Loading...
HomeMy WebLinkAboutDuPont Protec 160 with cover5/12/2020 Miami-Dade County Building Product Information for N.O.A. 19-0828.02 NOA Superseded_By File Status File Classification Category Subcategory Material Applicant Expiration_Date Impact_Rate Maximum_Design _Pressure _Positive - Miami-Dade County 19-0828.02 . _(/ibrarrip"roduclcontro/lnoaI1 9082802.p"df ). File Approved High velocity hurricane zone Roofing Underlayments Polypropylene DuPont de Nemours, Inc. (l2c-resu/t detail ap'p".asl2?arm a/ias=103205 J. January/23/2025 Unselected I Unknown o Maximum_Design _Pressure_Negative 0 Description DuPont Tyvek ProTec 120, DuPont Tyvek ProTec 160, DuPont Tyvek ProTec 200 Green_Sustainable_Attributes NONE For a detailed description on the File Status, click the NOA File Status Key.,__((building(Rc-resulf keYJP'p".asp..). Page Last Edited: Wed Jan 25, 2017 10:40:27 AM www.miamidade.gov/building/pc-result_ app.asp?fldNOA= 19_0828.02&BasicSearch=Go&Classification=O%2CUnknown+%2F+Unselected%2C1 &appli. . . 1/1 MIAMI'!!' r&IBm'iiiJ/I DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION MIAMr-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami. Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.govfeconomy NOTICE OF ACCEPTANCE (NOA) DuPont De Nemours, Inc. 974 Centre Road, Chestnut Run Plaza 721-2246 Wilmington, DE 19805 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: DuPont'" Tyvck" ProTec'" 120, DuPont'''Tyvck~ ProTec'" 160, DuPonf"Tyvek® ProTcc"" 200. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no cbange in the applicable building code negatively affecting the performance oftbis product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NO A. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be avai lable for inspection at the job site at the request of the Building Official. This NOA revises NOA 19-0109.07 consists of pages I through 4. The submitted documentation was reviewed by Freddy Semina II NOA No.: 19-0828.02 Expiration Date: 01123/25 Approval Datc: 01123/20 Page 1 of 4 ROOFING COMPONENT ApPROVAL Category: Roofing Underlayment Polypropylene Sub-Category: Material: SCOPE: This approves DuPont'" Tyvek® ProTec'" 120, Dul'ont'" Tyvek" Pro'rec" 160, Dul'ont'" Tyvek" ProTec'" 200 as described in this Notice of Acceptance; designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY ApPLICANT: Test Product Product Dimensions S(!ecification Descri(!tion DuPon!'" Tyvek" 48" x 250' rolls ASTM 0226 Type Woven synthetic polymer underlayment with two ProTec'" 120 26 lbs. per roll I & II sides coated with UV protected and slip resistant polymer stabilized polypropylene on both sides. ~ Duf'ont'" Tyvek" 48" x 250' rolls ASTM 0226 Type Woven synthetic polymer underlayment with two ProTecT'" 160 32 lbs. per roll I & II sides coated with UV protected and slip resistant polymer stabilized polypropylene on both sides. Duf'ont" Tyvek'" 48" x 250' rolls ASTM 0226 Type Woven synthetic polymer underlayment with two ProTecT>! 200 35 lbs. per roll I & II sides coated with UV protected and slip resistant polymer stabilized polypropylene on both sides. MANUFACTURING LOCATION: 1. Qindao, China EVIDENCE SUBMITTED: Test Agencv Intertek Testing Services Test Identifier 101 866009COQ-002A 10 1866009COQ-OO I 4j-OPBS-19-ssudl-0 I.A Test NamelReport Physical Properties ASTM 0226 ASTM 0 226 Date 11119/14 11117/14 09/16/19 Nemo/etc. NOA No.: 19-0828.02 Expiration Date: 01/23/25 Approval Date: 01123120 Page 2 of 4 INSTALLA nON SPECIFICA nONS: (Single Layer: Slopes of 2:12 or greater) DuPonf"Tyvek® Pro Tee' .