Loading...
HomeMy WebLinkAboutWind calcsNewSouth WINDOW SOLUTIONS 2526 Okeechobee Blvd, West Palm Beach, FL 33409 • 561-712-9000 • CRC1330822 Property Information Building Information Owner: Apirl Masters Wind Zone: 170 MPH. Address: 246 NE Mainsail St Exposure Category: C Port St Lucie, FL 34983 Minimum Building Dimension: 25 ft. Mean Roof Height 15 ft. Risk Category: 11 Desi n Pressure Calculations Opening Location Device Device Device Max Positive g Max Negative Number Zone Width (in) Height (in) Elevation (ft) Pressure (psf) Pressure (psf) 1 Int 95.75 62 7 34.3 -37.5 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Compomms and Cladding. 61h Edition (1017) Florida Building Code. Page I of 1