Loading...
HomeMy WebLinkAboutReviewed Wind Load ChartBUILDIA 'S PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPONENTS A CLADDING (P S F) FOR ASCE 7-10 - PEAK ROOF HEIGHT LESS THAN OR EQUAL TO 60 FEET BASIC WIND SPEED = 170 mph RISK CATEGORY ll BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) PEAK L** LESS THAN 7'-9" L** GREATER OR EQUAL THAN 7'-9" AND LESS THAN 12'-3" L** GREATER OR EQUAL THAN 11'-3" ROOF HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE POSITIVE NEGATIVE (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. 0' - 15' 76.4 45.8 102.4 61.4 73.0 43.8 95.5 57. 3 68.5 4 7. 1 86.4 51.8 > 15'-20' 80.4 48.2 107.6 64.6 76.8 46.1 100.4 60.2 72.0 43.2 90.8 54.5 > 20'-25' 83.6 50.2 111.9 67.1 79.8 47.9 104.4 52.6 74.8 44.9 94.4 56.6 > 25'-30 86.2 51.7 115.5 69.3 82.4 49.4 107.7 64.6 77.3 46.4 97.4 58.4 > 3o'-40' 90.7 54.4 121.4 72.8 86.6 52.0 113.3 68.0 81.2 48.7 102.4 61.4 > 40'-50' 94.3 56.6 126.2 75.7 90.0 54.0 117.7 70.6 84.4 50.6 106.5 63.9 > 50'-s0' 97.3 58.4 130.3 78.2 92.9 55.7 121.5 72.9 87.2 52.3 109.9 65.9 BUILDING'S PEAK ROOF HEIGHT vs DESIGN W/ND PRESSURE FOR COMPONENTS A CLADDING (P S F) FOR ASCE 7-10 - PEAK ROOF HEIGHT GREATER THAN 60 FEET �k BASIC WIND SPEED = 170 mph RISK CATEGORY II BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) PEAK ROOF L** LESS THAN 12-3" L** GREATER OR EQUAL THAN 12'-3" HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. > 60' - 70' 91.5 54.9 167.7 100.6 84.3 50.6 148.4 89.0 > 70' - 80' 93. 6 56.2 171.6 103.0 86.2 5 7. 7 151.9 91.1 > 80' - 90' 95.6 57.4 175.2 105.1 88.0 52.8 755.0 93.0 > 90' - 100' 97.3 58.4 178.4 107.4 89.7 53.8 157.9 94.7 > 100' - 120' 100.5 60.3 184.2 110.5 92.5 55.5 163.0 97.8 > 120' - 140' 103.2 61.9 189.2 113.5 5.1 57.1 167.4 100.4 > 140' - 160' 7 05. 6 63. 4 193. 6 116.2 97.3 58.4 171.3 102.8 > 160' - 180' 107.8 64.7 197.6 118.6 99.3 59.6 174.9 104.9 > 180' - 200' 109.8 65.9 201.3 120.8 101.1 60.7 178.1 106.9 > 200' - 250' 114.1 68.5 209.2 125.5 105.2 63.1 185.1 111.1 > 250' - 300' 117.8 70.1 216.0 129.E 108.5 65.1 191.1 114.7 > 300' - 350' 121.0 72.6 221.9 133. 1 111.5 66.9 196.3 117.8 0' - 400' 123.9 74.3 227.1 136.3 114.1 68.5 200.9 120.5 L>400' - 450' 126.4 75.8 231.8 139.1 116.5 69.9 205.1 123.1 0' - 5oo' 128.8 77.3 236. 1 141.7 118.E 71.2 208.9 125.3 N 1.) THIS CERTIFIED SIGNED AND SEALED WIND LOAD CHART, PREPARED BY THIS ENGINEER, BASED ON ASCE 7-10, FOR A BASIC WIND SPEED OF 170 MPH, AND APPLICABLE RISK CATEGORY BUILDING & EXPOSURES, IS COMPLETELY GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT. 2.) THIS WIND LOAD CHART MUST BE SIGNED, SEALED AND DATED BY THIS ENGINEER IF USED TO OBTAIN A ONE TIME BUILDING PERMIT 3.) CONTRACTOR OR PERMIT HOLDER TO BE RESPONSIBLE FOR THE SELECTION OF DESIGN WIND PRESSURE BASED ON THIS GENERIC WIND LOAD CHART. WIND PRESSURES ARE ULTIMATE AND A.S.D. PRESSURES. 4.) THIS WIND LOAD CHART SHALL BE CONSIDERED INVALID IF ALTERED BY ANY MEANS. 5.) DESIGN WIND LOAD SELECTED BY THE CONTRACTOR OR PERMIT HOLDER FROM THIS WIND LOAD CHART SHALL BE INDICATED ON A SEPARATE DOCUMENT PREPARED BY THE CONTRACTOR OR PERMIT HOLDER (e.g., SPREADSHEET OPENING SCHEDULE/TAKE OFF SHEET, ETC.). * INDICATED DESIGN WIND PRESSURES CORRESPOND TO THE MAXIMUM END ZONE AND INTERIOR ZONE CONDITIONS AND FOR ALL ROOF SLOPES. ak �C L = STORM PANEL LENGTH, ACCORDION SHUTTER BLADE LENGTH OR BAHAMA SHUTTER HEIGHT PRODUCTS WHICH BEAR A MIAMI-DADS COUNTY OR A STATE OF FLORIDA APPROVAL Tk \C ENs�; =* No. 44167 STATE of 2mZ� r %ss/OIV A L ENGN� "z ��Irllll11111111� 2017 (6th EDITION) FLORIDA BUILDING CODE - BROWARD, PALM BEACH, MARTIN, ST. LUCIE & INDIAN RIVER COUNTIES