•• 120, DuPone"Tyvek® ProTec'" 160, DUPont"'Tyvek® ProTec'" 200 Roof Underlayment 1. DuPont''' Tyvek'" ProTecn, 120, DuPontTl" Tyvek® ProTecn, 160, Dul'ont'" Tyvek" ProTecn, 200 Roof Underlayments shall be installed in strict compliance with applicable Building Code. 2. DuPont''' Tyvek" ProTec™ 120, Dul'ont'" Tyvek~ ProTecTh' 160, DuPont'" Tyvek" ProTecT" 200 Roof Underlayments shall be installed with a minimum 4-inch horizontal lap and 6-inch vertical laps in a shingle layer fashion. Vertical laps in a succeeding course shall be staggered from those in preceding course by minimum 6-feet. 3. Dul'ont't'Tyvek" ProTecn, 120, Dul'ont't' Tyvek" ProTec™ 160, Dul'ont" Tyvek'" ProTecn, 200 Roof Underlayments shall be fastened with approved roofing nails and tin-caps spaced 6" o.c. at all laps and three staggered rows fastened 12" o.c. in the field of the roll. 4. Dul'ont't'Tyvek" ProTecT>' 120, Dul'ont'tTyvek" Pro'Tec" 160, Dul'ont'" Tyvek" ProTec'" 200 Roof Underlayments may be used with Asphaltic shingles, Wood shakes and shingles, Non-structural metal roofing, and quarry slate. 5. For fire classification of specific roof assemblies using Dul-ont" Tyvek" ProTec™ 120, DuPont'" Tyvek" ProTecn! 160, Dul'ont" Tyvek" ProTec'" 200 Roof Underlayments refer to a current Approved Roofing Materials Directory for fire ratings of this product. BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this material. LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. Dul'ont" Tyvek® ProTec'" 120, DuPone-" Tyvek'" ProTecT" 160, Dul'ont'" Tyvek" ProTecT." 200 Roof Underlayments shall be applied to a smooth, clean and dry surface with deck free of irregularities. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. 4. Dul'ont" Tyvek" ProTecT" 120, DuPont''' Tyvek" ProTecn, 160, Dul'ont'I'Tyvek" ProTecn, 200 Roof Underiayments shall not be hot mopped, refer to manufacturer's published literature for product compatibility. 5. DuPont""TyvekJ) ProTecn, 120, DuPontn, Tyvek" Pro'Fec'" 160, DuPontn, Tyvek" Pro'Tec'" 200 Roof Underlayments shall not be applied over an existing roof membrane as a recover system. 6. DuPont'''Tyvek® ProTecn, 120, DuPont'"Tyvek ProTecn, 160, Dul'ont't'Tyvek" ProTec™ 200 Roof Underlayments shall not be left exposed as a temporary roof for longer than 30 days of application. NOA No.: 19-0828.02 Expiration Date: 01123/25 Approval Date: 01123/20 Page 3 of 4 7. Dul'ont't'Tyvek" Pro'Iec'" 120, Dul'ont't'Tyvek" ProTecT>< 160, Dul'ont't'Tyvek" ProTecn, 200 Roof Underlayments are components used in roof system assemblies. Roof system assemblies are approved under a specific Notice of Acceptance. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. 8. Dul'ont't'Tyvek" ProTecn, 120, DuPont™Tyvekil ProTecn, 160, Dul'ont't'Tyvek" ProTecT>< 200 Roof Underlayrnents may be used with any approved roof covering Notice of Acceptance listing Dul'ont't'Tyvek" ProTecT>' 120, DuPont'" Tyvek ProTec'M 160, DuPont'" Tyvek'" Pro'Tec'" 200 RoofUnderlayments as a component part of an assembly in the Notice of Acceptance. If DuPont'M Tyvek" ProTec n. 120, DuPont''' Tyvek® ProTec'>I 160, DuPont'" Tyvek" ProTecn, 200 RoofUnderiayments are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami-Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. 9. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 10. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city, state and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. ''f'' •..• _ DuPont- Tyvek· Protec- 120 ROOfiNG UIlOfRLI\VMfHT f t<>us,<ouChep 'Ioil ,fb.te p.,. led! •••.• ,GeI' n. 't'ldIf"'J I f.J "' • 78,2 _ tu.a ..., (".2 ••• ".2 Ui tt.2 ••• ,,11 DuPont- Tyvek· Prote,,' 160 ROOf N.(ill OntLAYl.I!.IIT '_"coucllopo.<l1 \/b~sep a'e 4i~ II 2~.' (10 .,u_.' I ,.2 In II " •• 1 _ I').z.' -"1 ( .•. :z. _., 'D.~ iii ta2,. rNrJ DuPont' Tyvew ProtecM 200 ROOflS!; lJNDCRlAYMCIIT I !OUNO CJlQ4llrtoit l'aSi) P8l81f!c.h~ "Ij." ~ l~' 111) ~~iiar .•• " t.2 '" •. ),4.2 •• In. I.,. • ., ll.~ ••• ICl'G..lI '" ceu ••• " END OF THIS ACCEPTANCE NOA No.: 19-0828,02 Expiration Date: 01123/25 Approval Date: 01123120 Page 4 of 4