HomeMy WebLinkAboutProduct Approval s
CREEK Certificate of Authorization No.29824
17520 Edinburgh Dr
Tampa,FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE,6T"EDITION(2017)
Manufacturer: DREXEL METALS, INC. Issued October 9,2018
1234 Gardiner Lane
Louisville,KY 40213
(502)716-7143
www.drexmet.com
Manufacturing: Drexel Metals Association of Regional Manufacturers(DM-ARM)
Quality Assurance: Architectural Testing, Inc.(QUA1844)
SCOPE
Category: Roofing
Subcategory: Metal Roofing
Code Sections: 1504.3
Properties: Wind Resistance
REFERENCES
Entity Report No. Standard Year
Architectural Testing(TST1558) 56840.02-122-18 TAS 100 1995
Architectural Testing(TST1558) 58389.01-122-44 UL 580 2006
Architectural Testing(TST1558) 58459.01-122-44 UL 580 2006
Architectural Testing(TST1558) 58461.01-122-44 TAS 125 2003
Architectural Testing(TST1558) 82776.01-109-44 UL%580 2006
UL 1897 2012
Architectural Testing(TST1558) 82784.01-109-44 UL 580 2006
UL 1897 2012
Architectural Testing(TST1558) 83296.01-109-44 UL 580 2006
UL 1897 2012
Architectural Testing,Inc(an Intertek Company)(TST1527) H3245.01-450-18 TAS 125 2003
Architectural Testing,Inc(an Intertek Company)(TST1527) H9058.02-450-18 TAS 125 2003
Architectural Testing,Inc(an Intertek Company)(TST1527) H9058.01-450-18 TAS 125 2003
Architectural Testing,Inc(an Intertek Company)(TST1527) 13391.01-450-44 UL 580 2006
Force Engineering&Testing(TST5328) 178-0054T-12 UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 178-0055T-12 UL 580 2006
UL 1897 2012
Hurricane Test Laboratory(TST1527) 0287-0209-07 TAS 125 2003
Hurricane Test Laboratory(TST1527) 0287-0308-07 TAS 125 2003
Hurricane Test Laboratory(TST1527) 0287-0311-07 TAS 125 2003
Hurricane Test Laboratory(TST1527) 0287-0313-07 TAS 125 2003
Hurricane Test Laboratory(TST1527) 0287-0512-07 TAS 125 2003
'Hurricane Test Laboratory(TST1527) 0287-0706-07 TAS 125 2003
PRI Construction Materials Technologies(TST5878) VLS-005-02-01 ASTM B 117 2016
TAS 110 2000
PRI Construction Materials Technologies(TST5878) VLS-004-02-01 ASTM G 155 2005a
TAS 110 2000
PRI Construction Materials Technologies(TST5878) DMC-004-02-01 TAS 125 2003
PRI Construction Materials Technologies(TST5878) DMC-005-02-01 TAS 125 2003
PRI Construction Materials Technologies(TST5878) DMC-006-02-01 TAS 125 2003
PRI Construction Materials Technologies(TST5878) DMC-007-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) DMC-008-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) DMC-009-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) DMC-014-02-01 TAS 125 2003
PRI Construction Materials Technologies(TST5878) DMC-016-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) DMC-017-02-01 Rev 1 UL 580 2006
UL 1897 2012
DRX15001.6 FL17678-R6 Page 1 of 5
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
C RE E K DREXEL METALS,INC.
Metal Roofing
TECHNICAL SERVICES,LLC
Enti Report No. Standard Year
PRI Construction Materials Technologies(TST5878) DMC-018-02-01 UL 580 2006
UL 1897 2012
PRI Construction Materials Technologies(TST5878) DMC-024-02-01 UL 580 2006
UL 1897 2012
PRI Construction Materials Technologies(TST5878) DMC-033-02-01.1 UL 580 2006
UL 1897 2012
PRI Construction Materials Technologies(TST5878) DMC-037-02-01 UL 580 2006
UL 1897 2012
PRI Construction Materials Technologies(TST5878) DMC-037-02-02 UL 580 2006
UL 1897 2012
PRI Construction Materials Technologies(TST5878) DMC-038-02-01 UL 580 2006
UL 1897 2012
PRODUCTDESCRIPTION
DMC 100NS Profile: 1 in.snap lock seam;Max.16 in.coverage
Description: Non-structural,snap lock standing seam roof panel with integral perorated nail
strip
Material: Min.24 ga. Fluropon®coated ASTM A792 AZ50,or
ASTM A653 G90; Fy=min.50 ksi; Shall conform with FBC Section 1507.4.3
�s•
6 k O.C. i
DMC 150SL Profile: 1.5 in.snap lock seam; Max. 16 in.coverage
Description: Non-structural,snap lock standing seam roof panel
Material: Min.24 ga. Fluropon®coated ASTM A792 AZ50,or
ASTM A653 G90;F =min.50 ksi; Shall conform with FBC Section 1507.4.3
DRX15001.6 FL17678-R6 Page 2 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
CREEK DREXEL METALS,INC.
Metal Roofing
TECHNICAL SERVICES, LLC
DMC 15OSS Profile: 1.5 in.mechanical seam;Max. 16 in.coverage
Description: Non-structural,mechanical lock standing seam roof panel
Material: Min.0.032 in.Fluropon®coated ASTM B209 aluminum;Fy=min. 16 ksi; Shall
conform with FBC Section 1507.4.3
Min.24 ga. Fluropon®coated ASTM A792 AZ50,or ASTM A653 G90; Fy=min.
50 ksi; Shall conform with FBC Section 1507.4.3
8' -1
„ gg
p"
12' 1 '
1611
Material: Min.0.027 in.Zinc; Fy=min. 16 ksi; Shall conform with FBC Section 1507.4.3
15.7"
DMC 175S Profile: 1.75 in.snap lock seam; Max..18 in.coverage
Description: Non-structural,snap lock standing seam roof panel
Material: Min.0.032 in. Fluropon®coated ASTM B209 aluminum; Fy=min.24 ksi; Shall
conform with FBC Section 1507.4.3
Min.0.040-inch Fluropon®coated ASTM 8209 aluminum(Fy=min.20 ksi); Shall
conform with FBC Section 1507.4.3
• Min.24 ga. Fluropon®coated ASTM A792 AZ50,or
ASTM A653 090;F =min.50 ksi; Shall conform with FBC Section 1507.4.3
i
18"
DMC 200S Profile: 2 in.mechanical seam;Max. 16 in.coverage
Description: Non-structural,mechanical lock standing seam roof panel
Material: Min.0.040 in.Fluropon®coated ASTM B209 aluminum; Fy=min.20 ksi; Shall
conform with FBC Section 1507.4.3
Min.24 ga. Fluropon®coated ASTM A792 AZ50,or
ASTM A653 G90; F =min.50 ksi; Shall conform with FBC Section 1507.4.3
#„ T _T
2" 2"
�-- 16"
DRX15001.6 FL17678-R6 Page 3 of 5
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
GREEK DREXEL METALS,INC.
