Loading...
HomeMy WebLinkAboutGenerac , project infoGENERAC° Protector® QS Series INCLUDES: • Two -Line LCD Multilingual Digital Evolution'" Controller (English/Spanish/ French/Portuguese) with external viewing window for easy indication of generator status and breaker position. • True Power'" Electrical Technology • Isochronous Electronic Governor • Sound Attenuated Enclosure • Closed Coolant Recovery System • Smart Battery Charger • UV/Ozone Resistant Hoses • ±1%Voltage Regulation • Natural Gas or LP Operation • 5 Year Limited Warranty • UL 2200 Listed • Capability to be installed within 18" (457) mm of a building* PROTECTOR® QS SERIES Standby Generators Liquid -Cooled Gaseous Engine Standby Power Rating Model RG022 (Aluminum - Bisque) - 22 kW 60 Hz " Model RG027 (Aluminum - Blsqup) - 27 kW 60 Hz Model RG032 (Aluminum - Bisque) - 32 kW 60 Hz Model RG038 (Aluminum - Bisque) - 38 kW 60 Hz Model RG048 (Aluminum - Bisque) - 48 kW 60 Hz ETA QUEHEST �mN •",.e�aea a m. us" mw Meets EPA Emission Regulations 22 & 27 kW are CA/MA emissions compliant *Only if located away from doors, windows, and fresh air 32 & 38 kW not for sale in CA / MA intakes, and unless otherwise directed by local codes. FEATURES O INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. GENERAC'S success in "IMPROVING POWER BY DESIGN." But it This state-of-the-art power maximizing regulation system is standard on doesn't stop there. Total commitment to component testing, reliability all Generac models. It provides optimized FAST RESPONSE to changing testing, environmental testing, destruction and life testing, plus testing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by to applicable CSA, NEMA, EGSA, and other standards, allows you to electronically torque -matching the surge loads to the engine. Digital choose GENERAC POWER SYSTEMS with the confidence that these voltage regulation at ±1%. systems will provide superior performance. O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES. Long life and reliability are PROTOTYPE TESTED NEMA MG1-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. ISO 900 1: 2008 GENERAC" 22 � 27 . 32 9 38 . 48 kW GENERATOR SPECIFICATIONS Type Synchronous Rotor Insulation Class H (22 & 27 kW) or F (32, 38 & 48 kW) Stator Insulation Class H Telephone Interference Factor (TIF) <50 Alternator Output Leads 1-Phase 4 wire Alternator Output Leads 3-Phase 6 wire Bearings Sealed Ball Coupling Flexible Disc Excitation System Direct VOLTAGE REGULATION Type Electronic Sensing Single Phase Regulation ' 1% GOVERNOR SPECIFICATIONS Type Electronic Frequency Regulation Isochronous Steady State Regulation ± 0.25% ELECTRICAL SYSTEM Battery Charge Alternator 12 Volt 30 Amp Static Battery Charger 2.5 Amp Recommended Battery (battery not included) Group 26 (22, 27, 32 & 38 kW) or Group 24F (48 kW), 525CCA System Voltage 12 Volts GENERATOR FEATURES Revolving field heavy duty generator Directly connected to the engine Operating temperature rise 120 °C above a 40 °C ambient Class H insulation is NEMA rated Class F insulation is NEMA rated All models fully prototyped tested ENCLOSURE FEATURES Ensures protection against mother nature. Aluminum weather Electrostatically applied textured epoxy paint for added protective enclosure durability. Enclosed critical grade Quiet, critical grade muffler is mounted inside the unit muffler to prevent injuries. Small, compact, attractive Makes for an easy, eye appealing installation. SAE Sound attenuated enclosure ensures quiet operation. (All ratings in accordance with BS5514, IS03046, IS08528, SAE A349 and DIN6271) application & engineering data ENGINE SPECIFICATIONS: 22, 27, 32 & 38 kW Make Generac Model In -line Cylinders 4 Displacement (Liters) 2.4 Bore (in/mm) 3.41/86.5 Stroke (in/mm) 3.94/100 Compression Ratio 9.5:1 Intake Air System Naturally Aspirated (22 & 27 kW) or Turbocharged/Aftercooled (32 & 38 kW) Lifter Type Hydraulic ENGINE SPECIFICATIONS: 48 kW Make Generac Model V Type Cylinders 8 Displacement (Liters) 5.4 Bore (in/mm) 3.55/90.2 Stroke (in/mm) 4.17/105.9 Compression Ratio 9:1 Intake Air System Naturally Aspirated Lifter Type Hydraulic ENGINE LUBRICATION SYSTEM Oil Pump Type Gear Oil Filter Type Full flow spin -on cartridge 4/3.8 (22, 27, 32 & 38 kW) or Crankcase Capacity (qVI) 6/5.7 (48 kW) ENGINE COOLING SYSTEM Type Closed Water Pump Belt driven 1980 - 22 & 27 kW Fan Speed (rpm) 1500 - 32 & 38 kW 1954 - 48 kW 18.1/459.7 (22 & 27 kW) or Fan Diameter (in/mm) 22/558.8 (32, 38 & 48 kW) Pusher (22 & 27 kW) or Fan Mode Puller (32. 