Loading...
HomeMy WebLinkAbout002 Energy Calcs - Manual J - Layout - Chambers 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: CHAMBERS RESIDENCE Builder Name: COLE CONSTRUCTION SERVICES,LLC. Street: 4700 INDRIO ROAD Permit Office: ST LUCIE COUNTY City,State,Zip: FORT PIERCE,FL,34951 Permit Number: Y U Owner: ROSS AND NORANN CHAMBERS Jurisdiction: ST LUCIE COUNTY w Design Location: FL,Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA, General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit Ceiling/attic insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/door jambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation,insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring an J plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Concealed When required to be sealed,concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer.Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a.In addition,inspection of log walls shall be in accordance with the provisions of[CC-400. 7/30/2020 12:32 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 1 This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF. GENERAL SPECIFICATIONS: SHEET INDEX WINDOW/ LINTEL SCHEDULE DOOR/ LINTEL SCHEDULE i° p 1. ROOF: 5V METAL OVER 30#FELT OVER 5/8"CDX PLY OVER PE WOOD ROOF TRUSS AS PER FRAMING PLAN. A-1 floor plan ,o,+ � U = • D. 2.CEILING: 1/2"OR 5/8"GWB OVER WOOD PE TRUSS BOTTOM CHORD. un O �' o LINTELTE • • • • 3. E:XTERIOR SOFFIT: STUCCO&LATH PER GEN NOTE 34 OVER FRAMING W/NO VENTS. A-2 foundation plan = p • _. u T R PINE T&G PER GEN NOTE 34. o — U s? 4. PORCH CEILING: STUCCO& LATH OVER FRAMING O - m = 3fr , L7NTEG8RFZ2, S 1T„ .,, 6.,S1hffN ,.fiiLAZEG:,,_i., A 3 elevs N ;1' "_ ._ o W�n1:. .,: z�`r�-7i,��$.���,F n.t2).`3� ,i5-'.1,.. �`�� ,1, GG"11f±111-„�..�.• .�i , . . . ... . t. 5. INSULATION: R20 SPRAYFOAM @ CONDITINED ROOF DECK, &ATTIC SEPARATING KNEE WALLS @PORCHES&GARAGES. � „ � � � 1B/1T D.SWING,GLAZED o E •,,, R-13 BATT @GARAGE SEPARATING WALL, FLOOR TO CLG. PROVIDE ACCESS HATCH TO CONNECT ATTIC SPACES. A-4 elect/plumb plan "� ;' o � E .a W2 35.7,-38.7 6-3 8 9 8-0 CC LINTEL 8F24-1B/1T TRIP FIXED W/ARCH OWNER SUPPLIED a D2 34.1 36 1 6 0 8-0 CC LINTEL SRF22 , V k „ ..,. ,a,. .,,. , . � , ,a„L .. 61 N EL.BNtl:22.1 _ :, S.SWING � EI}� , . r .,_.... MITT P DUCT LAYOUT Q o ,.. ,.,.. ... .��p.,. ., ,.. .,i,.,,,.,,,.,, , ,,.;, ,..,. .:. D3 34'1 3 ...2.-$,:,, ,$•fl.. .CC,U...T ..,.�/, ,,, .r.,. . , „ ...,.. ^, .R ._, . .. ,... ., 6. DEFFERED SUBMITTALS: ROOF TRUSSES, SITE LAN, - ��P$�,k �,�,I de;.C{r�U��e�r$Pw .K%. ., fi�r.��4UN�v s.mw,2,d: v.l,., ,.1EE�S,.., ,,,,u F, I„kua r-..,, ,w ... . -,. _ r _-; 4- „ �° GN 1 general notes + iE Co � m W4 357 387 28 52 8-0 CC LINTEL8F2418/1T SHUNG EGRESS D4 341 361 9-0 8-0 CC LINTEL8F2418/2T SECTIONAL OVERHEAD ,^ C � M ��/ 3 3S 9-0,-;' E . CG�INTEL�3�2416/27.,,. � '}5EGIIONALO i,v ,�,5�i, 3'a'7„�9;77/:.,1 42,, "4.r :, 3,- .Ir�r..1+ +F`�,'E.,17.^�'tr;tirnr24-.�. �'.. 4 �t , x l;5, „L< :,.�i , rv . ,. •, !. �.,, D `�. ..a..,,-. k>,...... .. < a., __�-... , _ — W6 35.7,-38.7 4-4 6-3 8-0 CC LINTEL8F24-1B/1T FIXED OWNER SUPPLIED D6 31.3,-35.5 2-6 8-0 CC LINTEL8RF22-1B/1T S.SWING,GLAZED a lh ti n W W,7,l,,r;a3IX",3$�3„',,,i ,,NlimGdi+lr" t,'.it 'r.vCCL;1NFEL-$ 7416fi,,, ,t FGXEDr- r,,, ),I, „'' OU/t�Eft.SUPPLIEd), ? SEE GEN NOTE 26. CC:CAST CRETE pg cl1 � W8 35 7 38 7 4-4 6 3 8-0 CC LINTEL 8F24 1B/1T FIXED OWNER SUPPLIED O co co LL_ PROJECT DESCRIPTION J U z 78 �� DOUR AREA CALCULATIONS: 38 7 (2)4-0 5 2 8 0 CC LINTEL 8F24 1B/1T S HUNG NEW CONSTRUCTION OF A 1 STORY SF W10 35 7 conditioned living area 3,436 sf RESIDENCE ON A VACANT LOT. EEL :,2 2�;.P�,,rD,ti I,'I §? nh'� R,t , it �.� .;� 011!/NER,SI�PIIfA�� W12 35 7 8.7 5-4 5-4 8 0 CC LINTEL 8F24-1B/1T GLASS BLOCK garage 576 sf ZONING INFORMATION: 3, • . '.* S 2. ,'it�I_a" s`COUAITBs�_. ,. .E!U :� !�;k , ,•..,,-ELfE?S. ., ., .?! C• covered rear porch 738 sf parcel id: 1418-133-0040-000-7 covered front porch 266 sf AR-1 (unincorporated St Lucie County) W14 35.7,47.7 3-0 5-2 8-0 CC LINTEL8F24-1B/1T IS.HUNG ITEMP total building area 5,076 sf flood zone:X SEE GEN NOTE 26. CC:CAST CRETE conditioned volume 34,360 cf UTILITY INFORMATION: gas: n/a sewage: septic w potable water public a 61 LL_ U W 12'-51/2" • - �" 8'-11" 2'-9" r o 3 o w O SLOPE AS PER ELEVATIONS o I ¢ 0 �qCL I ROOF/UNDERLAYMENT/SHEATHING AS PER GENERAL SPECS W o w J 13'-8 1/ 6'-10" 8'4" '1 PE TRUSS AS PER FRAMING PLANS- w \\ � i INSULATION AS PER GENERAL SPECSLo , Q} N^ LU BR.3 SK i� SEE FRAMING PLANS OR CONNECTOR SCHEDULE W o 4 _ u — BR.2 I SEE E ELEVS 7 ' Y i [� \ CL N METAL DRIP OVER PT WOOD DRIP OVER ' r' W U a w n CLG AS PER GENERAL SPECS&FLOOR PLAN ® o 1l z r7 ®® n V J 12 10" I Zx8 CEDAR FASC16d TRUSS ENDS W/(2) 2 � !; (�� m 13'-8 1/ -4" 6'-1 #16d NAIL,5"TRUSS HEEL 2 8x 24x8A ( REF AS PER GENERALI& �+ MASONRY BOND MASONRY BOND B S2 di ,;.„ •7;,;.+�,,. , I EXTERIOR SOFFIT AS PER GENERAL SPECS SPECS 0 o i N da G- N ( SVERT REBTUCCO IAR @ 48DOC,CONTO BOND BEAM TOP 2VER 8x8x16 CMU /) I I � w - - - - COURSES W/#5 REBAR EA COURSE-51 OR 1/2"GWB '� a - - - - - - - - OVER R4.1 FOIL INSULATION OVER 314"FURRING STRIP. W N a LI_ w x WALL REINF AS PER GENERAL SPECS- O m I m SPLICING AS PER GENERAL NOTES "L SOG/FILUCOMPCTION AS PER w FOUNDATON PLAN AND L I I 8"x8"THICKNED EDGE W/(1)CONT#5 GENERAL NOTES O � N W W � f z s cIg.10'-0"typ LIVING � i fV z I o- STEM WALL:8x8x16 CMU W/#5 VERT z I o REBAR @ 48"OC w REAR PORCH T-8" i GRADE AS PER SITE PLAN 0 I 3 r y Z_ Fit I I ; FRONT _ I z 24" .. . c1 I PORCH —� dg.12.-0., o N TYP WALL SECTION o (O � D2 J z ? I SCALE:V2"=1'-0" � I o I I I 3 2'-1 4' 10, ' c1g.11• n I SK O O 9 D3 2-8xe-0 I I DINING o 0 4 I- �rJ_ KI CHEN dg.11-o" x x o CLST � tyb � � ro O izOL 1 - - - - - -I U 4-0x8-0 WALL LEGEND THICKNESS m CLST ON FLOOR � � Q ID DESORPTION SPECS PLAN -"�.'� N 5'S" R. REINFORCED CMU WALL - W/FINISHES SEE TYP WALL SETCTION 9 Pam ' ( j REINFORCED CMU WALL floor Ian s'-11 yr � GA. GE GARAGE W/O INT FINISH SEE TYP WALL SETCTION S. p 6'-41/2" 3' i : Q RA IE REINFORCED CMU COLUMN SEE FLOOR PLAN VARIES 9i\J 7/26/20 1 i(�r��� � NON LOAD BEARING INT WALL SEE GENERAL SPECS ON A-1 4.5" SHEET 2-4x8-O WEIR A MBA " LOAD BEARING 4 WALL BR WALL DETAIL 4.5" r' - - - oEc il O B G2x SEE G E A DEN - - - - - - - - - - - a - - - - - - - - - - - a � SK 24x8-0 C T C$ N BA.M ' F LST SWR 17'-4" 6'4 1!2" T T- 4" '�' 13'-9 112" 4'-71l2" 3' /11'-$3/4" \ / 111314"\ FLOOR PLAN NOTES: D6 DS D4 1.INTERIOR DIMENSIONS ARE TO FINISH W 4 W 3 W 2 W 1 W 0 m 2.EXTERIOR DIMENSIONS ARE TO STRUCTURE �� F'F��R 4_3^ 10'-4" Ic; 20'-73/4' T-61/2" , r-�" 10'-111/4" ;� 13'-91l4" 3'-61/2" 9' 2' 9' 2'-4' FLOOR PLAN KEYNOTES: -' NClS P.ClFe '9 1.22"x30"RO MIN ATTICACCESS •», ,, �. 