HomeMy WebLinkAboutProduct Approval; Metal RoofingFlorida Building Code Online 7/19/20, 9:19 PM
BCIS Home I Lag In I User Registration I Hot Topics I Submit Surdierge I Stets & Facts I Publications
FL #
Application Type
Cade Version
Application Status
Permitting Department
St. Lucie County
Product Manufacturer
Gulf Coast Supply & Manufacturing, LLC.
Address/Phone/Email
4020 S. W. 449th Street
Horseshoe Beach, FL 32648
(352) 498-0778
lnfo@gulfcoastsupply.com
Authorized Signature
Eng David
lnfo@gulfcoastsupply.com
Technical Representative
David Eng
14429 SW 2nd PI
FILE
COPY
Ste G30��
Newberry, FL 32669
(352) 498-0778
&9913
Info@gulkoastsupply.com
FOR
Quality Assurance Representative
David Eng
CODE COMPLIANCE
Address/Phone/Email
144290 2nd PI
Ste G30
it i
STD' U CIE COL) TY
a7 V V(�
FL 669
�V(F°�"��'('
13�OCC JJ Z9
/
(352) 498 0778NewberM
david.eng@gulfcoastsupply.com
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
Daniel S. Kuhn
the Evaluation Report
Florida License
PE-75519
Quality Assurance Entity
Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date
04/12/2024
Validated By
Locke Bowden P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence FL11651 R3 COI Cert of Independence 2017-10.09.odf
http://www.floridabuilding.org/pr/pr. app dti.aspx?param=wGEVXQwtDgsQFc5K%2fTrZeCSHgw99R5wgrf90EegvkzBZ4cWkSTfwnA%3d%3d Page 1 of 6
Florida Building Code Online
7/19/20, 9:19 PM
Referenced Standard and Year (of Standard) Standard Year
FM 4471
1992
TAS 100
1995
TAS 110
2000
TAS 125
2003
UL 1897
2012
UL 580
2006
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Method 1 Option D
10/10/2017
10/12/2017
10/17/2017
12/12/2017
Summary of Products
,Go to Page I^J - - ,� 0 Page / 2'00
FL tf
Model, Number or Name
Description
11651.1
0.032" Aluminum SV Crimp
Min 0.032" 5 V Crimp Aluminum Roof Panel over 15/32"
Plywood
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL11651 R3 II FL11651 I R3 Metal Roof Panel Detall-
signed.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-108.SPSF
Created by Independent Third Party: Yes
Other: -108.5 psf @ 12" o.c. Install per manufacturers
Evaluation Reports
details. Not for use In HVHZ Zones.
FL11651 R3AE FLI1651 1 R3 0325VCrimo IS-
32Plvwood NonHVHZ-signed.odf
Created by Independent Third Party: Yes
11651.2
0.032" Aluminum Gulf Lok
Min 0.032" Aluminum Gulf,Lok 16" Wide Roof Panel over
IS/32" Plywood
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FLi 1651 ,R3 II fi11651 2 R3 Metal Roof Panel Detall-
1gned.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-116.OPSF
,Created by Independent Third Party: Yes
Other: -52.5 psf @ 5 3/16" o.c. fastener spacing. -116.0 psf
@ 5 3/16" o.c. fastener spacing. Install per manufacturers
details..Not for use,in HVHZ Zones.
Evaluation Reports.
FL11651 R3 AE FL11651 2 R3 032GulfLok 16 15-
32Plywood. NonHVHZ-signed.odf
Created by Independent Third Party: Yes
11651.3
1" 24ga. Gulf Snap
1" Gulf Snap 24 Ga. 17" wide Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R3 II FL11651 3 R3 Metal Roof Panel Detall-
Signed.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/--131.OPS
Created by Independent Third Party: Yes
Other: -67.3 psf @ 24" o.c. clip spacing. -131 psf @ 6" o.c.
clip spacing. Install per manufacturers details. For use in
Evaluation Reports
FL11651 R3 AE FL11651 3 R3 1 24GulfSnan 17 IS-
32Plvwood HVHZ-signed.pd
HVHZ Zones.
Created by Independent Third Party: Yes
http://www.floridabuilding.org/prlpr_app_dti.aspx?param=WGEVXQWtDgSQFCSK%2fTrZeCSHgw99R5wgrf90EegvkzBZ4cWkSTfwnA%3d%3d Page 2 of 6
Florida Building Code Online
7/19/20, 9:19 PM
11651.4.
