Loading...
HomeMy WebLinkAboutReview CommentsPlanning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 PROPERTY INFORMATION Address: 5801 Eastwood Dr City I State I Zip: Fort Pierce, FI 34951 Parcel#: 1301-613-0042-000/5 Zoning: RS-4 REVIEW COMMENTS Owner(s): Wjh LIc I Wjhfl Llc Jurisdiction: SAINT LUCIE COUNTY Lot#: 7 Block: 138 1 APPLICATION INFORMATION Permit Number: 1910-0658 Stories: Automatic Sprinkler System? No Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS) CONTRACTOR INFORMATION Contractor Name: Wade G Jurney Fax Number: 336-282-3606 Business Name: Wade Jurney Homes -Email: Karen.Donofdo@Wadejurne Business Addr: 3198 Aerial Way yhomes.Com; Dmurra ry@ Wadej urneyhom es.Com City I State I Zip: Brookville, FI 34604 REVIEWS AND COMMENTS Review Type Status Reviewed By Date Started Date Completed Date Released ADDRESSING ASSIGNMENT COMPLETE Lori Bender 11/1/2019 11/412019 11/412019 Comment: DOCUMENTS MISSING PENDING Karen Nielsen 1012912019 10/29/2019 Comment: DRIVE -WAY PERMIT SENT TO ROAD & BRIDGE. 10/31/2019 Comment: VEGGIE PERMIT UNDER W FOR WJH ENVIRONMENTAL REVIEW COMPLETE Lynn Swartzel 10/3012019 10/31/2019 1013112019 Comment: FRONT COUNTER REVIEW COMPLETE Karen Nielsen 1012912019 10129/2019 1012912019 Comment: PLANS EXAMINER REVIEW INCOMPLETE Jpi, Inc -Andrew 11/19/2019 Comment: 1) ENERGY CALCULATIONS- A) PROJECT NAME, ADDRESS & LOT NUMBER IS INCORRECT. 11/19/2019 B) NUMBER OF BEDROOMS INCORRECT. C) CONCRETE BLOCK WALL TYPE LISTED Comment: 2) TRUSS ENGINEERING WILL NEED TO BE STAMPED REVIEWED & APPROVED BY THE HOUSE DESIGNER 11/19/2019 (ENGINEER OF RECORD). ([A) 107.3.4.1 ) Comment: 3) PLUMBING & ELECTRICAL DRAWINGS IN ENGINEER'S TITLE BLOCK WILL NEED TO BE SIGNED & 11/19/2019 SEALED. (FAC 61 G15-23.003(1)) Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 REVIEW COMMENTS L, Comment: 4) HEAT LOADS- 11/19/2019 A) DESIGN LOCATION IS INCORRECT (R403.7.1) B) INCORRECT LEGAL DESCRIPTION UNDER JOB HEADING. Comment: 5) PRODUCT APPROVAL SCHEDULE 11/19/2019 A) FL4334.1 NO RECORD B) F1-4904.6 NO RECORD ([A] 107.2.1) 11/19/2019 Comment: 6) PROVIDE PRODUCT APPROVAL FOR OFF RIDGE ROOF VENT. ([A] 107.2.1) 1111912019 Comment: 7) PLEASE PROVIDE GEOTECHNICAL REPORT. ([Al 107.2.1) 11119/2019 Comment: 8) PROVIDE DESIGN REQUIREMENTS FOR FILL. (R401.2) ZONING REVIEW INCOMPLETE Lydia Galbraith 1013112019 Comment: THE SURVEY IS INCOMPLETE. PLEASE INDICATE ON THE SURVEY: - ELEVATION OF CROWN OF THE ROAD. - REAR SETBACK 10/31/2019 12/20/19 RECEIVED CORRECTED SURVEYS. THEY ARE TOTALLY MIXED UP WITH LOT 6 1116120 RECEIVED UPDATED SURVEYS. SURVEY HAS NOW CORRECT LOT AND LEGAL. HOWEVER, THE SURVEYOR ADDED A WRONG PARCEL ID. PARCEL ID IS 1301-613-0042-000/5. 10/31/2019 Comment: PLEASE PROVIDE 2 UPDATED SIGNED AND SEALED SURVEYS WITH ABOVE COMMENTS CORRECTED. Comment: THE SURVEYS STAMPED BY THE HEALTH DEP. ARE DONE BY GSS SURVEYING AND MAPPING LLC. WITH PROPOSED FFE OF 24.70. 1/16/2020 THE CORRECTED SURVEYS (WHICH STILL HAVE DISCREPANCY) ARE FROM H & H SURVEY CONSULTANTS WITH PROPOSED FFE OF 23.10'. WHICH PROPOSED FFE IS GOING TO BE USED? WHY IS THE CORRECTED SURVEY FROM A DIFFERENT SURVEYOR?