931 " 2.DRIVEWAY PER SITE PLAN TO SERVE AS LANDING. 3.TYP PORCH COLUMN:12"x12"x8"CMU,4#5 VERT. o AR97108 4.TYP FRONT PORCH LINTEL:CASTCRETE 8F24-16/1T.12'TOB. �,FLOOR PLAN 5.TYP REAR PORCH LINTEL:CASTCRETE 8F16-1 B/2T.10'TOB. 'sTFRED,ARG�� SCALE: 114"=T-O" FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: CHAMBERS RESIDENCE Builder Name: COLE CONSTRUCTION SERVICES,LLC. Street: 4700 INDRIO ROAD Permit Office: ST LUCIE COUNTY City,State,Zip: FORT PIERCE,FL,34951 Permit Number: Owner: ROSS AND NORANN CHAMBERS Jurisdiction: ST LUCIE COUNTY Design Location: FL,Fort Pierce County: St.Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types (2574.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 2358.00 ft2 b.Frame-Wood,Adjacent R=13.0 216.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (3436.0 sqft.) Insulation Area a.Roof Deck(Unvented) R=20.0 3436.00 ft2 6. Conditioned floor area above grade(ft2) 3436 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(469.3 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 150 a. U-Factor: Sgl,U=0.32 136.33 ft2 b.Sup: Attic,Ret:Attic,AH:Attic 6 130 SHGC: SHGC=0.22 b. U-Factor: Sgl,U=0.34 84.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.22 a.Central Unit 35.2 SEER:16.00 b.Central Unit 24.0 SEER:16.00 c. U-Factor: Sgl,U=0.30 78.00 ft2 SHGC: SHGC=0.24 13.Heating systems kBtu/hr Efficiency d. U-Factor: other(see details) 171.00 ft2 a.Electric Strip Heat 27.0 COP:1.00 SHGC: other(see details) b.Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 8.452 ft. Area Weighted Average SHGC: 0.230 14.Hot water systems 8. Floor Types (3436.0 sqft.) Insulation Area a.Electric Cap:50 gallons EF:0.980 a.Slab-On-Grade Edge Insulation R=0.0 3436.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits None Glass/Floor Area: 0.137 Total Proposed Modified Loads: 97.23 PASS Total Baseline Loads: 98.48 1 hereby certify that the plans and specifications covered by Review of the plans and COD ME this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance • .Q with the Florida Energy Code. " G PREPARED BY: Before construction is completed DATE: 7-31-20 this building will be inspected for 10 compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. j+ with the Florida Energy Code. OE�NE2�'�y� OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). 7/30/2020 12:31 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: CHAMBERS RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 3436 Lot# Owner Name: ROSS AND NORANN CHAM Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: COLE CONSTRUCTION SER Rotate Angle: 0 Street: 4700 INDRIO ROAD Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St.Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City,State,Zip: FORT PIERCE, Family Type: Single-family FL, 34951 New/Existing: New(From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL VERO BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU 1 2061 18549 2 AHU 2 1375 12375 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 3 210 1890 No 0 1 1 Yes Yes Yes 2 WIC 3 49 441 No 0 1 Yes Yes Yes 3 BATH 3 56 504 No 0 1 No Yes Yes 4 BATH 2 56 504 No 0 1 Yes Yes Yes 5 BEDROOM 2 247 2223 No 0 1 1 Yes Yes Yes 6 HALL 57 513 No 0 1 Yes Yes Yes 7 FOYER 80 720 No 0 1 Yes Yes Yes 8 PANTRY 96 864 No 0 1 Yes Yes Yes 9 LIVING 448 4032 No 0 1 Yes Yes Yes 10 WIC 56 504 No 0 1 Yes Yes Yes 11 WIC 2 49 441 No 0 1 No Yes Yes 12 KITCHEN 304 2736 Yes 0 1 No Yes Yes 13 DINING 353 3177 No 0 1 Yes Yes Yes 14 MASTER BEDROO 410 3690 No 0 1 1 Yes Yes Yes 15 M WIC 1 105 945 No 0 1 Yes Yes Yes 16 M WIC 2 42 378 No 0 1 Yes Yes Yes 17 M BATH 229 2061 No 0 1 Yes Yes Yes 18 M TOILET 28 252 No 0 1 No Yes Yes 19 HALLWAY 60 540 No 0 1 No Yes Yes 20 DEN 258 2322 No 0 1 Yes Yes Yes 21 DEN CLST 27 243 No 0 1 No Yes Yes 7/30/2020 12:31 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 22 BATH 4 50 450 No 0 1 Yes Yes Yes 23 UTILITY 166 1494 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulation BEDROOM 3 37 ft 0 210 ft2 ---- 1 0 0 2 Slab-On-Grade Edge Insulation WIC 3 7 ft 0 49 ft2 ---- 1 0 0 3 Slab-On-Grade Edge Insulation BATH 3 1 ft 0 56 ft2 --_- 1 0 0 4 Slab-On-Grade Edge Insulation BATH 2 8 ft 0 56 ft2 ---- 1 0 0 5 Slab-On-Grade Edge Insulation BEDROOM 2 31 ft 0 247 ft2 ---- 1 0 0 6 Slab-On-Grade Edge Insulation HALL 3 ft 0 57 ft2 ---- 1 0 0 7 Slab-On-Grade Edge Insulation FOYER loft 0 80 ft2 --_- 1 0 0 8 Slab-On-Grade Edge Insulation PANTRY 12 ft 0 96 ft2 ---- 1 0 0 9 Slab-On-Grade Edge Insulation LIVING 22 ft 0 448 ft2 ---- 1 0 0 10SIab-On-Grade Edge Insulation WIC 7 ft 0 56 ft2 ---- 1 0 0 11SIab-On-Grade Edge Insulation WIC 2 1 ft 0 49 ft2 ---- 1 0 0 12SIab-On-Grade Edge Insulation KITCHEN 1 ft 0 304 ft2 ---- 1 0 0 13Slab-On-Grade Edge Insulation DINING 19 ft 0 353 ft2 ---- 1 0 0 14SIab-On-Grade Edge Insulation MASTER BEDRO 45 ft 0 410 ft2 ---- 1 0 0 15SIab-On-Grade Edge Insulation M W IC 1 7 ft 0 105 ft2 ---- 1 0 0 16SIab-On-Grade Edge Insulation M W IC 2 6 ft 0 42 ft2 ---- 1 0 0 17Slab-On-Grade Edge Insulation M BATH 15 ft 0 229 ft2 ---- 1 0 0 18SIab-On-Grade Edge Insulation M TOILET 1 ft 0 28 ft2 ---- 1 0 0 19SIab-On-Grade Edge Insulation HALLWAY 1 ft 0 60 ft2 ---- 1 0 0 20SIab-On-Grade Edge Insulation DEN 15 ft 0 258 ft2 ---- 1 0 0 21SIab-On-Grade Edge Insulation DEN CLST 1 ft 0 27 ft2 ---- 1 0 0 22SIab-On-Grade Edge Insulation BATH 4 5 ft 0 50 ft2 ---- 1 0 0 23SIab-On-Grade Edge Insulation UTILITY 13 ft 0 166 ft2 --_- 1 0 0 7/30/2020 12:31 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 3843 ft2 0 ft2 Light N 0.2 No 0.9 No 20 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 3436 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Unvented) BEDROOM 3 0 Blown 210 ft2 0.1 Wood 2 Under Attic(Unvented) WIC 3 0 Blown 49 ft2 0.1 Wood 3 Under Attic(Unvented) BATH 3 0 Blown 56 ft2 0.1 Wood 4 Under Attic(Unvented) BATH 2 0 Blown 56 ft2 0.1 Wood 5 Under Attic(Unvented) BEDROOM 2 0 Blown 247 ft2 0.1 Wood 6 Under Attic(Unvented) HALL 0 Blown 57 ft2 0.1 Wood 7 Under Attic(Unvented) FOYER 0 Blown 80 ft2 0.1 Wood 8 Under Attic(Unvented) PANTRY 0 Blown 96 ft2 0.1 Wood 9 Under Attic(Unvented) LIVING 0 Blown 448 ft2 0.1 Wood 10 Under Attic(Unvented) WIC 0 