1" 24ga. VersaLoc
1" VersaLoc 24ga 16:5" Wide Roof Panel over 15/32" Plywood
Limitsof Use
Installation Instructions
Approvedfor use in HVHZ: Yes
FL11651 R3 II FL11651 4 R3 Metal Roof Panel Detail -
51g0ed.odP
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: ban Kuhn, P.E. 75519
Design Pressure: +N/A/-138.6PSF
treated by Independent Third Party: Yes
Other: -71 psf @ 24" o.c. clip spacing. -138.5 psf @ 6" o.c.
clip spacing. Install per manufacturers details. For Use In
Evaluation Reports
FL11651 R3 AE FL11651 4 R3 24VersaLoc SR 16.Sj5z-
32Plvwood HVHZ-slaned.odf
HVHZ Zones.
Created by Independent Third Party: Yes
11651.5
1" VersaLoc .032" Aluminum
1" VersaLoc min .032" Aluminum over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
FL11651 R3 II FL11651 5 R3 Metal Roof Panel Detail -
B1gagAi f
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-IDI.OPSF
Created by Independent Third Party: Yes
Other: -63.3 psf @ 24" o.c. clip spacing. -101.0 psf @ 6" o.c.
clip spacing. Install per manufacturers details. For use In
Evaluation Reports
FL11651 R3 AE FL11651 5 R3 lin 032VersaLoc
SR 16 15-32PI ood HVHZ-si ned.pdf
HVHZ Zones.
Created by Independent Third Party: Yes
11651.6
1.5" 24ga. Gulf Snap
'1.5" Gulf Snap 24ga. 16" Wide Roof Panel over 15/32"
Plywood
Limits of Use
Installation Instructions
Approved for use. in HVHZ: Yes
Approved for use outsideHVHZ: Yes
FL11651 R3 II FL11651 6 R3 Metal Roof Panel Detail -
signed.odf
Impact Resistant:- N/A
Verified By: Dam Kuhn, P.E. 75519
Design Pressure: +N/A/-116.0PSF
Created by Independent Third Party: Yes
Other: -86.0 psf @ 24" o.c. clip spacing. -108.5 psf Ca) 12"
Evaluation Reports
o.c. clip spacing.-116.0. psf @ 6" o.c. clip spacing. Install per
FL11651 R3 AE FL11651 6 R3 1.5 24GulfSnan 16 IS-
32Plywood VHZ-signed.pdf
manufacturersdetals. For use In HVHZ Zones.
Created by Independent Third Party: Yes
11651.7
1.5" 24ga. VersaLoc
1.5" VersaLoc min 24ga. 16" wide Roof Panel over 15/32"
Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R3 II FL11651 7 R3 Metal Roof Panel Detail -
signed.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-123.SPSF
Created by Independent Third Party: Yes
Other: -59.75 psf @ 24" o.c, clip spacing. -123.5 psf @ 12"
Evaluation Reports
o.c. clip spacing. Install per manufacturers details. For use In
FL11651 R3 AE FL11651 7 R3 1.5 24VersaLoc 161g
32Plywood HVHZ-signed.pdf
HVHZ Zones.
Created by Independent Third Party: Yes
11651.8
2" 24ga Megal-oc
Min 24 Ga. 2".MegaLoc 18" wide Roof Panel over 15/32"
Plywood
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL11651 R3 II FL11651 8 R3 Metal 'Roof Panel Detail -
,sjaned.odf
Approved for -use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-108.SPSF
Created by Independent Third Party: Yes
Other: -71:0 psf @ 24" o.c.. clip spacing. -108.5 psf @ 12"
o.c.. clip .spacing. Install .per manufacturers details. Not for use
Evaluation Reports
FL11651 R3 AE FL11651 8 R3 24VersaLoc 18 15-
32Plywood NonHVHZ-signed odf
In HVHZ Zones.
,Created by Independent Third Party: Yes
11651.9
24 Ga. Gulf Lok
Min 24 Ga. Gulf Lok 16" Wide over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R3 II FL11651 9 R3 Metal Roof Panel Detail -
iiiineA.W
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-96.7PSF
Created by Independent Third Party: Yes
Other: -81.75 psf @ 10-1/4" o.c. fastener spacing. -96.76
psf @ 5-1/8" o.c. fastener spacing.-121.75 psf @ 5-1/8"
Evaluation Reports
FL11651 R3 AE FL11651 9 R3 24GulfLok 16 15-
32Plvwood NonHVHZ-signed.odf
fastener spacing. -161 psf @ 5-1/8" fastener spacing. Install
per manufacturers details. Not for use in HVHZ Zones.
