HomeMy WebLinkAboutWind calcsNewSouth
WINDOW SOLUTIONS
2526 Okeechobee Blvd, West Palm Beach, FL 33409 • 561-712-9000 • CRC1330822
Property Information
Building
Information
Owner: Apirl Masters
Wind Zone:
170 MPH.
Address: 246 NE Mainsail St
Exposure Category:
C
Port St Lucie, FL 34983
Minimum Building Dimension: 25 ft.
Mean Roof Height
15 ft.
Risk Category:
11
Desi n Pressure Calculations
Opening Location Device Device Device Max Positive g Max Negative
Number Zone Width (in) Height (in) Elevation (ft) Pressure (psf) Pressure (psf)
1 Int 95.75 62 7 34.3 -37.5
Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Compomms and Cladding. 61h Edition (1017) Florida Building Code.
Page I of 1