HomeMy WebLinkAboutProduct approvals, metal8/7/2020 Florida Building Code Online
G:19W_ ..
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCiS Site Map Links Search
d
Product Approval
op-
USER:�Public User
Product Approval Menu > ProduCL or Application Search > Application List
Search Criteria
Refine Search
Code Version 2017 FL#
17022.1
Application Type ALL Product Manufacturer
ALL
Category ALL Subcategory
ALL
Application Status ALL Compliance Method
ALL
Quality Assurance Entity ALL Quality Assurance Entity Contract Expired
ALL
Product Model, Number or Name ALL Product Description
ALL
Approved for use in HVHZ ALL Approved for use outside HVHZ
ALL
Impact Resistant ALL Design Pressure
ALL
Other ALL
Search Results - Applications
FL# Type Manufacturer
Validated
Status
gy
FL17022- Revision Extreme Metal Fabricators, LLC
Zachary R.
Approved
R7 FL#: FL17022.1
Priest, P.E.
History. Model: 1 - "5V Crimp" (R6)
(813) 480-
Description: 26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel
3421
mechanically attached to 15/32" plywood or Wood Deck with fasteners
Category: Roofing
Subcategory: Metal Roofing
"Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail, if you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275(i ).
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The eria:ls
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts-
1 ._s:-.
Greet Card
Safe
https://ww�v.floridabuilding.org/pr/pr_app_lst.aspx 1/1
2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
Compliant with Florida Building Code 2017 (61h ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2
Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood
Deck w/ min. 0.42 specific gravity with screws, 24" Coverage
Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec. 1507.4.3
Fastener 1 (Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate
3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet
requirements)
Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to
penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec. 1507.
See Fastener attachment specifications above
Install Details: Table A Allowable Loads
METHOD 1
METHOD 2
METHOD 3
1 METHOD 4�
DESIGN PRESSURE*
-86 PSF
-93.5 PSF
-101 PSF
-228 PSF i
ROW SPACING
16" o.c.
16" o.c.
8" O.C.
6" o.c.
FASTENER SPACING (ALONG Panel width)
( 12" O.C.
12" O.C.
12" O.C.
12, O.C.
FASTENER SIZE
( #9
#10
#10
j #10
Reference Data: ARCHITECTURAL TESTING, INC. TST 1D#: 1527
UL 580-06 & 1897-041 Test Report C05893.01-450-18 05/02/14
Test Report F3366.01-450-18 12/18/15
TAS 125-03 Test Report D05893.02-450-18 07/22/14
*EQUIVALENCY-UL 1897-04 is equivalent to test standard UL 1897-12 *Design
pressure margin of safety 2:1
..,etitfrftrw..
_-_
Locke Bowden, P.E. does not have, not will acquire a financial int n 81 cq 8� facturing or distributing products
under this evaluation. " d
Locke Bowden, P.E. is not owned, operated, or controlled by at y coaiparN;jrr4iWfa4turer, or Qistributing products under this
report.
t.
FL17O22.1 5V Crimp (26GA Steel), 24" Wide Roof Panel - Details
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed.
2. Minimum slope to be compliant with Florida Building Code 2017 61h ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 61h ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for
Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
Panel
Overlap
75i32" or greater Plywood. or
Wood plank
12"
t4 —
Panel Profile
Nominal12" _ Nominal12"
O.C. O.C.
Fasten
#9 x 1-1/2" Min. or #10 x 1-1/2" Min. per
Table "A" Hex Washer Head Screw
Spaced 12" o.c. across the Panel Width
Refer to Table "A" for Spacing Along Panel
Length
Deck-15/32" or greater
Plywood, or
-Wood plank