Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFILE COPY FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Miranda Residence Builder Name: Joseph Miranda Street: 7916 South Ocean Drive Permit Office: St. Lucie - Code Compliance City, State, Zip: Jensen Beach , FL, 34957 Permit Number:1904-0630 Owner: Joseph Miranda Jurisdiction: St. ducie County Design Location: FL, Fort Pierce County: Martin (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (8854I6 sqft.) Insulation Area a. Concrete Block- Int Insul, Exterior � R=5.0 7508.60 ft' 2. Single family or multiple family Single-family b. Frame - Wood, Fxterior R=13.0 898.00 ft' 3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=13.0 448.00 ft' 4. Number of Bedrooms 5 d. N/A R= ft' 10. Ceiling Types (64181.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 6481.00 ft' 6. Conditioned floor area above grade (ft') 6481 b. N/A R= ft' Conditioned floor area below grade (ft') 0 c. N/A R= ft' 11. Ducts R ft' 7. Windows(1748.2 sqft.) Description Area 2 additional duct s stem(s) 6 120 a. U-Factor: Sgl, U=0.40 1748.20 ft' b. Sup: Attic, Ret: Attic, AH: 1st Floor A Sup: Attic, Ret: Attic, AH: 1st Floor A 6 200 detail SHGC: SHGC=0.25 c. (see b. U-Factor: N/A ft' 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 30.0 SEER:14.00 b. Central Unit 36.0 SEER:14.00 c. U-Factor: N/A ft' 2 additional cooling systems (see details) SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Heat Pump 30.0 HSPF:8.60 SHGC: b. Electric Heat Pump 36.0 HSPF:8.60 Area Weighted Average Overhang Depth: 0.000 ft. 2 additional heating systems (see details) Area Weighted Average SHGC: 0.250 14. Hot water systems a. Natural Gas Cap: 40 gallonsEF: 8. Floor Types (6481.0 sqft.) Insulation Area 0.590 a. Floor Over Other Space R=0.0- 2561.00 ft' b. Conservation features b. Floor over Garage R=0.0 1740.00 ft' None c. other (see details) R= 2180.00 ft' 15. Credits None Glass/Floor Area: 0.270 Total Proposed Modified Loads: 231.58 PASS Total Baseline Loads: 240.74 1 hereby certify that the plans and specifications covered by Review of the plans and STgrB this calculation are in compliance with the Florida Energy specifications covered by this O�11f%tE a p Code. // Rater ID: 1490 SJe, calculation indicates compliance with the Florida Energy � un,,:, '�. •: � '"•;..� O PREPARED BY: DATE: 04/29/2019 lCode. Before construction is completed this building will be inspected for compliance with Section 553.908 „ r I herebycertify th this buildi fy g, as d ' n , is in compliance Florida Statutes. with the Florida nergy Code COD WB / OWNER/AGE BUILDING OFFICIAL. DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air hani certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report cc tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.025 Qn for whole enclosure qualifies as ith R402.4.1.1 and this project requires an .2). Arming d� leak fors, ouse. Py 4/29/2019 6:59 