Metal Roofing
TECHNICAL SERVICES, LLC
DMC 450 Profile: 1.5 in.snap lock seam;Max. 16 in.coverage
Description: Non-structural,snap lock standing seam roof panel with concealed clip
Material: Min.24 ga.ASTM A792 or ASTM A653; Fy=min.50 ksi; Shall conform with FBC
Section 1507.4.3
Min.0.032 in.Fluropon®coated ASTM B209 aluminum; Fy=min.24 ksi; Shall
conform with FBC Section 1507.4.3
1 Z„
— 16"
DMC 5V Profile: 3/8 in.ribs;Min.21 in.,Max.24 in.coverage
Description: Non-structural,through fastened roof panel
Material: Min.26 ga.Fluropon@ coated ASTM A792 or ASTM A653 G90; Fy=min.50 ksi;
Shall conform:with FBC Section 1507.4.3
Min.0.032 in.?Fluropon®coated ASTM B209 aluminum; Fy=min.23 ksi; Shall
conform with FBC Section 1507.4.3
21"up to 24"-Coverage
—�
8
DMC Profile: 1/2 in.corrugation;21 in.coverage
Corrugated Description: Non-structural,through fastened roof panel
Material: Min.26 ga.Fluropon®coated ASTM A792 or ASTM A653 G90;Fy=min.40 ksi;
Shall conforrqwith FBC Section 1507.4.3
Min.0.032 in.Fluropon®coated ASTM 8209 aluminum; Fy=min.19 ksi; Shall
conform with FBC Section 1507.4.3
28„
i
. 2 !
7 „
2 =1�
DRX15001.6 FL17678-R6 Page 4 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
CREEK DREXEL METALS,INC.
Metal Roofing
TECHNICAL SERVICES, LLC
LIMITATIONS
1. Fire classification is not within the scope of this evaluation.
2. This report is not for use in the HVHZ.
3. The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
4. Roof slope shall be in accordance with FBC Section 1507.4.2.
5. Reroofing shall be in accordance with FBC Section 1511.
6. Installation of the evaluated products shall comply with this report, the FBC and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and FBC compliant installation detail shall prevail.
7. All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code,6"'Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer.
♦����u a l�iii�i
`' Pc E N F�Fs�•�� 2018.10.09
No 74021 - 11-:21 :46
�= -0400'
'33'.• STATE OF :44/
�0��•'c� O R t O P' ���` Zachary R..Priest,P.E.
C'> Zachary
Florida Organization No.ANE96 1on No. 021
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R:Priest, P.E.does not have, nor will acquire,a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
APPENDICES
1) APPENDIX A—Installation(12 pages)
2) APPENDIX B—Approved Roof Systems(8 pages)
3) APPENDIX C—Design Wind Loads(4 pages)
DRX16001.6 FL17678-R6 Page 5 of 5
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK DREXEL METALS,INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX A
INSTALLATION
Note-Refer to the APPROVED ROOF SYSTEMS section of this report for specific installation details of a selected system.
Unless otherwise specified in this report the following installation details shall be met for the named products:
Component Product Installation Detail
#9-15 HWH wood screw
with sealing washer
#10-14 HWH wood screw
with sealing washer Shall penetrate through the sheathing a_minimum 3/8 in. Must be corrosion
#10-15 HWH wood resistant in accordance with FBC section 1507.4.4.
Fasteners screws with dual threads
and sealing washer
#10-13 PH wood screw
#10-16 DP3 PH self-
drilling screw Shall penetrate through the top rib of the steel deck a minimum 3/4 in. Must be
#14-13 DP1 PH self- corrosion resistant in accordance with FBC section 1507.4.4.
drilling screw
Bearing Plates 18 ga.Bearing Plate 3n
® \
24 ga.in-seam clip yy
DMC 150SL Clip
Clips 24 ga.SS in-seam clip
y 7n
O
24 ga.DMC 150SS Clip 3. T- 0 10
8
o T
3n o Z
i
DRX15001.6 Fl17678-R6 Page 1 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
• l
CREEK DREXEL METALS,INC.
Metal Roofing
TECHNICAL SERVICES,LLC APPENDIX A
Component Product Installation Detail
24 ga.in-seam Gip
t167
24 ga.DMC 150SS Fixed & gTClip a
1s
26 ga.in-seam clip
26 ga.DMC 15OSS Fixed
Clip
22 ga.SS in-seam clip
1 �
Clips(Cont'd) 22 ga.DMC 15OSS Clip aw T o
ef7
0
r"
22 ga.in-seam clip
G 18'
22 ga.DMC 15OSS Fixed 7o
Clip a" T o
0
sr
22 ga.base;24 ga.butterfly in-seam clip
DMC 150SS Butterfly
Clip
1 518"
DRX15001.6 FL17678-R6 Page 2 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
CREEK DREXEL METALS,INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX A
Component Product Installation Detail
22 ga.base;24 ga.butterfly in-seam clip
�!1
DMC 150SS Continuous i
Butterfly Clip
�6/fir
26 ga.in-seam clip
DMC 150SS Utility o
Floating P Cli
f
Clips(Cont'd) V
18 ga.in-seam clip
DMC 175S UL Clip
c O
22 ga.SS in-seam clip
1 L77
+. TDMC 200S Clip Q
/ W
DRX15001.6 FL17678-R6 Page 3 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
L_
i
CD E E K DREXEL METALS,INC.
j� Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX A
Component Product Installation Detail
18 ga.base;22 ga.butterfly in-seam clip;4.5 in.length
DMC 200S Butterfly Clip
e�
18 ga.base;22 ga.butterfly in-seam clip;120 in.length;top slider 12 in.o.c.
DMC 200S Continuous �f
Butterfly Clip
Clips(Cont'd).
24 ga.in-seam clip
DMC 450 Clip
24 ga.SS in-seam clip
DMC 450SS Clip
m
Sealants Bostik 70-05A Shall be applied in continuous beads along the seam
Bostik Chem-Calk 915
Fastening Details
Nomenclature Attachment
DMC 10ONS PANEL --
#10 - 13 PHW
DMC 100NS Standard ,
DRX15001.6 FL17678-R6 Page 4 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
I
CREEK DREXEL METALS,INC.
Metal Roofing
TECHNICAL SERVICES, LLC APPENDIX A
Component Product Installation Detail
DMC 100NS PANEL
- - BOSTIK 70-05A(2 - 3/16" BEADS)
'f ---#10 - 13 PHW
DMC 100NS Enhanced f'
DMC 150SL PANEL
DMC 150SL CLIP
#10-13PHW(2Per Clip)—
LINDERLAYMENT \�
DMC 150SL Standard
s
DMC 15OSS PANEL
DMC 150SS CONTINUOUS BUTTERFLY,CLIP
(2)#10-13 PHW
i UNDERLAYMENT
DMC 150SS Continuous I SUBSTRATE
Butterfly
DMC 15OSS PANEL
DMC 150SS BUTTERFLY CLIP
(2)#10-13 PHW—�
UNDERLAYMENT
SUBSTRATE
DMC 15OSS Butterfly
DRX15001.6 FL17678-R6 Page 5 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical'Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
P Y
CREEK DREXEL METALS,INC.