38 & 48 kW) FUEL SYSTEM Fuel Type Natural gas, propane vapor Carburetor Down Draft Secondary Fuel Regulator Standard Fuel Shut Off Solenoid Standard Operating Fuel Pressure 5-14" water column/9-26 mm HG LP Fuel Pressure 11 - 14" Water Column NG Fuel Pressure 5 -14" Water Column GENERAC' 22,�27.32.38.48kW operating data GENERATOR OUTPUT VOLTAGEAW - 60 Hz kW LPG Amp LPG kW Nat. Gas Amp Nat. Gas GB Size (Both) 100 RG022 120/240 V, 10, 1.0 pf 120/208 V, 30, 0.8 pf 120/240 V, 30, 0.8 pf RG027 120/240 V, 10, 1.0 pf 120/208 V, 30, 0.8 pf 120/240 V, 30, 0.8 pf RG032 120/240 V, 10, 1.0 pf 120/208 V, 30, 0.8 pf 120/240 V, 30, 0.8 pf 277/480 V, 30, 0.8 pf RG038 120/240 V, 10, 1.0 pf 120/208 V, 30, 0.8 pf 120/240 V, 30. 0.8 pf 277/480 V, 30, 0.8 pf R6048 120/240 V, 10, 1.0 pf 120/208 V, 30, 0.8 pf 120/240 V, 30, 0.8 pf 277/480 V, 30. 0.8 pf 22 92 22 92 22 76 22 76 80 22 66 22 66 80 27 113 25 104 125 27 94 25 87 100 27 81 25 75 90 32 133 32 133 150 32 111 32 111 125 32 96 32 96 100 32 48 32 48 60 38 158 38 158 175 38 132 38 132 150 38 114 38 114 125 38 57 38 57 60 48 200 48 200 200 48 167 48 167 175 48 144 48 144 150 48 1 72 48 72 80 SURGE CAPACITY IN AMPS ENGINE FUEL CONSUMPTION Voltage Dip @ < .4 pf Natural Gas Propane 15% 30% (tt3/hr) (m3/hr) (gal/hr) (1/hr) (ft3/hr) 120/240 V, 10 55 135 RGO22 120/208 V, 30 40 92 120/240 V, 30 35 80 RG027 120/240 V, 10 62 170 30 120W 70 120 12030 61 103 12010 75 180 12030 87 210 RG032 1230 75 18227 30 36 8712 10 75 18012, 30 87 210 RG038 120/240 V. 30 75 182 277/480 V, 30 36 87 120/240 V, 10 85 195 120/208 V, 30 90 218 RG048 120/240 V, 30 78 189 277/480 V, 30 36 87 Note: Fuel pipe must be sized for full load. For Btu content, multiply ft3/hr x 2520 (LP) or ft3/hr x 1000 (NG) For megajoule content, multiply m3/hr x 93.15 (LP) or m3/hr x 37.26 (NG) Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and SCADMD ermittin purposes Exercise cycle 42 1.2 0.44 1.7 16 25% of rated load 100 2.8 1.1 4.2 40 [RGO22 50% of rated load 190 5.4 2.1 7.8 75 75% of rated load 255 7.2 2.8 10.5 101 100% of rated load 316 9 3.4 13 125 Exercise cycle 42 1.2 0,44 1.7 16 25% of rated load 108 3.1 1.2 4.5 43 RG027 50% of rated load 197 5.6 2.1 8.1 78 75% of rated load 287 8.2 3.1 11.8 114 100% of rated load 359 10.2 3.9 14.8 143 Exercise cycle 79 2.2 0.8 3.2 30 RG032 25% of rated load 144 4.1 1.7 6.3 60 50% of rated load 226 6.4 2.7 10.3 97 75% of rated load 298 6.4 3.7 13.9 132 100% of rated load 375 10.6 4.6 17.5 166 Exercise cycle 83 2.3 0.9 3.2 31 25% of rated load 162 4.6 1.7 6.6 62 RG038 50% of rated load 255 7.2 2.9 10.8 103 75% of rated load 345 9.8 4 15 142 100% of rated load 437 12.4 5.2 19 185 Exercise cycle 95 2.7 1 3.9 38 25% of rated load 204 5.8 2.16 8.5 82 RG048 50% of rated load 392 11.1 4.14 15.7 151 75% of rated load 547 15.5 5.8 22.8 220 100% of rated load 756 21.5 T. 31.3 302 P 9 STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice. GENERAL" 22 y 27 • 32 • 38 • 48 kW ENGINE COOLING operating data 22 kW 27 kW 32 & 38 kW 48 kW Air flow (inlet air including alternator and combustion air in cfm/cmm) 2400/68 2400/68 2200/62.3 4350/123.2 System coolant capacity (gal/liters) 2.5/9.5 2.5/9.5 2.5/9.5 3/11.4 Heat rejection to coolant (BTU per hr/MJ per hr) 99,000/104.5 105,000/110.8 145,000/153 186.000/196.2 Maximum operation air temperature on radiator (°C/°F) Maximum ambient temperature (°C/°F) 60/150 50/140 777t COMBUSTION REQUIREMENTS Flow at rated power (cfm/cmm) 68/1.9 68/1.9 106/3 163/4.6 SOUND EMISSIONS Sound output in dB(A) at 23 ft (7 m) with generator in exercise mode" 61 61 58 63 Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load' 1 70 70 64 68 `Sound levels are taken from the front of the generator, Sound levels taken from other sides of the generator may be higher depending on installation parameters. EXHAUST Exhaust flow at rated output (cfm/cmm) 1 165/4.7 1 180/5.1 1 300/8.5 1 414/11.7 Exhaust temperature at mu ler outlet (°C/°F) 1 482/900 1 538/1000 1579/1075 552/1 D25 7] ENGINE PARAMETERS Rated Synchronous rpm 1800 POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration........................................................................................................... 3% for every 10 °C above 25 °C or 1.65% for every 10 °F above 77 °F Altitude Deration (22, 27 & 48 kW).....................................................................................1 % for every 100 m above 183 m or 3% for every 1000 It above 600 ft Altitude Deration (32 & 38 kW).......................................................................................1 % for every 100 m above 915 m or 3% for every 1000 ft above 3000 ft CONTROLLER FEATURES Two -Line Plain Text LCD Display....................................................................................................................................Simple user interface for ease of operation. Mode Switch: Auto..............................................................................................................................................Automatic Start on Utility failure. 