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 7 rnRnn PAnz;_*:)n17 . ' INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Miranda Residence Bedrooms: 5 Address Type: Street Address Building Type: User Conditioned Area: 6481 Lot # Owner Name: Joseph Miranda Total Stories: 3 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Joseph Miranda Rotate Angle: 0 Street: 7916 South Ocean Driv Permit Office: St. Lucie - Code Compliance Cross Ventilation: County: Martin Jurisdiction: St. Lucie County Whole House Fan: City, State, Zip: Jensen Beach, Family Type: Single-family FL, 34957 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 1022 12264 2 Block2 1151 15538.5 3 Block3 1609 21721.5 4 Block4 2699 27880.7 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfillD Finished Cooled Heated 1 Garage Floor 1022 12264 No 2 1 1 Yes Yes Yes 2 1 st Floor A 1151 15538.5 Yes 3 0 1 Yes Yes Yes 3 1st Floor B 1609 21721.5 No 2 1 1 Yes Yes Yes 4 2nd Floor 2699 27880.7 No 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Garage Floor 32 ft 0 1022 ftz ____ 0 0 1 2 Floor over Garage 1 st Floor A ___- _--_ 1740 ftZ 0 0 0 1 3 Floor Over Other Space 1 st Floor B 1020 ftZ 0 0 0 1 4 Raised Floor 2nd Floor ___ e__ 1158 ft' 0 0 0 1 5 Floor Over Other Space 2nd Floor 800 ft' 0 0 0 1 6 Floor Over Other Space 2nd Floor ____ e 741 ftZ 0 0 0 1 4/29/2019 6:59 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY GHF=GKL15T REPUK 1 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 3018 ft2 0 ft2 Medium Nli 0.6 No 0.9 No 20 26.6 ATTIC I V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2699 ftJ N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) Garage Floor 0 Blown 1022 ft2 0.11 Wood 2 Under Attic (Unvented) 1st Floor A 0 Blown 1151 ft2 0.11 Wood 3 Under Attic (Unvented) 1st Floor B 0 Blown 1609 ft2 0.11 Wood 4 Under Attic (Unvented) 2nd Floor 0 Blown 2699 ft2 0.11 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 N Garage Frame - Wood Garage Floor 13 22 4 12 268.0 ft2 0.23 0.300000 0 2 W Garage Frame - Wood 2nd Floor 13 5 8 12 68.0 ft2 0.23 0.300000 0 3 N Garage Frame - Wood 2nd Floor 13 9 4 12 112.0 ft2 0.23 0.300000 0 4 E Exterior Frame - Wood 2nd Floor 13 14 9 12 177.0 ft2 0.23 0.300000 0 5 S Exterior Frame - Wood 2nd Floor 13 9 12 108.0 ft2 0.23 0.300000 0 6 W Exterior Frame - Wood 2nd Floor 13 12 9 12 153.0 ft2 0.23 0.300000 0 7 N Exterior Frame - Wood 2nd Floor 13 6 4 12 76.0 ft2 0.23 0.300000 0 8 W Exterior Frame - Wood 2nd Floor 13 6 12 72.0 ft2 0.23 0.300000 0 9 N Exterior Frame - Wood 2nd Floor 13 6 6 12 78.0 ft2 0.23 0.300000 0 10 E Exterior Frame - Wood 2nd Floor 13 6 8 12 80.0 ft2 0.23 0.300000 0 11 N Exterior Frame - Wood 2nd Floor 13 2 2 12 26.0 ft2 0.23 0.306000 0 12 E Exterior Frame - Wood 2nd Floor 13 10 8 12 128.0 ft2 0.23 0.300000 0 13 S Exterior Concrete Block - Int Insul2nd Floor 5 31, 9 12 381.0 ft2 0 0.300000 0 14 W Exterior Concrete Block - Int Insul2nd Floor 