_ Po„ STATE OF FLOIjIDA PERMIT NO. 'Sf • ��03
DEPARTMENT OF HEALTH DATE PAID: B'16'L01d
uQ, ONSITE SEWAGE TREATMENT AND DISPOSAL FEE PAID:
'q fir' SYSTEM RECEIPT
APPLICATION FOR CONSTRUCTION PERMIT
APPLICATION FOR:
[X] New System [ ] Existing System [ ] Holding Tank [ ] Innovative
[ ] Repair [ ] Abandonment [ ] Temporary [ ]
APPLICANT: . David Agler
AGENT: Culpepper & Terpening, Inc. TELEPHONE: 772-464-3537
MAILING ADDRESS: 2980 South 25th Street, Ft. Pierce, FL 34981
TO BE COMPLETED BY APPLICANT OR APPLICANT'S AUTHORIZED AGENT. SYSTEMS MUST BE CONSTRUCTED
BY A PERSON LICENSED PURSUANT TO 489.105(3)(m) OR 489.552, FLORIDA STATUTES. IT IS THE
APPLICANT'S RESPONSIBILITY TO PROVIDE DOCUMENTATION OF THE DATE THE LOT WAS CREATED OR
PLATTED (MM/DD/YY) IF REQUESTING CONSIDERATION OF STATUTORY GRANDFATHER PROVISIONS.
PROPERTY INFORMATION '
LOT: 10 BLOCK: 172 SUBDIVISION: Lakewood Park, Unit 12A PLATTED: 1959
PROPERTY ID #:
1301-615-0093-000-3
ZONING: RM-5 I/M OR EQUIVALENT: [ Y IfI
PROPERTY SIZE: 0.22 ACRES WATER SUPPLY: [ ] PRIVATE PUBLIC [X ]<=2000GPD [ ]>2000GPD
IS SEWER AVAILABLE AS PER 381.0065, FS? [ Y /�N )] DISTANCE TO SEWER: _VA FT
PROPERTY ADDRESS: 5120 Sanibel Avenue
DIRECTIONS TO PROPERTY: -192 feet Southwest of the intersection of Sanibe
Winter Garden
BUILDING INFORMATION [X] RESIDENTIAL [ ] COMMERCIAL
Unit Type of
No Establishment
1
Single Familv Res
`'
3
4
No. of Building Commercial/Institutional System Design
Bedrooms Area Sq£t Table 1 Chapter 64E-6, FAC
3 1359 S.F.
[ ] Floor/Equipment Drains [ ] Other (Specify)
a
SIGNATURE: ......... DATE:
DH 4015, 08/09 (Obsoletes previous editions which may not be used)
Incorporated 64E-6.001, FAC Page 1 of 4
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
SITE EVALUATION AND SYSTEM SPECIFICATION
APPLICANT: David Agler
CONTRACTOR / AGENT: Culpepper & Terpeninq, Inc.
LOT: 10 BLOCK: 172
SUBDIVISION: Lakewood Park ID#:1301.615-0093-000-3
APPLICATION # AP'1473723
PERMIT # 56-SF-2048103
DOCUMENT # SE1268838
TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE, OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE
REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS.
PROPERTY SIZE CONFORMS TO SITE PLAN: [X]YES [ ]NO NET USABLE AREA AVAILABLE: 0.22 ACRES
TOTAL ESTIMATED SEWAGE FLOW: 300 GALLONS PER DAY [ RESIDENCES-TABLEI / OTHER -TABLE 2 ]
AUTHORIZED SEWAGE FLOW: 329.99 GALLONS PER DAY [ 1500 GPD/ACRE j OR 2500 GPD/ACRE ]
UNOBSTRUCTED AREA AVAILABLE: 750.00 SQFT UNOBSTRUCTED AREA REQUIRED: 750.00` SQFT
HENCHMARK/REFERENCE POINT LOCATION: Site BM Set
ELEVATION OF PROPOSED SYSTEM SITE 3.00 [
N//DD on asphalt paving west of Sanibel Ave.
aES 1/ FT ] [ ABOVE / BELOW ] BENCHMARK/REFERENCE POINT
THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED
SYSTEM TO THE FOLLOWING FEATURES
SURFACE WATER:
FT DITCHES/SWALES: 68
FT NORMALLY WET: [ ]YES
[X]NO
WELLS: PUBLIC:
FT LIMITED USE: FT PRIVATE: FT NON -POTABLE:
FT
BUILDING FOUNDATIONS:
5 FT PROPERTY LINES:
11 FT POTABLE WATER LINES:
44 FT
SITE SUBJECT TO FREQUENT FLOODING?
10 YEAR FLOOD ELEVATION FOR SITE:
nTT. rDnVTi4 TMCnaMnmTnM CTMV t
[ ]YES [X]NO 10 YEAR FLOODING? [ ]YES [X]NOI
FT [ MSL / NGVD ] SITE ELEVATION: FT [ MSL / NGVD
USDA SOIL SERIES:Lawnwood
Munsell #/Color
sand
Texture
Depth
1 OYR 5/1
Sand
0 To 23
1OYR 6/1
Sand
21 To 36
10YR 2/1
Spodic Material
36 To 45
7.5YR 313
Sand
45 To 60
1 OYR 3/2 -
Sand
60 To 67
10YR 5/3
Loamy Sand
67 To 72
unmTnM CrmC 9
USDA SOIL SERIES:Lawnwood sand
Munsell #/Color Texture
Depth
1OYR 411
Sand
0To8
10YR 5/1
Sand
8 To 22
10YR 611
Sand
22 To 25
10YR 211
Sand
25 To 37
10YK 211
Spodic Material
37 To 44
7.5YR 3/3
Sand
44 To 60
1 OYR 3/2
Sand
60 To 68
10YR 513
Loamy Sand
68 To 72
OBSERVED WATER TABLE: 70.00
ESTIMATED WET SEASON WATER TABLE
INCHES [ ABOVE / BELOW ] EXISTING GRADE
ELEVATION: 21 INCHES [ ABOVE
TYPE:.
/ BELOW ]
[ PERCHED / APPARENT ]
EXISTING GRADE
HIGH WATER TABLE VEGETATION:
[ ]YES [X]NO MOTTLING:
[X]YES
[ ]NO
DEPTH: 21.00 INCHES
SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: Sand/0.80 DEPTH OF EXCAVATION:
DE4INFIELD CONFIGURATION: [X ] TRENCH [ ] BED [ ] OTHER (SPECIFY)
- REMARKS/ADDITIONAL CRITERIA
WSWT determined using USDA WSS and soil borings. 10YR 6/1 stripping in 10YR 5/1 matrix> 10%with diffuse boundaries starting
at 21" In SBG1. SBt 3" below BM. SB2 4" below BM.
SITE EVALUATED BY:
INCHES
DATE: 03/26/2020
Collier, Hunter (Title: Environmental Speclalisel) (Florida Department or neann In ar. L
DR 4015, 08/09 (obsoletes previous editions which may not be used) Incorporated: 64E-6.001, FAC
Page 3 of 4
AP1473723 EID2048103 v 1.0.2
ESTATE OF FLORIDA
'DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL
SYSTEM ,
CONSTRUCTION PERMIT FOR: OSTDS New
APPLICANT: David Agler
PROPERTY ADDRESS: 5120 Sanibel Ave Fort Pierce, FL 34951
PERMIT #:56-SF-2048103
APPLICATION #:AP1473723
DATE PAID:
FEE PAID:
RECEIPT #:
DOCUMENT #: PR1319430
LOT: 10 BLOCK: 172 SUBDIVISION: Lakewood Park
[SECTION, TOWNSHIP, RANGE, PARCEL NUMBER]
PROPERTY ID #: 1301-615-0093-000-3 [OR TAX ID NUMBER]
SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION
381.0065, F.S., AND CHAPTER 64E-6, .F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE
SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS,
WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE
PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THI PERMIT BEING MADE NULL AND VOID.
ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL,
STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY.
SYSTEM DESIGN AND SPECIFICATIONS
T [ 900 ] GALLONS / GPD Seotic New CAPACITY
A [ ] GALLONS / GPD N/A CAPACITY
N [ ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS]
K [ ] GALLONS DOSING TANK CAPACITY [ ]GALLONS 61 ]DOSES PER 24 RRS #Pumps [ ]
D [ 375 ] SQUARE FEET Drainfield New SYSTEM
R [ ] SQUARE FEET N/A SYSTEM
A TYPE SYSTEM: [ ] STANDARD [ ] FILLED [X] MOUND [ ]
I CONFIGURATION: [X] TRENCH
N
F LOCATION OF BENCHMARK: Site BM set
I ELEVATION OF PROPOSED SYSTEM SITE
E BOTTOM OF DRAINFIELD TO BE
L
D F
0
T
H
E
R
[ • ] BED [ ]
N/D on asphalt paving west of Sanibel Ave.
[ 3.00 ][ INCHES FT ][ABOVE BELOW BENCHMARK/REFERENCE POINT
[ 0.00 ][ INCHES FT I GABOVEq BELOW] BENCHMARK/REFERENCE POINT
- Wuitt U; L c i.uvj ayu: J NAG V"Xun .. Wuitt U: L a
system Is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of
gpd• _
SPECIFICATIONS BY: Hunter A Collier TITLE: Environmental Specialist I
APPROVED BY: \ ] LE: Environmental Specialist I St. Lucie CAD
Eunter A Collier
DATE ISSUED: 03/31/2020 EXPIRATION DATE: 09/23/2021
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 1 of 3
v 1.1.4 AP1473723 SE1268838
NOTICE OF RIGHTS
r-ti party whose substantial interest is affected by this order may petition for an
administrative hearing pursuant to sections 120.569 and 120.57, Florida Statutes. Such
proceedings are governed .by Rule 28-106, Florida Administrative Code. A petition for
administrative hearing must be in writing and must be received by the Agency Clerk for the
Department, within twenty-one (21) days from the receipt of this order. The address of the
Agency Clerk is 4052 Bald Cypress Way, BIN A-02, Tallahassee, Florida 32399. The Agency
Clerk's facsimile number is 850-413-8743.
Mediation is not available as an alternative remedy.
Your failure to submit a petition for hearing within 21 days from receipt of this order will
constitute a waiver of your right to an administrative hearing, and this order shall become a 'final
order'.
Should this order become a final order, a party who is adversely affected by it is entitled
to judicial review pursuant to Section 120.68, Florida Statutes. Review proceedings are
governed by the Florida Rules of Appellate Procedure. Such proceedings may be commenced
by filing one copy of a Notice of Appeal with the Agency Clerk of the Department of Health and a
second copy, accompanied by the filing fees required by law, with the Court of Appeal in the
appropriate District Court. The notice must be filed within 30 days of rendition of the final order.
Q .