Metal Roofing
TECHNICAL SERVICES, LLC APPENDIX A
Component Product Installation Detail
DMC 15OSS PANEL
DMC 150SS BUTTERFLY CLIP
(2)#14-13 PHDD
UNDERLAYMENT
3x3-18GA BEARING PLATE
ISO INSULATION
METAL DECK
DMC 15OSS#14 Butterfly
•'S. :.� amu,
DMC 150SS PANEL
24 GA DMC 150SS FIXED CLIP
(2)#10-13 PHW
UNDERLAYMENT
SUBSTRATE
DMC 15OSS Fixed-90
119'BEAD BOSTIK CHEM-CALK 915
j:jAPPUED TO BOTH SIDES OF CUP
DMC 15OSS PANEL
24 GA DMC 150SS FIXED CUP
116'BEAD BOSTIK CHEMCALK 9-
APPUED TO BOTH SIDE OF CLIP
DMC 15OSS#14 Fixed-
96
2 #14-13 DP1,PH Screws per clip;Clip installed over 18 ga.bearing late
DMC 150SS PANEL
24 GA DMC 150SS CLIP
(2)#10-13 PHW
UNDERLAYMENT
DMC 15OSS Standard(Al) SUBSTRATE
DRX15001.6 FL17678-R6 Page 6 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
i
GREEK DREXEL METALS,INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX A
Component Product Installation Detail
1/4"BEAD BOSTIK 70-05A
DMC 15OSS PANEL
22 GA DMC 150SS FIXED CLIP
DMC 150SS Fixed (2)#10-13 PHW
Enhanced-90 UNDERLAYMENT
SUBSTRATE
DMC 15OSS PANEL
22 GA DMC 150SS FIXED CLIP
(2)#10-13PHW
UNDERLAYMENT
DMC 15OSS Fixed .s SUBSTRATE
Enhanced-180
1/4"BEAD BOSTIK 70-05A—\
DMC 15OSS PANEL
22 GADMC 150SS CLIP
(2)#10-13 PHW
DMC 150S$Enhanced(Al) UNDERLAYMENT
SUBSTRATE
DRX15001.6 FL17678-R6 Page 7 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
CREEK DREXEL METALS,INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX A
Component Product Installation Detail
DMC 150SS PANEL—
DMC 150SS CLIP
(2)#10-13 PH Screws—
UNDERLAYMENT
DMC 15OSS Zinc SUBSTRATE
DMC 175S Panel
DMC 1155 UL CUP
Screw- - N10-13 PH Screw�
(2)per clip
DMC 175S#10 Standard
DMC 1755 Panel
DMC 175S UL Clip
010-13 PH Screw—
(2)
(2)per dip
114•BEAD BOSTIK CHEM-CALK
915 MALE LEG AND BOTH SIDES
OF CLIP ~
118'BEAD BOSTIK CHEM-CALK
DMC 175S#10 Enhanced 913 ON FEMALE LEG_ \
DRX15001.6 FL17678-R6 Page 8 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
70"
C RE E K DREXEL METALS,INC.
Metal Roofing
0 TECHNICAL SERVICES, LLC
APPENDIX A
Component Product Installation Detail
DMC 1755 PANEL
DMC 1765 UL CLIP
014-13 DPI PHDD(2 Per CAp)
3X3-1SGA BEARING PLATE
METAL DECK
]�ISD INSULATION
DMC 175S#14 Standard
1
DMC 200S PANEL
DMC 200S BUTTERFLY CLIP
(2)#10-13 PHW
UNDERLAYMENT
SUBSTRATE
DMC 200S Buttedly
DMC 200.S PANEL--\
DMC 200S BUTTERFLY CLIP
#10--16 DP3 PHD
UNDERLAYMENT
METAL DECK
DMC 200S Butterfly(Steel)
Use 18 ga.bearing plate over polyisocyanurate insulation
DRX15001.6 FL17678-R6 Page 9 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
CREEK DREXEL METALS,INC.
Metal Roofing
TECHNICAL SERVICES,LLC APPENDIX A
Component Product Installation Detail
DMG200S'PANEL
DMC 200S CONTINOUS
BUTTERLY CLIP
#10 - 1.6 DP3 PHD'
UNDERLAYMENT
METAL DECK
DMC 200S Continuous
Butterfly(Steel)
Use 18 ga.bearing late over polyisocyanurate insulation
DMC 200S PANEL
DMC 200S CLIP
(2)#10-13 PHW
UNDERLAYMENT
TRA
DMC 200S Fixed SUBSTE
1/4"BEAD BOSTIK 70-05A
DMC 200S PANEL
DMC 200S CLIP
DMC 200$Fixed (2)#10-13 PHW
Enhanced- UNDERLAYMENT
SUBSTRATE
DRX15001.6 FL17678-R6 Page 10 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
CREEK DREXEL METALS,INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX A
Component Product Installation Detail
DMC 450 PANEL
DMC 450 CLIP
#10-13 PHW(2 Per Clip)
DMC 450 Standard
DMC 450 PANEL
DMC 450 SS CLIP
#10-13 PHW(2 Per Clip)
DMC 450SS Standard
�99.15 HM WOOD SCREW WITH
sexlrlc WASHER
DMC 5V Standard
#10-14 DREXMET WOODSCREW
DMC 5V PANEL
METSHIELD HT UNDERLAYMENT
PLYWOOD
DMC 5V#10 Standard,
P;
.DRX15001.6 FL17678-R6 Page 11 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
CREEK DREXEL METALS,INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX A
Component Product Installation Detail
DMC 5V PANEL
#10-14 DREXMET WOODSCREW — —
UNDERLAYMENT--- `
7116"OSB MIN. \
DMC 5V Pan Fastening
�—ONLY REQUIRED AT—
PANEL ENDS �\
V-9" COVERAGE
#10-15 HWH WOODSCREW(DUAL THREAD)
12"o.c. to 36"o.c. MAX. ROW SPACING
DMC Corrugated UNDERLAYMENT
15/32" MIN. PLYWOOD
DRX15001.6 FL17678-R6 Page 12 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
CRE�` DREXEL METALS,INC.
,EK Metal Roofing
TECHNICAL SERVICES, LLC
- -• - APPENDIX B
APPROVED ROOF SYSTEMS
Thefollowing,notes,shall be observed when-using the assembiy.tables._below,.
1. Maximum Design Pressure(MDP)was calculated using a 2:1 margin of safety per FBC Section 1504.9.
2. Refer to LimiT_ATiONs and sections of this evaluation when using-the table(s)below.
3. Refer to INSTALLATION section of-this report for installation detail when the information is not explicitly stated for the selected assembly.
4. The on-center(o.c.)spacing given is the maximum allowable attachment spacing for the.rated system.
5. Steel Deck shall be designed by.others in accordance with FBC requirements and shall be minimum 22 ga(FY=min.33 ksi)Wide Rib Deck(Type WR)
conforming to ANSI/SDI-RD1.0&FBC.
6. Wood Deck shall be designed by others in accordance with FBC requirements and shall be minimum 15/32-inch thick APA Span-Rated plywood
sheathing at maximum 24-inch span. "
Roof System Numbers and Definitions
100NS-W# DMC 100NS over Wood Deck New or Existing)
150SL-W# DMC 150SL over Wood Deck(New or Existing)
150SS-S# DMC 150SS over Steel Deck New or Existin
1505 -W# DMC 150SS over Wood Deck New.or Existing)
.175S-S# DMC 175S over Steel Deck New or.Existin
175S-W# DMC 175S over Wood Deck new or Existing)
_200S-Sff IDMC 200S over Steel Deck New or Existing)
20OS-W# DMC 200S over Wood Deck New or Existing)
450-W# DMC 450 over Wood Deck New or Existing)
5V-W# DMC 5V over Wood Deck New or Existing)
COR-W# DMC Corru ated over Wood Deck New or Existing)
Approved Systems for DMC 100NS over Wood Deck(New or Existing)
System Deck Fire Barrier Underlao. yment Roof Panel Panel Attachment Psi
100NS-W1 Min.15/32 OPTIONAL As required per FBC 24 ga.DMC 100NS DMC 100NS Standard attachment -97.5
CDX plywood Versashield Solo Max.16-inch wide with fastener spaced 10.5 in.o.c.
