Loading...
HomeMy WebLinkAboutRevision; Master & Visitor Bathroom renovationQ — OFFICE USE ONLY: DATE FILED: 1 \ fro REVISION FEE: 15.O PERMIT # i 00 3 - RECEIPT # PLANNING & DEVELOPMENTSERVICES BUILDING& CODE REGULATION DIVISION - 2300 VIRGINIA AVENUE =CountY, FORT PIERCE, FL 34982-5652 (772)462-1553 APPLICATION FOR BUILDING PERMIT REVISI PROJECT INFORMATION LOCATION/SITE ADDRESS: 328 Shady Lane Port Saint Lucie DETAILED DESCRIPTION OF PROJECT REVISIONS: Renovate master bathroom and visitor's bathroom without altering existing plumbing piping CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CBC1261568 ST: LUCIE CO CERT. #: BUSINESS NAME: Aykon Management Consulting QUALIFIERS NAME: Michel Menard ADDRESS: 15800 Pines Blvd Suite 3078 CITY: Pembroke Pines STATE:! FI PHONE (DAYTIME): 9043451774 FAX: OWNER/BUILDER INFORMATION: ZIP: 33027 NAME: Stephan Magloire ADDRESS:2523 Glendale Place CITY: Royal Palm Beach STATE: FL ZIP: 33411 PHONE (DAYTIME: 3059008883 FAX: ARCHITECT/ENGINEER INFORMA NAME: Steven G Wood ADDRESS: 950 SW Sultan Drive CITY: Port Saint Lucie STATE: FL PHONE (DAYTIME): 772 878 7324 FAX: SLCCCr 9123109 EMIL tiEVISION Revised 06130117 I-� A OP MOO 311:1 0ASANO REMODELING, ADDITION, LTERATION, AND GENERAL NOTES CONSTRUCTION TO FOLLOW 2011 &TW EDITION FLORIDA BUILDING CODE 4 ALL AMENDMENTS 1. Contractor to verify all dimensions prior 5, Do not scale drawings, if, there are written S, No egress from a bedroom or sleeping area to the commencement of construction. dimensions to take precedence. Dimensions has been compromised by this enclosure. 2. Determine the existence of any underground and construction details may vary due to tanks, drain fields, wiring, plumbing, piping, etc, substitution, field conditions, construction and allow for same during construction, technique or other variables. f I t t I 1 6. These drawinens are not intended to cover all V STUCCO FINISH 3. Verify adequacy o existing a ec r ca sery ce conditions. Field decisions ma need to be NOTICE: and wiring capacity. Upgrade and sub -panel as y (TO MATCH EXISTINCsJ required. Relocate any tv, pphone cable, made by Contractor, if this situation arises, please It is important that the Client and Contractor examine the ATTACH PT 2 x 8 TOP PLATE OVER FELT BACKED WIRE -LATH contact Engineer of Record. thermostat, fans, chimes, outlets, switches, g drawings and documentation in detail. It shall be the final TO EXISTING GARAGE OVER VAPOR BARRIER smoke detectors, fixtures, etc, as may be Contractor shall allow for minor adJuatments, responsibility of the Contractor to review and double check WINDOW HEADER OVER MIN 15/32" GDX SHEATHING required, Z. Certain assumptions have been made using the the plans for accuracy and compliance with regulatory agencies. It fs customar and ordinar not to include details g y y w/ 3/8" TAPCON SCREWS 4. All wood members exposed to weather or in beat Judgement and experience of the design well within the knowledge of licensed Contractor. If 12" O.C. -MIN EMBED 11/2" ATTACH ALL PT FRAMING contact concrete and/or masonry shall be team. No demolition has been undertaken by necessary, further clarification of these plans should be treated. TO EXISTING GARAGE pressure the designer to verif the conditions and g y achieved before Signing the construction contract and construction techniques em to ed in the g g q y WINDOW OPENING p obtainfnncc9� a building permit, otherwise the Contractor assumes structure. The contractor shall verify 1/2' DRYWALL OVER �y TAPCON SCREWS existing responsibility for the construction in question. Methods of actual conditions prior to undertaking � w/ 3/8" construction shall be determined by the Contractor, 2 x 8 STUDS 16" O.G. , �+ 12" O.G. -MIN EMBED 11/2° FRAME WALL I� =� III " / BOTH EXISTING BATHS WERE RENOVATED WITH NEW DUROCK, TILE, TUB, SINK AND TOILETS. NO NEW PLUMBING PIPIING OR ALTERATION OF EXISTING PLUMBING PIPING WAS ADDED/DONE, MIN. R-IS INSULATION MIN. 2 x 8 PT SILL PLATE EXISTING w/ 3/8" TAPCON SCREWS OR EQUAL E GARAGE CBS WALL 0 12" O.G. - MIN EMBD I in" 4 w/ SIMPSON SP 9 EACH STUD TOP 4 BTM, FRAME SIFF WALL STUDS 9 16 O.C. MAX. I TYPICAL FRAME -IN FILL EXISTING FOR 'GARAGE WINDOW FIII—ICI=III—_ 6LA6 / PQUN0AT10N t�III iuIluTIIWALL SECTION NT6lIulI— II-1d%Z 1. ALL WORD SHALL BE DONE IN ACCORDANCE WITH THE 2014 NATIONAL ELECTRIC CODE & SHALL CONFORM WITH THE FLORIDA BUILDING CODE & ALL LOCAL CODES. 