Loading...
HomeMy WebLinkAboutProduct Approval s CREEK Certificate of Authorization No.29824 17520 Edinburgh Dr Tampa,FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,6T"EDITION(2017) Manufacturer: DREXEL METALS, INC. Issued October 9,2018 1234 Gardiner Lane Louisville,KY 40213 (502)716-7143 www.drexmet.com Manufacturing: Drexel Metals Association of Regional Manufacturers(DM-ARM) Quality Assurance: Architectural Testing, Inc.(QUA1844) SCOPE Category: Roofing Subcategory: Metal Roofing Code Sections: 1504.3 Properties: Wind Resistance REFERENCES Entity Report No. Standard Year Architectural Testing(TST1558) 56840.02-122-18 TAS 100 1995 Architectural Testing(TST1558) 58389.01-122-44 UL 580 2006 Architectural Testing(TST1558) 58459.01-122-44 UL 580 2006 Architectural Testing(TST1558) 58461.01-122-44 TAS 125 2003 Architectural Testing(TST1558) 82776.01-109-44 UL%580 2006 UL 1897 2012 Architectural Testing(TST1558) 82784.01-109-44 UL 580 2006 UL 1897 2012 Architectural Testing(TST1558) 83296.01-109-44 UL 580 2006 UL 1897 2012 Architectural Testing,Inc(an Intertek Company)(TST1527) H3245.01-450-18 TAS 125 2003 Architectural Testing,Inc(an Intertek Company)(TST1527) H9058.02-450-18 TAS 125 2003 Architectural Testing,Inc(an Intertek Company)(TST1527) H9058.01-450-18 TAS 125 2003 Architectural Testing,Inc(an Intertek Company)(TST1527) 13391.01-450-44 UL 580 2006 Force Engineering&Testing(TST5328) 178-0054T-12 UL 580 2006 UL 1897 2012 Force Engineering&Testing(TST5328) 178-0055T-12 UL 580 2006 UL 1897 2012 Hurricane Test Laboratory(TST1527) 0287-0209-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-0308-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-0311-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-0313-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-0512-07 TAS 125 2003 'Hurricane Test Laboratory(TST1527) 0287-0706-07 TAS 125 2003 PRI Construction Materials Technologies(TST5878) VLS-005-02-01 ASTM B 117 2016 TAS 110 2000 PRI Construction Materials Technologies(TST5878) VLS-004-02-01 ASTM G 155 2005a TAS 110 2000 PRI Construction Materials Technologies(TST5878) DMC-004-02-01 TAS 125 2003 PRI Construction Materials Technologies(TST5878) DMC-005-02-01 TAS 125 2003 PRI Construction Materials Technologies(TST5878) DMC-006-02-01 TAS 125 2003 PRI Construction Materials Technologies(TST5878) DMC-007-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) DMC-008-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) DMC-009-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) DMC-014-02-01 TAS 125 2003 PRI Construction Materials Technologies(TST5878) DMC-016-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) DMC-017-02-01 Rev 1 UL 580 2006 UL 1897 2012 DRX15001.6 FL17678-R6 Page 1 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. C RE E K DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES,LLC Enti Report No. Standard Year PRI Construction Materials Technologies(TST5878) DMC-018-02-01 UL 580 2006 UL 1897 2012 PRI Construction Materials Technologies(TST5878) DMC-024-02-01 UL 580 2006 UL 1897 2012 PRI Construction Materials Technologies(TST5878) DMC-033-02-01.1 UL 580 2006 UL 1897 2012 PRI Construction Materials Technologies(TST5878) DMC-037-02-01 UL 580 2006 UL 1897 2012 PRI Construction Materials Technologies(TST5878) DMC-037-02-02 UL 580 2006 UL 1897 2012 PRI Construction Materials Technologies(TST5878) DMC-038-02-01 UL 580 2006 UL 1897 2012 PRODUCTDESCRIPTION DMC 100NS Profile: 1 in.snap lock seam;Max.16 in.coverage Description: Non-structural,snap lock standing seam roof panel with integral perorated nail strip Material: Min.24 ga. Fluropon®coated ASTM A792 AZ50,or ASTM A653 G90; Fy=min.50 ksi; Shall conform with FBC Section 1507.4.3 �s• 6 k O.C. i DMC 150SL Profile: 1.5 in.snap lock seam; Max. 16 in.coverage Description: Non-structural,snap lock standing seam roof panel Material: Min.24 ga. Fluropon®coated ASTM A792 AZ50,or ASTM A653 G90;F =min.50 ksi; Shall conform with FBC Section 1507.4.3 DRX15001.6 FL17678-R6 Page 2 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES, LLC DMC 15OSS Profile: 1.5 in.mechanical seam;Max. 16 in.coverage Description: Non-structural,mechanical lock standing seam roof panel Material: Min.0.032 in.Fluropon®coated ASTM B209 aluminum;Fy=min. 16 ksi; Shall conform with FBC Section 1507.4.3 Min.24 ga. Fluropon®coated ASTM A792 AZ50,or ASTM A653 G90; Fy=min. 50 ksi; Shall conform with FBC Section 1507.4.3 8' -1 „ gg p" 12' 1 ' 1611 Material: Min.0.027 in.Zinc; Fy=min. 16 ksi; Shall conform with FBC Section 1507.4.3 15.7" DMC 175S Profile: 1.75 in.snap lock seam; Max..18 in.coverage Description: Non-structural,snap lock standing seam roof panel Material: Min.0.032 in. Fluropon®coated ASTM B209 aluminum; Fy=min.24 ksi; Shall conform with FBC Section 1507.4.3 Min.0.040-inch Fluropon®coated ASTM 8209 aluminum(Fy=min.20 ksi); Shall conform with FBC Section 1507.4.3 • Min.24 ga. Fluropon®coated ASTM A792 AZ50,or ASTM A653 090;F =min.50 ksi; Shall conform with FBC Section 1507.4.3 i 18" DMC 200S Profile: 2 in.mechanical seam;Max. 16 in.coverage Description: Non-structural,mechanical lock standing seam roof panel Material: Min.0.040 in.Fluropon®coated ASTM B209 aluminum; Fy=min.20 ksi; Shall conform with FBC Section 1507.4.3 Min.24 