Blown 56 ft2 0.1 Wood 11 Under Attic(Unvented) WIC 2 0 Blown 49 ft2 0.1 Wood 12 Under Attic(Unvented) KITCHEN 0 Blown 304 ft2 0.1 Wood 13 Under Attic(Unvented) DINING 0 Blown 353 ft2 0.1 Wood 14 Under Attic(Unvented) MASTER BEDRO 0 Blown 410 ft2 0.1 Wood 15 Under Attic(Unvented) M W IC 1 0 Blown 105 ft2 0.1 Wood 16 Under Attic(Unvented) M W IC 2 0 Blown 42 ft2 0.1 Wood 17 Under Attic(Unvented) M BATH 0 Blown 229 ft2 0.1 Wood 18 Under Attic(Unvented) M TOILET 0 Blown 28 ft2 0.1 Wood 19 Under Attic(Unvented) HALLWAY 0 Blown 60 ft2 0.1 Wood 20 Under Attic(Unvented) DEN 0 Blown 258 ft2 0.1 Wood 21 Under Attic(Unvented) DEN CLST 0 Blown 27 ft2 0.1 Wood 22 Under Attic(Unvented) BATH 4 0 Blown 50 ft2 0.1 Wood 23 Under Attic(Unvented) UTILITY 0 Blown 166 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below o 1 N Exterior Concrete Block-Int InsuBEDROOM 3 4.1 15 0 9 0 135.0 ft2 0 0 0.2 0 2 S Exterior Concrete Block-Int InsuBEDROOM 3 4.1 8 0 9 0 72.0 ft2 0 0 0.2 0 3 W Exterior Concrete Block-Int InsuBEDROOM 3 4.1 14 0 9 0 126.0 ft2 0 0 0.2 0 4 N Exterior Concrete Block-Int Insul WIC 3 4.1 7 0 9 0 63.0 ft2 0 0 0.2 0 5 N Exterior Concrete Block-Int Insul BATH 2 4.1 8 0 9 0 72.0 ft2 0 0 0.2 0 6 N Exterior Concrete Block-Int InsuBEDROOM 2 4.1 14 0 9 0 126.0 ft2 0 0 0.2 0 7/30/2020 12:31 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Belowo To Wall Type 7 E Exterior Concrete Block-Int InsuBEDROOM 2 4.1 17 0 9 0 153.0 ft2 0 0 0.2 0 8 W Exterior Concrete Block-Int Insul HALL 4.1 3 0 9 0 27.0 ft2 0 0 0.2 0 9 W Exterior Concrete Block-Int Insul FOYER 4.1 10 0 9 0 90.0 ft2 0 0 0.2 0 10 W Exterior Concrete Block-Int Insul PANTRY 4.1 12 0 9 0 108.0 ft2 0 0 0.2 0 11 N Exterior Concrete Block-Int Insul LIVING 4.1 6 0 9 0 54.0 ft2 0 0 0.2 0 12 E Exterior Concrete Block-Int Insul LIVING 4.1 16 0 9 0 144.0 ft2 0 0 0.2 0 13 W Exterior Concrete Block-Int Insul WIC 4.1 7 0 9 0 63.0 ft2 0 0 0.2 0 14 N Exterior Concrete Block-Int Insul DINING 4.1 11 0 9 0 99.0 ft2 0 0 0.2 0 15 E Exterior Concrete Block-Int Insul DINING 4.1 8 0 9 0 72.0 ft2 0 0 0.2 0 16 N Exterior Concrete Block-Int InsuMASTER BE 4.1 8 0 9 0 72.0 ft2 0 0 0.2 0 17 S Exterior Concrete Block-Int InsuMASTER BE 4.1 18 0 9 0 162.0 ft2 0 0 0.2 0 18 W Exterior Concrete Block-Int InsuMASTER BE 4.1 19 0 9 0 171.0 ft2 0 0 0.2 0 19 S Exterior Concrete Block-Int Insul M W IC 1 4.1 7 0 9 0 63.0 ft2 0 0 0.2 0 20 S Exterior Concrete Block-Int Insul M W IC 2 4.1 6 0 9 0 54.0 ft2 0 0 0.2 0 21 S Exterior Concrete Block-Int Insul M BATH 4.1 15 0 9 0 135.0 ft2 0 0 0.2 0 22 S Exterior Concrete Block-Int Insul DEN 4.1 15 0 9 0 135.0 ft2 0 0 0.2 0 23 S Exterior Concrete Block-Int Insul BATH 4 4.1 5 0 9 0 45.0 ft2 0 0 0.2 0 24 N Exterior Concrete Block-Int Insul UTILITY 4.1 9 0 9 0 81.0 ft2 0 0 0.2 0 25 S Exterior Concrete Block-Int Insul UTILITY 4.1 4 0 9 0 36.0 ft2 0 0 0.2 0 26 E Garage Frame-Wood UTILITY 13 24 0 9 0 216.0 ft2 0 0.1 0.2 0 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Single Yes 0.32 0.22 Y 15.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 W 3 Vinyl Low-E Single Yes 0.3 0.24 Y 54.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 3 N 6 Vinyl Low-E Single Yes 0.32 0.22 Y 30.0 ft2 2 ft 0 in 1 ft 4 in None None 4 W 9 Vinyl Low-E Single Yes 0.65 0.22 Y 48.0 ft2 10 ft 0 in 1 ft 4 in None None 5 E 12 Vinyl Low-E Single Yes 0.31 0.24 Y 18.0 ft2 20 ft 0 in 1 ft 4 in None None 6 E 12 Vinyl Low-E Single Yes 0.34 0.22 Y 48.0 ft2 20 ft 0 in 1 ft 4 in None None 7 N 14 Vinyl Low-E Single Yes 0.65 0.25 Y 48.0 ft2 20 ft 0 in 1 ft 4 in None None 8 E 15 Vinyl Low-E Single Yes 0.3 0.24 Y 24.0 ft2 20 ft 0 in 1 ft 4 in None None 9 S 17 Vinyl Low-E Single Yes 0.32 0.22 Y 30.0 ft2 2 ft 0 in 1 ft 4 in None None 10 W 18 Vinyl Low-E Single Yes 0.34 0.22 Y 36.0 ft2 2 ft 0 in 1 ft 4 in None None 11 S 21 Vinyl Low-E Single Yes 0.31 0.24 Y 12.0 ft2 2 ft 0 in 1 ft 4 in None None 12 S 21 Vinyl Low-E Single Yes 0.31 0.24 Y 25.0 ft2 2 ft 0 in 1 ft 4 in None None 13 S 22 Vinyl Low-E Single Yes 0.32 0.22 Y 40.0 ft2 2 ft 0 in 1 ft 4 in None None 14 N 24 Vinyl Low-E Single Yes 0.32 0.22 Y 21.3 ft2 2 ft 0 in 1 ft 4 in None None 15 S 25 Vinyl Low-E Single Yes 0.65 0.25 Y 20.0 ft2 10 ft 0 in 1 ft 4 in None None 7/30/2020 12:31 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 5 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 576 ft2 576 ft2 24 ft 9 ft 13 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 W holehouse Proposed ACH(50) .0004 3607.8 198.06 372.49 .1454 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 2 Electric Strip Heat/ None COP:1 17 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 35.2 kBtu/hr 1056 cfm 0.8 1 sys#1 2 Central Unit/ Split Single SEER: 16 24 kBtu/hr 720 cfm 0.8 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None UTILITY 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# v # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 150 ft2 Attic 15 ft2 Default Leakage Attic (Default)c(Default)c 1 1 2 Attic 6 130 ft2 Attic 13 ft2 Default Leakage Attic (Default)c(Default)c 2 2 7/30/2020 12:31 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: N Ceiling Fans: rjCooling Jan Feb Mar Apr I May Jun Nov Dec VentinHeating H Jan H Feb X Mar A Jan Feb Mar pr May Jun rj Jul rj Aug �Xj Sep �A Oct Nov Dec Oct Oct xJ Nov Dec Jun Jul Aug Sep Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 PANTRY Default(8 Ibs/sq.ft. ft2 ft 0.3 LIVING Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 DINING Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 M TOILET Default(8 Ibs/sq.ft. ft2 ft 0.3 HALLWAY Default(8 Ibs/sq.ft. ft2 ft 0.3 DEN Default(8 Ibs/sq.ft. ft2 ft 0.3 DEN CLST Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 UTILITY 7/30/2020 12:31 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 7 of 7 This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF. 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New(From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple-family 2. Single-family b) Return ducts R 6.0 c)AHU location Attic 3. No. of units (if multiple-family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 59.2 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b)Single package SEER c)Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 3436 d) Room unit/PTAC EER e)Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.401 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.230 14. Heating system: Capacity 44.0 c)Area 7c. 469.3 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient(SHGC) 8b. NA e) Gas furnace, LPG AFUE f)Other 9. Floor type, insulation level: a) Slab-on-grade(R-value) 9a. 0.0 b)Wood, raised (R-value) 9b. 15. Water heating system c)Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame(Insulation R-value) 10B1. 