Loading...
HomeMy WebLinkAboutWind zone, project infoNewSouth WINDOW SOLUTIONS W)A nt.e hnhee RI..rl West Palm Beach. FL 33409 • 561-712-9000 • CRC 1330822 Propeny Information Buildin Information Owner: Leslie Rosenwasser Wind Zone: 170 MPH. Address: 9005 One Putt PI Exposure Category: C Port St Lucie, FI 34986 Minimum Building Dimension: 25 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width (in) Height (in) Elevation (ft) Pressure (psf) Pressure (psf) 1 Int 53.50 27 7 37.8 -41.0 2 Int 53.50 27 7 37.8 -41.0 3 Int 71.75 21 7 37.4 -40.6 4 Int 72 61.50 7 35.0 -38.2 5 Int 71.75 21 7 37.4 -40.6 6 Int 72 61.50 7 35.0 -38.2 7 Int 72 61.50 7 35.0 -38.2 8 Int 71.75 21 7 37.4 -40.6 9 Int 72 21.25 7 37.3 -40.6 10 Int 71.75 21 7 37.4 40.6 11 Int 72 70.75 7 34.7 -37.9 12 Int 35 61.50 7 36.8 40.0 13 Int 35 61.50 7 36.8 -40.0 14 Int 35 4.2 36.25 7 37.8 41.0 15 Int 24 12 7 37.8 -41.0 16 Int 24.25 37 7 37.8 41.0 17 Int 35 17.50 7 37.8 41.0 18 Int 35 61.50 7 36.8 -40.0 19 Int 35 17.50 7 37.8 41.0 20 Int 35 44.50 7 37.6 40.8 21 Int 24.75 37 7 37.8 41.0 22 Int 24.50 75.50 7 37.1 -40.3 23 Int 24.50 75.50 7 37.1 -40.3 Prepared in accordance with: ASCE 7-10. Chapter 30. Wind Loads - Compomnis and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1