Min.15/32 OPTIONAL 24 ga.DMC 100NS DMC 100NS Standard attachment
100NS-W2 CDX plywood Versashield Solo As required per FBC Max.16-inch wide with fasteners spaced 5.25 in.o.c. -120
Min. 15/32 OPTIONAL 24 ga.DMC 100NS DMC 100NS Enhanced attachment
100NS-W3 CDX plywood Versashield Solo As required per FBC Max.16-inch wide with fasteners spaced 5.25 in.o.c. -135
DRX15001.6 FL17678-R6 Page 1 of 8
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEKY DREXEL METALS,INC.
Metal Roofing
TECHNICAL,SERVICES, LLC
APPENDIX B
Approved Systems for DMC 150SL over Wood Deck(New or Existing)
SysDeck Fire Barrier Underlao. yment Roof Panel Panel Attachment D
Min.-15/32--- OPTIONAL - 24 ga.DMC 150SL DMC 150SL Standard attachment
150SL-W1 CDX I As required per FBC -52.5
plywood Versashield Solo. Max. 16-inch wide with clips spaced 16 in.o.c.
A roved S stems for DMC 150SS over Steel Deck New of Existin
System Deck Fire Barrier Insulation Underlayment Roof Panel Panel Attachment MDP
No. (psf)
Min.22 ga. Min. 1 in.Approved 24 ga.DMC 150SS DMC 150SS#14 Butterfly attachment
150SS-S1' .•Type B, As required polyisocyanurate As-required per FBC -41.7
Grade 80 Steel insulation board Max. 16-inch wide with clips spaced 36 in.o.c.
Min.22 ga. Min.1 in.Approved Approved ASTM D 24 ga.DMC 150SS DMC 150SS#14 Fixed-90 attachment
150SS-S2 Type B, As required polyisocyanurate -71
Grade 80 Steel insulation board 1970 underlayment Max.16-inch wide with clips spaced 16 in.o.c.
Min.22 ga. Min.1 in.Approved 24 ga.DMC 150SS DMC 150SS#14 Butterfly attachment
150SS-S3 Type B, As required polyisocyanurate As required per FBC -92.4
Grade 80 Steel insulation board Max.16-inch wide with clips spaced 24 in.o.c.
Min.22 ga. Min.1 in.Approved 24 ga.DMC 150SS DMC 150SS#14 Butterfly attachment
150SS-S4 Type B, As required polyisocyanurate As required per FBC -117.8
Grade 80 Steel insulation board Max.16-inch wide with clips spaced 18 in.o.c.
Min.22 ga. Min.1 in.Approved 24 ga.DMC 150SS DMC 150SS#14 Butterfly attachment
150SS-S5 Type B, As required polyisocyanurate As required per FBC -143.1
Grade 80 Steel insulation board Max.16-inch wide with clips spaced 12 in.o.c.
Min.22 ga. Min.1 in.Approved 24 ga.DMC 150SS DMC 150SS#14 Butterfly attachment
150SS-S6 Type B, As required polyisocyanurate As required per FBC -168.5
Grade 80 Steel insulation board Max.16-inch wide with clips spaced 6 in.o.c.
DRX15001.6 FL17678-R6 Page 2 of 8
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other
product attributes that are not specifically addressed herein.
CD E E DREXEL METALS,INC.
[� _ Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX B
Approved Systems for DMC 150SS over Wood Deck(New or Existing)
System Deck __.Fire Barrier-,_ Underla ment Roof Panel Panel Attachment MDP
No. _ _ .: Y _ (psf)
Min.15/32 OPTIONAL Approved ASTM D 0.027'(0.7mm)Zinc DMC 150SS DMC150SS Zinc attachment
150SS-W1 CDX plywood Versashield Solo App underlayment Max.15.7-inch wide with DMC 150SS Utility Floating Clips -78.5
180°seam spaced 18 in.o.c.
Mina 15/32 OPTIONAL Approved ASTM D 0.027"(0.7mm)Zinc DMC 150SS DMC150SS Zinc attachment
1.5.OSS-W2.... CDX plywood Versashield Solo App underlayment Max.15.7-inch wide. with DMC 150SS Utility Floating Clips -86
180°seam spaced 6 in.o.c.
Min.15/32 OPTIONAL Approved ASTM D 0.027'(0.7mm)Zinc DMC 150SS DMC150SS Zinc attachment
150SS-W3 CDX plywood Versashield Solo App underlayment Max..15.7-inch wide. with 26 ga.DMC 150SS Fixed Clips spaced -86
180°seam 18 in.o.c.
0.032"AI DMC 16OSS
150SS-W4 Min..15/32 OPTIONAL As required per FBC Max.16-inch wide DMC 150SS Standard(Al)attachment -90
CDX plywood Versashield Solo 180"seam with clips spaced 16 in.o.c.
24 ga.DMC 150SS
150SS-W5 Min.plywood
OPTIONAL As required per FBC Max.16-inch wide DMC 150SS Fixed-90 attachment -90
CDX pllywood Versashield Solo 90°seam with clips spaced 16 in.o.c.
DMC 150SSa.
Min.15/32 OPTIONAL 24 gDMC 150SS Butterfly attachment
150SS-W6 CDX plywood Versashield Solo As required per FBC Max.16-inch wide with clips spaced 16 in.o.c. -99.25
180"seam
Min.15/32 OPTIONAL Approved ASTM D 0.027'(0.7mm)Zinc DMC 150SS DMC150SS Zinc attachment
150SS-W7 CDX plywood Versashield Solo 1970 underlayment Max.15.7-inch wide with 26 ga.DMC 150SS Fixed Clips spaced -108.5
180"seam 9 in.o.c.
Min.15/32 OPTIONAL 24 ga.DMC 150SS DMC 150SS Continuous Butterfly
150SS-W8 CDX plywood Versashield Solo As required per FBC Max.16-inch wide attachment with fasteners spaced 12 in.o.c. -114.25
180°seam
Min.15/32 OPTIONAL 24 ga.DMC 150SS DMC 150SS Fixed Enhanced-90
150SS-W9 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide attachment -150
Min.90"seam with clips spaced 12 in.o.c.
Min. 15/32 OPTIONAL 24 ga.DMC 150SS DMC 150SS Fixed Enhanced-180
150SS-W10 CDX plywood Versashield Solo As required per FBC Max.16-inch wide attachment -165
Min.180"seam with clips spaced 8 in.o.c.
DRX15001.6 FL17678-R6 Page 3 of 8
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other
product attributes that are not specifically addressed herein.
CD t E K DREXEL METALS,INC.
j't j� Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX B
Approved Systems for DMC 150SS over Wood Deck(New or Existing)
System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
No. (psf)
0.032'AI DMC 150SS
Min..]5132._.._.—.-_OPTIONAL _ A
____ _ . As-required FBC
DMC 150SS Enhanced(Al)attachment
150SS-W1 1 CDX plywood Versashield Solo s requper '- Max.16-inch wide 180°seam with clips spaced 8 in.o.c. -180
A roved S stems for DMC 175S over Steel Deck New or Existing)
System Deck Fire Barrier Insulation Underlayment Roof Panel Panel Attachment MDP
No. (psf)
Min. 1 in.Approved
_ Min.22 ga. 24 ga.DMC 175S DMC 175S#14 Standard attachment
175S-S1 As required polyisocyanurate. As required per FBC -60
Type B Steel Max. 18=inch wide with clips spaced 36 in.o.c.
insulation board
Min. 1 in.Approved
Min.22 ga. 0.040"Al DMC 175S DMC 175S#14 Standard attachment
175S-S2 As required polyisocyanurate As required per FBC -88
Type B Steel insulation board Max.17.5-inch wide with clips spaced 18 in.o.c.