Created by Independent Third Party: Yes
http:l/www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXOwtDgsOFc5K%2fTrZoCSHgw99R5wgrf90EegvkzBZ4cWkSTfwnA-A3d%3d Page 3 of 6
Florida Building Code Online . - -- 7119120, 9:19 PM
11651.10 124 Ga. Gulf Seam
Limits of Use
Approved for usedn HVHZ: No
Approved for use outside HVHZ: Yes
Impact. Resistant:; N/A
Design Pressure: +N/A/-'93.SPSF
Other: -.93.5 psf @ 18" o.c. Install per manufacturers details.
Not for use In HVHZ Zones.
11651.11 124 Ga. Gulf Seam
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-108.SPSF
Other: -69.25 psf @ 24" o.c. clip spacing. -108.5 psf @ 12"
o.c, clip spacing. Install per manufacturers details. Not for use
In HVHZ Zones.
11651.12 126 Ga. 5V Crimp
Limits.of Use
Approved for use In HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-156.SPSF
Other:.-108.5 psf @ 12" o.c. fastener spacing.-156.5 psf @
6" o.c. fastener spacing. Install per manufacturers details. For
use In HVHZ Zones.
Min 24 Ga. Gulf Seam 16" Wide Roof Panel over 1x4 Wood
Purlins over 15/32" -Plywood
Installation
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
Min 24 Ga. Gulf Seam, 1 3/4" Snap Lock, 18" Wide Roof Panel
over 15/32" Plywood
Installation Instructions
FL11651 R3 •II FLS1651—U R3 Metal Roof Panel Detail-
Slglled.odf
Verified By: Dan Kuhn, P.E. 75519 ,
Created by Independent Third Party: Yes
Evaluation Reports
Created
Party: Yes
Min 26 Ga., 5V Crimp Roof Panel over 15/32" Plywood
Installation Instructions
FL11651 'R3 II FL11651 32 R3 Metal Roof Panel Detail-
signed.pdf
Verified By:Aan•Kuhn, P.E. 75519
Created, by, Independent Third Party: Yes
,Evaluation Reports
FL11651 113 AE FL11651 12 R3 265vCrimo 15-
Created by Independent Third Party: Yes
111651.13 126 Ga. SV Crimp / I Min 26 Ga. 5V Crimp over 15/32" Plywood
of Use
ved for use in
Appro VHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-131.PSF
Other: -94.25 psf @ 16" o.c, fastener pattern. -131.0 psf @
16" o.c. fastener pattern. Install per manufacturers details.
Not for use in HVHZ Zones.
11651.14 126 Ga. 5V Crimp
Limits of Use
Approved forusein HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure:+N/A/-156.SPSF
Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf'@
6" o.c. fastener spacing. Install per manufacturers details. For
use in HVHZ Zones.
11651.15 126 Ga. Gulf Lok
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-161.OPSF
Other: -63.5 psf @ 5 3/16" o.c. fastener spacing.-121.75
psf @ 5 3/16" spacing.-161.0 psf @ 5 3/16" o.c. fastener
spacing. Install per manufacturers details. For use in HVHZ
Zones.
Installation Instructions
FL11651 R3�1 FLSi651 13�3 Metal Roof Panel Detail-
si egn d odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 13 R3 265vCrimp 15-
3 Pywood NonHVHZ-sinned odf
Created by Independent Third Party: Yes
Min 26 Ga. 5V Crimp Roof Panel over 1x4 Wood Purlins over
15/32" Plywood
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Yes
Min 26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood
Installation Instructions
FL11651 R3 II ELS1651 15 R3 Metal Roof Panel Detail-
sioned.Qdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 19 oz 26GuIfLok 16 IS-
32Plvwood HVHZ-sianed.pff
Created by Independent Third Party: Yes
http://www.floridabuilding.org/prlpr_app_dti.aspx?param=wGEVXQwtDgsQFc5K%2fTrZeCSHgw99RSwgrf96EegvkzBZ4cWkSTfwnA%3tl%3d Page 4 of 6
Florida Building Code Online - - 7/19/20, 9:19 PM
11651.16
26 Ga. Gulf Lok
Min 26 Ga. Gulf Lok 16" Wide Roof Panel over 1'S/32" Plywood
Limits of Use
Installation Instructions
Approved'for use.in HVHZ: No
FL116SI R3 I1 FL11651 16 R3 Metal Roof Panel Detail -
519MMLDdf
Approved for use outside HVHZ.- Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-63.SPSF
Created by Independent Third Party: Yes
Other: -63.5 psf @ 5 3/16" o.c. fastener spacing.-121.75
Evaluation Reports
psf @ 5 3/16" fastener spacing. -.161 psf @ 5 3/16" fastener
FL11651 R3 AF FL11651 16 R3.. 26GuIfLok 16 15-
32Plvwood NonHVHZ-siened.odf
Created by Independent Third Party: Yes
spacing. Install per manufacturers details. Not for use in
HVHZ Zones.
