HomeMy WebLinkAbout5703 Hickory Drive Energygauge/deferred SubmittalEnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 64/29/2020 4:46 PM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction:
Habitat for Humanity
Joseph W. Gianna
5703 Hickory Drive Energygauge
Street:
City, State, Zip: Ft. Pierce , FL ,
5703 Hickory Drive
Permit Number:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
New (From Plans)
Single-family
1
No
1335
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
d. U-Factor:
S H G C :
Dbl, U=0.60 118.62 ft²
SHGC=0.24
N/A f t ²
N/A f t ²
N/A f t ²
8. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 1335.30 ft²
R=f t ²
R=f t ²
9. Wall Types
a. Concrete Block - Int Insul, Exterior R=3.0 1092.00 ft²
b. Concrete Block - Int Insul, Adjacent R=3.0 236.00 ft²
c. N/A R=f t ²
10. Ceiling Types
a. Under Attic (Vented)R=30.0 1338.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Garage
12. Cooling systems
13. Heating systems
14. Hot water systems
a. Electric Cap: 40 gallons
b. Conservation features
None
d. N/A R=f t ²
Area Weighted Average Overhang Depth:3.252 ft.
Area Weighted Average SHGC:0.240
Description Area
Insulation Area
Insulation Area
Insulation Area
15. Credits C F
3
(118.6 sqft.)
(1328.0 sqft.)
(1338.0 sqft.)
(1335.3 sqft.)
Conditioned floor area below grade (ft²) 0
a. Central Unit
a. Electric Strip Heat
k B t u / h r
27.6 SEER:16.00
Efficiency
k B t u / h r Efficiency
27.3 COP:1.00
f t ² R
6 267
EF: 0.950
Glass/Floor Area: 0.089
Total Proposed Modified Loads:
Total Baseline Loads:
46.29
46.87 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2017
April 29, 2020
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Habitat for Humanity
1
Joseph W. Gianna
5703 Hickory Drive Energyga
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle: 0
No
1
1335
3
New (From Plans)
Single-family
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL ,
Ft. Pierce ,
St. Lucie
5703 Hickory Drive
Street Address
Comment:
Building Type: User
Cross Ventilation: No
Whole House Fan: No
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 % Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 Entire House 1335 10680
Number Name Area Volume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 Bed 2 191 1528 No 1 1 Yes Yes1 Yes
2 c2 18 144 No 0 Yes Yes1 Yes
3 Bath 2 117 936 No 0 Yes Yes1 Yes
4 Bed 3 194 1552 No 1 1 Yes Yes1 Yes
5 c3 23 184 No 0 Yes Yes1 Yes
6 Living Rm 244 1952 No 0 Yes Yes1 Yes
7 Kitchen 250 2000 Yes 0 Yes Yes1 Yes
8 Bed 1 174 1392 No 1 1 Yes Yes1 Yes
9 pnty 21 168 No 0 Yes Yes1 Yes
10 clst 1 18 144 No 0 Yes Yes1 Yes
11 Bath 1 85 680 No 0 Yes Yes1 Yes
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
1 190.5 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -32.5 ft Bed 2
2 17.5 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -2.5 ft c2
3 117 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -9 ft Bath 2
4 193.5 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -26.5 ft Bed 3
5 22.5 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -3 ft c3
6 245 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -14 ft Living Rm
4/29/2020 4:46 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
7 252 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -14 ft Kitchen
8 174 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -12 ft Bed 1
9 21.3 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -2.5 ft pnty
10 17.5 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -2.5 ft clst 1
11 84.5 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -18 ft Bath 1
# Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1 Gable or Shed Composition shingles 1407 ft² Medium 0.9 0 18.4______No222 ft² 0.9 NoN
ATTIC
# Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 Full attic Vented 1335 ft² N N300
# Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Vented) 30 191 ft² 0.1 Wood______ Bed 2 Blown
2 Under Attic (Vented) 30 18 ft² 0.1 Wood______ c2 Blown
3 Under Attic (Vented) 30 117 ft² 0.1 Wood______ Bath 2 Blown
4 Under Attic (Vented) 30 194 ft² 0.1 Wood______ Bed 3 Blown
5 Under Attic (Vented) 30 23 ft² 0.1 Wood______ c3 Blown
6 Under Attic (Vented) 30 245 ft² 0.1 Wood______ Living Rm Blown
7 Under Attic (Vented) 30 252 ft² 0.1 Wood______ Kitchen Blown
8 Under Attic (Vented) 30 174 ft² 0.1 Wood______ Bed 1 Blown
9 Under Attic (Vented) 30 21 ft² 0.1 Wood______ pnty Blown
10 Under Attic (Vented) 30 18 ft² 0.1 Wood______ clst 1 Blown
11 Under Attic (Vented) 30 85 ft² 0.1 Wood______ Bath 1 Blown
WALLS
# Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