Min.22 ga. Min.1 in.Approved 24 ga.DMC 175S DMC 175S#14 Standard attachment
175S-S3 As required polyisocyanu rate As required per FBC -105
Type B Steel insulation board Max.18-inch wide with clips spaced 6 in.o.c.
Min. 1 in.Approved
Min.22 ga. 0.040"Al DMC 175S DMC 175S#14 Standard attachment
175S-S4 Type B Steel As required polyisocyanurate As required per FBC Max.17.5-inch wide with clips spaced 12 in.o.c. -129.25
insulation board
Approved Systems for DMC 175S over Wood Deck(New or Existing)
System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
No. (psf)
Min. 15/32 OPTIONAL 0.032"Al DMC 175S DMC 175S#10 Standard attachment
175S-Wl CDX plywood Versashield As required per FBC Max.18-inch wide with clips spaced 24 in.o.c. -52.5
Solo
Min.15/32 OPTIONAL 0.032"AI DMC 1755 DMC 175S#10 Standard attachment
175S-W2 CDX plywood Versashield As required per FBC Max.18-inch wide with clips spaced 18 in.o.c. -59.4
Solo
DRX15001.6 FL17678-R6 Page 4 of 8
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other
product attributes that are not specifically addressed herein.
CREEK DREXEL METALS,INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX B
Approved Systems for DMC 175S over Wood Deck(New or Existing)
System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
No. (psf)
Min.15/32 OPTIONAL 0.032"AI DMC 175S DMC 175S#10 Standard attachment
175S-W3 CDX plywood Versashield As required per FBC Max.18-inch wide with clips spaced 12 in.o.c. -66.4
Solo
Min.15/32 OPTIONAL 0.032"AI DMC 175S DMC 175S#10 Standard attachment
175S-W4 CDX plywood Versashield As required per FBC Max.18-inch wide with clips spaced 8 in.o.c. -71
Solo -
Min
olo .
Min.15/32 OPTIONAL_ __ _. _ 0.032"AI DMC 175S DMC 175S#10 Enhanced attachment
175S-W5 CDX plywood Versashield Approved ASTM D 1970 undedayment Max.18-inch wide with clips spaced 12 in.o.c. -71
Solo
ASTM D 226,Type II roofing felt attached per
Min.15/32 _ 1518.2.1 with nails and tin caps per 1517.5 0.032"AI DMC 175S DMC 175S#10 Standard attachment
175S-W6 CDX plywood followed by Metshield High-Temp Max.18-inch wide with clips spaced 24 in.o.c. -74.75
Underlayment self-adFieied to felt
Min.-15/32 OPTIONAL 0.032"AI DMC 175S DMC 175S#10 Standard attachment
175S-W7 CDX plywood Versashield As required per FBC Max. 14-inch wide with clips spaced 12 in.o.c. -82.5
Solo
Min.15/32 OPTIONAL 24 ga.DMC 175S DMC 175S#10 Standard attachment
175S-W8 CDX plywood Versashield As required per FBC Max.18-inch wide with clips spaced 16 in.o.c. -84.25
Solo
Min.19/32 24 ga.DMC 175S DMC 175S#10 Standard attachment
175S-W9 OPTIONAL CDX I Versashield As required per FBC -97.5
plywood Solo Max.16-inch wide with clips spaced 25 in.o.c.
OPTIONAL
Min.15/32 0.040"AI DMC 175S DMC 175S#10 Standard attachment
175S-W10 CDX plywood Versashield As required per FBC Solo Max.17.5-inch wide with clips spaced 18 in.o.c. -106.75
Min.15/32 OPTIONAL 24 ga.DMC 175S DMC 175S#10 Standard attachment
175S-W11 CDX plywood Versashield As required per FBC Max.18-inch wide with clips spaced 8 in.o.c. -121.75
Solo
ASTM D 226,Type II roofing felt attached per
175S-W12 Min.15/32 - 1518.2.1 with nails and tin caps per 1517.5 0.032"AI DMC 175S DMC 175S#10 Standard attachment -131
CDX plywood followed by Metshield High-Temp Max.18-inch wide with clips spaced 6 in.o.c.
Underlayment self-adhered to felt
Min.19/32 OPTIONAL 24 ga.DMC 175S DMC 175S#10 Standard attachment
175S-W13 CDX plywood Versashield As required per FBC Max.16-inch wide with clips spaced 8 in.o.c. -135
Solo
DRX15001.6 FL17678-R6 Page 5 of 8
This evaluation report.is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other
product attributes that are not specifically addressed herein.
GD E E K DREXEL METALS,INC.
[� Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX B
Approved Systems for DMC 200S over Steel Deck New or Existing)
SyNttem ... -. •- Deck - Fire Barrier Insulation Underlayment Roof-Panel Panel Attachment PDO
Min.1 in.Approved 24 ga.DMC 200S
Min.22 ga. -- --�--.--- - - DMC 200S Butterfly(Steel)attachment
200S-S1 As required polyisocyanurate As required per FBC Max. 16-inch wide -88
Type B Steel insulation board 180°seam with clips spaced 24 in.o.c.
24 ga.DMC 200S
200S-S2 Min.22 ga. As required None As required per FBC Max. 16-inch wide DMC 200S Butterfly(Steel)attachment _g1.75
Type B Steel 180°seam with clips spaced 24 in.o.c.
Min22 gaMin.1 in.Approved 24 ga.DMC 200S DMC 200S Continuous Butterfly(Steel)
2 . .00S-S3 As required polyisocyanurate As required per FBC Max. 16-inch wide -121.75
Type B Steel insulation board 180°seam attachment with clips spaced 12 in.o.c.
Min.22 ga. 24 ga.DMC 200S DMC 200S Continuous Butterfly(Steel)
200S-S4 ' Type B Steel As required None As required per FBC Max.16-inch wide 180°seam attachment with clips spaced 12 in.o.c. -151.75
Approved Systems for DMC 200S over Wood'Deck(New or Existing)
System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
No. (psf)
20OS-W1 Min.plywood
24 ga.DMC 200S OPTIONAL As required per FBC Max.16-inch wide DMC 200S Butterfly attachment -67.5
CDX pllywood Versashield Solo 180°seam with clips spaced 24 in.o.c.
200S-W2 Min.plywood
0.040"AI DMC 200S OPTIONAL As required per FBC Max.16-inch wide DMC 200S Butterfly attachment -75
CDX pllywood Versashield Solo 180°seam with clips spaced 24 in.o.c.
200S-W3 Min.plywood
0.040"Al DMC 200S OPTIONAL As required per FBC Max.16-inch wide DMC Fixed attachment -105
CDX pllywood Versashield Solo 180°seam with cllipsips spaced 16 in.o.c.
200S-W4 Min.plywood
0.040"AI DMC 200S OPTIONAL As required per FBC Max.16-inch wide DMC with Fixed Enhanced attachment -180
CDX pllywood Versashield Solo 180°seam with clips spaced 8 in.o.c.
