HomeMy WebLinkAboutBUILDING INPUT SUMMARYBuilding Input Summary Report
PROJECT
Title:Address type:Miranda Residence v2 S
Building Type:Bedrooms:Lot #:User 5
Owner:Conditioned Area:Block/SubDivision:Joseph Miranda 6481
Total Stories:PlatBook:3
Builder Name:Worst Case:Street:Joseph Miranda No 7916 South Ocean Drive
Permit Office:Rotate Angle:County:St. Lucie - Code Compliance 0 Martin
Jurisdiction:Cross Ventilation:City, State, Zip:St. Lucie County Jensen Beach,
Family Type:Whole House Fan: Single-family FL, 34957
New/Existing:Terrain: New (From Plans)Suburban
Year Construct:Shielding: 2018 Suburban
Comment:
CLIMATE
Design Design Temp Int Design Temp Heating Design Daily temp
Location Tmy Site 97.5%2.5%Winter Summer Degree Days Moisture Range
___ FL, Fort Pierce FL_VERO_BEACH_MUNICIPA 39 90 70 75 299 62 Low
UTILITY
Fuel Unit Utility Name Monthly Fixed Cost $/Unit
___ Electricity kWh EnergyGauge Default 0.00 0.13
___ Natural Gas Therm EnergyGauge Default 0.00 1.05
___ Fuel Oil Gallon EnergyGauge Default 0.00 1.10
___ Propane Gallon EnergyGauge Default 0.00 1.40
SURROUNDINGS
------------Shade Trees------------------------Adjacent Buildings----------
Ornt Type Height Width Distance Exist Height Width Distance
N None 0 ft 0 ft 0 ft 0 ft 0 ft 0 ft
NE None 0 ft 0 ft 0 ft 0 ft 0 ft 0 ft
E None 0 ft 0 ft 0 ft 0 ft 0 ft 0 ft
SE None 0 ft 0 ft 0 ft 0 ft 0 ft 0 ft
S None 0 ft 0 ft 0 ft 0 ft 0 ft 0 ft
SW None 0 ft 0 ft 0 ft 0 ft 0 ft 0 ft
W None 0 ft 0 ft 0 ft 0 ft 0 ft 0 ft
NW None 0 ft 0 ft 0 ft 0 ft 0 ft 0 ft
BLOCKS
Number Name Area Volume
___ 1 Block1 1022 12264
___ 2 Block2 1151 15538.5
___ 3 Block3 1609 21721.5
___ 4 Block4 269927880.669921875
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated
___ 1 Garage Floor 1022 12264 No 2 1 Yes Yes Yes
___ 2 1st Floor A 1151 15538.5 Yes 3 0 Yes Yes Yes
___ 3 1st Floor B 1609 21721.5 No 2 1 Yes Yes Yes
___ 4 2nd Floor 2699 27880.67 No 4 3 Yes Yes Yes
3/13/2020 2:53:22 PM EnergyGauge® / USRCZB v6.1.04 Page 1
Building Input Summary Report
FLOORS (Total Exposed Area = 3920 sq.ft.)
#Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet
___ 1 Slab-On-Grade Edge Ins Garage Floor 32 0 1022 ft 0.304 ---0.00 0.00 1.00
___ 2 Floor over Garage 1st Floor A ------1740 ft 0.193 0 0.00 0.00 1.00
___ 3 Floor Over Other Space 1st Floor B ------1020 ft 0.195 0.00 0.00 1.00
___ 4 Raised Floor 2nd Floor ------1158 ft 0.212 0 0.00 0.00 1.00
___ 5 Floor Over Other Space 2nd Floor ------800 ft 0.195 0.00 0.00 1.00
___ 6 Floor Over Other Space 2nd Floor ------741 ft 0.195 0.00 0.00 1.00
ROOF
Roof Gable Roof SolarRad SA Emitt Emitt Deck Pitch
#Type Materials Area Area Color Absor.Barr Tested Tested Insul.(deg)
___ 1 Hip Metal 3018 ft²0 ft²Medium N 0.6 No 0.9 No 20 26.6
ATTIC
#Type Ventilation Vent Ratio (1 in)Area RBS IRCC
___ 1 Full attic Unvented 0 2699 ft²N N
CEILING (Total Exposed Area = 6481 sq.ft.)