ga. Fluropon®coated ASTM A792 AZ50,or ASTM A653 G90; F =min.50 ksi; Shall conform with FBC Section 1507.4.3 #„ T _T 2" 2" �-- 16" DRX15001.6 FL17678-R6 Page 3 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES, LLC DMC 450 Profile: 1.5 in.snap lock seam;Max. 16 in.coverage Description: Non-structural,snap lock standing seam roof panel with concealed clip Material: Min.24 ga.ASTM A792 or ASTM A653; Fy=min.50 ksi; Shall conform with FBC Section 1507.4.3 Min.0.032 in.Fluropon®coated ASTM B209 aluminum; Fy=min.24 ksi; Shall conform with FBC Section 1507.4.3 1 Z„ — 16" DMC 5V Profile: 3/8 in.ribs;Min.21 in.,Max.24 in.coverage Description: Non-structural,through fastened roof panel Material: Min.26 ga.Fluropon@ coated ASTM A792 or ASTM A653 G90; Fy=min.50 ksi; Shall conform:with FBC Section 1507.4.3 Min.0.032 in.?Fluropon®coated ASTM B209 aluminum; Fy=min.23 ksi; Shall conform with FBC Section 1507.4.3 21"up to 24"-Coverage —� 8 DMC Profile: 1/2 in.corrugation;21 in.coverage Corrugated Description: Non-structural,through fastened roof panel Material: Min.26 ga.Fluropon®coated ASTM A792 or ASTM A653 G90;Fy=min.40 ksi; Shall conforrqwith FBC Section 1507.4.3 Min.0.032 in.Fluropon®coated ASTM 8209 aluminum; Fy=min.19 ksi; Shall conform with FBC Section 1507.4.3 28„ i . 2 ! 7 „ 2 =1� DRX15001.6 FL17678-R6 Page 4 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES, LLC LIMITATIONS 1. Fire classification is not within the scope of this evaluation. 2. This report is not for use in the HVHZ. 3. The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 4. Roof slope shall be in accordance with FBC Section 1507.4.2. 5. Reroofing shall be in accordance with FBC Section 1511. 6. Installation of the evaluated products shall comply with this report, the FBC and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 7. All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code,6"'Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer. ♦����u a l�iii�i `' Pc E N F�Fs�•�� 2018.10.09 No 74021 - 11-:21 :46 �= -0400' '33'.• STATE OF :44/ �0��•'c� O R t O P' ���` Zachary R..Priest,P.E. C'> Zachary Florida Organization No.ANE96 1on No. 021 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R:Priest, P.E.does not have, nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. APPENDICES 1) APPENDIX A—Installation(12 pages) 2) APPENDIX B—Approved Roof Systems(8 pages) 3) APPENDIX C—Design Wind Loads(4 pages) DRX16001.6 FL17678-R6 Page 5 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES, LLC APPENDIX A INSTALLATION Note-Refer to the APPROVED ROOF SYSTEMS section of this report for specific installation details of a selected system. Unless otherwise specified in this report the following installation details shall be met for the named products: Component Product Installation Detail #9-15 HWH wood screw with sealing washer #10-14 HWH wood screw with sealing washer Shall penetrate through the sheathing a_minimum 3/8 in. Must be corrosion #10-15 HWH wood resistant in accordance with FBC section 1507.4.4. Fasteners screws with dual threads and sealing washer #10-13 PH wood screw #10-16 DP3 PH self- drilling screw Shall penetrate through the top rib of the steel deck a minimum 3/4 in. Must be #14-13 DP1 PH self- corrosion resistant in accordance with FBC section 1507.4.4. drilling screw Bearing Plates 18 ga.Bearing Plate 3n ® \ 24 ga.in-seam clip yy DMC 150SL Clip Clips 24 ga.SS in-seam clip y 7n O 24 ga.DMC 150SS Clip 3. T- 0 10 8 o T 3n o Z i DRX15001.6 Fl17678-R6 Page 1 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. • l CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES,LLC APPENDIX A Component Product Installation Detail 24 ga.in-seam Gip t167 24 ga.DMC 150SS Fixed & gTClip a 1s 26 ga.in-seam clip 26 ga.DMC 15OSS Fixed Clip 22 ga.SS in-seam clip 1 � Clips(Cont'd) 22 ga.DMC 15OSS Clip aw T o ef7 0 r" 22 ga.in-seam clip G 18' 22 ga.DMC 15OSS Fixed 7o Clip a" T o 0 sr 22 ga.base;24 ga.butterfly in-seam clip DMC 150SS Butterfly Clip 1 518" DRX15001.6 FL17678-R6 Page 2 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES, LLC APPENDIX A Component Product Installation Detail 22 ga.base;24 ga.butterfly in-seam clip �!1 DMC 150SS Continuous i Butterfly Clip �6/fir 26 ga.in-seam clip DMC 150SS Utility o Floating P Cli f Clips(Cont'd) V 18 ga.in-seam clip DMC 175S UL Clip c O 22 ga.SS in-seam clip 1 L77 +. TDMC 200S Clip Q / W DRX15001.6 FL17678-R6 Page 3 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. L_ i CD E E K DREXEL METALS,INC. j� Metal Roofing TECHNICAL SERVICES, LLC APPENDIX A Component Product Installation Detail 18 ga.base;22 ga.butterfly in-seam clip;4.5 in.length DMC 200S Butterfly Clip e� 18 ga.base;22 ga.butterfly in-seam clip;120 in.length;top slider 12 in.o.c. DMC 200S Continuous �f Butterfly Clip Clips(Cont'd). 