" Florida Registered Professional Engineer#43855 MCR Professional Engineering, Inc. !^ ;• i kTA- REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY I30CC Page 1 of 1