DRX15001.6 FL17678-R6 Page 6 of 8
This evaluation reportis provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other
product attributes that are not specifically addressed herein.
CREEKDREXEL METALS,INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX B
Approved Systems for DMC 450 over Wood Deck(New or Existing)
System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
No. - ...._....-.__.._. ..__ ._ .-. (psf)
450-W1 Min.19/32 OPTIONAL As required per FBC 24 ga.DMC 450 DMC 450 Standard attachment -30
CDX plywood Versashield Solo Max.16-inch wide with clips spaced 24 in.o.c.
Min.15/32 OPTIONAL 0.032"AI DMC 450 DMC 450SS Standard attachment
450-W2 As required per FBC -45
COX plywood "Versa"shield Solo - Max.16-inch wide with clips spaced 16 in.o.c.
450-W3 Min.19/32 OPTIONAL As required per FBC 24 ga.DMC 450 DMC 450 Standard attachment -67.5
CDX plywood Versashield Solo Max.16-inch wide with clips spaced 15.5 in.o.c.
Min.15/32 OPTIONAL 0.032"AI DMC 450 DMC 450SS Standard attachment
450-W4 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide with clips spaced 6 in.o.c. -75
450-W5 ,. Min.19/32 OPTIONAL As required per FBC 24 ga.DMC 450 DMC 450 Standard attachment _82 5
CDX plywood Versashield Solo Max. 16-inch wide with clips spaced 6 in.o.c.
Approved Systems for DMC 5V over Wood Deck(New or Existing)
System Deck Fire Barrier/ Underlayment Roof Panel Panel Attachment MDP
No. Insulation (psf)
OPTIONAL
ASTM D 226,Type II roofing felt attached per 0.037'AI DMC 5V
DMC 5V#10 Standard attachment
Min.15/32 1518.2.1 with nails and tin caps per 1517.5 Min.21-inch to
5V-W1 Approved fire barrier with#10-14 HWH wood screws with -56
CDX plywood or insulation followed by Metshield High-Temp Max.24-inch sealing washers spaced 18 in.o.c.
Underlayment self-adhered to felt coverage
26 ga.DMC 5V
OPTIONAL DMC 5V Standard attachment
Min.15/32
5V-W2 CDX plywood Approved fire barrier As required per FBC Max.24-inch Min.21-inch to with#9-15 HWH wood screws with -60
or insulation coverage sealing washers spaced 16 in.o.c.
OPTIONAL
ASTM D 226,Type II roofing felt attached per, 26 ga.DMC 5V
DMC 5V#10 Standard attachment
Min. 15/32 1518.2.1 with nails and tin caps per 1517.5 Min.21-inch to
5V-W3 CDX plywood Approved fire barrier followed by Metshield High-Temp Max.24-inch with HWH wood screws with -71
or insulation Underlayment self-adhered to felt coverage seallinging washers spaced 24 in.o.c.
DRX15001.6 FL17678-R6 Page 7 of 8
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK DREXEL METALS,INC.
Metal Roofing
TECHNICAL,SERVICES, LLC
APPENDIX B
Approved Systems for DMC 5V over Wood Deck(New or Existing)
System Deck Fire Barrier/ Underlayment Roof Panel Panel Attachment MDP
No. Insulation (psf)
26 ga.DMC 5V
OPTIONAL DMC 5V Pan Fastening attachment
5V-W4 .- Min.7/16 OSB .Approved fire barrier-------• As required per FBC Min.21-inch to with#10-14 HWH wood screws with -75
plywood or insulation Max.24 inch sealing washers spaced 16 in.o.c.
coverage
26 ga.DMC 5V
OPTIONAL DMC 5V Pan Fastening attachment
plywood 5V-W5 Min.ywo od OSB Approved fire barrier As required per FBC Max.24 inch Min.21-inch h with#10-14 HWH wood screws with -112.5
orinsulation sealing washers spaced 8 in.o.c.
coverage
26 ga.DMC 5V
OPTIONAL DMC 5V Standard attachment
Min.15/32
5V-W6 CDX plywood Approved fire barrier As required per FBC Max.24-inch Min.21-inch to with#9-15 HWH wood screws with -121.75
or insulation sealing washers spaced 8 in.o.c.
coverage
ASTM D 226,Type II roofing felt attached per -26 ga.DMC 5V or
OPTIONAL 0.032"AI DMC 5V DMC 5V#10 Standard attachment
Min.15/32 1518.2.1 with nails and tin caps per 1517.5
5V-W7 Approved fire barrier Min.21-inch to with#10-14 HWH wood screws with -206
CDX plywood or insulation followed by Metshield High-Temp Max.24-inch sealing washers spaced 6 in.o.c.
Underlayment self-adhered to felt
coverage
Approved Systems for DMC Corrugated over Wood Deck(New or Existing)
System Deck Fire Barrier/ Underlayment Roof Panel Panel Attachment MDP
No. Insulation (psf)
Min.15/32 OPTIONAL 0.032"Al DMC Corrugated DMC 5V Corrugated attachment
COR-W1 CDX plywood Approved fire barrier As required per FBC Max.21-inch coverage with#10-15 HWH wood screws with dual threads -60
or insulation and sealing washer spaced 36 in.o.c.
Min.15/32 . OPTIONAL 26 ga.DMC Corrugated DMC 5V Corrugated attachment
COR-W2 CDX plywood Approved fire barrier As required per FBC Max.21-inch coverage with#10-15 HWH wood screws with dual threads -60
or insulation and sealing washer spaced 36 in.o.c.
Min.15/32 OPTIONAL 0.032°AI DMC Corrugated DMC 5V Corrugated attachment
COR-W3 CDX plywood Approved fire barrier As required per FBC Max.21-inch coverage with#10-15 HWH wood screws with dual threads -135
or insulation and sealing washer spaced 12 in.o.c.
Min. 15/32OPTIONAL 26 ga.DMC Corrugated DMC 5V Corrugated attachment
COR-W4 CDX plywood Approved fire barrier As required per FBC Max.21-inch coverage with#10-15 HWH wood screws with dual threads -150
or insulation and sealing washer spaced 12 in.o.c.
DRX15001.6 FL17678-R6 Page 8 of 8
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other
product attributes that are not specifically addressed herein.
CREEK DREXEL METALS,INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX C
DESIGN WIND LOADS
The following tables provide design wind loads for components and cladding in accordance with Section 1609 of the FBC and ASCE 7-10 under the following
provisions:
1. For Hip roofs between 2:12 and 5.6:12,Zone 3 shall be treated as Zone 2.
2. Wind speeds for risk category I, II, III,and IV buildings shall be as defined in Section 1609 of the FBC.
3. Exposure B,C,and D shall be as defined in section 1609 of the FBC.
4. Design wind load provided only for gable/hip roofs with roof slopes between 2:12 and 6.1:12
5. All calculations are based on an effective wind area of 10-ft2 or less.
6. Topographic factors such as escarpments or hills have been excluded from the analysis
7. Overhangs have been excluded from the analysis.
8. Wind directionality factor,Kd=0.85
9. Vuit is shown in the tables below. Design wind loads are calculated using Vasd=Vult110.6 per 1609.3.1.
10. Projects with mean roof heights greater than 60-ft shall be evaluated by a licensed design professional
11. Zones 1,2,and 3 shall be defined as shown below. Dimension"a"shall be 10%of the least horizontal dimension or(0.4 x Mean Roof Height),whichever
is smaller,but not less than either 4%of the least horizontal dimension or 3ft
Gable- Hip
N
a _
3 2 3 3 2 3 a \ 3 2 3 a
2 1 2 2 1 2 2 1 2 2 1 2
_ 1
3 2 3 131 2 1 31 a 3 2 3 a
lal lalal lal lal lal
DRX15001.6 FL17678-R6 Page 1 of 4
This evaluation report.is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other
product attributes that are not specifically addressed herein.