24 ga.in-seam clip DMC 450 Clip 24 ga.SS in-seam clip DMC 450SS Clip m Sealants Bostik 70-05A Shall be applied in continuous beads along the seam Bostik Chem-Calk 915 Fastening Details Nomenclature Attachment DMC 10ONS PANEL -- #10 - 13 PHW DMC 100NS Standard , DRX15001.6 FL17678-R6 Page 4 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. I CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES, LLC APPENDIX A Component Product Installation Detail DMC 100NS PANEL - - BOSTIK 70-05A(2 - 3/16" BEADS) 'f ---#10 - 13 PHW DMC 100NS Enhanced f' DMC 150SL PANEL DMC 150SL CLIP #10-13PHW(2Per Clip)— LINDERLAYMENT \� DMC 150SL Standard s DMC 15OSS PANEL DMC 150SS CONTINUOUS BUTTERFLY,CLIP (2)#10-13 PHW i UNDERLAYMENT DMC 150SS Continuous I SUBSTRATE Butterfly DMC 15OSS PANEL DMC 150SS BUTTERFLY CLIP (2)#10-13 PHW—� UNDERLAYMENT SUBSTRATE DMC 15OSS Butterfly DRX15001.6 FL17678-R6 Page 5 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical'Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. P Y CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES, LLC APPENDIX A Component Product Installation Detail DMC 15OSS PANEL DMC 150SS BUTTERFLY CLIP (2)#14-13 PHDD UNDERLAYMENT 3x3-18GA BEARING PLATE ISO INSULATION METAL DECK DMC 15OSS#14 Butterfly •'S. :.� amu, DMC 150SS PANEL 24 GA DMC 150SS FIXED CLIP (2)#10-13 PHW UNDERLAYMENT SUBSTRATE DMC 15OSS Fixed-90 119'BEAD BOSTIK CHEM-CALK 915 j:jAPPUED TO BOTH SIDES OF CUP DMC 15OSS PANEL 24 GA DMC 150SS FIXED CUP 116'BEAD BOSTIK CHEMCALK 9- APPUED TO BOTH SIDE OF CLIP DMC 15OSS#14 Fixed- 96 2 #14-13 DP1,PH Screws per clip;Clip installed over 18 ga.bearing late DMC 150SS PANEL 24 GA DMC 150SS CLIP (2)#10-13 PHW UNDERLAYMENT DMC 15OSS Standard(Al) SUBSTRATE DRX15001.6 FL17678-R6 Page 6 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. i GREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES, LLC APPENDIX A Component Product Installation Detail 1/4"BEAD BOSTIK 70-05A DMC 15OSS PANEL 22 GA DMC 150SS FIXED CLIP DMC 150SS Fixed (2)#10-13 PHW Enhanced-90 UNDERLAYMENT SUBSTRATE DMC 15OSS PANEL 22 GA DMC 150SS FIXED CLIP (2)#10-13PHW UNDERLAYMENT DMC 15OSS Fixed .s SUBSTRATE Enhanced-180 1/4"BEAD BOSTIK 70-05A—\ DMC 15OSS PANEL 22 GADMC 150SS CLIP (2)#10-13 PHW DMC 150S$Enhanced(Al) UNDERLAYMENT SUBSTRATE DRX15001.6 FL17678-R6 Page 7 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES, LLC APPENDIX A Component Product Installation Detail DMC 150SS PANEL— DMC 150SS CLIP (2)#10-13 PH Screws— UNDERLAYMENT DMC 15OSS Zinc SUBSTRATE DMC 175S Panel DMC 1155 UL CUP Screw- - N10-13 PH Screw� (2)per clip DMC 175S#10 Standard DMC 1755 Panel DMC 175S UL Clip 010-13 PH Screw— (2) (2)per dip 114•BEAD BOSTIK CHEM-CALK 915 MALE LEG AND BOTH SIDES OF CLIP ~ 118'BEAD BOSTIK CHEM-CALK DMC 175S#10 Enhanced 913 ON FEMALE LEG_ \ DRX15001.6 FL17678-R6 Page 8 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 70" C RE E K DREXEL METALS,INC. Metal Roofing 0 TECHNICAL SERVICES, LLC APPENDIX A Component Product Installation Detail DMC 1755 PANEL DMC 1765 UL CLIP 014-13 DPI PHDD(2 Per CAp) 3X3-1SGA BEARING PLATE METAL DECK ]�ISD INSULATION DMC 175S#14 Standard 1 DMC 200S PANEL DMC 200S BUTTERFLY CLIP (2)#10-13 PHW UNDERLAYMENT SUBSTRATE DMC 200S Buttedly DMC 200.S PANEL--\ DMC 200S BUTTERFLY CLIP #10--16 DP3 PHD UNDERLAYMENT METAL DECK DMC 200S Butterfly(Steel) Use 18 ga.bearing plate over polyisocyanurate insulation DRX15001.6 FL17678-R6 Page 9 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES,LLC APPENDIX A Component Product Installation Detail DMG200S'PANEL DMC 200S CONTINOUS BUTTERLY CLIP #10 - 1.6 DP3 PHD' UNDERLAYMENT METAL DECK DMC 200S Continuous Butterfly(Steel) Use 18 ga.bearing late over polyisocyanurate insulation DMC 200S PANEL DMC 200S CLIP (2)#10-13 PHW UNDERLAYMENT TRA DMC 200S Fixed SUBSTE 1/4"BEAD BOSTIK 70-05A DMC 200S PANEL DMC 200S CLIP DMC 200$Fixed (2)#10-13 PHW Enhanced- UNDERLAYMENT SUBSTRATE DRX15001.6 FL17678-R6 Page 10 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES, LLC APPENDIX A Component Product Installation Detail DMC 450 PANEL DMC 450 CLIP #10-13 PHW(2 Per Clip) DMC 450 Standard DMC 450 PANEL DMC 450 SS CLIP #10-13 PHW(2 Per Clip) DMC 450SS Standard �99.15 HM WOOD SCREW WITH sexlrlc WASHER DMC 5V Standard #10-14 DREXMET WOODSCREW DMC 5V PANEL METSHIELD HT UNDERLAYMENT PLYWOOD DMC 5V#10 Standard, P; .DRX15001.6 FL17678-R6 Page 11 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES, LLC APPENDIX A Component Product Installation Detail DMC 5V PANEL #10-14 DREXMET WOODSCREW — — UNDERLAYMENT--- ` 7116"OSB MIN. \ DMC 5V Pan Fastening �—ONLY REQUIRED AT— PANEL ENDS �\ V-9" COVERAGE #10-15 HWH WOODSCREW(DUAL THREAD) 12"o.c. to 36"o.c. MAX. ROW SPACING DMC Corrugated UNDERLAYMENT 15/32" MIN. PLYWOOD DRX15001.6 FL17678-R6 Page 12 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. CRE�` DREXEL METALS,INC. ,EK Metal Roofing TECHNICAL SERVICES, LLC - -• - APPENDIX B APPROVED ROOF SYSTEMS Thefollowing,notes,shall be observed when-using the assembiy.tables._below,. 1. Maximum Design Pressure(MDP)was calculated using a 2:1 margin of safety per FBC Section 1504.9. 2. Refer to LimiT_ATiONs and sections of this evaluation when using-the table(s)below. 3. Refer to INSTALLATION section of-this report for installation detail when the information is not explicitly stated for the selected assembly. 4. The on-center(o.c.)spacing given is the maximum allowable attachment spacing for the.rated system. 