13.0 2. Masonry(Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 1 la. 0.0 b) Cross ventilation No b) Single assembly 11 b. c)Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: 4700 INDRIO ROAD City/FL Zip: FORT PIERCE, FL 34951 7/30/2020 12:32:24 PM EnergyGauge®USA 6.0.04(Rev. 1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF. MIJ�.� N� t*,a alo1 rr Project SummaryJob: Date: Jul 30,2020 AHU 1 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM Project • • For: CHAMBERS RESIDENCE, COLE CONSTRUCTION SERVICES, LLC. 4700 INDRIO ROAD, FORT PIERCE, FL 34951 Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 °F Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 28 °F Design TD 15 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18878 Btuh Structure 17899 Btuh Ducts 6031 Btuh Ducts 8635 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 24909 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipmenf sensible load 25207 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3423 Btuh Ducts 2381 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area (ft2) 2061 2061 Equipment latent load 5804 Btuh Volume (ft3) 18549 18549 Air changes/hour 0.28 0.15 Equipment Total Load (Sen+Lat) 31011 Btuh Equiv.AVF (cfm) 86 46 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR6036J 1 AHRI ref Coil TEM4AOC37S31++TDR AHRI ref 201763705 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 6.5 kW Sensible cooling 24640 Btuh Heating output 22349 Btuh Latent cooling 10560 Btuh Temperature rise 17 °F Total cooling 35200 Btuh Actual air flow 1173 cfm Actual air flow 1173 cfm Air flow factor 0.047 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.82 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. nn��lN�zoM® 2020-Jul-30 11:52:19 ,qcCd � Right-SuiteO Universal 2019 19.0.08 RSU08101 Page 1 `� ...ocumnets\Wrightsoft HVAC\CHAMBERS RESIDENCE.rup Calc=MJ8 Front Door faces: S g MIJ�.� N� t*,a alo1 rr Project SummaryJob: Date: Jul 30,2020 AHU 2 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM Project • • For: CHAMBERS RESIDENCE, COLE CONSTRUCTION SERVICES, LLC. 4700 INDRIO ROAD, FORT PIERCE, FL 34951 Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 °F Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 28 °F Design TD 15 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 12741 Btuh Structure 12770 Btuh Ducts 3132 Btuh Ducts 4543 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 15873 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipmenf sensible load 16447 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3307 Btuh Ducts 1211 Btuh Central vent (0 cfm) 0 Btuh Heating Coolingg (none) Area (ft2) 1375 1375 Equipment latent load 4518 Btuh Volume (ft3) 12375 12375 Air changes/hour 0.28 0.15 Equipment Total Load (Sen+Lat) 20965 Btuh Equiv.AVF (cfm) 58 31 Req. total capacity at 0.70 SHR 2.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR40251-1 AHRI ref Coil TEM6AOB24H21++TDR AHRI ref 7567540 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 4.2 kW Sensible cooling 16800 Btuh Heating output 14376 Btuh Latent cooling 7200 Btuh Temperature rise 16 °F Total cooling 24000 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.050 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.79 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. nn��lN�zoM® 2020-Jul-30 11:52:19 ,qcCd � Right-SuiteO Universal 2019 19.0.08 RSU08101 Page 2 `� ...ocumnets\Wrightsoft HVAC\CHAMBERS RESIDENCE.rup Calc=MJ8 Front Door faces: S g nn�.iaN�eo Right-J®Worksheet Job: AHU 1 Date: Jul 30,2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name AHU 1 BEDROOM 3 2 Exposed wall 156.0 ft 37.0 ft 3 Room height 9.0 ft 9.0 ft heat/cool 4 Room dimensions 15.0 x 14.0 ft 5 Room area 2061.0 ft2 210.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 n 4.00 2.19 549 456 1826 998 135 120 480 263 2 glazing,clr low-e 0.320 n 8.96 9.41 30 0 269 282 0 0 0 0 2 glazing,clr low-e 0.320 n 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 n 8.96 9.41 48 0 430 452 0 0 0 0 11 2 glazing,clr low-e 0.320 n 8.96 6.00 15 0 134 90 15 0 134 90 V�/ 13A-40cs 0.143 e 4.00 2.19 369 279 1117 610 0 0 0 0 I; GCI 2 glazing,clr low-e 0.320 a 8.96 24.95 18 1 161 449 0 0 0 0 2 glazing,clr low-e 0.320 a 8.96 24.95 72 4 645 1796 0 0 0 0 13A40cs 0,143 s 4.00 2.19 72 72 288 158 72 72 288 158 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 W 13A-40cs 0,143 w 4.00 2.19 414 312 1249 683 126 72 288 158 I;; GCCII 2 glazing,clr low-e 0.320 w 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 w 8.96 25.20 48 2 430 1209 0 0 0 0 2 glazing,clr low-e 0.320 w 8.96 14.69 54 2 484 793 54 2 484 793 C 16X19-0md 0.408 1.59 1.37 2061 2061 3268 2820 210 210 333 287 F 22A-tph 1,358 38.02 0.00 2061 156 5932 0 210 37 1407 0 6 c)AED excursion 0 374 Envelope loss/gain 16234 10340 3415 2123 12 a) Infiltration 2644 759 627 180 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 6800 0 Subtotal(lines 6 to 13) 18878 17899 4042 2303 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 62 24 14 Subtotal 18878 17899 4104 2327 15 Duct loads 32% 48% 6031 8635 32% 48% 1311 1122 FFTotal room load 24909 26534 5416 3449 Air required(cfm) 1173 1173 255 152 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. --4cCb, 2020-Jul-30 11:52:19 Right-Suite®Universal 2019 19.0.08 RSU08101 Page 1 ...ocumnets\Wrightsoft HVAC\CHAMBERS RESIDENCE.rup Calc=MJ8 Front Door faces: S nn�.iaN�eo Right-J®Worksheet Job: AHU 1 Date: Jul 30,2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name WIC 3 BATH 3 2 Exposed wall 7.0 ft 0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 7.0 x 7.0 ft 8.0 x 7.0 ft 5 Room area 49.0 ft2 56.