5 14 8 12 176.0 ft2 0 0.300000 0 15 S Exterior Concrete Block - Int Insul2nd Floor 5 7 4 12 88.0 ft2 0 0.300000 0 16 W Exterior Concrete Block - Int Insul2nd Floor 5 8 4 12 100.0 ft2 0 0.300000 0 17 N Exterior Concrete Block - Int Insullst Floor A 5 45 13 6 607.5 ft2 0 0.300000 0 _ 18 E Exterior Concrete Block - Int Insun st Floor A 5 20 13 6 1270.0 ft2 0 0.300000 0 19 S Exterior Concrete Block - Int Insult st Floor A 5 7 8 13 6 I103.5 ft2 0 0.300000 0 20 E Exterior Concrete Block - Int Insutlst Floor B 5 20 8 13 6 279.0 ft2 I 0 0.300000 0 21 N Exterior Concrete Block - Int Insunst Floor B 5 16 4 13 6 20.5 ft2 i 0 0.300000 0 22 E Exterior Concrete Block - Int Insuhst Floor B 5 17 4 13 6 234.0 ft2 0 0.300000 0 _23 S Exterior Concrete Block - Int Insuflst Floor B 5 55 13 6 I 742.5 ft2 0 0.300000 0 _24 W Exterior Concrete Block- Int Insuhst Floor B 5 14 8 13 6 ft2 0 0.300000 0 25 S Exterior Concrete Block - Int Insuhst Floor B 5 7 4 13 6 I98.0 99.0 ft2 0 0.300000 0 4/29/2019 6:59 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7 aP impu PAnti_gn17 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belo w Space 26 W Exterior Concrete Block - Int Insunst Floor B 5 21 10 13 6 294.8 ft2 0 0.300000 0 27 S Exterior Concrete Block - Int Insullst Floor A 5 7 13 6 94.5 ft2 0 0.300000 0 28 W Exterior Concrete Block - Int Insunst Floor A 5 15 6 13 6 209.3 ft2 0 0.300000 0 29 N Exterior Concrete Block - Int Insunst Floor A 5 15 13 6 202.5 ft2 0 0.300000 0 30 W Exterior Concrete Block - Int Insunst Floor A 5 6 13 6 81.0 ft2 0 0.300000 0 31 N Exterior Concrete Block - Int Insul2nd Floor 5 27 10 10 4 287.6 ft2 0 0.300000 0 32 W Exterior Concrete Block - Int Insul2nd Floor 5 2 10 4 20.7 ft2 0 0.300000 0 33 N Exterior Concrete Block - Int Insul2nd Floor 5 8 8 10 4 89.6 ft2 0 0.300000 0 34 E Exterior Concrete Block - Int Insul2nd Floor 5 2 10 4 20.7 ft2 0 0.300000 0 35 N Exterior Concrete Block - Int Insul2nd Floor 5 22 2 10 4 229.1 ft2 0 0.300000 0 36 E Exterior Concrete Block - Int Insul2nd Floor 5 20 10 4 206.7 ft2 0 0.300000 0 37 S Exterior Concrete Block - Int Insul2nd Floor 5 21 4 10 4 220.4 ft2 0 0.300000 0 38 E Exterior Concrete Block - Int Insul2nd Floor 5 5 4 10 4 55.1 ft2 0 0.300000 0 39 S Exterior Concrete Block - Int Insul2nd Floor 5 7 4 10 4 75.8 ft2 0 0.300000 0 40 E Exterior Concrete Block - Int Insul2nd Floor 5 10 10 4 103.3 ft2 0 0.300000 0. 41 N Exterior Concrete Block - Int Insul2nd Floor 5 7 4 10 4 75.8 ft2 0 0.300000 0 42 E Exterior Concrete Block - Int Insul2nd Floor 5 5 4 10 4 55.1 ft2 0 0.300000 0 43 N Exterior Concrete Block - Int Insul2nd Floor 5 10 4 10 4 106.8 ft2 0 0.300000 0 44 W Exterior Concrete Block - Int Insul2nd Floor 5 17 4 10 4 179.1 ft2 0 0.300000 0 45 S Exterior Concrete Block - Int Insul2nd Floor 5 38 4 10 4 396.1 ft2 0 0.300000 0 46 W Exterior Concrete Block - Int Insul2nd Floor 5 14 8 10 4 151.6 ft2 0 0.300000 0 47 S Exterior Concrete Block - Int Insul2nd