2. FAMILY ROOMS, BEDROOMS, LIVING ROOMS, SUNROOMS, DENS, HALLWAYS, CLOSETS, OR SIMILAR ROOMS OR AREAS TO HAVE ARC FAULT PROTECTION PER 2014 NEC SECTION 210.12 (B) 3. ALL 15 & 20 AMP RECEPTACLES IN KITCHENS, FAMILY ROOMS, BEDROOMS, LIVING ROOMS, SUNROOMS, HALLWAYS, CLOSETS, OR SIMILAR ROOMS OR AREAS TO BE OF THE TAMPER RESISTANT TYPE PROTECTION PER 2014 NEC SECTION 406.11 4. GFI-6UTLETS ARETO BE INSTALLED IN THE KnuREN, BATHROOM, GARAGE, & OUTSIDE LOCATIONS AS NOTED (GFI) ON PLANS. 5. FINAL PLACEMENT OF ALL ELECTRICAL COMPONENTS TO BE DETERMINED BY THE ELECTRICIAN OF RECORD IN ACCORDANCE WITH THE 2014 NATIONAL ELECTRIC CODE & SHALL CONFORM WITH THE FLORIDA BUILDING CODE & ALL LOCAL CODES. 6. ENGINEER OF RECORD NOT RESPONSIBLE FOR ELECTRICAL PLANS ALL PLUM8ING,. '-ELECTRICAL, 4 AC UJORG TO FOLLOW THE APPLIANCE LOCATIONS RESPECTIVE FSC 201-1 &TH EDITION ARE APPROXIMATE CODES FOR EACH TRADE ALTERATION = LEVEL II SCOPE OF PROJECT TI-US PROJECT 16 FOR AN INTERIOR RENOVATION OF THE EX16rIN6 LAUNDRY ROOM, SOME INTERIOR WALL DEMO t RELOC4T/ON OF THE 1UA6,gER / O 'rER t A14U TO THE GARAGE AREA AS SHO ON THE FLOOR PLAN... RELOCATING ELECTRIC , PLUMBING, ETC EXISTING GARAGE iU/NDOW TO BE REMOVED t FRAMED /N WIT44 It EXTERIOR FIN1614 TO MATCH EXISTING REPLACE EX/STING/NCI IOOAMP PANEL ru/ NEW 200 AMP SERVICE PANEL ALL AREAS OF WORK TO BE FINISHED TO MATCH EX1671NO ALL WORK /S TO BE DONE PER THE FBC 2017 6T44 ED/T/ON PER THESE PLANS, ALL FX/St/NG ELECTRICAL TO REMAIN REPLACE EXISTING 100 AMP PANEL w/ IEW 200 AMP PANE , 0 ' D�; EXISTINGiITCHEN APPLIAES TO aE RELATED O EXISTING W/D LOCATION REMOVE ELECTRICAL ® E AS NEEDED :r 1 W 'D RELOCATE HWH `z� EXISTING PLUMBING W 4 ELECTRICAL TO NEW LOCATION FOR THE WASHER/DYER D 4 AIR HANDLER 1STIl` ------------------------ nu IIIII =AV0WA6 ,EW 6Mca5 v EXISTING GARAGE LECTRICAL A6 NEEDEDCODETR/C/ANORD ELECTRICAL PLAN SCALE: 1/4" 1'-0" DEFACED / OF -LAMINATED CONCRETE REPAIR I. REMOVE DELAMINATrED OR OTHERWISE UNSOUND CONCRETE, FROM AREA TO BE PATCHED, SAW CUT AS NECESSARY TO PREPARE AFFECTED AREA. 2. DO NOT CUT REINFORCING STEEL, IF REINFORCING STEEL IS REVEALED REMOVAL SHALL CO TINUE UNTIL 4" OF REINFORCING STEEL IS REVEALED. 3. REMOVE CONCRETE !AROUND REINFORCING STEEL APPROX. 1" AROUND TO ALLOW NEW CONCRETE TO SURROUND REINFORCING STEEL. 4. COAT REINFORCING STEEL WITH 51KA ARMATEC 110 OR EQUAL. 5. EXISTING CONCRETE SHOULD BE PREPARED W/ A BONDING AGENT FOR PATCH, 6. POUR BACK REPAIR AREA WITH A CONCRETE MIX WiTH A MIN F-C = 4000 PSI. MIX SHOULD INCLUD A CORROSION INHIBITOR ADMIXTURE. -1. A FORM MAY BE US TO ALLOW FOR A PROPER EDGE 4 PROPER DRYING IN PLACE OF PATCH SEE ELCTRI AL PLAN FOR APPROXIMATE APPLIANCE LOCATIONS REPLACE EXISTING 100 AMP PANEL w/ ELIMINATE E> (STING WINDOW INFILL TH S OPENING F rl w/ WOOD FRAME III 4 MATCH EX STING STUCCO 04 +/- 12' REMOVE EXISTING INTERIOR WOOD FRAME NON -LOAD SRG WALLS EXISTING Ct38 LLS TO RWAEMAIN EXISTING LOAD SRO WALL 4 DOOR OPENING TO REMAIN I /�® AHUE: � e C D ------------------------- EXISTING GARAGE FLOOR P A SCALE: 1/4" - 1'-0 PERMIT * 2003-0-t PLANS REVISED PER BLDG DEPARTMENT / INSPECTOR - - \- 7�jo aoa0 O U O � x N O Cal A � U E� ® C) rn b �7 �Q■z M■E rn ■0■ I, A � o� W M � � N er 0a00 rA D N z 0' �ar`. w Q0C)0Cn O a� a �W J.11 ss f . tr; M V• ® tv_'s'sXt 11I iM m i z II-L LU ® U Cq as Copyright 2020 ROBERSON DESIGN GROUP All rights reserved. REVISION( DATE 1-" 1-20 JOB * 20205W DATE: 3/10/20 DRAWN BY SR SHEET 1 of 1