GD E E K DREXEL METALS,INC.
jZ Metal Roofing
TECHNICAL SERVICES,LLC
APPENDIX C
Gable/Hip Roofs in Exposure B Roof slope between 2:12 and 6.1:12
Building
- - Mean -- Basic Wind S eed m h
Type Zone HeR hof tt 120 130 140 150 160 170 180 190 200
20 -14.2 -16.7 -19.3 -22.2 -25.3 -28.5 -32.0 -35.6 -39.5
25 -14.2 -16.7 -19.3 -22.2 -25.3 28.5 -32.0 -35.6 -39.5
30 -14.2 -16.7 -19.3 -22.2 -25.3 -28.5 -32.0 -35.6 -39.5
_ ..............._ . ._ 40_.. _.__.._1.5.4._.._.... -18.1 ___21..0 _ -24.1 -27.4 -31.0 -34.7 1 -38.7 -42.9
50 -16.5 -19.3 -22.4 -25.7 -29.2 -33.0 -37.0 -41.2 -45.7
60 -17.3 -20.3 -23.5 -27.0 -30.7. - -34.6 -38.8 -43.3 -47.9
20 -24.7 -29.0 -33.7 -38.7 -44.0 -49.7 -55.7 -62.0 -68.7
25 -24.7 -29.0 -33.7 -38.7 -44.0 -49.7 -55.7 -62.0 -68.7
Enclosed 2 30 -24.7 -29.0 -33.7 -38.7 -44.0 -49.7 -55.7 -62.0 -68.7
40 _------26.9......,...........31.5 -36.6 -42.0 -47.8_._ .._. .-53.9 -60.4 -67.3 -74.6
50 -28.6 -33.6 -39.0 -44.7 -50.9 -57.5 -64.4 -71.8 -79.5
60 -30.0 -35.3 -40.9 -46.9 -53.4 -60.3 -67.6 -75.3 -83.5
20 -36.6 -42.9 . -49.8 -57.2 -65.0 -73.4 -82.3 -91.7 -101.6
25 -36.6 -42.9 -49.8 . -57:2. -65.0 -73.4 -82.3 -91.7 -101.6
3 30 -36.6 -42.9 -49.8 -57.2 -65.0 -73.4 -82.3 -91.7 -101.6
40 -39.7 -46.6 -54.1 -62.1 -70.6 -79.7 -89.4 -99.6 -110.3
50 -42.3 -49.7 -57.6 -66.2 -75.3 -85.0 -95.3 -106.1 -117.6
60 -44.4 -52.1 -60.5 -69.4 -79.0 -89.2 -100.0 -111.4 -123.4
20 -19.1 -22.4 -26.0 -29.8 -33.9 -38.3 -42.9 -47.8 -53.0
25 -19.1 -22.4 -26.0 -29.8 -33.9 -38.3 -42.9 -47.8 -53.0
1 30 -19.1 -22.4 -26.0 -29.8 -33.9 -38.3 -42.9 -47.8 -53.0
40 -20.7 -24.3 -28.2 -32.4 -36.8 -41.6 -46.6 -51.9 -57.6
50 -22.1 -25.9 -30.1 -34.5 -39.3 -44.3 -49.7 -55.4 -61.3
60 -23.2 -27.2 -31.5 -36.2 -41.2 -46.5 -52.1 -58.1 -64.4
20 -29.6 -34.8 -40.3 -46.3 -52.6 -59.4 -66.6 -74.2 -82.3
25 -29.6 -34.8 -40.3 -46.3 -52.6 -59.4 -66.6 -74.2 -82.3
Partially 30 -29.6 -34.8 -40.3 -46.3 -52.6 -59.4 -66.6 -74.2 -82.3
Enclosed 2 40 -32.2 -37.7 -43.8 -50.2 -57.2 -64.5 -72.3 -80.6 -89.3
50 -34.3 -40.2 -46.6 -53.5 -60.9 -68.8 -77.1 -85.9 -95.2
60 -36.0 -42.2 -48.9 -56.2 -63.9 -72.2 -80.9 -90.1 -99.9
20 -41.5 -48.7 -56.4 -64.8 -73.7 -83.2 -93.3 -103.9 -115.2
25 -41.5 -48.7 -56.4 -64.8 -73.7 -83.2 -93.3 -103.9 -115.2
3 30 -41.5 48.7 -56.4 -64.8 -73.7 -83.2 -93.3 -103.9 -115.2
40 -45.0 -52.8 -61.3 -70.3 -80.0 -90.3 -101.3 -112.8 -125.0
50 -48.0 -56.3 -65.3 -75.0 -85.3 -96.3 -107.9 -120.3 -133.3
60 -50.3 -59.1 -68.5 -78.7 -89.5 -101.0 -113.3 -126.2 -139.8
DRX15001.6 FL17678-R6 - Page 2 of 4
This evaluation report is.provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other
product attributes that are not specifically addressed herein.
G REEK DREXEL METALS,INC.
IMMetal Roofing
TECHNICAL SERVICES, LLC
APPENDIX C
Gable/Hip Roofs in Exposure C Roof slope between 2:12 and 6.1:12
Building
Mean _. -. _._._...._.. Basic Wind Speed m h
Type Zone He ofttht 120 130 140 150 160 170 180 190 200
20 -18.3 -21.4 -24.9 -28.6 -32.5 -36.7 -41.1 -45.8 -50.8
25 -19.1 -22.4 -26.0 -29.8 -33.9 -38.3 -42.9 -47.9 -53.0
1 30 -19.9 -23.4 -27.1 -31.1 -35.4 -39.9 -44.8 -49.9 -55.3
40 _-._21.1 __._.. _..__724.8 -28.7 -33.0 .. -37.5 -42.4 -47.5 1 -52.9 -58.7
50 -22.1 -26.0 -30.1 -34.6 -39.4 -44.4 -49.8 -55.5 -61.5
60 -22.9 -26.9 -31.2 -35.9 -40.8 -46.1 -51.6 -57.5 -63.7
20 -31.8 -37.3 -43.3 -49.7 -56.6 -63.8 -71.6 -79.8 -88.4
25 -33.2 -39.0 -45.2 -51.9 -59.1 -66.7 -74.8 -83.3 -92.3
Enclosed 2 30 -34.6 -40.7 -47.2 -54.1 -61.6 -69.5 -77.9 -86.8 -96.2
40 - -36.8 -43.1.. -50.0 -57.4 - -65.4 -73.8 -82.7 -92.2 -102.1
50 -38.5 -45.2 -52.4 -60.2 -68.5 -77.3 -86.7 -96.6 -107.0
60 -39.9 -46.9 -54.4 -62.4 -71.0 -80.2 -89.9 -100.1 -111.0
20 -47.0 -55.2 -64.0 -73.5. . -83.6 -94.4 -105.8 -117.9 -130.7
.25 -49.1 -57.7 -66.9 -76.8 787.3 -98.6 -110.5 -123.2 -136.5
3 30 -51.2 -60.1 -69.7 -80.0 -91.1 -102.8 -115.3 -128.4 -142.3
40 -54.4 -63.8 -74.0 -84.9 -96.6 -109.1 -122.3 -136.3 -151.0
50 -57.0 -66.9 -77.5 -89.0 -101.3 -114.3 -128.2 -142.8 -158.3
60 -59.1 -69.3 -80.4 -92.3 -105.0 -118.5 -132.9 -148.1 -164.1
20 -24.5 -28.8 -33.4 -38.3 -43.6 -49.2 -55.2 -61.5 -68.2
25 -25.6 -30.1 -34.9 -40.0 -45.6 -51.4 -57.7 -64.2 -71.2
1 30 -26.7 -31.4 -36.4 -41.7 -47.5 -53.6 -60.1 -67.0 -74.2
40 -28.4 -33.3 -38.6 -44.3 -50.4 -56.9 -63.8 -71.1 -78.8
50 -29.7 -34.9 -40.5 46.4 -52.8 -59.6 -66.9 -74.5 -82.5
60 -30.8 -36.2 -41.9 -48.1 -54.8 -61.8 -69.3 -77.2 -85.6
20 -38.1 -44.7 -51.8 -59.5 -67.7 -76.4 -85.7 -95.4 -105.8
25 -39.8 -46.7 -54.1 -62.1 -70.7 -79.8 -89.5 -99.7 -110.5
Partially 30 -41.5 -48.7 -56.4 -64.8 -73.7 -83.2 -93.3 -103.9 -115.2
Enclosed 2 40 -44.0 -51.6 -59.9 -68.7 -78.2 -88.3 -99.0 -110.3 -122.2
50 -46.1 -54.1 -62.8 -72.0 -82.0 -92.5 -103.8 -115.6 -128.1
60 -47.8 -56.1 -65.1 -74.7 -85.0 -95.9 -107.6 -119.8 -132.8
20 -53.3 -62.6 -72.6 -83.3 -94.8 -107.0 -119.9 -133.6 -148.1
25 -55.7 -65.3 -75.8 -87.0 -99.0 -111.7 -125.3 -139.6 -154.6
3 30 -58.0 -68.1 -79.0 -90.7 -103.2 -116.5 -130.6 -145.5 -161.2
40 -61.6 -72.3 -83.8 -96.2 -109.5 -123.6 -138.6 -154.4 -171.1
50 -64.6 -75.8 -87.9 -100.9 -114.8 -129.6 -145.2 -161.8 -179.3
60 -66.9 -78.5 -91.1 -104.6 -119.0 -134.3 -150.6 -167.8 -185.9
DRX15001.6 FL17678-R6 Page 3 of 4
This evaluation report.is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other
product attributes that are not specifically addressed herein.
a' I
CREEK DREXEL METALS,INC.
Metal Roofing
TECHNICAL SERVICES,LLC
APPENDIX C
Gable/Hip Roofs in Exposure D Roof slope between 2:12 and 6.1:12
Building
- - Mean Basic Wind Speed m h
Type Zone HeR hof tt 120 130 140 150 160 170 180 190 200
20 -21.9 -25.7 -29.9 -34.3 -39.0 -44.0 -49.3 -55.0 -60.9
25 -22.7 -26.7 -31.0 -35.5 -40.4 -45.6 -51.2 -57.0 -63.2
1 30 -23.6 -27.6 -32.1 -36.8 -41.9 -47.3 -53.0 -59.1 -65.4
_ ................__. 40 --.724.8-- .-29.1 ...33.7 -38.7 .. -44.0 -49.7 -55.7 -62.1 -68.8
50 -25.8 -30.3 -35.1 -40.3 .. -45.9 -51.8 -58.0 -64.6 -71.6
60 -26.6 -31.2 -36.2 -41.6 -47.3 -53.4 -59.9 -66.7 -73.9
20 -38.2 44.8 -52.0 -59.7 -67.9 -76.6 -85.9 -95.7 -106.0
25 -39.6 46.5 -53.9 -61.9 -70.4 -79.5 -89.1 -99.2 -110.0
Enclosed 2 30 -41.0 48.1 -55.8 -64.1 -72.9 -82.3 -92.3 -102.8 -113.9
.40 ---743.1-. -. -50.6 -58.7 -67.4... -76.7_ -86.5 -97.0 -108.1 -119.8
50 -44.9 -52.7 -61.1 -70.1 -79.8 -90.1 -101.0 -112.5 -124.7
60 -46.3 -54.3 -63.0 -72.4 -82.3 -92.9 -104.2 -116.1 -128.6
20 -56.5 -66.3 776.8. -88.2. -100.4 -113.3 -127.0 -141.5 -156.8
25 -58.5 -68.7 -79.7 -91.5 -104.1. -117.5 -131.7 -146.8 -162.6
8 30 -60.6 -71.2 -82.5 -94.7 -107.8 -121.7 -136.4 -152.0 -168.4
40 -63.8 -74.8 -86.8 -99.6 -113.4 -128.0 -143.5 -159.9 -177.1
50 -66.4 -77.9 -90.4 •-103.7 -118.0 -133.2 -149.4 -166.4 -184.4
60 -68.5 -80.4 -93.2 -107.0 -121.7 -137.4 -154.1 -171.7 -190.2
20 -29.4 -34.6 -40.1 -46.0 -52.3 -59.1 -66.3 -73.8 -81.8
25 -30.5 -35.8 -41.6 -47.7 -54.3 -61.3 -68.7 -76.5 -84.8
1 30 -31.6 -37.1 -43.0 -49.4 -56.2 -63.5 -71.2 -79.3 -87.8
40 -33.3 -39.0 -45.3 -52.0 -59.1 -66.8 -74.8 -83.4 -92.4
50 -34.6 -40.6 -47.1 -54.1 -61.6 -69.5 -77.9 -86.8 -96.2
60 -35.7 41.9 -48.6 -55.8 -63.5 -71.7 -80.4 -89.5 -99.2
20 -45.7 -53.6 -62.2 -71.4 -81.2 -91.7 -102.8 -114.5 -126.9
25 -47.4 -55.6 -64.5 -74.0 -84.2 -95.1 -106.6 -118.8 -131.6
Partially 30 -49.1 -57.6 -66.8 -76.7 -87.2 -98.5 -110.4 -123.0 -136.3
Enclosed 2 40 -51.6 -60.6 -70.2 -80.6 -91.8 -103.6 -116.1 -129.4 -143.4
50 -53.7 -63.1 -73.1 -83.9 -95.5 -107.8 -120.9 -134.7 -149.2
60 -55.4 -65.0 -75.4 -86.6 -98.5 -111.2 -124.7 -138.9 -153.9
20 -64.0 -75.1 -87.1 -99.9 -113.7 -128.4 -143.9 -160.3 -177.7
25 -66.3 -77.8 -90.3 -103.6 -117.9 -133.1 -149.2 -166.3 -184.3
3 30 -68.7 -80.6 -93.5 -107.3 -122.1 -137.9 -154.6 -172.2 -190.8
40 -72.3 -84.8 -98.3 -112.9 -128.5 -145.0 -162.6 -181.1 -200.7
50 -75.2 -88.3 -102.4 -117.5 -133.7 -151.0 -169.2 -188.6 -208.9
60 -77.6 -91.1 -105.6 -121.2 -137.9 -155.7 -174.6 -194.5 -215.5
DRX15001.6 FL17678-R6 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other
product attributes that are not specifically addressed herein.