Floor 5 17 4 10 4 179.1 ft2 0 0.300000 0 48 W Exterior Concrete Block - Int Insul2nd Floor 5 21 10 10 4 225.6 ft2 0 0.300000 0 49 S Exterior Concrete Block - Int Insul2nd Floor 5 7 10 4 72.3 ft2 0 0.300000 0 50 W Exterior Concrete Block - Int Insul2nd Floor 5 15 6 10 4 160.2 ft2 0 0.300000 0 51 N Exterior Concrete Block - Int Insul2nd Floor 5 15 10 4 155.0 ft2 0 0.300000 0 52 SW Exterior Concrete Block - Int Insul2nd Floor 5 6 10 4 62.0 ft2 0 0.300000 0 DOORS # Ornt Door Type Space Storms U-Value Width eightln Area Ft In Ft 1 N Wood Garage Floor None .46 3 8 24 ft2 2 S Wood 2nd Floor None .46 2 8 8 21.3 ft2 3 E Wood 2nd Floor None .46 2 6 8 20 ft2 4 W Wood 2nd Floor None .46 3 4 8 26.7 ft2 5 E Wood 1st Floor A None .46 2 6 8 20 ft2 6 W Wood 1 st Floor A None .46 2 6 8 20 ft2 4/29/2019 6:59 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. Wall I Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 13 Metal Low-E Single Yes 0.4 0.25 N 12.5 Ift- 0 ft 0 in 0 ft 0 in None None 2 W 14 Metal Low-E Single Yes 0.4 0.25 N 27.5 ft2 0 ft 0 in 0 ft 0 in None None 3 W 16 Metal Low-E Single Yes 0.4 0.25 N 32.0 ft2 0 ft 0 in 0 ft 0 in None None 4 N 17 Metal Low-E Single Yes 0.4 0.25 N 11.3 k2 0 ft 0 in 0 ft 0 in None None 5 N 17 Metal Low-E Single Yes 0.4 0.25 N 25.0 ft2 0 ft 0 in 0 ft 0 in None None 6 N 17 Metal Low-E Single Yes 0.4 0.25 N 10.0 ft2 0 ft 0 in 0 ft 0 in None None 7 E 18 Metal Low-E Single Yes 0.4 0.25 N 120.0 ft2 0 ft 0 in 0 ft 0 in None None 8 S 19 Metal Low-E Single Yes 0.4 0.25 N I 20.0 fti 2 0 ft 0 in 0 ft 0 in None None 9 E 20 Metal Low-E Single Yes 0.4 0.25 N 200.0 ft2 0 Ti 0 in 0 ft 0 in None None 10 N 21 Metal Low-E Single Yes 0.4 0.25 N 50.0 ft? 0 ft 0 in 0 ft 0 in None None 11 E 22 Metal Low-E Single Yes 0.4 0.25 N 150.0 llft2 0 ft 0 in 0 ft 0 in None None 12 S 23 Metal Low-E Single Yes 0.4 0.25 N 50.0 fti 0 ft 0 in 0 ft 0 in None None 13 S 23 Metal Low-E Single Yes 0.4 0.25 N 12.5 ft2 0 ft 0 in 0 ft 0 in None None 14 W 24 Metal Low-E Single Yes 0.4 0.25 N 80.0 ft2 0 ft 0 in 0 ft 0 in None None 15 W 26 Metal Low-E Single Yes 0.4 0.25 N 122.5 fti 0 ft 0 in 0 ft 0 in None None 16 W 28 Metal Low-E Single Yes 0.4' 0.25 N 80.0 ft21 0 ft 0 in 0 ft 0 in None None 17 N 31 Metal Low-E Single Yes 0.4 0.25 N 14.7 ft2 0 ft 0 in 0 ft 0 in None None 18 N 33 Metal Low-E Single Yes 0.4 0.25 N 22.5 ft2l 0 ft 0 in 0 ft 0 in None None 19 E 36 Metal Low-E Single Yes 0.4 0.25 N I 135.0 ft2 0 ft 0 in 0 ft 0 in None None 20 S 37 Metal Low-E Single Yes 0.4 0.25 N 36.0 ft2 0 ft 0 in 0 ft 0 in None None 21 E 38 Metal Low-E Single Yes 0.4 0.25 N 24.0 ft2 0 ft 0 in 0 ft 0 in None None 22 E 40 Metal Low-E Single Yes 0.4 0.25 N 90.0 ft2 0 ft 0 in 0 ft 0 in None None 23 E 42 Metal Low-E Single Yes 0.4 0.25 N 24.0 ft2 0 ft 0 in 0 ft 0 in None None 24 N 43 Metal Low-E Single Yes 0.4 0.25 N 15.0 ft2 0 ft 0 in 0 ft 0 in None None 25 W 44 Metal Low-E Single Yes 0.4 0.25 N 108.0 ft2 0 ft 0 in 0 ft 0 in