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 n 4.00 2.19 63 63 252 138 0 0 0 0 2 glazing,clr low-e 0.320 n 8.96 9.41 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 n 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 n 8.96 9.41 0 0 0 0 0 0 0 0 11 2 glazing,clr low-e 0.320 n 8.96 6.00 0 0 0 0 0 0 0 0 V�/ 13A-40cs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0 I; GCI 2 glazing,clr low-e 0.320 a 8.96 24.95 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 a 8.96 24.95 0 0 0 0 0 0 0 0 13A40cs 0,143 s 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 W 2 glazing, 0.320 w 4.00 2.00 0 0 0 0 0 0 0 0 I;; GCCII 2 glazing,clr low-e 0.320 w 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 w 8.96 25.20 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 w 8.96 14.69 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 49 49 78 67 56 56 89 77 F 22A-tph 1,358 38.02 0.00 49 7 266 0 56 0 0 0 6 c)AED excursion -17 -26 Envelope loss/gain 596 188 89 51 12 a) Infiltration 119 34 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 300 Subtotal(lines 6 to 13) 715 222 89 351 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 71 28 14 Subtotal 715 222 160 378 15 Duct loads 32% 48% 228 107 32% 48% 51 182 Total room load 943 330 211 560 Air required(cfm) 44 15 10 25 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. --4cCb, 2020-Jul-30 11:52:19 Right-Suite®Universal 2019 19.0.08 RSU08101 Page 2 ...ocumnets\Wrightsoft HVAC\CHAMBERS RESIDENCE.rup Calc=MJ8 Front Door faces: S nn�.iaN�eo Right-J®Worksheet Job: AHU 1 Date: Jul 30,2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name BATH 2 BEDROOM 2 2 Exposed wall 8.0 ft 31.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 8.0 x 7.0 ft 1.0 x 247.0 ft 5 Room area 56.0 ft2 247.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-40cs 0.143 n 4.00 2.19 72 72 288 158 126 96 384 210 2 glazing,clr low-e 0.320 n 8.96 9.41 0 0 0 0 30 0 269 282 2 glazing,clr low-e 0.320 n 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 n 8.96 9.41 0 0 0 0 0 0 0 0 1 1 2 glazing,clr low-e 0.320 n 8.96 6.00 0 0 0 0 0 0 0 0 V)/ 13A-40cs 0.143 e 4.00 2.19 0 0 0 0 153 153 613 335 I; GCI 2 glazing,clr low-e 0.320 a 8.96 24.95 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 a 8.96 24.95 0 0 0 0 0 0 0 0 13A40cs 0,143 s 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 W 2 glazing, 0.320 w 4.00 2.00 0 0 0 0 0 0 0 0 I;; GCCII 2 glazing,clr low-e 0.320 w 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 w 8.96 25.20 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 w 8.96 14.69 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 56 56 89 77 247 247 392 338 F 22A-tph 1,358 38.02 0.00 56 8 304 0 247 31 1179 0 6 c)AED excursion 40 -112 Envelope loss/gain 681 194 2836 1053 12 a) Infiltration 136 39 525 151 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 300 300 Subtotal(lines 6 to 13) 817 533 3362 1504 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 27 10 14 Subtotal 817 533 3388 1514 15 Duct loads 32% 48% 261 257 32% 48% 1082 730 Total room load 1078 791 4471 2245 Air required(cfm) 51 35 211 99 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. --4cCb, 2020-Jul-30 11:52:19 Right-Suite®Universal 2019 19.0.08 RSU08101 Page 3 ...ocumnets\Wrightsoft HVAC\CHAMBERS RESIDENCE.rup Calc=MJ8 Front Door faces: S nn�.iaN�eo Right-J®Worksheet Job: AHU 1 Date: Jul 30,2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name HALL FOYER 2 Exposed wall 3.0 ft 10.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 19.0 x 3.0 ft 8.0 x 10.0 ft 5 Room area 57.0 ft2 80.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 n 8.96 9.41 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 n 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 n 8.96 9.41 0 0 0 0 0 0 0 0 11 2 glazing,clr low-e 0.320 n 8.96 6.00 0 0 0 0 0 0 0 0 V�/ 13A-40cs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0 I; GCI 2 glazing,clr low-e 0.320 a 8.96 24.95 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 a 8.96 24.95 0 0 0 0 0 0 0 0 13A40cs 0,143 s 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 W 13A-40cs 0,143 w 4.00 2.19 27 27 108 59 90 42 168 92 I;; GCCII 2 glazing,clr low-e 0.320 w 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 w 8.96 25.20 0 0 0 0 48 2 430 1209 2 glazing,clr low-e 0.320 w 8.96 14.69 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 57 57 90 78 80 80 127 109 F 22A-tph 1,358 38.02 0.00 57 3 114 0 80 10 380 0 6 c)AED excursion -11 466 Envelope loss/gain 313 127 1105 1876 12 a) Infiltration 51 15 169 49 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 300 Subtotal(lines 6 to 13) 363 141 1275 2225 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -363 -141 71 28 14 Subtotal 0 0 1346 2253 15 Duct loads 32% 48% 0 0 32% 48% 430 1087 FFTotal room load 0 0 1776 3339 Air required(cfm) 0 0 84 148 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. --4cCb, 2020-Jul-30 11:52:19 Right-Suite®Universal 2019 19.0.08 RSU08101 Page 4 ...ocumnets\Wrightsoft HVAC\CHAMBERS RESIDENCE.rup Calc=MJ8 Front Door faces: S nn�.iaN�eo Right-J®Worksheet Job: AHU 1 Date: Jul 30,2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name PANTRY LIVING 2 Exposed wall 12.0 ft 22.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 8.0 x 12.0 ft 1.0 x 448.0 ft 5 Room area 96.0 ft2 448.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 54 54 216 118 2 glazing,clr low-e 0.320 n 8.96 9.41 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 n 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 n 8.96 9.41 0 0 0 0 0 0 0 0 11 2 glazing,clr low-e 0.320 n 8.96 6.00 0 0 0 0 0 0 0 0 V�/ 13A-40cs 0.143 e 4.00 2.19 0 0 0 0 144 78 312 171 I; GCI 2 glazing,clr low-e 0.320 a 8.96 24.95 0 0 0 0 18 1 161 449 2 glazing,clr low-e 0.320 a 8.96 24.95 0 0 0 0 48 3 430 1198 13A40cs 0,143 s 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 W 13A-flocs 0,143 w 4.00 2.19 108 108 432 236 0 0 0 0 I;; GCCII 2 glazing,clr low-e 0.320 w 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 w 8.96 25.20 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 w 8.96 14.69 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 96 96 152 131 448 448 710 613 F 22A-tph 1,358 38.02 0.00 96 12 456 0 448 22 837 0 6 c)AED excursion -30 -164 Envelope loss/gain 1041 338 2667 2384 12 a) Infiltration 203 58 373 107 b) Room ventilation 0 0 1 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 1800 Subtotal(lines 6 to 13) 1244 396 3040 4291 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 97 38 14 Subtotal 1244 396 3137 4329 15 Duct loads 32% 48% 398 191 32% 48% 1002 2088 Total room load 1642 588 4139 6418 Air required(cfm) 77 26 195 284 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. --4cCb, 2020-Jul-30 11:52:19 Right-Suite®Universal 2019 19.0.08 RSU08101 Page 5 ...ocumnets\Wrightsoft HVAC\CHAMBERS RESIDENCE.rup Calc=MJ8 Front Door faces: S nn�.iaN�eo Right-J®Worksheet Job: AHU 1 Date: Jul 30,2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name WIC WIC 2 2 Exposed wall 7.0 ft 0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 8.0 x 7.0 ft 7.0 x 7.0 ft 5 Room area 56.0 ft2 49.