#Ceiling Type Space R-Value Ins. Type Area U-Factor Framing Frac.Truss Type
___ 1 Under Attic(Unvented)Garage Floor 0.0 Blown 1022.0ft²0.039 0.11 Wood
___ 2 Under Attic(Unvented)1st Floor A 0.0 Blown 1151.0ft²0.039 0.11 Wood
___ 3 Under Attic(Unvented)1st Floor B 0.0 Blown 1609.0ft²0.039 0.11 Wood
___ 4 Under Attic(Unvented)2nd Floor 0.0 Blown 2699.0ft²0.039 0.11 Wood
WALLS (Total Exposed Area = 8855 sq.ft.)
Adjacent Cavity Width Height Area U-Sheath Frm.Solar Below
#Ornt To Wall Type Space R-Value Ft In Ft In sq.ft.Factor R-Value Frac.Absor.Grade
___ 1 N Garage Frame - Wood Garage Floor 13.0 22.0 4 12.0 0 268.0 0.084 0.23 0.30 0 %
___ 2 W Garage Frame - Wood 2nd Floor 13.0 5.0 8 12.0 0 68.0 0.084 0.23 0.30 0 %
___ 3 N Garage Frame - Wood 2nd Floor 13.0 9.0 4 12.0 0 112.0 0.084 0.23 0.30 0 %
___ 4 E Exterior Frame - Wood 2nd Floor 13.0 14.0 9 12.0 0 177.0 0.084 0.23 0.30 0 %
___ 5 S Exterior Frame - Wood 2nd Floor 13.0 9.0 0 12.0 0 108.0 0.084 0.23 0.30 0 %
___ 6 W Exterior Frame - Wood 2nd Floor 13.0 12.0 9 12.0 0 153.0 0.084 0.23 0.30 0 %
___ 7 N Exterior Frame - Wood 2nd Floor 13.0 6.0 4 12.0 0 76.0 0.084 0.23 0.30 0 %
___ 8 W Exterior Frame - Wood 2nd Floor 13.0 6.0 0 12.0 0 72.0 0.084 0.23 0.30 0 %
___ 9 N Exterior Frame - Wood 2nd Floor 13.0 6.0 6 12.0 0 78.0 0.084 0.23 0.30 0 %
___ 10 E Exterior Frame - Wood 2nd Floor 13.0 6.0 8 12.0 0 80.0 0.084 0.23 0.30 0 %
___ 11 N Exterior Frame - Wood 2nd Floor 13.0 2.0 2 12.0 0 26.0 0.084 0.23 0.30 0 %
___ 12 E Exterior Frame - Wood 2nd Floor 13.0 10.0 8 12.0 0 128.0 0.084 0.23 0.30 0 %
___ 13 S Exterior Conc. Blk - Int Ins 2nd Floor 4.1 31.0 9 12.0 0 381.0 0.149 0 0.30 0 %
___ 14 W Exterior Conc. Blk - Int Ins 2nd Floor 4.1 14.0 8 12.0 0 176.0 0.149 0 0.30 0 %
___ 15 S Exterior Conc. Blk - Int Ins 2nd Floor 4.1 7.0 4 12.0 0 88.0 0.149 0 0.30 0 %
___ 16 W Exterior Conc. Blk - Int Ins 2nd Floor 4.1 8.0 4 12.0 0 100.0 0.149 0 0.30 0 %
___ 17 N Exterior Conc. Blk - Int Ins 1st Floor A 4.1 45.0 0 13.0 6 607.5 0.149 0 0.30 0 %
___ 18 E Exterior Conc. Blk - Int Ins 1st Floor A 4.1 20.0 0 13.0 6 270.0 0.149 0 0.30 0 %
___ 19 S Exterior Conc. Blk - Int Ins 1st Floor A 4.1 7.0 8 13.0 6 103.5 0.149 0 0.30 0 %
___ 20 E Exterior Conc. Blk - Int Ins 1st Floor B 4.1 20.0 8 13.0 6 279.0 0.149 0 0.30 0 %
___ 21 N Exterior Conc. Blk - Int Ins 1st Floor B 4.1 16.0 4 13.0 6 220.5 0.149 0 0.30 0 %
___ 22 E Exterior Conc. Blk - Int Ins 1st Floor B 4.1 17.0 4 13.0 6 234.0 0.149 0 0.30 0 %
___ 23 S Exterior Conc. Blk - Int Ins 1st Floor B 4.1 55.0 0 13.0 6 742.5 0.149 0 0.30 0 %
___ 24 W Exterior Conc. Blk - Int Ins 1st Floor B 4.1 14.0 8 13.0 6 198.0 0.149 0 0.30 0 %
3/13/2020 2:53:22 PM EnergyGauge® / USRCZB v6.1.04 Page 2