None None 26 S 45 Metal Low-E Single Yes 0.4 0.25 N 15.0 ft2 0 ft 0 in 0 ft 0 in None None 27 S 45 Metal Low-E Single Yes 0.4 0.25 N 30.0 ft2 0 ft 0 in 0 ft 0 in None None 28 W 46 Metal Low-E Single Yes 0.4 0.25 N 13.8 ft2 0 ft 0 in 0 ft 0 in None None 29 W 48 Metal Low-E Single Yes 0.4 0.25 N 135.0 ft2 0 ft 0 in 0 ft 0 in None None 30 W 50 Metal Low-E Single Yes 0.4 0.25 N 72.0 ft2 0 ft 0 in 0 ft 0 in None None 31 SW 52 Metal Low-E Single Yes 0.4 0.25 N 10.0 ft2 0 ft 0 in 0 ft 0 in None None GARAGE I # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 2435.965 ft2 2435.965 ft2 232 ft 12 1ft 1 4/29/2019 6:59 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software i Page 5 of 7 1�0 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000455 7740.5 424.94 799.16 .2874 6 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 2 3 4 Electric Heat Pump/ Electric Heat Pump/ Electric Heat Pump/ Electric Heat Pump/ Split Split Split Split HSPF:8.6 30 kBtu/hr HSPF:8.6 36 kBtu/hr HSPF:8.6 36 kBtu/hr HSPF:8.6 60 kBtu/hr 1 2 3 4 sys#1 sys#2 sys#3 sys#4 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 3 4 Central Unit/ Central Unit/ Central Unit/ Central Unit/ Split Split Split Split SEER: 14 30 kBtu/hr 900 cfm 0.7 SEER: 14 36 kBtu/hr 1080 cfm 0.7 SEER: 14 36 kBtu/hr 1080 cfm 0.7 SEER: 14 60 kBtu/hr 1800 cfm 0.7 1 2 3 4 sys#1 sys#2 sys#3 sys#4 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas None Garage 0.59 40 gal 80 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS v # --- Supply -- Location R-Value Area --- Return — Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 2 3 4 Attic 6 120 ft2 Attic 6 200 ft2 Attic 6 200 ft2 Attic 6 200 ft2 Attic Attic Attic Attic 81.012 Default Leakage Garage (Default) (Default) 81.012 Prop. Leak Free 1 st Floor A --- cfm 34.5 cfm 0.03 81.012 Prop. Leak Free 1st Floor A —cfm 48.3 cfm 0.03 81.012 Prop. Leak Free 2nd Floor -- cfm 81.0 cfm 0.03 0.50 0.50 0.50 1 1 2 2 3 3 4 4 4/29/2019 6:59 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 1"I FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: N Ceiling Fans: Coolin Jan Feb Mar Apr [ ] Ma X Jun Jul Au Se Oct f Nov Dec Heating f X Jan �X Feb Mar ki Apr [ ] MaY Jun JXJJul Auri r SeP Oct X� Nov Dec Ventin [ Jan [ Feb Mar [X Apr [ ] May [ Jun Jul Aug Se [X Oct [X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7I 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 781 78 78 78 78 78 PM 78 78 78 78 78 78 781 78 78 78 78 78 Heating (WD) AM 68 68 68 68 68 68 681 68 68 68 68 68 PM 68 68 68 68 68 68 681 68 68 68 68 68 Heating (WEH) AM 68 68 68 68 68 68 68I 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 01.3 Garage Floor Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 1st Floor A Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 1st Floor B Default(8 Ibs/s .ft. 0 ft2 0 ft 0I3 2nd Floor 4/29/2019 6:59 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software I Page 7 of 7