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 n 8.96 9.41 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 n 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 n 8.96 9.41 0 0 0 0 0 0 0 0 11 2 glazing,clr low-e 0.320 n 8.96 6.00 0 0 0 0 0 0 0 0 V�/ 13A-40cs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0 I; GCI 2 glazing,clr low-e 0.320 a 8.96 24.95 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 a 8.96 24.95 0 0 0 0 0 0 0 0 13A40cs 0,143 s 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 W 13A-40cs 0,143 w 4.00 2.19 63 63 252 138 0 0 0 0 I;; GCCII 2 glazing,clr low-e 0.320 w 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 w 8.96 25.20 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 w 8.96 14.69 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 56 56 89 77 49 49 78 67 F 22A-tph 1,358 38.02 0.00 56 7 266 0 49 0 0 0 6 c)AED excursion -38 -5 Envelope loss/gain 607 176 78 62 12 a) Infiltration 119 34 0 0 b) Room ventilation 0 0 1 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 300 0 Subtotal(lines 6 to 13) 726 511 78 62 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 35 14 14 Subtotal 726 511 113 76 15 Duct loads 32% 48% 232 246 32% 48% 36 37 FFTotal room load 958 757 149 113 Air required(cfm) 45 33 7 5 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. --4cCb, 2020-Jul-30 11:52:19 Right-Suite®Universal 2019 19.0.08 RSU08101 Page 6 ...ocumnets\Wrightsoft HVAC\CHAMBERS RESIDENCE.rup Calc=MJ8 Front Door faces: S nn�.iaN�eo Right-J®Worksheet Job: AHU 1 Date: Jul 30,2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name KITCHEN DINING 2 Exposed wall 0 ft 19.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 16.0 x 19.0 ft 1.0 x 353.0 ft 5 Room area 304.0 ft2 353.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 99 51 204 112 2 glazing,clr low-e 0.320 n 8.96 9.41 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 n 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 n 8.96 9.41 0 0 0 0 48 0 430 452 11 2 glazing,clr low-e 0.320 n 8.96 6.00 0 0 0 0 0 0 0 0 V�/ 13A-40cs 0.143 e 4.00 2.19 0 0 0 0 72 48 192 105 I; GCI 2 glazing,clr low-e 0.320 a 8.96 24.95 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 a 8.96 24.95 0 0 0 0 24 1 215 599 13A40cs 0,143 s 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 W 2 glazing, 0.320 w 4.00 2.00 0 0 0 0 0 0 0 0 I;; GCCII 2 glazing,clr low-e 0.320 w 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 w 8.96 25.20 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 w 8.96 14.69 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 304 304 482 416 353 353 560 483 F 22A-tph 1,358 38.02 0.00 304 0 0 0 353 19 722 0 6 c)AED excursion -167 -232 Envelope loss/gain 482 249 2324 1519 12 a) Infiltration 0 0 322 92 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 2000 1500 Subtotal(lines 6 to 13) 482 2249 2646 3111 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 482 2249 2646 3111 15 Duct loads 32% 48% 154 1085 32% 48% 845 1501 FFTotal room load 636 3333 3491 4612 Air required(cfm) 30 147 164 204 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. --4cCb, 2020-Jul-30 11:52:19 Right-Suite®Universal 2019 19.0.08 RSU08101 Page 7 ...ocumnets\Wrightsoft HVAC\CHAMBERS RESIDENCE.rup Calc=MJ8 Front Door faces: S nn�.iaN�eo Right-J®Worksheet Job: AHU 2 Date: Jul 30,2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name AHU 2 MASTER BEDROOM 2 Exposed wall 106.0 ft 45.0 ft 3 Room height 9.0 ft 9.0 ft heat/cool 4 Room dimensions 1.0 x 410.0 ft 5 Room area 1375.0 ft2 410.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 n 4.00 2.19 153 132 527 288 72 72 288 158 2 glazing,clr low-e 0.320 n 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 n 8.96 9.41 21 0 191 201 0 0 0 0 2 glazing,clr low-e 0.320 n 0.00 0.00 0 0 0 0 0 0 0 0 11 2 glazing,clr low-e 0.320 n 0.00 0.00 0 0 0 0 0 0 0 0 V)/ 13A-40cs 0.143 e 0.00 0.00 0 0 0 0 0 0 0 0 I; GCI 2 glazing,clr low-e 0.320 a 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 a 0.00 0.00 0 0 0 0 0 0 0 0 13A40cs 0,143 s 4.00 2.19 630 503 2014 1101 162 132 529 289 2 glazing,clr low-e 0.320 s 8.96 9.41 12 12 108 113 0 0 0 0 2 glazing,clr low-e 0.320 s 8.96 9.41 30 30 269 282 30 30 269 282 2 glazing,clr low-e 0.320 s 8.96 9.41 40 40 358 376 0 0 0 0 2 glazing,clr low-e 0.320 s 8.96 9.41 25 25 224 235 0 0 0 0 2 glazing,clr low-e 0.320 s 8.96 9.41 20 20 179 188 0 0 0 0 W 13A-flocs 0.143 w 4.00 2.19 171 135 541 295 171 135 541 295 I;; GCCII 2 glazing,clr low-e 0.320 w 8.96 24.95 36 2 323 898 36 2 323 898 2 glazing,clr low-e 0.320 w 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 w 0.00 0.00 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 1375 1375 2180 1881 410 410 650 561 F 22A-tph 1,358 38.02 0.00 1375 106 4031 0 410 45 1711 0 6 c)AED excursion 195 342 Envelope loss/gain 10944 6054 4310 2825 12 a) Infiltration 1797 516 763 219 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 6200 1500 Subtotal(lines 6 to 13) 12741 12770 5073 4544 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 17 14 14 Subtotal 12741 12770 5089 4558 15 Duct loads 25% 36% 3132 4543 25% 36% 1251 1621 FFTotal room load 15873 17313 6340 6179 Air required(cfm) 800 800 320 286 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. --4cCb, 2020-Jul-30 11:52:19 Right-Suite®Universal 2019 19.0.08 RSU08101 Page 8 ...ocumnets\Wrightsoft HVAC\CHAMBERS RESIDENCE.rup Calc=MJ8 Front Door faces: S nn�.iaN�eo Right-J®Worksheet Job: AHU 2 Date: Jul 30,2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name M WIC 1 M WIC 2 2 Exposed wall 7.0 ft 6.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 7.0 x 15.0 ft 6.0 x 7.0 ft 5 Room area 105.0 ft2 42.