Building Input Summary Report
WALLS(Continued)
___ 25 S Exterior Conc. Blk - Int Ins 1st Floor B 4.1 7.0 4 13.0 6 99.0 0.148 0 0.30 0 %
___ 26 W Exterior Conc. Blk - Int Ins 1st Floor B 4.1 21.0 10 13.0 6 294.8 0.149 0 0.30 0 %
___ 27 S Exterior Conc. Blk - Int Ins 1st Floor A 4.1 7.0 0 13.0 6 94.5 0.149 0 0.30 0 %
___ 28 W Exterior Conc. Blk - Int Ins 1st Floor A 4.1 15.0 6 13.0 6 209.3 0.149 0 0.30 0 %
___ 29 N Exterior Conc. Blk - Int Ins 1st Floor A 4.1 15.0 0 13.0 6 202.5 0.149 0 0.30 0 %
___ 30 W Exterior Conc. Blk - Int Ins 1st Floor A 4.1 6.0 0 13.0 6 81.0 0.149 0 0.30 0 %
___ 31 N Exterior Conc. Blk - Int Ins 2nd Floor 4.1 27.0 10 10.0 4 287.6 0.149 0 0.30 0 %
___ 32 W Exterior Conc. Blk - Int Ins 2nd Floor 4.1 2.0 0 10.0 4 20.7 0.149 0 0.30 0 %
___ 33 N Exterior Conc. Blk - Int Ins 2nd Floor 4.1 8.0 8 10.0 4 89.6 0.149 0 0.30 0 %
___ 34 E Exterior Conc. Blk - Int Ins 2nd Floor 4.1 2.0 0 10.0 4 20.7 0.149 0 0.30 0 %
___ 35 N Exterior Conc. Blk - Int Ins 2nd Floor 4.1 22.0 2 10.0 4 229.1 0.149 0 0.30 0 %
___ 36 E Exterior Conc. Blk - Int Ins 2nd Floor 4.1 20.0 0 10.0 4 206.7 0.149 0 0.30 0 %
___ 37 S Exterior Conc. Blk - Int Ins 2nd Floor 4.1 21.0 4 10.0 4 220.4 0.149 0 0.30 0 %
___ 38 E Exterior Conc. Blk - Int Ins 2nd Floor 4.1 5.0 4 10.0 4 55.1 0.149 0 0.30 0 %
___ 39 S Exterior Conc. Blk - Int Ins 2nd Floor 4.1 7.0 4 10.0 4 75.8 0.149 0 0.30 0 %
___ 40 E Exterior Conc. Blk - Int Ins 2nd Floor 4.1 10.0 0 10.0 4 103.3 0.149 0 0.30 0 %
___ 41 N Exterior Conc. Blk - Int Ins 2nd Floor 4.1 7.0 4 10.0 4 75.8 0.149 0 0.30 0 %
___ 42 E Exterior Conc. Blk - Int Ins 2nd Floor 4.1 5.0 4 10.0 4 55.1 0.149 0 0.30 0 %
___ 43 N Exterior Conc. Blk - Int Ins 2nd Floor 4.1 10.0 4 10.0 4 106.8 0.149 0 0.30 0 %
___ 44 W Exterior Conc. Blk - Int Ins 2nd Floor 4.1 17.0 4 10.0 4 179.1 0.149 0 0.30 0 %
___ 45 S Exterior Conc. Blk - Int Ins 2nd Floor 4.1 38.0 4 10.0 4 396.1 0.149 0 0.30 0 %
___ 46 W Exterior Conc. Blk - Int Ins 2nd Floor 4.1 14.0 8 10.0 4 151.6 0.149 0 0.30 0 %
___ 47 S Exterior Conc. Blk - Int Ins 2nd Floor 4.1 17.0 4 10.0 4 179.1 0.149 0 0.30 0 %
___ 48 W Exterior Conc. Blk - Int Ins 2nd Floor 4.1 21.0 10 10.0 4 225.6 0.149 0 0.30 0 %
___ 49 S Exterior Conc. Blk - Int Ins 2nd Floor 4.1 7.0 0 10.0 4 72.3 0.149 0 0.30 0 %
___ 50 W Exterior Conc. Blk - Int Ins 2nd Floor 4.1 15.0 6 10.0 4 160.2 0.149 0 0.30 0 %
___ 51 N Exterior Conc. Blk - Int Ins 2nd Floor 4.1 15.0 0 10.0 4 155.0 0.149 0 0.30 0 %
___ 52 SW Exterior Conc. Blk - Int Ins 2nd Floor 4.1 6.0 0 10.0 4 62.0 0.149 0 0.30 0 %
DOORS (Total Exposed Area = 132 sq.ft.)