5. Steel Deck shall be designed by.others in accordance with FBC requirements and shall be minimum 22 ga(FY=min.33 ksi)Wide Rib Deck(Type WR) conforming to ANSI/SDI-RD1.0&FBC. 6. Wood Deck shall be designed by others in accordance with FBC requirements and shall be minimum 15/32-inch thick APA Span-Rated plywood sheathing at maximum 24-inch span. " Roof System Numbers and Definitions 100NS-W# DMC 100NS over Wood Deck New or Existing) 150SL-W# DMC 150SL over Wood Deck(New or Existing) 150SS-S# DMC 150SS over Steel Deck New or Existin 1505 -W# DMC 150SS over Wood Deck New.or Existing) .175S-S# DMC 175S over Steel Deck New or.Existin 175S-W# DMC 175S over Wood Deck new or Existing) _200S-Sff IDMC 200S over Steel Deck New or Existing) 20OS-W# DMC 200S over Wood Deck New or Existing) 450-W# DMC 450 over Wood Deck New or Existing) 5V-W# DMC 5V over Wood Deck New or Existing) COR-W# DMC Corru ated over Wood Deck New or Existing) Approved Systems for DMC 100NS over Wood Deck(New or Existing) System Deck Fire Barrier Underlao. yment Roof Panel Panel Attachment Psi 100NS-W1 Min.15/32 OPTIONAL As required per FBC 24 ga.DMC 100NS DMC 100NS Standard attachment -97.5 CDX plywood Versashield Solo Max.16-inch wide with fastener spaced 10.5 in.o.c. Min.15/32 OPTIONAL 24 ga.DMC 100NS DMC 100NS Standard attachment 100NS-W2 CDX plywood Versashield Solo As required per FBC Max.16-inch wide with fasteners spaced 5.25 in.o.c. -120 Min. 15/32 OPTIONAL 24 ga.DMC 100NS DMC 100NS Enhanced attachment 100NS-W3 CDX plywood Versashield Solo As required per FBC Max.16-inch wide with fasteners spaced 5.25 in.o.c. -135 DRX15001.6 FL17678-R6 Page 1 of 8 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEKY DREXEL METALS,INC. Metal Roofing TECHNICAL,SERVICES, LLC APPENDIX B Approved Systems for DMC 150SL over Wood Deck(New or Existing) SysDeck Fire Barrier Underlao. yment Roof Panel Panel Attachment D Min.-15/32--- OPTIONAL - 24 ga.DMC 150SL DMC 150SL Standard attachment 150SL-W1 CDX I As required per FBC -52.5 plywood Versashield Solo. Max. 16-inch wide with clips spaced 16 in.o.c. A roved S stems for DMC 150SS over Steel Deck New of Existin System Deck Fire Barrier Insulation Underlayment Roof Panel Panel Attachment MDP No. (psf) Min.22 ga. Min. 1 in.Approved 24 ga.DMC 150SS DMC 150SS#14 Butterfly attachment 150SS-S1' .•Type B, As required polyisocyanurate As-required per FBC -41.7 Grade 80 Steel insulation board Max. 16-inch wide with clips spaced 36 in.o.c. Min.22 ga. Min.1 in.Approved Approved ASTM D 24 ga.DMC 150SS DMC 150SS#14 Fixed-90 attachment 150SS-S2 Type B, As required polyisocyanurate -71 Grade 80 Steel insulation board 1970 underlayment Max.16-inch wide with clips spaced 16 in.o.c. Min.22 ga. Min.1 in.Approved 24 ga.DMC 150SS DMC 150SS#14 Butterfly attachment 150SS-S3 Type B, As required polyisocyanurate As required per FBC -92.4 Grade 80 Steel insulation board Max.16-inch wide with clips spaced 24 in.o.c. Min.22 ga. Min.1 in.Approved 24 ga.DMC 150SS DMC 150SS#14 Butterfly attachment 150SS-S4 Type B, As required polyisocyanurate As required per FBC -117.8 Grade 80 Steel insulation board Max.16-inch wide with clips spaced 18 in.o.c. Min.22 ga. Min.1 in.Approved 24 ga.DMC 150SS DMC 150SS#14 Butterfly attachment 150SS-S5 Type B, As required polyisocyanurate As required per FBC -143.1 Grade 80 Steel insulation board Max.16-inch wide with clips spaced 12 in.o.c. Min.22 ga. Min.1 in.Approved 24 ga.DMC 150SS DMC 150SS#14 Butterfly attachment 150SS-S6 Type B, As required polyisocyanurate As required per FBC -168.5 Grade 80 Steel insulation board Max.16-inch wide with clips spaced 6 in.o.c. DRX15001.6 FL17678-R6 Page 2 of 8 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. CD E E DREXEL METALS,INC. [� _ Metal Roofing TECHNICAL SERVICES, LLC APPENDIX B Approved Systems for DMC 150SS over Wood Deck(New or Existing) System Deck __.Fire Barrier-,_ Underla ment Roof Panel Panel Attachment MDP No. _ _ .: Y _ (psf) Min.15/32 OPTIONAL Approved ASTM D 0.027'(0.7mm)Zinc DMC 150SS DMC150SS Zinc attachment 150SS-W1 CDX plywood Versashield Solo App underlayment Max.15.7-inch wide with DMC 150SS Utility Floating Clips -78.5 180°seam spaced 18 in.o.c. Mina 15/32 OPTIONAL Approved ASTM D 0.027"(0.7mm)Zinc DMC 150SS DMC150SS Zinc attachment 1.5.OSS-W2.... CDX plywood Versashield Solo App underlayment Max.15.7-inch wide. with DMC 150SS Utility Floating Clips -86 180°seam spaced 6 in.o.c. Min.15/32 OPTIONAL Approved ASTM D 0.027'(0.7mm)Zinc DMC 150SS DMC150SS Zinc attachment 150SS-W3 CDX plywood Versashield Solo App underlayment Max..15.7-inch wide. with 26 ga.DMC 150SS Fixed Clips spaced -86 180°seam 18 in.o.c. 0.032"AI DMC 16OSS 150SS-W4 Min..15/32 OPTIONAL As required per FBC Max.16-inch wide DMC 150SS Standard(Al)attachment -90 CDX plywood Versashield Solo 180"seam with clips spaced 16 in.o.c. 24 ga.DMC 150SS 150SS-W5 Min.plywood OPTIONAL As required per FBC Max.16-inch wide DMC 150SS Fixed-90 attachment -90 CDX pllywood Versashield Solo 90°seam with clips spaced 16 in.o.c. DMC 150SSa. Min.15/32 OPTIONAL 24 gDMC 150SS Butterfly attachment 150SS-W6 CDX plywood Versashield Solo As required per FBC Max.16-inch wide with clips spaced 16 in.o.c. -99.25 180"seam Min.15/32 OPTIONAL Approved ASTM D 0.027'(0.7mm)Zinc DMC 150SS DMC150SS Zinc attachment 150SS-W7 CDX plywood Versashield Solo 1970 underlayment Max.15.7-inch wide with 26 ga.DMC 150SS Fixed Clips spaced -108.5 180"seam 9 in.o.c. Min.15/32 OPTIONAL 24 ga.DMC 150SS DMC 150SS Continuous Butterfly 150SS-W8 CDX plywood Versashield Solo As required per FBC Max.16-inch wide attachment with fasteners spaced 12 in.o.c. -114.25 180°seam Min.15/32 OPTIONAL 24 ga.DMC 150SS DMC 150SS Fixed Enhanced-90 150SS-W9 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide attachment -150 Min.90"seam with clips spaced 12 in.o.c. Min. 15/32 OPTIONAL 24 ga.DMC 150SS DMC 150SS Fixed Enhanced-180 150SS-W10 CDX plywood Versashield Solo As required per FBC Max.16-inch wide attachment -165 Min.180"seam with clips spaced 8 in.o.c. DRX15001.6 FL17678-R6 Page 3 of 8 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. CD t E K DREXEL METALS,INC. j't j� Metal Roofing TECHNICAL SERVICES, LLC APPENDIX B Approved Systems for DMC 150SS over Wood Deck(New or Existing) System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP No. (psf) 0.032'AI DMC 150SS Min..]5132._.._.