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 n 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 n 8.96 9.41 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 n 0.00 0.00 0 0 0 0 0 0 0 0 11 2 glazing,clr low-e 0.320 n 0.00 0.00 0 0 0 0 0 0 0 0 V)/ 13A-40cs 0.143 e 0.00 0.00 0 0 0 0 0 0 0 0 I; GCI 2 glazing,clr low-e 0.320 a 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 a 0.00 0.00 0 0 0 0 0 0 0 0 13A40cs 0,143 s 4.00 2.19 63 63 252 138 54 54 216 118 2 glazing,clr low-e 0.320 s 8.96 9.41 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 8.96 9.41 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 8.96 9.41 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 8.96 9.41 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 8.96 9.41 0 0 0 0 0 0 0 0 W 2 glazing, 0.320 w 4.96 2.19 0 0 0 0 0 0 0 0 I;; GCCII 2 glazing,clr low-e 0.320 w 8.96 24.95 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 w 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 w 0.00 0.00 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 105 105 166 144 42 42 67 57 F 22A-tph 1,358 38.02 0.00 105 7 266 0 42 6 228 0 6 c)AED excursion -14 -12 Envelope loss/gain 685 267 511 163 12 a) Infiltration 119 34 102 29 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 500 500 Subtotal(lines 6 to 13) 804 801 613 692 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 804 801 613 692 15 Duct loads 25% 36% 198 285 25% 36% 151 246 FFTotal room load 1001 1086 763 939 Air required(cfm) 501 50 38 43 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. --4cCb, 2020-Jul-30 11:52:19 Right-Suite®Universal 2019 19.0.08 RSU08101 Page 9 ...ocumnets\Wrightsoft HVAC\CHAMBERS RESIDENCE.rup Calc=MJ8 Front Door faces: S nn�.iaN�eo Right-J®Worksheet Job: AHU 2 Date: Jul 30,2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name M BATH M TOILET 2 Exposed wall 15.0 ft 0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 229.0 ft 7.0 x 4.0 ft 5 Room area 229.0 ft2 28.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 n 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 n 8.96 9.41 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 n 0.00 0.00 0 0 0 0 0 0 0 0 11 2 glazing,clr low-e 0.320 n 0.00 0.00 0 0 0 0 0 0 0 0 V)/ 13A-40cs 0.143 e 0.00 0.00 0 0 0 0 0 0 0 0 I; GCI 2 glazing,clr low-e 0.320 a 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 a 0.00 0.00 0 0 0 0 0 0 0 0 13A40cs 0,143 s 4.00 2.19 135 98 392 214 0 0 0 0 2 glazing,clr low-e 0.320 s 8.96 9.41 12 12 108 113 0 0 0 0 2 glazing,clr low-e 0.320 s 8.96 9.41 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 8.96 9.41 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 8.96 9.41 25 25 224 235 0 0 0 0 2 glazing,clr low-e 0.320 s 8.96 9.41 0 0 0 0 0 0 0 0 W 2 glazing, 0.320 w 4.96 2.19 0 0 0 0 0 0 0 0 I;; GCCII 2 glazing,clr low-e 0.320 w 8.96 24.95 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 w 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 w 0.00 0.00 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 229 229 363 313 28 28 44 38 F 22A-tph 1,358 38.02 0.00 229 15 570 0 28 0 0 0 6 c)AED excursion -34 -4 Envelope loss/gain 1657 842 44 34 12 a) Infiltration 254 73 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 1000 200 Subtotal(lines 6 to 13) 1912 1915 44 234 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 41 35 21 18 14 Subtotal 1953 1950 65 252 15 Duct loads 25% 36% 480 694 25% 36% 16 90 FFTotal room load 2433 2643 81 341 Air required(cfm) 1231 122 4 16 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. --4cCb, 2020-Jul-30 11:52:19 Right-Suite®Universal 2019 19.0.08 RSU08101 Page 10 ...ocumnets\Wrightsoft HVAC\CHAMBERS RESIDENCE.rup Calc=MJ8 Front Door faces: S nn�.iaN�eo Right-J®Worksheet Job: AHU 2 Date: Jul 30,2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name HALLWAY DEN 2 Exposed wall 0 ft 15.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 15.0 x 4.0 ft 1.0 x 258.0 ft 5 Room area 60.0 ft2 258.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 n 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 n 8.96 9.41 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 n 0.00 0.00 0 0 0 0 0 0 0 0 11 2 glazing,clr low-e 0.320 n 0.00 0.00 0 0 0 0 0 0 0 0 V)/ 13A-40cs 0.143 e 0.00 0.00 0 0 0 0 0 0 0 0 I; GCI 2 glazing,clr low-e 0.320 a 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 a 0.00 0.00 0 0 0 0 0 0 0 0 13A40cs 0,143 s 4.00 2.19 0 0 0 0 135 95 380 208 2 glazing,clr low-e 0.320 s 8.96 9.41 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 8.96 9.41 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 8.96 9.41 0 0 0 0 40 40 358 376 2 glazing,clr low-e 0.320 s 8.96 9.41 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 8.96 9.41 0 0 0 0 0 0 0 0 W 13A�4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 I;; GCCII 2 glazing,clr low-e 0.320 w 8.96 24.95 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 w 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 w 0.00 0.00 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 60 60 95 82 258 258 409 353 F 22A-tph 1,358 38.02 0.00 60 0 0 0 258 15 570 0 6 c)AED excursion -1 -35 Envelope loss/gain 95 81 1718 902 12 a) Infiltration 0 0 254 73 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 1000 Subtotal(lines 6 to 13) 95 81 1972 1975 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -95 -81 51 43 14 Subtotal 0 0 2023 2018 15 Duct loads 25% 36% 0 0 25% 36% 497 718 FFTotal room load 0 0 2521 2736 Air required(cfm) 0 0 127 126 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. --4cCb, 2020-Jul-30 11:52:19 Right-Suite®Universal 2019 19.0.08 RSU08101 Page 11 ...ocumnets\Wrightsoft HVAC\CHAMBERS RESIDENCE.rup Calc=MJ8 Front Door faces: S nn�.iaN�eo Right-J®Worksheet Job: AHU 2 Date: Jul 30,2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name DEN CLST BATH 4 2 Exposed wall 0 ft 5.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 9.0 x 3.0 ft 5.0 x 10.0 ft 5 Room area 27.0 ft2 50.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 n 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 n 8.96 9.41 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 n 0.00 0.00 0 0 0 0 0 0 0 0 11 2 glazing,clr low-e 0.320 n 0.00 0.00 0 0 0 0 0 0 0 0 V)/ 13A-40cs 0.143 e 0.00 0.00 0 0 0 0 0 0 0 0 I; GCI 2 glazing,clr low-e 0.320 a 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 a 0.00 0.00 0 0 0 0 0 0 0 0 13A40cs 0,143 s 4.00 2.19 0 0 0 0 45 45 180 98 2 glazing,clr low-e 0.320 s 8.96 9.41 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 8.96 9.41 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 8.96 9.41 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 8.96 9.41 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 s 8.96 9.41 0 0 0 0 0 0 0 0 W 2 glazing, 0.320 w 4.96 2.19 0 0 0 0 0 0 0 0 I;; GCCII 2 glazing,clr low-e 0.320 w 8.96 24.95 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 w 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 w 0.00 0.00 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 27 27 43 37 50 50 79 68 F 22A-tph 1,358 38.02 0.00 27 0 0 0 50 5 190 0 6 c)AED excursion -1 -12 Envelope loss/gain 43 36 450 155 12 a) Infiltration 0 0 85 24 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 500 Subtotal(lines 6 to 13) 43 36 534 679 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -43 -36 0 0 14 Subtotal 0 0 534 679 15 Duct loads 25% 36% 0 0 25% 36% 131 242 FFTotal room load 0 0177, 666 921 Air required(cfm) 0 0 34 43 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. --4cCb, 2020-Jul-30 11:52:19 Right-Suite®Universal 2019 19.0.08 RSU08101 Page 12 ...ocumnets\Wrightsoft HVAC\CHAMBERS RESIDENCE.rup Calc=MJ8 Front Door faces: S nn�.iaN�eo Right-J®Worksheet Job: AHU 2 Date: Jul 30,2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name UTILITY 2 Exposed wall 13.0 ft 3 Room height 9.0 ft heat/cool 4 Room dimensions 1.0 x 166.0 ft 5 Room area 166.