Width Height
# Ornt Adjacent To Door Type Space Storms U-Value Ft In Ft In Area
___ 1 N Garage Wood Garage Floor None 0.46 3.00 0 8.00 0 24.0ft²
___ 2 S Exterior Wood 2nd Floor None 0.46 2.00 8 8.00 0 21.3ft²
___ 3 E Exterior Wood 2nd Floor None 0.46 2.00 6 8.00 0 20.0ft²
___ 4 W Exterior Wood 2nd Floor None 0.46 3.00 4 8.00 0 26.7ft²
___ 5 E Exterior Wood 1st Floor A None 0.46 2.00 6 8.00 0 20.0ft²
___ 6 W Exterior Wood 1st Floor A None 0.46 2.00 6 8.00 0 20.0ft²
WINDOWS (Total Exposed Area = 1761 sq.ft.)
Wall -----Overhang-----
# Ornt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation Interior Shade Screening
___ 1 S 13 Metal Low-E Single Yes 0.99 0.22 N N 12.5ft² 0.0 ft 0 in 0.0 ft 0 in None None
___ 2 W 14 Metal Low-E Single Yes 0.99 0.22 N N 27.5ft² 0.0 ft 0 in 0.0 ft 0 in None None
___ 3 W 16 Metal Low-E Single Yes 0.99 0.22 N N 32.0ft² 0.0 ft 0 in 0.0 ft 0 in None None
___ 4 N 17 Metal Low-E Single Yes 0.99 0.22 N N 11.3ft² 0.0 ft 0 in 0.0 ft 0 in None None
___ 5 N 17 Metal Low-E Single Yes 0.99 0.22 N N 25.0ft² 0.0 ft 0 in 0.0 ft 0 in None None
___ 6 N 17 Metal Low-E Single Yes 0.99 0.22 N N 10.0ft² 0.0 ft 0 in 0.0 ft 0 in None None
___ 7 E 18 Metal Low-E Single Yes 1.11 0.27 N N 120.0ft² 0.0 ft 0 in 0.0 ft 0 in None None
___ 8 S 19 Metal Low-E Single Yes 0.99 0.22 N N 33.0ft² 0.0 ft 0 in 0.0 ft 0 in None None
___ 9 E 20 Metal Low-E Single Yes 1.11 0.27 N N 200.0ft² 0.0 ft 0 in 0.0 ft 0 in None None
___ 10N 21 Metal Low-E Single Yes 0.99 0.22 N N 50.0ft² 0.0 ft 0 in 0.0 ft 0 in None None
___ 11E 22 Metal Low-E Single Yes 1.11 0.27 N N 150.0ft² 0.0 ft 0 in 0.0 ft 0 in None None
___ 12S 23 Metal Low-E Single Yes 0.99 0.22 N N 50.0ft² 0.0 ft 0 in 0.0 ft 0 in None None
___ 13S 23 Metal Low-E Single Yes 0.99 0.22 N N 12.5ft² 0.0 ft 0 in 0.0 ft 0 in None None
___ 14W 24 Metal Low-E Single Yes 1.11 0.27 N N 80.0ft² 0.0 ft 0 in 0.0 ft 0 in None None
___ 15W 26 Metal Low-E Single Yes 0.99 0.22 N N 122.5ft² 0.0 ft 0 in 0.0 ft 0 in None None
3/13/2020 2:53:22 PM EnergyGauge® / USRCZB v6.1.04 Page 3
Building Input Summary Report
WINDOWS(Continued)
___ 16W 28 Metal Low-E Single Yes 0.99 0.22 N N 80.0ft²0.0 ft 0 in 0.0 ft 0 in None None
___ 17N 31 Metal Low-E Single Yes 0.99 0.22 N N 14.7ft²0.0 ft 0 in 0.0 ft 0 in None None
___ 18N 33 Metal Low-E Single Yes 0.99 0.22 N N 22.5ft²0.0 ft 0 in 0.0 ft 0 in None None
___ 19E 36 Metal Low-E Single Yes 1.11 0.27 N N 135.0ft²0.0 ft 0 in 0.0 ft 0 in None None
___ 20S 37 Metal Low-E Single Yes 0.99 0.22 N N 36.0ft²0.0 ft 0 in 0.0 ft 0 in None None
___ 21E 38 Metal Low-E