7 day exerciser Off...........................................................................................................................Stops unit. Power is removed. Control and charger still operate. Manual......................................................................................... Start with starter control, unit stays on. If utility fails, transfer to load takes place. Programmable start delay between 10-30 seconds sec standard ................................................................................................................................................10 Engine Start Sequence..................................................................................................................... Cyclic cranking:16 sec on, 7 rest (90 sec maximum duration) EngineWarm-up.....................................................................................................................................................................................................................5 sec min EngineCool-Down..................................................................................................................................................................................................................1 Starter Lock-out................................................................................................................................Starter cannot re-engage until 5 sec after engine has stopped. SmartBattery Charger........................................................................................................................................................................................................Standard Automatic Voltage Regulation with Over and Under Voltage Protection................................................................................................................................ Standard AutomaticLow Oil Pressure Shutdown..................................................................................................................................................................... ....... Standard OverspeedShutdown..............................................................................................................................................................................................Standard. 72 Hz HighTemperature Shutdown...............................................................................................................................................................................................Standard OvercrankProtection.......................................................................................................................................................................................................... Standard SafetyFused......................................................................................................................................................................................................................Standard Failureto Transfer Protection..............................................................................................................................................................................................Standard LowBattery Protection........................................................................................................................................................................................................ Standard 50 Event Run Log............................................................................................................................................................................................................... Standard FutureSet Capable Exerciser.. ............................................................................................................................................................................................ Standard IncorrectWiring Protection.................................................................................................................................................................................................Standard InternalFault Protection.....................................................................................................................................................................................................Standard Common External Fault Capability .................... Standard GovernorFailure Protection................................................................................................................................................................................................Standard