11651.17
26 Ga. GuIfPBR
Min 26 Ga. Gulf PBR Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL11651 R3 II FL11651 17 R3 Metal Roof Panel Detail -
sigped.p&
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-154.7PSF
Created by Independent Third Party: Yes
Other: -59.25 psf @ 24" o.c. fastener pattern.-154.75 psf @
Evaluation Reports
12" o.c, fastener pattern. Install per manufacturer details. Not
FL11651 R3 AF FL11651 17 R3 26GuIfPBR IS -
32P ywood NonHVHZ-signed.odf
for use In HVHZ
Created by Independent Third Party: Yes
11651.18
26rGa. GulfPBR
Min 26: Ga. GuIfPBR Roof Panel over 1x4 Wood Purlins over
15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
Approved for,use outside. HVHZ.- Yes
FL11651 R3 II FL11651 16 R3 Metal Roof Panel Detail -
sloned.odf
Impact Resistant: N/A
Verified'�By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-151.7PSF
Created by Independent Third Party: Yes
Other: -100.5 psf @ 24" o.c., fastener spacing.-151.7S psf @
Evaluation Reports
12" fastener spacing. Install per manufacturer's details. For
FL11651 R3 AF FL11651 18 R3 26GuIfP8R Sx4 15-
32PIymod HVHZ-sig0ed.gff
use In HVHZ Zones
Created by Independent Third Party: Yes
11651.19
26 Ga. GulfPBR
Min 26 Ga. GuIfPBR over 15/32" Plywood
,Limits of Use
Installation Instructions
*Approved for use in HVHZ: Yes
FL11651 R3 II FL11651 19 R3 Metal Roof Panel Detail -
signed.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-154.7PSF
Created by Independent Third Party: Yes
Other: -60.5 psf @ 24" o.c. fastener spacing.-154.7S psf @
Evaluation Reports
12" o.c. fastener spacing. Install per manufacturer's details.
FL11651 R3 AE FL11651 19 R3 26GuIfPBR 15-
For use in HVHZ Zones.
32PIy_wood HVHZ-signed.pg
Created by Independent Third Party: Yes
11651.20
26 Ga. GulfPBR
Min 26 Ga. GuIfPBR over 1x4 Wood Purlins over 15/32"
Plywood
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL11651 R3 IT FL11651 20 R3 Metal Roof Panel Detail-
sigied.pdf
Approved,for'use outside HVHZ: Yes
ImpactResistant: N/A
Verified By: Dan Kuhn, P.E. 75519
.Design Pressure: +N/A/-151.7PSF
Created by Independent Third.. Party: Yes
Other:.-94.25 psf'@ 24" o.c. fastener spacing.-151.75 psf @
12" fastener spacing. Install per manufacturers details. Not
Evaluation,Reports
FL11651 R3 AE FL11651 20 R3 26GulfPBR 1x4 IS -
NonHVH2-signed.odf
for use In HVHZZones32PIMood
Created by Independent Third Party: Yes
Goao-Page� 1' 0 0 Page 1 / 2.0 0-
ack 0 F.71
Contact Us:: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer, [oovdeh[ 200]-2013 State of Florida.:: Privacy Statement :: Accessibility statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. IF you have any questions, please contact 850.487.1395. -Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have
http://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXOwtDgSQF05K%2fTrZeCSHgw99RSwgrf9DEegvkzBZ4cWkSTfwnA%3d%3d Page 5 of 6
Florida Building Code Online 7119/20, 9:19 PM
one. The smalls provided may be used far official communication with the licensee. However small addresses are public record. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made avellable to the public. To determine if you are a licensee under Chapter
455, F.S., please dick huL.
Product Approval Acceptor
® go
Credit Card
Safe