—.-_OPTIONAL _ A ____ _ . As-required FBC DMC 150SS Enhanced(Al)attachment 150SS-W1 1 CDX plywood Versashield Solo s requper '- Max.16-inch wide 180°seam with clips spaced 8 in.o.c. -180 A roved S stems for DMC 175S over Steel Deck New or Existing) System Deck Fire Barrier Insulation Underlayment Roof Panel Panel Attachment MDP No. (psf) Min. 1 in.Approved _ Min.22 ga. 24 ga.DMC 175S DMC 175S#14 Standard attachment 175S-S1 As required polyisocyanurate. As required per FBC -60 Type B Steel Max. 18=inch wide with clips spaced 36 in.o.c. insulation board Min. 1 in.Approved Min.22 ga. 0.040"Al DMC 175S DMC 175S#14 Standard attachment 175S-S2 As required polyisocyanurate As required per FBC -88 Type B Steel insulation board Max.17.5-inch wide with clips spaced 18 in.o.c. Min.22 ga. Min.1 in.Approved 24 ga.DMC 175S DMC 175S#14 Standard attachment 175S-S3 As required polyisocyanu rate As required per FBC -105 Type B Steel insulation board Max.18-inch wide with clips spaced 6 in.o.c. Min. 1 in.Approved Min.22 ga. 0.040"Al DMC 175S DMC 175S#14 Standard attachment 175S-S4 Type B Steel As required polyisocyanurate As required per FBC Max.17.5-inch wide with clips spaced 12 in.o.c. -129.25 insulation board Approved Systems for DMC 175S over Wood Deck(New or Existing) System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP No. (psf) Min. 15/32 OPTIONAL 0.032"Al DMC 175S DMC 175S#10 Standard attachment 175S-Wl CDX plywood Versashield As required per FBC Max.18-inch wide with clips spaced 24 in.o.c. -52.5 Solo Min.15/32 OPTIONAL 0.032"AI DMC 1755 DMC 175S#10 Standard attachment 175S-W2 CDX plywood Versashield As required per FBC Max.18-inch wide with clips spaced 18 in.o.c. -59.4 Solo DRX15001.6 FL17678-R6 Page 4 of 8 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES, LLC APPENDIX B Approved Systems for DMC 175S over Wood Deck(New or Existing) System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP No. (psf) Min.15/32 OPTIONAL 0.032"AI DMC 175S DMC 175S#10 Standard attachment 175S-W3 CDX plywood Versashield As required per FBC Max.18-inch wide with clips spaced 12 in.o.c. -66.4 Solo Min.15/32 OPTIONAL 0.032"AI DMC 175S DMC 175S#10 Standard attachment 175S-W4 CDX plywood Versashield As required per FBC Max.18-inch wide with clips spaced 8 in.o.c. -71 Solo - Min olo . Min.15/32 OPTIONAL_ __ _. _ 0.032"AI DMC 175S DMC 175S#10 Enhanced attachment 175S-W5 CDX plywood Versashield Approved ASTM D 1970 undedayment Max.18-inch wide with clips spaced 12 in.o.c. -71 Solo ASTM D 226,Type II roofing felt attached per Min.15/32 _ 1518.2.1 with nails and tin caps per 1517.5 0.032"AI DMC 175S DMC 175S#10 Standard attachment 175S-W6 CDX plywood followed by Metshield High-Temp Max.18-inch wide with clips spaced 24 in.o.c. -74.75 Underlayment self-adFieied to felt Min.-15/32 OPTIONAL 0.032"AI DMC 175S DMC 175S#10 Standard attachment 175S-W7 CDX plywood Versashield As required per FBC Max. 14-inch wide with clips spaced 12 in.o.c. -82.5 Solo Min.15/32 OPTIONAL 24 ga.DMC 175S DMC 175S#10 Standard attachment 175S-W8 CDX plywood Versashield As required per FBC Max.18-inch wide with clips spaced 16 in.o.c. -84.25 Solo Min.19/32 24 ga.DMC 175S DMC 175S#10 Standard attachment 175S-W9 OPTIONAL CDX I Versashield As required per FBC -97.5 plywood Solo Max.16-inch wide with clips spaced 25 in.o.c. OPTIONAL Min.15/32 0.040"AI DMC 175S DMC 175S#10 Standard attachment 175S-W10 CDX plywood Versashield As required per FBC Solo Max.17.5-inch wide with clips spaced 18 in.o.c. -106.75 Min.15/32 OPTIONAL 24 ga.DMC 175S DMC 175S#10 Standard attachment 175S-W11 CDX plywood Versashield As required per FBC Max.18-inch wide with clips spaced 8 in.o.c. -121.75 Solo ASTM D 226,Type II roofing felt attached per 175S-W12 Min.15/32 - 1518.2.1 with nails and tin caps per 1517.5 0.032"AI DMC 175S DMC 175S#10 Standard attachment -131 CDX plywood followed by Metshield High-Temp Max.18-inch wide with clips spaced 6 in.o.c. Underlayment self-adhered to felt Min.19/32 OPTIONAL 24 ga.DMC 175S DMC 175S#10 Standard attachment 175S-W13 CDX plywood Versashield As required per FBC Max.16-inch wide with clips spaced 8 in.o.c. -135 Solo DRX15001.6 FL17678-R6 Page 5 of 8 This evaluation report.is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. GD E E K DREXEL METALS,INC. [� Metal Roofing TECHNICAL SERVICES, LLC APPENDIX B Approved Systems for DMC 200S over Steel Deck New or Existing) SyNttem ... -. •- Deck - Fire Barrier Insulation Underlayment Roof-Panel Panel Attachment PDO Min.1 in.Approved 24 ga.DMC 200S Min.22 ga. -- --�--.--- - - DMC 200S Butterfly(Steel)attachment 200S-S1 As required polyisocyanurate As required per FBC Max. 16-inch wide -88 Type B Steel insulation board 180°seam with clips spaced 24 in.o.c. 24 ga.DMC 200S 200S-S2 Min.22 ga. As required None As required per FBC Max. 16-inch wide DMC 200S Butterfly(Steel)attachment _g1.75 Type B Steel 180°seam with clips spaced 24 in.o.c. Min22 gaMin.1 in.Approved 24 ga.DMC 200S DMC 200S Continuous Butterfly(Steel) 2 . .00S-S3 As required polyisocyanurate As required per FBC Max. 16-inch wide -121.75 Type B Steel insulation board 180°seam attachment with clips spaced 12 in.o.c. Min.22 ga. 24 ga.DMC 200S DMC 200S Continuous Butterfly(Steel) 200S-S4 ' Type B Steel As required None As required per FBC Max.16-inch wide 180°seam attachment with clips spaced 12 in.o.c. -151.75 Approved Systems for DMC 200S over Wood'Deck(New or Existing) System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP No. (psf) 20OS-W1 Min.plywood 24 ga.DMC 200S OPTIONAL As required per FBC Max.16-inch wide DMC 200S Butterfly attachment -67.5 CDX pllywood Versashield Solo 180°seam with clips spaced 24 in.o.c. 200S-W2 Min.plywood 0.040"AI DMC 200S OPTIONAL As required per FBC Max.16-inch wide DMC 200S Butterfly attachment -75 CDX pllywood Versashield Solo 180°seam with clips spaced 24 in.o.c. 200S-W3 Min.plywood 0.040"Al DMC 200S OPTIONAL As required per FBC Max.16-inch wide DMC Fixed attachment -105 CDX pllywood Versashield Solo 180°seam with cllipsips spaced 16 in.o.c. 200S-W4 Min.plywood 0.040"AI DMC 200S OPTIONAL As required per FBC Max.16-inch wide DMC with Fixed Enhanced attachment -180 CDX pllywood Versashield Solo 180°seam with clips spaced 8 in.o.c. DRX15001.6 FL17678-R6 Page 6 of 8 This evaluation reportis provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. CREEKDREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES, LLC APPENDIX B Approved Systems for DMC 450 over Wood Deck(New or Existing) System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP No. - ...._....-.__.._. ..__ ._ .-. (psf) 450-W1 Min.19/32 OPTIONAL As required per FBC 24 ga.DMC 450 DMC 450 Standard attachment -30 CDX plywood Versashield Solo Max.16-inch wide with clips spaced 24 in.o.c. Min.15/32 OPTIONAL 0.032"AI DMC 450 DMC 450SS Standard attachment 450-W2 As required per FBC -45 COX plywood "Versa"shield Solo - Max.16-inch wide with clips spaced 16 in.o.c. 450-W3 Min.19/32 OPTIONAL As required per FBC 24 ga.DMC 450 DMC 450 Standard attachment -67.5 CDX plywood Versashield Solo Max.16-inch wide with clips spaced 15.5 in.o.c. Min.15/32 OPTIONAL 0.032"AI DMC 450 DMC 450SS Standard attachment 450-W4 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide with clips spaced 6 in.o.c. -75 450-W5 ,. Min.19/32 OPTIONAL As required per FBC 24 ga.DMC 450 DMC 450 Standard attachment _82 5 CDX plywood Versashield Solo Max. 16-inch wide with clips spaced 6 in.o.c. Approved Systems for DMC 5V over Wood Deck(New or Existing) System Deck Fire Barrier/ Underlayment Roof Panel Panel Attachment MDP No. Insulation (psf) OPTIONAL ASTM D 226,Type II roofing felt attached per 0.037'AI DMC 5V DMC 5V#10 Standard attachment Min.15/32 1518.2.1 with nails and tin caps per 1517.5 Min.21-inch to 5V-W1 Approved fire barrier with#10-14 HWH wood screws with -56 CDX plywood or insulation followed by Metshield High-Temp Max.24-inch sealing washers spaced 18 in.o.c. Underlayment self-adhered to felt coverage 26 ga.DMC 5V OPTIONAL DMC 5V Standard attachment Min.15/32 5V-W2 CDX plywood Approved fire barrier As required per FBC Max.24-inch Min.21-inch to with#9-15 HWH wood screws with -60 or insulation coverage sealing washers spaced 16 in.o.c. OPTIONAL ASTM D 226,Type II roofing felt attached per, 26 ga.DMC 5V DMC 5V#10 Standard attachment Min. 15/32 1518.2.1 with nails and tin caps per 1517.5 Min.21-inch to 5V-W3 CDX plywood Approved fire barrier followed by Metshield High-Temp Max.24-inch with HWH wood screws with -71 or insulation Underlayment self-adhered to felt coverage seallinging washers spaced 24 in.o.c. DRX15001.6 FL17678-R6 Page 7 of 8 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL,SERVICES, LLC APPENDIX B Approved Systems for DMC 5V over Wood Deck(New or Existing) System Deck Fire Barrier/ Underlayment Roof Panel Panel Attachment MDP No. Insulation (psf) 26 ga.DMC 5V OPTIONAL DMC 5V Pan Fastening attachment 5V-W4 .- Min.7/16 OSB .Approved fire barrier-------• As required per FBC Min.21-inch to with#10-14 HWH wood screws with -75 plywood or insulation Max.24 inch sealing washers spaced 16 in.o.c. coverage 26 ga.DMC 5V OPTIONAL DMC 5V Pan Fastening attachment plywood 5V-W5 Min.ywo od OSB Approved fire barrier As required per FBC Max.24 inch Min.21-inch h with#10-14 HWH wood screws with -112.5 orinsulation sealing washers spaced 8 in.o.c. coverage 26 ga.DMC 5V OPTIONAL DMC 5V Standard attachment Min.15/32 5V-W6 CDX plywood Approved fire barrier As required per FBC Max.24-inch Min.21-inch to with#9-15 HWH wood screws with -121.75 or insulation sealing washers spaced 8 in.o.c. coverage ASTM D 226,Type II roofing felt attached per -26 ga.DMC 5V or OPTIONAL 0.032"AI DMC 5V DMC 5V#10 Standard attachment Min.15/32 1518.2.1 with nails and tin caps per 1517.5 5V-W7 Approved fire barrier Min.21-inch to with#10-14 HWH wood screws with -206 CDX plywood or insulation followed by Metshield High-Temp Max.24-inch sealing washers spaced 6 in.o.c. Underlayment self-adhered to felt coverage Approved Systems for DMC Corrugated over Wood Deck(New or Existing) System Deck Fire Barrier/ Underlayment Roof Panel Panel Attachment MDP No. Insulation (psf) Min.15/32 OPTIONAL 0.032"Al DMC Corrugated DMC 5V Corrugated attachment COR-W1 CDX plywood Approved fire barrier As required per FBC Max.21-inch coverage with#10-15 HWH wood screws with dual threads -60 or insulation and sealing washer spaced 36 in.o.c. Min.15/32 . OPTIONAL 26 ga.DMC Corrugated DMC 5V Corrugated attachment COR-W2 CDX plywood Approved fire barrier As required per FBC Max.21-inch coverage with#10-15 HWH wood screws with dual threads -60 or insulation and sealing washer spaced 36 in.o.c. Min.15/32 OPTIONAL 0.032°AI DMC Corrugated DMC 5V Corrugated attachment COR-W3 CDX plywood Approved fire barrier As required per FBC Max.21-inch coverage with#10-15 HWH wood screws with dual threads -135 or insulation and sealing washer spaced 12 in.o.c. Min. 15/32OPTIONAL 26 ga.DMC Corrugated DMC 5V Corrugated attachment COR-W4 CDX plywood Approved fire barrier As required per FBC Max.21-inch coverage with#10-15 HWH wood screws with dual threads -150 or insulation and sealing washer spaced 12 in.o.c. DRX15001.6 FL17678-R6 Page 8 of 8 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES, LLC APPENDIX C DESIGN WIND LOADS The following tables provide design wind loads for components and cladding in accordance with Section 1609 of the FBC and ASCE 7-10 under the following provisions: 1. For Hip roofs between 2:12 and 5.6:12,Zone 3 shall be treated as Zone 2. 2. Wind speeds for risk category I, II, III,and IV buildings shall be as defined in Section 1609 of the FBC. 3. Exposure B,C,and D shall be as defined in section 1609 of the FBC. 4. Design wind load provided only for gable/hip roofs with roof slopes between 2:12 and 6.1:12 5. All calculations are based on an effective wind area of 10-ft2 or less. 6. Topographic factors such as escarpments or hills have been excluded from the analysis 7. Overhangs have been excluded from the analysis. 8. Wind directionality factor,Kd=0.85 9. Vuit is shown in the tables below. Design wind loads are calculated using Vasd=Vult110.6 per 1609.3.1. 10. Projects with mean roof heights greater than 60-ft shall be evaluated by a licensed design professional 11. Zones 1,2,and 3 shall be defined as shown below. Dimension"a"shall be 10%of the least horizontal dimension or(0.4 x Mean Roof Height),whichever is smaller,but not less than either 4%of the least horizontal dimension or 3ft Gable- Hip N a _ 3 2 3 3 2 3 a \ 3 2 3 a 2 1 2 2 1 2 2 1 2 2 1 2 _ 1 3 2 3 131 2 1 31 a 3 2 3 a lal lalal lal lal lal DRX15001.6 FL17678-R6 Page 1 of 4 This evaluation report.is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. GD E E K DREXEL METALS,INC. jZ Metal Roofing TECHNICAL SERVICES,LLC APPENDIX C Gable/Hip Roofs in Exposure B Roof slope between 2:12 and 6.1:12 Building - - Mean -- Basic Wind S eed m h Type Zone HeR hof tt 120 130 140 150 160 170 180 190 200 20 -14.2 -16.7 -19.3 -22.2 -25.3 -28.5 -32.0 -35.6 -39.5 25 -14.2 -16.7 -19.3 -22.2 -25.3 28.5 -32.0 -35.6 -39.5 30 -14.2 -16.7 -19.3 -22.2 -25.3 -28.5 -32.0 -35.6 -39.5 _ ..............._ . ._ 40_.. _.__.._1.5.4._.._.... -18.1 ___21..0 _ -24.1 -27.4 -31.0 -34.7 1 -38.7 -42.9 50 -16.5 -19.3 -22.4 -25.7 -29.2 -33.0 -37.0 -41.2 -45.7 60 -17.3 -20.3 -23.5 -27.0 -30.7. - -34.6 -38.8 -43.3 -47.9 20 -24.7 -29.0 -33.7 -38.7 -44.0 -49.7 -55.7 -62.0 -68.7 25 -24.7 -29.0 -33.7 -38.7 -44.0 -49.7 -55.7 -62.0 -68.7 Enclosed 2 30 -24.7 -29.0 -33.7 -38.7 -44.0 -49.7 -55.7 -62.0 -68.7 40 _------26.9......,...........31.5 -36.6 -42.0 -47.8_._ .._. .-53.9 -60.4 -67.3 -74.6 50 -28.6 -33.6 -39.0 -44.7 -50.9 -57.5 -64.4 -71.8 -79.5 60 -30.0 -35.3 -40.9 -46.9 -53.4 -60.3 -67.6 -75.3 -83.5 20 -36.6 -42.9 . -49.8 -57.2 -65.0 -73.4 -82.3 -91.7 -101.6 25 -36.6 -42.9 -49.8 . -57:2. -65.0 -73.4 -82.3 -91.7 -101.6 3 30 -36.6 -42.9 -49.8 -57.2 -65.0 -73.4 -82.3 -91.7 -101.6 40 -39.7 -46.6 -54.1 -62.1 -70.6 -79.7 -89.4 -99.6 -110.3 50 -42.3 -49.7 -57.6 -66.2 -75.3 -85.0 -95.3 -106.1 -117.6 60 -44.4 -52.1 -60.5 -69.4 -79.0 -89.2 -100.0 -111.4 -123.4 20 -19.1 -22.4 -26.0 -29.8 -33.9 -38.3 -42.9 -47.8 -53.0 25 -19.1 -22.4 -26.0 -29.8 -33.9 -38.3 -42.9 -47.8 -53.0 1 30 -19.1 -22.4 -26.0 -29.8 -33.9 -38.3 -42.9 -47.8 -53.0 40 -20.7 -24.3 -28.2 -32.4 -36.8 -41.6 -46.6 -51.9 -57.6 50 -22.1 -25.9 -30.1 -34.5 -39.3 -44.3 -49.7 -55.4 -61.3 60 -23.2 -27.2 -31.5 -36.2 -41.2 -46.5 -52.1 -58.1 -64.4 20 -29.6 -34.8 -40.3 -46.3 -52.6 -59.4 -66.6 -74.2 -82.3 25 -29.6 -34.8 -40.3 -46.3 -52.6 -59.4 -66.6 -74.2 -82.3 Partially 30 -29.6 -34.8 -40.3 -46.3 -52.6 -59.4 -66.6 -74.2 -82.3 Enclosed 2 40 -32.2 -37.7 -43.8 -50.2 -57.2 -64.5 -72.3 -80.6 -89.3 50 -34.3 -40.2 -46.6 -53.5 -60.9 -68.8 -77.1 -85.9 -95.2 60 -36.0 -42.2 -48.9 -56.2 -63.9 -72.2 -80.9 -90.1 -99.9 20 -41.5 -48.7 -56.4 -64.8 -73.7 -83.2 -93.3 -103.9 -115.2 25 -41.5 -48.7 -56.4 -64.8 -73.7 -83.2 -93.3 -103.9 -115.2 3 30 -41.5 48.7 -56.4 -64.8 -73.7 -83.2 -93.3 -103.9 -115.2 40 -45.0 -52.8 -61.3 -70.3 -80.0 -90.3 -101.3 -112.8 -125.0 50 -48.0 -56.3 -65.3 -75.0 -85.3 -96.3 -107.9 -120.3 -133.3 60 -50.3 -59.1 -68.5 -78.7 -89.5 -101.0 -113.3 -126.2 -139.8 DRX15001.6 FL17678-R6 - Page 2 of 4 This evaluation report is.provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. G REEK DREXEL METALS,INC. IMMetal Roofing TECHNICAL SERVICES, LLC APPENDIX C Gable/Hip Roofs in Exposure C Roof slope between 2:12 and 6.1:12 Building Mean _. -. _._._...._.. Basic Wind Speed m h Type Zone He ofttht 120 130 140 150 160 170 180 190 200 20 -18.3 -21.4 -24.9 -28.6 -32.5 -36.7 -41.1 -45.8 -50.8 25 -19.1 -22.4 -26.0 -29.8 -33.9 -38.3 -42.9 -47.9 -53.0 1 30 -19.9 -23.4 -27.1 -31.1 -35.4 -39.9 -44.8 -49.9 -55.3 40 _-._21.1 __._.. _..