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 n 4.00 2.19 81 60 239 131 2 glazing,clr low-e 0.320 n 0.00 0.00 0 0 0 0 2 glazing,clr low-e 0.320 n 8.96 9.41 21 0 191 201 2 glazing,clr low-e 0.320 n 0.00 0.00 0 0 0 0 11 2 glazing,clr low-e 0.320 n 0.00 0.00 0 0 0 0 13A-4ocs 0.143 e 0.00 0.00 0 0 0 0 2 glazing,clr low-e 0.320 e 0.00 0.00 0 0 0 0 2 glazing,clr low-e 0.320 e 0.00 0.00 0 0 0 0 13A-4ocs 0.143 s 4.00 2.19 36 16 64 35 2 glazing,clr low-e 0.320 s 8.96 9.41 0 0 0 0 2 glazing,clr low-e 0.320 s 8.96 9.41 0 0 0 0 2 glazing,clr low-e 0,320 s 8.96 9.41 0 0 0 0 2 glazing,clr low-e 0.320 s 8.96 9.41 0 0 0 0 2 glazing,clr low-e 0.320 s 8.96 9.41 20 20 179 188 W 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 2 glazing,clr low-e 0.320 w 8.96 24.95 0 0 0 0 2 glazing,clr low-e 0.320 w 0.00 0.00 0 0 0 0 2 glazing,clr low-e 0.320 w 0.00 0.00 01 0 0 0 C 16X19-0md 0.408 1.59 1.37 166 166 263 227 F 22A-tph 1.358 38.02 0.00 166 13 494 0 6 c)AED excursion -32 Envelope loss/gain 1431 749 12 a) Infiltration 220 63 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 1000 Subtotal(lines 6 to 13) 1651 1813 Less external load 0 0 Less transfer 0 0 Redistribution 9 7 14 Subtotal 1660 1820 15 Duct loads 25% 36% 408 647 FFTotal room load 2068 2467 Air required(cfm) 104 114 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. --4cCb, -I- �aN�ao ,.. 2020-Jul-30 11:52:19 Right-Suite®Universal 2019 19.0.08 RSU08101 Page 13 ...ocumnets\Wrightsoft HVAC\CHAMBERS RESIDENCE.rup Calc=MJ8 Front Door faces: S Art Liapfaotr, Duct System Summary Job: Date: Jul 30,2020 AHU 1 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM Project • • For: CHAMBERS RESIDENCE, COLE CONSTRUCTION SERVICES, LLC. 4700 INDRIO ROAD, FORT PIERCE, FL 34951 Heating Cooling External static pressure 1.00 in H2O 1.00 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 1.00 in H2O 1.00 in H2O Supply/ return available pressure 0.500/ 0.500 in H2O 0.500/0.500 in H2O Lowest friction rate 1.000 in/100ft 1.000 in/100ft Actual air flow 1173 cfm 1173 cfm Total effective length (TEL) 190 ft Supply Branch DetailTable Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FIR (in) (in) Matl Ln (ft) Ln (ft) Trunk BATH 2 h 1078 51 35 1.000 5.0 Ox 0 VIFx 14.3 115.0 st 1 BATH 3 c 560 10 25 1.000 5.0 Ox 0 VIFx 7.3 115.0 st3 BEDROOM 2 h 4471 211 99 1.000 7.0 Ox0 VIFx 10.1 115.0 st1 BEDROOM 3 h 5416 255 152 1.000 8.0 Ox0 VIFx 10.1 115.0 st3 DINING c 2306 82 102 1.000 7.0 Ox0 VIFx 53.7 135.0 st6 DINING-A c 2306 82 102 1.000 7.0 Ox0 VIFx 54.7 135.0 st6 FOYER c 3339 84 148 1.000 8.0 Ox 0 VIFx 13.6 115.0 st3 KITCHEN c 3333 30 147 1.000 8.0 Ox0 VIFx 31.1 115.0 st2 LIVING c 3209 97 142 1.000 8.0 Ox0 VIFx 13.7 115.0 st1 LIVING-A c 3209 97 142 1.000 8.0 Ox0 VIFx 18.3 115.0 st1 PANTRY h 1642 77 26 1.000 5.0 Ox0 VIFx 34.0 115.0 st2 WIC h 958 45 33 1.000 5.0 Ox0 VIFx 34.5 115.0 st2 WIC 2 h 149 7 5 1.000 4.0 Ox0 VIFx 11.7 115.0 st1 WIC 3 h 943 44 15 1.000 4.0 Ox0 VIFx 11.4 115.0 st3 SupplyDetail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st6 Peak AVF 164 204 1.000 374 10.0 0 x 0 VinlFlx st2 st2 Peak AVF 317 411 1.000 523 12.0 0 x 0 VinlFlx st3 Peak AVF 393 339 1.000 721 10.0 0 x 0 VinlFlx st1 Peak AVF 463 423 1.000 590 12.0 0 x 0 VinlFlx �C� MI.IaFlZO � 2020-Jul-30 11:52:29 Right-Suite®Universal 2019 19.0.08 RSU08101 Page 1 r ...ocumnets\Wrightsoft HVAC\CHAMBERS RESIDENCE.rup Calc=MJ8 Front Door faces: S TableReturn Branch Detail Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb2 Ox0 1173 1173 0 0 0 0 Ox 0 VIFx �C� MI.IaFlZO � 2020-Jul-30 11:52:29 Right-Suite®Universal 2019 19.0.08 RSU08101 Page 2 r ...ocumnets\Wrightsoft HVAC\CHAMBERS RESIDENCE.rup Calc=MJ8 Front Door faces: S Art Liapfaotr, Duct System Summary Job: Date: Jul 30,2020 AHU 2 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM Project • • For: CHAMBERS RESIDENCE, COLE CONSTRUCTION SERVICES, LLC. 4700 INDRIO ROAD, FORT PIERCE, FL 34951 Heating Cooling External static pressure 1.00 in H2O 1.00 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 1.00 in H2O 1.00 in H2O Supply/ return available pressure 0.500/ 0.500 in H2O 0.500/0.500 in H2O Lowest friction rate 1.000 in/100ft 1.000 in/100ft Actual air flow 800 cfm 800 cfm Total effective length (TEL) 176 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FIR (in) (in) Matl Ln (ft) Ln (ft) Trunk BATH 4 c 921 34 43 1.000 6.0 Ox 0 VIFx 38.0 135.0 st7 DEN h 2521 127 126 1.000 7.0 Ox0 VIFx 40.6 135.0 st7 M BATH h 2433 123 122 1.000 7.0 Ox0 VIFx 7.9 115.0 st4 M TOILET c 341 4 16 1.000 4.0 Ox0 VIFx 9.1 115.0 st4 M WIC 1 h 1001 50 50 1.000 4.0 Ox0 VIFx 9.1 115.0 st5 MWIC2 c 939 38 43 1.000 6.0 Ox0 VIFx 10.9 115.0 st4 MASTER BEDROOM h 3170 160 143 1.000 8.0 Ox0 VIFx 13.8 115.0 st5 MASTER BEDROOM-A h 3170 160 143 1.000 8.0 Ox0 VIFx 12.1 115.0 st5 UTILITY c 2467 104 114 1.000 7.0 Ox0 VIFx 36.7 135.0 st7 SupplyTrunk Detail Table Trunk Htg CIg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st7 Peak AVF 265 283 1.000 519 10.0 0 x 0 VinlFlx st4 st4 Peak AVF 430 464 1.000 591 12.0 0 x 0 VinlFlx st5 Peak AVF 370 336 1.000 678 10.0 0 x 0 VinlFlx �C� MI.IaFlZO � 2020-Jul-30 11:52:29 Right-Suite®Universal 2019 19.0.08 RSU08101 Page 3 r ...ocumnets\Wrightsoft HVAC\CHAMBERS RESIDENCE.rup Calc=MJ8 Front Door faces: S TableReturn Branch Detail Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb1 Ox0 800 800 0 0 0 0 Ox 0 VIFx �C� MI.IaFlZO � 2020-Jul-30 11:52:29 Right-Suite®Universal 2019 19.0.08 RSU08101 Page 4 r ...ocumnets\Wrightsoft HVAC\CHAMBERS RESIDENCE.rup Calc=MJ8 Front Door faces: S This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF.