Loading...
HomeMy WebLinkAboutPermit WorksheetMobile Home Permit Worksheet Application Number: Installer: EDDIEGRUNDEL License # IH 1118467 Address of home I nr v w p `yv being Installed / Manufacturer JACOBSEN Lengthxwidth ,�e5)(50 NOTE. if home is a single wide fill out one half of the blocking plan if home is a triple or quad wide sketch in remainder of home I understand Lateral Arm Systems cannot be used on any home (new or used) where the sidewall ties exceed 5 ft 4 in. Installer's initials EG Typical pier spacing 7 ZI 6r / lateral r LLL��� �� Show locations of Longitudinal and Lateral Systems longitudinal (use dark lines to show these locations) (.. ------------------- ------------- mn ---------------- Q--------- 2' of end of home New Home ❑✓ Used Home ❑ Home installed to the Manufacturers Installation Manual Home is installed in accordance with Rule 15-C Single wide ❑ Wind Zone II ❑ Wind Zone III Double wide ❑✓ Installation Decal # TBD Triple/Quad ❑ Serial # TBD PIER SPACING TABLE FOR USED HOMES e Load bearing capacity Footer size (sq in) 16" x 16" (256) 18 1/2" x 18 1/2'(342) 20" x 20" (400) 22" x 22" (484)' 24" X 24" (576)' 26" x 26" (676) 1000 Dsf 3' 4' 1 V 6' 7 8' 1500 s 4' 6 6 7 8 8 8' 2000 at 6' 8 8 8' 8 8 2500 s 7' 6' 8' 1 8 8' 8 8' 3000 psf 8' 6 8' 8 8 8' 3500 Pat I 8 8'1 8' 1 8 I8 6 ' interpolated from Rule tot» pier spacing ladle. PIER PAD SIZES I-beam pier pad size 17X22.5 Perimeter pier pad size 16X16 Other pier pad sizes (required by the mfg.) Draw the approximate locations of marriage I wall openings 4 fool or greater. Use this . .r symbol to show the piers. List all marriage wall openings greater than 4 foot and their pier pad sizes below. Opening Pier pad size 23X31 17X22.5 2-3 23X31 TIEDOWNCOMPONENTS Longitudinal Stabilizing Device (LSD) Manufacturer OLIVER Longitudinal Stabilizing Device w/ Lateral Arms Manufacturer ANCHORS 4ft ✓ 5ft FRAME TIES within 2' of end of hc-- spaced at 5' 4" oc ✓ OTHER TIES Number Sidewall Longitudinal Marriage wall Shearwall E Mobile Home Permit Worksheet Application Number: Date: POCKET PENETROMETER TEST The pocket penetrometer tests are rounded down to 1500 . _ psf or check hereto declare 1000 lb. soil _._ without testing. X 1_500 X 1,500 X 1,500 POCKET PENETROMETER TESTING METHOD 1. Test the perimeter of the home at 6 locations. 2. Take the reading at the depth of the Tooter. 3. Using 500 lb. increments, take the lowest reading and round down to that increment. X 1,500 X 1,500 X 1,500 TORQUE PROBE TEST The results of the torque probe test is 295 inch pounds or check here if you are declaring 5' anchors without testing ,_ _. A test showing 275 inch pounds or less will require 5 foot anchors. Note: A state approved lateral arm system is being used and 4 ft. anchors are allowed at the sidewall locations. I understand 5 ft anchors are required at all centerline tie points where the torque test reading is 275 or less and where the mobile home manufacturer may requires anchors with 4000 lb holding rapacity. Installer's initials ALL TESTS MUST BE PERFORMED BY A LICENSED INSTALLER Installer Name EDDIEGRUNDEL ;trical conductors between multi -wide units, but not to the main power includes the bonding wire between mull -wide units. Pg. sewer drains to an existing sewer tap or septic tank. Pg. Site Preparation Debris and organic material removed YEs Water drainage: Natural __. ,. Swale _ Pad X _ _ _ . Other Fastening multi wide units Floor: Type Fastener: LAGLength: s Spacing: 24"_ Walls: Type Fastener: LAG Length: 6" _ _ _ Spacing: 24"____.____._. Roof: Type Fastener..)_AG_ ..._ . Length. CON'T_ Spacing: 24 _ S" For used homes a min. 30 gauge, wide, galvanized metal strip will be centered over the peak of the roof and fastened with galy. roofing nails at 2" on center on both sides of the centerline. Gasket (n'eatherprooflng requirement) I understand a properly installed gasket is a requirement of all new and used homes and that condensation, mold, meldew and buckled marriage walls are a result of a poorly installed or no gasket being installed. I understand a strip of tape will not serve as a gasket. Installer's initials Type gasket FACTORY Installed: Pg. _ _ _ Between Floors Yes X Between Walls Yes X _ Bottom of ridgebeam Yes Weatherproofing The bottomboard will be repaired and/or taped. Yes X , Pg. Siding on units is installed to manufacturer's specifications. Yes X Fireplace chimney installed so as not to allow intrusion of rain water. Yes X Miscellaneous ' Skirting to be installed. Yes X __ No Dryer vent installed outside of skirting. Yes xN/A Range downflow vent installed outside of skirting. Yes .X._____ N/A Drain lines supported at 4 foot intervals. Yes X Electrical crossovers protected. Yes X_ Other: Installer verifies all information given with this permit worksheet is accurate and true based on the manufacturer's installation instructions and or Rule 15C-1 $ 2 Connect all potable water supply piping to an existing water meter, water tap, or other Installer Signature/A // ^„ Yam. /1 /1 Date independent water supply systems. Pg. lJ/OJ(%U,{�/ 4!//`ifjr`G�`/ // /�/