13 0Bed 2 00068E Concrete Block - Int Insul 0.550Exterior48.0 ft² ____
23 0Bed 2 00013 8S Concrete Block - Int Insul 0.550Exterior104.0 ft² ____
33 0Bed 2 00613 8W Concrete Block - Int Insul 0.550Exterior108.0 ft² ____
43 0c2 00628W Concrete Block - Int Insul 0.550Exterior20.0 ft² ____
53 0Bath 2 00098W Concrete Block - Int Insul 0.550Exterior72.0 ft² ____
63 0Bed 3 00013 8N Concrete Block - Int Insul 0.550Exterior104.0 ft² ____
73 0Bed 3 00613 8W Concrete Block - Int Insul 0.550Exterior108.0 ft² ____
83 0c3 00038W Concrete Block - Int Insul 0.550Exterior24.0 ft² ____
4/29/2020 4:46 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
# Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
93 0Living Rm 00014 8S Concrete Block - Int Insul 0.550Exterior112.0 ft² ____
10 3 0Living Rm 00015 8E Concrete Block - Int Insul 0.550Garage120.0 ft² ____
11 3 0Kitchen 00014 8N Concrete Block - Int Insul 0.550Exterior112.0 ft² ____
12 3 0Bed 1 00012 8E Concrete Block - Int Insul 0.550Exterior96.0 ft² ____
13 3 0Bed 1 00614 8S Concrete Block - Int Insul 0.550Garage116.0 ft² ____
14 3 0pnty 00628N Concrete Block - Int Insul 0.550Exterior20.0 ft² ____
15 3 0clst 1 00628E Concrete Block - Int Insul 0.550Exterior20.0 ft² ____
16 3 0Bath 1 00012 8N Concrete Block - Int Insul 0.550Exterior96.0 ft² ____
17 3 0Bath 1 00068E Concrete Block - Int Insul 0.550Exterior48.0 ft² ____
# Door Type U-Value AreaStorms
DOORS
Ornt Space
Width
Ft In Ft In
Height
1 Wood .39 21 ft² None______ S Living Rm 73
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1 S Double (Clear) 0.6 0.24 16.4 ft² 2 ft 0 in 1 ft 0 in Drapes/blindsMetal Exterior 5______ Yes2Y
2 W Double (Clear) 0.6 0.24 7.4 ft² 2 ft 0 in 1 ft 0 in Drapes/blindsMetal Exterior 5______ Yes5Y
3 N Double (Clear) 0.6 0.24 16.4 ft² 2 ft 0 in 1 ft 0 in Drapes/blindsMetal Exterior 5______ Yes6Y
4 S Double (Clear) 0.6 0.24 24.0 ft² 6 ft 0 in 1 ft 0 in Drapes/blindsMetal Exterior 5______ Yes9Y
5 N Double (Clear) 0.6 0.24 21.0 ft² 4 ft 6 in 1 ft 0 in Drapes/blindsMetal None______ Yes11 Y
6 N Double (Clear) 0.6 0.24 9.5 ft² 2 ft 0 in 1 ft 0 in Drapes/blindsMetal Exterior 5______ Yes11 Y
7 E Double (Clear) 0.6 0.24 16.4 ft² 2 ft 0 in 1 ft 0 in Drapes/blindsMetal Exterior 5______ Yes12 Y
8 N Double (Clear) 0.6 0.24 7.4 ft² 2 ft 0 in 1 ft 0 in Drapes/blindsMetal Exterior 5______ Yes16 Y
# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
GARAGE
1 382.8 ft² 382.8 ft² 64 ft 8 ft 1______
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
890 548.86.000254Wholehouse .088191.89Proposed ACH(50)1
4/29/2020 4:46 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtypeBlock
1 Electric Strip Heat/ COP:1 27.3 kBtu/hr ______sys#1None1
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtypeBlock
1 Central Unit/ SEER: 16 27.6 kBtu/hr c f m 0.74______sys#1Split1
# System Type EF Cap Use SetPnt Conservation
HOT WATER SYSTEM
SubType Location
1 Electric 0.95 40 gal 60.9 gal 120 deg None______ None Garage
FSEC
Company Name System Model # Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert #Area Volume
None None f t ² ______
# Location R-Value Area Location Area
---- Supply ---- ---- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6 267 ft² Attic 67 ft² Default Leakage Garage ( D e f a u l t ) ______1 1 ( D e f a u l t )
TEMPERATURES
Programable Thermostat: N Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec[X] Dec[X] Nov[X] Nov[ ] Oct[X] Oct[ ] Sep[ ] Sep[ ] Aug[ ] Aug[ ] Jul[ ] Jul[ ] Jun[ ] Jun[X] Jun[ ] May[ ] May[ ] Apr[X] Apr[X] Mar[X] Mar[X] Feb[ ] Feb[X] Jan[ ] JanHeatingVenting
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 123456789101112
Cooling (WD) AMPM 7880 7880 7880 7880 7878 7878 7878 7878 8078 8078 8078 8078
Cooling (WEH) AMPM 7880 7880 7880 7880 7878 7878 7878 7878 8078 8078 8078 8078
Heating (WD) AMPM 6568 6568 6568 6568 6568 6568 6568 6868 6868 6868 6868 6868
Heating (WEH) AMPM 6568 6568 6568 6568 6568 6568 6568 6868 6868 6868 6868 6868
4/29/2020 4:46 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft. 0 ft² 0 ft 0.3 Bed 2
Default(8 lbs/sq.ft. f t ² f t 0.3 c2
Default(8 lbs/sq.ft. f t ² f t 0.3 Bath 2
Default(8 lbs/sq.ft. f t ² f t 0.3 Bed 3
Default(8 lbs/sq.ft. f t ² f t 0.3 c3
Default(8 lbs/sq.ft. f t ² f t 0.3 Living Rm
Default(8 lbs/sq.ft. f t ² f t 0.3 Kitchen
Default(8 lbs/sq.ft. f t ² f t 0.3 Bed 1
Default(8 lbs/sq.ft. f t ² f t 0.3 pnty
Default(8 lbs/sq.ft. f t ² f t 0.3 clst 1
Default(8 lbs/sq.ft. f t ² f t 0.3 Bath 1
4/29/2020 4:46 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT