HomeMy WebLinkAboutRevision; Master & Visitor Bathroom renovationQ —
OFFICE USE ONLY:
DATE FILED: 1 \ fro
REVISION FEE: 15.O
PERMIT # i 00 3 -
RECEIPT #
PLANNING & DEVELOPMENTSERVICES
BUILDING& CODE REGULATION DIVISION -
2300 VIRGINIA AVENUE =CountY,
FORT PIERCE, FL 34982-5652
(772)462-1553 APPLICATION FOR BUILDING PERMIT REVISI
PROJECT INFORMATION
LOCATION/SITE
ADDRESS:
328 Shady Lane Port Saint Lucie
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
Renovate master bathroom and visitor's bathroom without altering existing plumbing piping
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: CBC1261568 ST: LUCIE CO CERT. #:
BUSINESS NAME: Aykon Management Consulting
QUALIFIERS NAME: Michel Menard
ADDRESS: 15800 Pines Blvd Suite 3078
CITY: Pembroke Pines STATE:! FI
PHONE (DAYTIME): 9043451774 FAX:
OWNER/BUILDER INFORMATION:
ZIP: 33027
NAME: Stephan Magloire
ADDRESS:2523 Glendale Place
CITY: Royal Palm Beach STATE: FL ZIP: 33411
PHONE (DAYTIME: 3059008883 FAX:
ARCHITECT/ENGINEER INFORMA
NAME: Steven G Wood
ADDRESS: 950 SW Sultan Drive
CITY: Port Saint Lucie STATE: FL
PHONE (DAYTIME): 772 878 7324
FAX:
SLCCCr 9123109
EMIL
tiEVISION
Revised 06130117
I-�
A OP
MOO 311:1
0ASANO
REMODELING, ADDITION, LTERATION, AND GENERAL NOTES
CONSTRUCTION TO FOLLOW 2011 &TW EDITION FLORIDA BUILDING CODE 4 ALL AMENDMENTS
1. Contractor to verify all dimensions prior 5, Do not scale drawings, if, there are written S, No egress from a bedroom or sleeping area
to the commencement of construction. dimensions to take precedence. Dimensions has been compromised by this enclosure.
2. Determine the existence of any underground and construction details may vary due to
tanks, drain fields, wiring, plumbing, piping, etc, substitution, field conditions, construction
and allow for same during construction, technique or other variables.
f I t t I 1 6. These drawinens are not intended to cover all
V STUCCO FINISH
3. Verify adequacy o existing a ec r ca sery ce conditions. Field decisions ma need to be NOTICE:
and wiring capacity. Upgrade and sub -panel as y
(TO MATCH EXISTINCsJ
required. Relocate any tv, pphone cable, made by Contractor, if this situation arises, please It is important that the Client and Contractor examine the
ATTACH PT 2 x 8 TOP PLATE
OVER FELT BACKED WIRE -LATH
contact Engineer of Record.
thermostat, fans, chimes, outlets, switches, g drawings and documentation in detail. It shall be the final
TO EXISTING GARAGE
OVER VAPOR BARRIER
smoke detectors, fixtures, etc, as may be Contractor shall allow for minor adJuatments, responsibility of the Contractor to review and double check
WINDOW HEADER
OVER MIN 15/32" GDX SHEATHING
required, Z. Certain assumptions have been made using the the plans for accuracy and compliance with regulatory
agencies. It fs customar and ordinar not to include details
g y y
w/ 3/8" TAPCON SCREWS
4. All wood members exposed to weather or in beat Judgement and experience of the design well within the knowledge of licensed Contractor. If
12" O.C. -MIN EMBED 11/2"
ATTACH ALL PT FRAMING
contact concrete and/or masonry shall be team. No demolition has been undertaken by necessary, further clarification of these plans should be
treated.
TO EXISTING GARAGE
pressure the designer to verif the conditions and
g y achieved before Signing the construction contract and
construction techniques em to ed in the g g
q y
WINDOW OPENING
p obtainfnncc9� a building permit, otherwise the Contractor assumes
structure. The contractor shall verify
1/2' DRYWALL OVER �y
TAPCON SCREWS
existing responsibility for the construction in question. Methods of
actual conditions prior to undertaking
�
w/ 3/8"
construction shall be determined by the Contractor,
2 x 8 STUDS 16" O.G.
,
�+ 12" O.G. -MIN EMBED 11/2°
FRAME WALL
I� =� III
"
/ BOTH EXISTING BATHS
WERE RENOVATED WITH
NEW DUROCK, TILE, TUB,
SINK AND TOILETS.
NO NEW PLUMBING PIPIING
OR ALTERATION OF EXISTING
PLUMBING PIPING
WAS ADDED/DONE,
MIN. R-IS INSULATION
MIN. 2 x 8 PT SILL PLATE
EXISTING w/ 3/8" TAPCON SCREWS OR EQUAL
E
GARAGE CBS WALL 0 12" O.G. - MIN EMBD I in"
4 w/ SIMPSON SP 9 EACH STUD
TOP 4 BTM,
FRAME SIFF WALL STUDS
9 16 O.C. MAX.
I
TYPICAL FRAME -IN FILL
EXISTING FOR 'GARAGE WINDOW
FIII—ICI=III—_ 6LA6 / PQUN0AT10N
t�III iuIluTIIWALL SECTION NT6lIulI—
II-1d%Z
1. ALL WORD SHALL BE DONE IN ACCORDANCE WITH THE
2014 NATIONAL ELECTRIC CODE & SHALL CONFORM WITH THE
FLORIDA BUILDING CODE & ALL LOCAL CODES.
2. FAMILY ROOMS, BEDROOMS, LIVING ROOMS, SUNROOMS,
DENS, HALLWAYS, CLOSETS, OR SIMILAR ROOMS OR AREAS
TO HAVE ARC FAULT PROTECTION PER 2014 NEC SECTION 210.12 (B)
3. ALL 15 & 20 AMP RECEPTACLES IN KITCHENS, FAMILY ROOMS,
BEDROOMS, LIVING ROOMS, SUNROOMS, HALLWAYS, CLOSETS,
OR SIMILAR ROOMS OR AREAS TO BE OF THE TAMPER RESISTANT
TYPE PROTECTION PER 2014 NEC SECTION 406.11
4. GFI-6UTLETS ARETO BE INSTALLED IN THE KnuREN, BATHROOM,
GARAGE, & OUTSIDE LOCATIONS AS NOTED (GFI) ON PLANS.
5. FINAL PLACEMENT OF ALL ELECTRICAL COMPONENTS TO BE
DETERMINED BY THE ELECTRICIAN OF RECORD IN ACCORDANCE
WITH THE 2014 NATIONAL ELECTRIC CODE & SHALL CONFORM
WITH THE FLORIDA BUILDING CODE & ALL LOCAL CODES.
6. ENGINEER OF RECORD NOT RESPONSIBLE FOR ELECTRICAL PLANS
ALL PLUM8ING,. '-ELECTRICAL,
4 AC UJORG TO FOLLOW THE
APPLIANCE LOCATIONS
RESPECTIVE FSC 201-1 &TH EDITION ARE APPROXIMATE
CODES FOR EACH TRADE
ALTERATION = LEVEL II
SCOPE OF PROJECT
TI-US PROJECT 16 FOR AN INTERIOR RENOVATION
OF THE EX16rIN6 LAUNDRY ROOM,
SOME INTERIOR WALL DEMO t RELOC4T/ON
OF THE 1UA6,gER / O 'rER t A14U TO
THE GARAGE AREA AS SHO ON THE FLOOR PLAN...
RELOCATING ELECTRIC , PLUMBING, ETC
EXISTING GARAGE iU/NDOW TO BE REMOVED t FRAMED /N
WIT44 It EXTERIOR FIN1614 TO MATCH EXISTING
REPLACE EX/STING/NCI IOOAMP PANEL
ru/ NEW 200 AMP SERVICE PANEL
ALL AREAS OF WORK TO BE FINISHED TO MATCH EX1671NO
ALL WORK /S TO BE DONE PER THE
FBC 2017 6T44 ED/T/ON PER THESE PLANS,
ALL
FX/St/NG ELECTRICAL
TO REMAIN
REPLACE EXISTING
100 AMP PANEL w/
IEW 200 AMP PANE
,
0
' D�;
EXISTINGiITCHEN
APPLIAES TO
aE RELATED
O EXISTING W/D
LOCATION
REMOVE ELECTRICAL
® E AS NEEDED
:r 1
W
'D
RELOCATE HWH `z�
EXISTING PLUMBING W
4 ELECTRICAL
TO NEW LOCATION
FOR THE WASHER/DYER D
4 AIR HANDLER 1STIl`
------------------------
nu
IIIII
=AV0WA6
,EW
6Mca5 v EXISTING GARAGE
LECTRICAL
A6 NEEDEDCODETR/C/ANORD
ELECTRICAL PLAN
SCALE: 1/4" 1'-0"
DEFACED / OF -LAMINATED CONCRETE REPAIR
I. REMOVE DELAMINATrED OR OTHERWISE UNSOUND CONCRETE, FROM AREA
TO BE PATCHED, SAW CUT AS NECESSARY TO PREPARE AFFECTED AREA.
2. DO NOT CUT REINFORCING STEEL, IF REINFORCING STEEL IS REVEALED
REMOVAL SHALL CO TINUE UNTIL 4" OF REINFORCING STEEL IS REVEALED.
3. REMOVE CONCRETE !AROUND REINFORCING STEEL APPROX. 1" AROUND
TO ALLOW NEW CONCRETE TO SURROUND REINFORCING STEEL.
4. COAT REINFORCING STEEL WITH 51KA ARMATEC 110 OR EQUAL.
5. EXISTING CONCRETE SHOULD BE PREPARED W/ A BONDING AGENT FOR PATCH,
6. POUR BACK REPAIR AREA WITH A CONCRETE MIX WiTH A MIN F-C = 4000 PSI.
MIX SHOULD INCLUD A CORROSION INHIBITOR ADMIXTURE.
-1. A FORM MAY BE US TO ALLOW FOR A PROPER EDGE 4 PROPER DRYING
IN PLACE OF PATCH
SEE ELCTRI AL PLAN
FOR APPROXIMATE
APPLIANCE LOCATIONS
REPLACE EXISTING
100 AMP PANEL w/
ELIMINATE E> (STING WINDOW
INFILL TH S OPENING F rl
w/ WOOD FRAME III
4 MATCH EX STING STUCCO
04
+/- 12'
REMOVE EXISTING
INTERIOR WOOD FRAME
NON -LOAD SRG WALLS
EXISTING
Ct38 LLS
TO RWAEMAIN
EXISTING
LOAD SRO WALL
4 DOOR OPENING
TO REMAIN
I
/�® AHUE:
�
e
C
D
-------------------------
EXISTING GARAGE
FLOOR P A
SCALE: 1/4" - 1'-0
PERMIT * 2003-0-t
PLANS REVISED
PER BLDG
DEPARTMENT
/ INSPECTOR
- -
\-
7�jo aoa0
O
U
O �
x N
O
Cal
A �
U
E�
® C)
rn
b �7
�Q■z
M■E rn
■0■ I,
A �
o�
W M �
� N er
0a00
rA
D N
z 0' �ar`.
w Q0C)0Cn
O
a� a
�W
J.11
ss
f
. tr;
M
V•
®
tv_'s'sXt
11I
iM
m
i
z
II-L
LU
®
U
Cq
as Copyright 2020
ROBERSON
DESIGN GROUP
All rights reserved.
REVISION( DATE
1-" 1-20
JOB * 20205W
DATE: 3/10/20
DRAWN BY SR
SHEET
1 of 1