Single Yes 0.99 0.22 N N 24.0ft²0.0 ft 0 in 0.0 ft 0 in None None
___ 22E 40 Metal Low-E Single Yes 0.99 0.22 N N 90.0ft²0.0 ft 0 in 0.0 ft 0 in None None
___ 23E 42 Metal Low-E Single Yes 0.99 0.22 N N 24.0ft²0.0 ft 0 in 0.0 ft 0 in None None
___ 24N 43 Metal Low-E Single Yes 0.99 0.22 N N 15.0ft²0.0 ft 0 in 0.0 ft 0 in None None
___ 25W 44 Metal Low-E Single Yes 1.11 0.27 N N 108.0ft²0.0 ft 0 in 0.0 ft 0 in None None
___ 26S 45 Metal Low-E Single Yes 0.40 0.25 N N 15.0ft²0.0 ft 0 in 0.0 ft 0 in None None
___ 27S 45 Metal Low-E Single Yes 0.40 0.25 N N 30.0ft²0.0 ft 0 in 0.0 ft 0 in None None
___ 28W 46 Metal Low-E Single Yes 0.40 0.25 N N 13.8ft²0.0 ft 0 in 0.0 ft 0 in None None
___ 29W 48 Metal Low-E Single Yes 0.40 0.25 N N 135.0ft²0.0 ft 0 in 0.0 ft 0 in None None
___ 30W 50 Metal Low-E Single Yes 0.40 0.25 N N 72.0ft²0.0 ft 0 in 0.0 ft 0 in None None
___ 31SW 52 Metal Low-E Single Yes 0.40 0.25 N N 10.0ft²0.0 ft 0 in 0.0 ft 0 in None None
INFILTRATION
#Scope Method SLA CFM50 ELA EqLA ACH ACH50 Space(s)
___ 1 Wholehouse Proposed ACH(50)0.00046 7740 424.94 799.16 0.2874 6.0 All
GARAGE
#Floor Area Roof Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
___ 1 2436 ft²2436 ft²232 ft 12 ft 1
MASS
#Mass Type Area Thickness Furniture Fraction Space
___ 1 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 Garage Floor
___ 2 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 1st Floor A
___ 3 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 1st Floor B
___ 4 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 2nd Floor
HEATING SYSTEM
#System Type Subtype/Speed AHRI #Efficiency Capacity ----Geothermal HeatPump----Ducts Block
kBtu/hr Entry Power Volt Current
___ 1 Electric Heat Pump Split/Single HSPF: 8.60 30.0 0.00 0.00 0.00 sys#1 1
___ 2 Electric Heat Pump Split/Single HSPF: 8.60 36.0 0.00 0.00 0.00 sys#2 2
___ 3 Electric Heat Pump Split/Single HSPF: 8.60 36.0 0.00 0.00 0.00 sys#3 3
___ 4 Electric Heat Pump Split/Single HSPF: 8.60 60.0 0.00 0.00 0.00 sys#4 4
COOLING SYSTEM
#System Type Subtype/Speed AHRI #Efficiency Capacity Air Flow SHR Duct Block
kBtu/hr cfm
___ 1 Central Unit Split/Single SEER:14 30.0 900 0.70 sys#1 1
___ 2 Central Unit Split/Single SEER:14 36.0 1080 0.70 sys#2 2
___ 3 Central Unit Split/Single SEER:14 36.0 1080 0.70 sys#3 3
___ 4 Central Unit Split/Single SEER:14 60.0 1800 0.70 sys#4 4
3/13/2020 2:53:22 PM EnergyGauge® / USRCZB v6.1.04 Page 4
Building Input Summary Report
HOT WATER SYSTEM
#System Type Subtype Location EF(UEF)Cap Use SetPnt Fixture Flow Pipe Ins.Pipe length
___ 1 Electric None Garage 0.95 (0.93)40.00 gal 80 gal 120 deg Standard None 123
Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits
System Type length length power Connected Flow Eff
___ 1 No NA NA NA No NA NA NA None
DUCTS
Duct ---------Supply------------------Return---------Air CFM 25 CFM 25 HVAC #
#Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT QN RLF Heat Cool
___ 1 Attic 6.0 120 ft²Attic 6.0 81 ft²Default Leakage Garage (Default)(Default)1 1
___ 2 Attic 6.0 200 ft²Attic 6.0 81 ft²Prop. Leak Free 1st Floor ------0.03 0.50 2 2
___ 3 Attic 6.0 200 ft²Attic 6.0 81 ft²Prop. Leak Free 1st Floor ------0.03 0.50 3 3
___ 4 Attic 6.0 200 ft²Attic 6.0 81 ft²Prop. Leak Free 2nd Floor ------0.03 0.50 4 4
TEMPERATURES
Programable Thermostat: N Ceiling Fans: N
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jun [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
Heating [X] Jan [X] Feb [X] Mar [ ] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [ ] Oct [X] Nov [X] Dec
Venting [ ] Jan [ ] Feb [X] Mar [X] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [X] Oct [X] Nov [ ] Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
___ Cooling (WD)AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
___ Cooling (WEH)AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
___ Heating (WD)AM 68 68 68 68 68 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
___ Heating (WEH)AM 68 68 68 68 68 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
REFRIGERATORS
ID Type Screen Location Quantity Vol Frz. Vol Make Model Schedule kWhPerYr
___ 1 Default Refrigerator Default New 1st Floor A 1 26 5 HERS2011
CLOTHES WASHERS
ID Type Screen Location Capacity Make Model Schedule LoadsPerYr
___ 1 Cl washer Default New 1st Floor A 2.874 HERS2011 428
CLOTHES DRYERS
ID Type Screen Location Quantity Fuel Type Make Model Schedule kWhPerYr
___ 1 Dryer Default New 1st Floor A 2.874 Electricity HERS2011 428
3/13/2020 2:53:22 PM EnergyGauge® / USRCZB v6.1.04 Page 5
Building Input Summary Report
DISHWASHERS
ID Type Screen Location Capacity Vintage Make Model Schedule kWhPerYr
___ 1 Dishwasher 1 1st Default New 1st Floor A 12 2004 or Newer HERS2011 372
RANGE OVENS
ID Type Screen Location Type Fuel Type Make Model Cooktop Oven
___ 1 R a n g e O v e n Default New 1st Floor A Combo Elec Electric flat Not Convec
HARD WIRED LIGHTING
ID Type Screen Location Total#Quantity#Comp Fl All Other Fl Bulb Type Schedule Watts per bulb
___ 2 Hard-Wired By Count - Qualifying Exterior 4 4 HERS2011 60
___ 3 Hard-Wired By Count - Qualifying Garage 1 1 HERS2011 60
MISC ELECTRICAL LOADS
ID Type Screen Location Item Quantity Catagory Operating Schedule Off Standby
___ 1 Misc Elec Load Simple Default Main 1 1 HERS2011 1
APPLIANCES & LIGHTING SCHEDULES
Appliance Schedule:HERS2014 Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Occupancy p e a k :400 Btu AM 0.930 0.930 0.930 0.930 0.930 0.930 0.930 0.980 0.460 0.270 0.270 0.270
% Released:100 %PM 0.270 0.270 0.270 0.270 0.330 0.610 1.000 1.000 0.930 0.930 0.930 0.930
refrig p e a k :99 W AM 0.824 0.804 0.784 0.764 0.744 0.734 0.744 0.754 0.764 0.794 0.814 0.854
% Released:100 %PM 0.854 0.864 0.884 0.904 0.925 0.945 0.925 0.915 0.904 0.894 0.874 0.854
cWash p e a k :10 W AM 0.200 0.100 0.050 0.050 0.050 0.075 0.200 0.375 0.500 0.800 0.950 1.000
% Released:30 %PM 0.875 0.850 0.800 0.625 0.625 0.600 0.575 0.550 0.625 0.700 0.650 0.375
E-cDry p e a k :111 W AM 0.200 0.100 0.050 0.050 0.050 0.075 0.200 0.375 0.500 0.800 0.950 1.000
% Released:15 %PM 0.875 0.850 0.800 0.625 0.625 0.600 0.575 0.550 0.625 0.700 0.650 0.375
dWash p e a k :71 W AM 0.139 0.050 0.028 0.024 0.029 0.090 0.169 0.303 0.541 0.594 0.502 0.443
% Released:60 %PM 0.376 0.396 0.334 0.323 0.344 0.448 0.791 1.000 0.800 0.597 0.383 0.281
E-rOven p e a k :194 W AM 0.057 0.057 0.057 0.057 0.057 0.114 0.171 0.286 0.343 0.343 0.343 0.400
% Released:80 %PM 0.457 0.343 0.286 0.400 0.571 1.000 0.857 0.429 0.286 0.229 0.171 0.114
TVs p e a k :277 W AM 0.100 0.050 0.050 0.050 0.100 0.200 0.400 0.450 0.400 0.200 0.100 0.100
% Released:100 %PM 0.050 0.050 0.150 0.450 0.850 1.000 0.950 0.800 0.500 0.250 0.150 0.100
cFan p e a k :0 W AM 0.600 0.600 0.600 0.600 0.600 0.600 0.600 0.250 0.250 0.250 0.250 0.250
% Released:100 %PM 0.250 0.250 0.250 0.250 0.250 0.250 0.550 0.600 0.600 0.600 0.600 0.600
lgts-in p e a k :1822 W AM 0.160 0.150 0.160 0.180 0.230 0.450 0.420 0.260 0.190 0.160 0.120 0.110
% Released:100 %PM 0.160 0.170 0.250 0.270 0.340 0.550 0.600 0.880 1.000 0.880 0.510 0.280
lgts-out p e a k :113 W AM 1.000 1.000 1.000 1.000 1.000 0.750 0.750 0.000 0.000 0.000 0.000 0.000
% Released:0 %PM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.500 0.750 0.750 0.750 1.000
lgts-gar p e a k :37 W AM 0.000 0.000 0.000 0.000 0.000 0.500 0.750 1.000 0.750 0.500 0.000 0.000
% Released:0 %PM 0.000 0.000 0.500 0.500 0.750 1.000 0.750 0.500 0.000 0.000 0.000 0.000
3/13/2020 2:53:22 PM EnergyGauge® / USRCZB v6.1.04 Page 6
Building Input Summary Report
APPLIANCES & LIGHTING SCHEDULES(Continued)
MEL p e a k :0 W AM 0.500 0.500 0.500 0.750 0.750 0.850 1.000 1.000 1.000 1.000 0.900 0.900
% Released:90 %PM 0.900 0.900 1.000 1.000 1.000 1.000 1.000 1.000 1.000 0.850 0.750 0.750
3/13/2020 2:53:22 PM EnergyGauge® / USRCZB v6.1.04 Page 7