__724.8 -28.7 -33.0 .. -37.5 -42.4 -47.5 1 -52.9 -58.7 50 -22.1 -26.0 -30.1 -34.6 -39.4 -44.4 -49.8 -55.5 -61.5 60 -22.9 -26.9 -31.2 -35.9 -40.8 -46.1 -51.6 -57.5 -63.7 20 -31.8 -37.3 -43.3 -49.7 -56.6 -63.8 -71.6 -79.8 -88.4 25 -33.2 -39.0 -45.2 -51.9 -59.1 -66.7 -74.8 -83.3 -92.3 Enclosed 2 30 -34.6 -40.7 -47.2 -54.1 -61.6 -69.5 -77.9 -86.8 -96.2 40 - -36.8 -43.1.. -50.0 -57.4 - -65.4 -73.8 -82.7 -92.2 -102.1 50 -38.5 -45.2 -52.4 -60.2 -68.5 -77.3 -86.7 -96.6 -107.0 60 -39.9 -46.9 -54.4 -62.4 -71.0 -80.2 -89.9 -100.1 -111.0 20 -47.0 -55.2 -64.0 -73.5. . -83.6 -94.4 -105.8 -117.9 -130.7 .25 -49.1 -57.7 -66.9 -76.8 787.3 -98.6 -110.5 -123.2 -136.5 3 30 -51.2 -60.1 -69.7 -80.0 -91.1 -102.8 -115.3 -128.4 -142.3 40 -54.4 -63.8 -74.0 -84.9 -96.6 -109.1 -122.3 -136.3 -151.0 50 -57.0 -66.9 -77.5 -89.0 -101.3 -114.3 -128.2 -142.8 -158.3 60 -59.1 -69.3 -80.4 -92.3 -105.0 -118.5 -132.9 -148.1 -164.1 20 -24.5 -28.8 -33.4 -38.3 -43.6 -49.2 -55.2 -61.5 -68.2 25 -25.6 -30.1 -34.9 -40.0 -45.6 -51.4 -57.7 -64.2 -71.2 1 30 -26.7 -31.4 -36.4 -41.7 -47.5 -53.6 -60.1 -67.0 -74.2 40 -28.4 -33.3 -38.6 -44.3 -50.4 -56.9 -63.8 -71.1 -78.8 50 -29.7 -34.9 -40.5 46.4 -52.8 -59.6 -66.9 -74.5 -82.5 60 -30.8 -36.2 -41.9 -48.1 -54.8 -61.8 -69.3 -77.2 -85.6 20 -38.1 -44.7 -51.8 -59.5 -67.7 -76.4 -85.7 -95.4 -105.8 25 -39.8 -46.7 -54.1 -62.1 -70.7 -79.8 -89.5 -99.7 -110.5 Partially 30 -41.5 -48.7 -56.4 -64.8 -73.7 -83.2 -93.3 -103.9 -115.2 Enclosed 2 40 -44.0 -51.6 -59.9 -68.7 -78.2 -88.3 -99.0 -110.3 -122.2 50 -46.1 -54.1 -62.8 -72.0 -82.0 -92.5 -103.8 -115.6 -128.1 60 -47.8 -56.1 -65.1 -74.7 -85.0 -95.9 -107.6 -119.8 -132.8 20 -53.3 -62.6 -72.6 -83.3 -94.8 -107.0 -119.9 -133.6 -148.1 25 -55.7 -65.3 -75.8 -87.0 -99.0 -111.7 -125.3 -139.6 -154.6 3 30 -58.0 -68.1 -79.0 -90.7 -103.2 -116.5 -130.6 -145.5 -161.2 40 -61.6 -72.3 -83.8 -96.2 -109.5 -123.6 -138.6 -154.4 -171.1 50 -64.6 -75.8 -87.9 -100.9 -114.8 -129.6 -145.2 -161.8 -179.3 60 -66.9 -78.5 -91.1 -104.6 -119.0 -134.3 -150.6 -167.8 -185.9 DRX15001.6 FL17678-R6 Page 3 of 4 This evaluation report.is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. a' I CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES,LLC APPENDIX C Gable/Hip Roofs in Exposure D Roof slope between 2:12 and 6.1:12 Building - - Mean Basic Wind Speed m h Type Zone HeR hof tt 120 130 140 150 160 170 180 190 200 20 -21.9 -25.7 -29.9 -34.3 -39.0 -44.0 -49.3 -55.0 -60.9 25 -22.7 -26.7 -31.0 -35.5 -40.4 -45.6 -51.2 -57.0 -63.2 1 30 -23.6 -27.6 -32.1 -36.8 -41.9 -47.3 -53.0 -59.1 -65.4 _ ................__. 40 --.724.8-- .-29.1 ...33.7 -38.7 .. -44.0 -49.7 -55.7 -62.1 -68.8 50 -25.8 -30.3 -35.1 -40.3 .. -45.9 -51.8 -58.0 -64.6 -71.6 60 -26.6 -31.2 -36.2 -41.6 -47.3 -53.4 -59.9 -66.7 -73.9 20 -38.2 44.8 -52.0 -59.7 -67.9 -76.6 -85.9 -95.7 -106.0 25 -39.6 46.5 -53.9 -61.9 -70.4 -79.5 -89.1 -99.2 -110.0 Enclosed 2 30 -41.0 48.1 -55.8 -64.1 -72.9 -82.3 -92.3 -102.8 -113.9 .40 ---743.1-. -. -50.6 -58.7 -67.4... -76.7_ -86.5 -97.0 -108.1 -119.8 50 -44.9 -52.7 -61.1 -70.1 -79.8 -90.1 -101.0 -112.5 -124.7 60 -46.3 -54.3 -63.0 -72.4 -82.3 -92.9 -104.2 -116.1 -128.6 20 -56.5 -66.3 776.8. -88.2. -100.4 -113.3 -127.0 -141.5 -156.8 25 -58.5 -68.7 -79.7 -91.5 -104.1. -117.5 -131.7 -146.8 -162.6 8 30 -60.6 -71.2 -82.5 -94.7 -107.8 -121.7 -136.4 -152.0 -168.4 40 -63.8 -74.8 -86.8 -99.6 -113.4 -128.0 -143.5 -159.9 -177.1 50 -66.4 -77.9 -90.4 •-103.7 -118.0 -133.2 -149.4 -166.4 -184.4 60 -68.5 -80.4 -93.2 -107.0 -121.7 -137.4 -154.1 -171.7 -190.2 20 -29.4 -34.6 -40.1 -46.0 -52.3 -59.1 -66.3 -73.8 -81.8 25 -30.5 -35.8 -41.6 -47.7 -54.3 -61.3 -68.7 -76.5 -84.8 1 30 -31.6 -37.1 -43.0 -49.4 -56.2 -63.5 -71.2 -79.3 -87.8 40 -33.3 -39.0 -45.3 -52.0 -59.1 -66.8 -74.8 -83.4 -92.4 50 -34.6 -40.6 -47.1 -54.1 -61.6 -69.5 -77.9 -86.8 -96.2 60 -35.7 41.9 -48.6 -55.8 -63.5 -71.7 -80.4 -89.5 -99.2 20 -45.7 -53.6 -62.2 -71.4 -81.2 -91.7 -102.8 -114.5 -126.9 25 -47.4 -55.6 -64.5 -74.0 -84.2 -95.1 -106.6 -118.8 -131.6 Partially 30 -49.1 -57.6 -66.8 -76.7 -87.2 -98.5 -110.4 -123.0 -136.3 Enclosed 2 40 -51.6 -60.6 -70.2 -80.6 -91.8 -103.6 -116.1 -129.4 -143.4 50 -53.7 -63.1 -73.1 -83.9 -95.5 -107.8 -120.9 -134.7 -149.2 60 -55.4 -65.0 -75.4 -86.6 -98.5 -111.2 -124.7 -138.9 -153.9 20 -64.0 -75.1 -87.1 -99.9 -113.7 -128.4 -143.9 -160.3 -177.7 25 -66.3 -77.8 -90.3 -103.6 -117.9 -133.1 -149.2 -166.3 -184.3 3 30 -68.7 -80.6 -93.5 -107.3 -122.1 -137.9 -154.6 -172.2 -190.8 40 -72.3 -84.8 -98.3 -112.9 -128.5 -145.0 -162.6 -181.1 -200.7 50 -75.2 -88.3 -102.4 -117.5 -133.7 -151.0 -169.2 -188.6 -208.9 60 -77.6 -91.1 -105.6 -121.2 -137.9 -155.7 -174.6 -194.5 -215.5 DRX15001.6 FL17678-R6 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein.