HomeMy WebLinkAboutConstruction PlansDESIGN CRITERIA: APPLICABLE CODES REGULATIONS & STANDARDS 1. THE 2017 FLORIDA BUILDING CODE, SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CH. 23 WOOD. 2. AA ASM 35 & SPECIFICATIONS FOR ALUMINUM STRUCTURES, PART I -A OF THE ALUMINUM DESIGN MANUEL PREPARED BY THE ALUMINUM ASSOCIATION, INC. WASHINGTON D.C. 2005 ED. 3. ASCE 7-10 & SET 4. NDS NATIONAL DESIGN SPECIFICATION FOR WOOD. 5. AC1318 CONCRETE REFRENCE MANUAL. WIND LOADS 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 1604.5: RISK CATEGORY 1. 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED, PARAGRAPH 1609.3.1 & TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEED: 150 MPH EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: C 3. WIND LOADS PER FBC TABLE 2002.4 (MWFRS) - VULT = 150 MPH & EXPOSURE = C FOR 20 X 20 X 0.013" MESH SCREEN HORIZONTAL PRESSURES ON WINDWARD SURFACES = 43 PSF HORIZONTAL PRESSURES ON LEEWARD SURFACES = 34 PSF VERTICAL PRESSURES ON SCREEN SURFACES = 12 PSF VERTICAL PRESSURES ON SOLID SURFACES = 36 PSF FOR 18 X 14 X 0.013" MESH SCREEN, APPLIED FACTOR = .88 FOR ALLOWABLE STRESS DESIGN, APPLIED FACTOR = .6 FOUNDATION DESIGN FOOTING SIZE EXISTING CONCRETE SLAB. NO ADDITIONAL FOOTING OR FOUNDATION SYSTEM IS REQUIRED BY THE PROPOSED CONSTRUCTION IF A MINIMUM 4" CONCRETE SLAB IS PROVIDED IN SOUND CONDITION, FREE FROM STRUCTURAL CRACKING, SPALLING & OTHER DETERIORATION. EXISTING FOUNDATION/FOOTING UNDER CONCRETE SLAB MINIMUM 8"x8" W/ (1) #5 BAR TO BE VERIFIED BY CONTRACTOR. SEE TYPICAL FOOTING DETAILS FOR NEW FOOTING DESIGN MINIMUM REQUIREMENTS. SPECIFICATIONS THE FOLLOWING SPECIFICATIONS ARE APPLICABLE TO THIS PROJECT: I. WHERE CONCRETE SPECIFICATIONS ARE REQUIRED, WHETHER IN THE SCREEN ENCLOSURE SCOPE OF NOT, BY ONE OR MORE REGULATORY AGENCY, THE FOLLOWING SPECIFICATIONS ARE APPLICABLE: - a. CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING COMPONENTS: i. PORTLAND CEMENT TYPE 1 -ASTM C 150 ii AGGREGATES - LARGE AGGREGATE 3/4 MAX. - ASTM C 33 iii. AIR ENTRAINING +/- 1 %- ASTM C 260 iv. WATER REDUCING AGENT-ASTM C 494 v. CLEAN PORTABLE WATER vi. OTHER ADMIXTURES NOT PERMITTED b. METAL ACCESSORIES SHALL CONFORM TO: L REINFORCING BARS - ASTM A615, GRADE 60 ii. WELDED WIRE FABRIC -ASTM A185 c. CONCRETE SLUMP AT DISCHARGE CHUTE NOT LESS THAN 3" OR MORE THAN 5". WATER ADDED AFTER BATCHING IS NOT PERMITTED. d. PREPARE & PLACE CONCRETE PER AMERICAN CONCRETE INSTITUTE MANUAL OF STANDARD PRACTICE, PART 1, 2, & 3 INCLUDING HOT WHEATHER RECOMMENDATIONS. e. MOIST CURE OR POLYETHYLENE CURING PERMITTED. f. PRIOR TO PLACING CONCRETE, TREAT THE ENTIRE SUBSURFACE ARE FOR TERMITES IN COMPLIANCE WITH THE FBC. g. CONCRETE SHALL BE PLACED OVER A POLYETHYLENE VAPOR BARRIER. 2. WHEN PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT 3. WHEN APPLICABLE FOR NEW SLAB ADDITION TO ADJACENT DRILL & EPDXY #5 X W REBAR INTO EX. FOUNDATION WITH I" MIN. HOLE, EMBED 4" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) 48" O.C. TYP. ALL LOCATIONS 4. WHEN APPLICABLE FOR NEW FOOTER TO EXISTING, DRILL & EPDXY NEW STEEL INTO EX. FOUNDATION WITH 1" MIN. HOLE, EMBED 6" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) TYP. ALL LOCATIONS 5. MINIMUM CONCRETE STRENGTH 3000 PSI UNLESS OTHERWISE NOTED. ALUMINUM SPECIFICATIONS 1. ALUMINUM EXTRUSIONS SHALL BE 6005 T5 ALLOY UNLESS OTHERWISE NOTED. 2. ALL SELF MATING BEAM SECTIONS ARE TO BE STITCHED WITH #12 SCREWS 6" FROM ENDS & 24" CENTER TO CENTER. 3. ROOF BRACING SHALL BE A MINIMUM 2X2"X.050". 4. THE MINIMUM NORMAL THICKNESS OF PROTECTOR PANELS (KICKPLATES) SHALL BE AN INDUSTRY STANDARD OF 0.024 INCHES. 5. VINYL AND ACRYLIC PANELS SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH PER FBC. 6. SCREEN MATERIAL SHALL BE 18/14 SCREEN UNLESS APPROVED BY FLORIDA ENGINEERING LLC. 5. 1"X2" & 1"X3" NON STRUCTURAL MEMBERS MAY BE USED INTERCHANGEABLY. FASTENER SPECIFICATIONS 1. FASTENERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. (CONCRETE ANCHORS ARE TO BE TAPCONS OR BETTER, INSTALLED TO MFG. SPECIFICATIONS) 2. IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SCREENS, FASTENERS AND SCREENS TO MANUFACTURING SPECIFICATIONS. 3. WHERE WOOD DECK IS PRESENT USE 1/4" X 3-1 /2" GALV. LAG SCREWS IN LIEU OF MASONRY ANCHORS. UNLESS OTHERWISE SPECIFIED. 4. 1"X2" NON STRUCTURAL MEMBERS ATTACHED TO HOST A. FOR MASONRY/CONCRETE APPLICATION USE GALVANIZED 1/4" X 2-3/4" TAPCONS OR EQUAL AT 24" O.C. AND 6" FROM ENDS B. FOR WOOD APPLICATION USE #14 X 2-3/4" WOOD SCREW AT 24" O.C. AND 6" FROM ENDS. C. FOR ALUMINUM APPLICATION USE # 10 X 1-1/2" SMS OR TEK SCREW AT 24" O.C. AND 6" FROM ENDS D. WHERE 172" INSTALLED THROUGHOUT AN "OPEN VIEW' SPACING SHALL BE REDUCED TO 18" O.C. AND 6" FROM ENDS MASONRY SPECIFICATIONS 1. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2. ALL MORTAR SHALL BE TYPE M OR S. 3. ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4. PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5'-0" IN HEIGHT. MISCELLANEOUS 1. SCREENED ENCLOSURES CONTAINING SWIMMING POOLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC R4501.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. 2. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPERATE 4TH WALL SUPPORT SYSTEM IS SO TO BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 3. DOOR LOCATION MAY BE RELOCATED BY CONTRACTOR IN THE FIELD. 4. WHERE PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT. 5. INTEGRITY OF EXISTING/ HOST STRUCTURE SHALL NOT BE COMPROMISED WITH THE ATTACHMENT OF THE PROPOSED STRUCTURE. 6. ALL 2X4 & GREATER ARE TO BE 2 x 4 SMB: ZX4'x0.044"x0.100" UNLESS OTHERWISE INDICATED. RESPONSIBILITIES 1. ALL SITE WORK SHALL BE PERFORMED BY A LISCENED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDANANCES, AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. 2. FOR FASTENERS WHICH ARE NOT VISIBLE AFTER INSTALLATION, THE CONTRACTOR SHALL VERIFY AND ENSURE INSTALLATION HAS BEEN ACCOMPLISHED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE WITH THE ATTACHED DETAILS. 3. FOR "PICTURE WINDOW" MODIFICATION TO EXISTING SCREEN ENCLOSURES, ALL OTHER "EXISTING SCREEN ENCLOSURE' FEATURES ARE TO MEET THE TYPICAL DETAILS AS PROVIDED IN THESE DETAILS. CONTRACTOR IS TO VERIFY & ASSURE EXISTING SCREEN ENCLOSURE IS STRUCTUALLY SOUND. ALUMINUM MEMBERS DIMENSIONS HOLLOW SECTIONS 2 x 2: 2"x2'k0.044" 2 x 3: 2'x3'x0.050" 2 x 4: 2'x4"x0.050" 2 x 5: 2'x5'x0.050" OPEN BACK SECTIONS 1 x2: 1"x2'x0.044" 1 x3: 1'x3'x0.045" SNAP SECTIONS 2 x 2 SNAP: 2'x2'x0.045" 2 x 3 SNAP: Z'X3x0.050" 2 x 4 SNAP: 2'x4"x0.045" SELF MATING (SMB) 2 x 4 SMB: 2'x4'x0.044'x0.100" 2 x 5 SMB: 2'x5"x0.050"x0.100" 2 x 6 SMB: 2'x6"x0.0506.120" 2 x 7 SMB: 2WN0.057"x0.120" 2 x 8 SMB: Zx8'x0.072'k0. 124' 2 x 9 SMB: 2'x9"x0.082'x0. 124' 2 x 10 SMB: 2'x1 Y'x0.09Z'x0.398" DETAIL A FIL C®P� rVIAE D F R GO®E COMPLIANCE ST. L CIE COUNTY s®cc�rp ;O h o =Z: - •2 - W O W •C2 F d c m o N O N =C7: m 00 pp J Ci o MONO DECK (DSODDED GRADE SLAB OPTION -�., i.� 11)#5 BAR 8" CONTINUOUS FOOTING NOTES 1. PROVIDE 1-1 /Z COVERAGE TOP, SIDES, BOTFOM AND I"BETWEEN ADJACENT REBAR LAPS. 2. PROVIDE MIN. 3" COVERAGE OF REBAR FOR ALL CONCRETE IN CONTACT WITH THE EARTH. 3. FOOTING CONCRETE SHALL BE MIN. 3000 PSI AT 28 DAYS 4. FOOTING REINFORCEMENT SHALL BE MIN. GRADE 40 S. PROVIDE POSITIVE DRAINAGE AWAY FROM STRUCTURE TO CITY / CO. REQUIREMENTS 6. PROVIDE 2500 PSF BEARING (TYPICAL) UNDER FOUNDATION ]. SEE GENERAL NOTE FOR TYING INTO EXISTING FOUNDATIONS 8. SEE GENERAL NOTES FOR ADDITIONAL CONCRETE INFORMATION & SPECS. DETAIL "J" FOOTINGS SCALE: NTS 4 8" x 8" FOC N iX2 2X2 DJ 2X2 DJ 0 2XSSMB HOST 18" O/H STRUC. GUTTER 2X3X.050 DIAG. BRACE TYP. ® = 3X3X.125 THESE PLANS WERE PREPARED BASED ON THE PREMISE THAT THE EXISTING STRUCTURE WAS DESIGNED BY A PROPERLY LICENSED PROFESSIONAL ENGINEER OF THE STATE OF FLORI DA, WAS PERMITTED BY THE APPROPRIATE PERMITTING AGENCY, WAS CONSTRUCTED BY A FLORI DA LICENSED CONTRACTOR AT THE TIME OF CONSTRUCTION, HAS NOT BEEN SU BI ECT TO DAMAGE BY A MAJOR EVENT, AND HAS BEEN CERTIFIED BY THE CONTRACTOR THAT THE EXISTING STRUCTURE CURRENTLY SHOWS NO DEVIATIONS OR DEFECTS FROM THE STATE OF THE STRUCTURE AS PERMITTED BY THE FINAL INSPECTION OF THE PERMITTING AGENCY. ALSO, THE OWNER AND ALL PARTIES CONCERNED WILL INDEMNIFY FLORIDA ENGINEERING LLC FROM ANY DAMAGES OR CHANGES TO THE EXISTING STRUCTURE AS A RESULT OF ANY MODIFICATION OR FOR ANY OTHER REASON. 2X2 TYP. EXISTING APPROVED ELITE ROOF W/ E-GUTTER 1" 1 2X9SMB C.B. F —8'-0"- 3X3X.125 2X5SMB N X O m m m 2 X X O cX-I N + i N to N N N X R O X to UJ m f` r . n + r N X i N/ X N N N N N N N x x 1 2X5SMB 2X2 TYP. i 2X5SMB 1 F, 1X2 W-0 r i ___--------- -I--_-'_ - - _T 1X2 + 2X2 \ m n'1 ` m m m 2 m m CID N `gym X X X m X N X x N N 0 N N N 2X2 TYP. m 1X2 TYP. I 9"+6'-5 I 1 I t6'-5 I 6'-5 i ---4-6 5 1 0 i� 1X2 REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY Roce . Q�.•'� CA c') C) O a o =�.0 m Q tiZ_ N F O Uj '"Noll IIlH\\ 5" OR 7"x6" WIDTHx0.250" EXTRUDED GUTTER BRACKET @ EA. BEAM W/ (4) #12x34' S.M.S. INTO GUTTER LIP 1"x2"x0.045" OPEN BACK W/ (2) #12x2" INTO GUTTER & (1) #12x 2" @ 24" O.C. O BEAM 1 O O O ANGLE W/ (2) #14x3/4" S.M.S. INTO BEAM ON EA SIDE (4) INTO GUTTER OPTIONAL: 2"x2"0.062" RECEIVING CHANNEL W/(2) #10x3/4" EA SIDE TO COVER EXPOSED BEAM NOTE: 2x4 SMB BEAM ONLY REQUIRES 4" LMDTH GLTfTER BRACKET W/(2) 3/8" LAGS (4) 3f8" LAG SCREWS @ 1-1/2" SPACING @ EA GUTTER BRACKET & (1) @ 120.C. MAX -MIN EMBEDMENT SHALL BE 2" THE HOST STRUCTURE SHALL HAVE AT LEAST A 2"x4" FASCIA AND ROOF TRUSS SYSTEM. CONTRACTOR SHALL VERIFY THIS AND IF SMALLER CONTRACTOR SHALL BRING STRUCTURE UP TO A 2"x4" FASCIA AND ENSURE LESS THAN A 2'-0" OVERHANG GUTTER BRACKET & BEAM ATTACHMENT DETAIL SCALE:NTS NOTES: 1. HINGES SHALL BE ATTACHED TO STRUCTURE W/(4) #IOx5/8" S.M.S. MINIMUM. 2. DOOR SHALL BE ATTACHED TO ENCLOSURE W/ (2) HINGES MINIMUM. 3. HINGS SHALL BE ATTACHED TO DOOR WITH (4) #10x5/8' S.M.S. FASTEN A 1"x2x0.044" TO UPRIGHT W/ #120" S.M.S. @ 12" O.C. AND WITHIN 3' FROM END OF THE UPRIGHT. TYPICAL SCREEN DOOR CONNECTION DETAIL SCALE:NTS BEAM SCREWS 2"x4"SMB 6 2"x5"SMB 6 2"x6'SMS 8 2"x7"SMB 8 2"x8"SMB 10 2"x9"SMB 10 2"x10"SMB 12 Tx PURUNS(SEE A-1 PLATE FOR SIZE) ATTACHED TO 914 SMS BEAM W/ MIN. (4) #10x1 1/2" SMS N O O O O \ n ` N9 o %` am O O O 1\ yN1� o m�a \11 OO O O O O 11` _A N %0 \ N`1g�e ^ 53p1Aj,1P El (GEE. "B" "N" "Si. "S2" "S3' "54" 12 4 314" 1 1/2" 16" 3.75" 12 4 314" 1 1/2" 16" 4.75" E 16 5 1" 11/2" 19" 575" 20 6 1"1 1/2" 22' 6.75" 24 7 1" 1 m" 23" 7.75" 2X9 24 7 1" 13'8" 23" 8.75" 2X10 28 8 T' 1 1/4" 24" 9.75" GUSSET NOTES: 1. "N" NUMBER OF SCREWS IN ANY DIRECTION. 2. TOTAL NUMBER OF SCREWS PER JOINT EQUALS 4 TIMES "B". 3. PLATE WIDTH SHALL BE DETERMINED FROM ANGLE OF BEAM AND MIN SPACE REQUIRED. 4. GUSSET PLATES MAYBE INTERNAL OR EXTERNAL. 5. INTERNAL SCREWS FOR PURLIN CONNECTION MAY BE INCLUDED IN TOTAL NUMBER OF SCREWS. 6. GABLE SPLICE WILL HAVE THE SAME PATTERN. BEAM SPLICE GUSSET DETAIL TYPICAL SCALE:NTS MAINTAIN MIN, OF 5/8" SEPERATION FROM EDGE OF BEAM SMS O.C. FOR SLOPED BEAMS MAINTAIN ALL SCREW SPACING FROM EDGE OF BEAM 2"x2" EAVE RAIL SECTION (UNLESS OTHERWISE SHOWN ON S-2) ATTACHED TO BEAM W/ (4)10x2" SMS INTO SCREW BOSS 1"x2" OPEN BACK EAVE RAILATTACHEDTO UPRIGHT W/ (2) #10x1 1/2" SMS INTO SCREW BOSS #1&1 1/2" SMS 24" C/C #14x3/4" SCREWS (SEE TABLE ABOVE) SELF -MATING BEAM SHALL BE NOTCHED FOR UPRIGHT O O 0 oil II 0 01! UPRIGHT UPRIGHT TO BEAM CONNECTION -ALL WIND ZONES SCALE:NTS - \\\01\1 0II II III,,/J/�/�y" N Q N =Z;h O 0 O =�.Z o W i .••' �� \ W /9"/NHIHPI\O\\\ U HT WEB LAPPED OVER PURLIN #12x3W SMS EACH SIDE UPRIGHT & PURLIN TO O 7 "xT' FASTENED TO COLUMN ATTACHED TO PURLIN W/ (2) WITH (2)#10x110SMS BOSS 1/2"SMS IMO SCREW B INTO SCREW BOSSES FOR BOSS SMB OR SNAP COLUMN ATTACHED TO2"x2"x.050" EAVE RAIL MEMBER W/ #10xi-1/2" SMS 24" O.C. NOTE: A RECEIVING CHANNEL (ifl6" THICKNESS) IMTH (4) #10x314" SMS AT EACH CONNECTION MAY BE USED IN PLACE OF THE (2) #10x3" SCREW BOSS CONNECTION. REVIEWED FOR CODE COMPLIANCE ST. LUCIE,�COUNTY R0C,r_ (4) #10x3/4" SMS FASTENING SECONDARY ANGLE TO COLUMN (TYP EACH SIDE) (B) 318" 0 CONCRETE SCREW ANCHOR INTO SECONDARY ANGLE (TYP EACH SIDE) (SEE TABLE) ANCHORSPA (MIN) (TYP) (SEE TABLE) COLUMN SIZE 300 CONCRETESCREW ANCHOR B MIN SPA 2X3 0 0 2X4 1 3 2X5 1 3 2X6 1 4 1 52 32 ff 4 241 NOTES: SECONDARY ANGLE MIN 0.125" THICK (NOT REQUIRED FOR 2X3 MEMBER) 2"x2" 0.125" ANGLE ) #10x3/4" SMS FASTENING OLUMN TO PRIMARY ANGLE OPTION #1 TYP EACH SIDE) WRIMARY x2"BASE MEMBER TYP EACH SIDE)(4)#10xi 1/2"SMS)3/8" O CONCRETE SCREWINTO SCREW BOSSESOPTION#2 NCHOR INTO PRIMARY NGLE AND @ 1/4" 0 CONCRETE �3MIN. CREW ANCHOR @4"O.C. BETWEEN COLUMNS I (TYP EACH SIDE) ________ ______ 1. NUMBER OF ANCHORS "B" IS EACH SIDE INTO THE SECONDARY ANGLE AND DOES NOT INCLUDE THE ANCHOR INTO THE 1X2. 2. MINIMUM EMBEDMENT OF ANCHORS INTO CONCRETE FOOTING SHALL BE 2 3W AT ALL UPRIGHT LOCATIONS. ALL SCREW LENGTH AT UPRIGHT CONNECTIONS SHALL BE OF SUFFICIENT LENGTH FOR REQUIRED EMBEDMENT INTO CONCRETE FOOTING WHEN A PAVER DECKISPRESENT. 3. CONCRETE SCREW ANCHOR DESIGNS ARE BASED ON THOSE LISTED ON S-1, D. FASTENERS, OTHER BRAND & TYPE SHALL BE APPROVED BY ENGINEER. 4. 2X3 W/ 1X2 CORNER POST SHALL REQUIRE SAME BASE CONNECTIONS AS 2X4 SHOWN IN TABLE. 5. IF FOR AN IN -FILL, TOP OF COLUMN CONNECTIONS SIMILAR IF CONCRETE LINTEL IF WOOD LINTEL SUBSTITUTE 1/4" OX3" LAG SCREW FOR 3/8" 0 LDT FOR BOTH PRIMARY & SECONDARY ANGLES. 6. 2X2X.045 DOOR JAMB MEMBER SHALL CONNECT SIMILAR TO 2X3 MEMBER. 2"xY OR LARGER UPRIGHT TO CONCRETE W/WO PAVER DETAILS SCALE:NTS PTION #1 -A-36 STEEL CUP MAY BY PLACED ON o� TOP OR SIDE OF DECK W/ p SLEEVE TOP OF A CHOR" ANCHOR L CONCRETE DOUBLE COMPRESSION SLEEVES e O O a 4"NOMINALSLAB u d a MINIMUM 3/8"OX3"MASONRY OPTION #1 ANCHOR (MIN 33/4" . 2500 PSI CONCRETE W/ EMBEDMENT 4" SLAB ONLY WELDED WIRE OR FIBERMESH 125" STAINLESS STEEL CABLE 2500 PSI CONCRETE W/ $h WELDED WRE OR TOP OF FIBERMESH CONCRETE 4" NOMINAL SLAB MINIMUM 11/2"X512'ALUMINUM J OPTION #2 STRAP W/ (2) 3/8" OX3" USE WITH FOOTING MASONRVANCHOR (MIN 33/4" EMBEDMENT) CABLE TO FOUNDATION CONNECTION DETAIL SCALE:NTS 2"x2' OR ZXY3 MEMBER .062" ALUMINUM INTERNAL OR EXTERNAL RECEIVING CHANNEL W/ (4) #10x3/4" INTO BEAM OR UPRIGHT (2) #14x3/4" EA LEG INTO GIRT OR PURLIN(0.062"ANGLE CLIPS W/ (2) #14x3/4" SMS EA LEG) PRIGHT OR BEAM - SNAP OR SELF MATING OR HOLLOW PURLIN OR GIRT TO BEAM OR POST DETAIL SCALE:NTS ANGLE O O ( TOP AND SIDE) TYP O O NOTE: WHEN USING OPTION#2 /8" DIASTAINLESS STEEL CABLE CONNECTION CABLE MUST BE WITHIN 6"OF CORNER OR PRIMARY MEMBER. 3/8"WELDED STAINLESS STEEL EYE BOLT (8) #14x3/4 SMS SIDE VIEW "0 (MIN) WASHER HENEATH NUT , O O ----_ __ ____ ______ O O O O O O I I TOPVIEW 1 Oi 0 1 O 3/8"O ADJUSTABLE EYE BOLT FOR CABLE TENSION W OPTION #2 o /8" 0 STAINLESS STEELCA13LE SIDE VIEW ON 45"ANGLE OPTION #1 CABLE CONNECTION AT CORNER SCALE:NTS ANGLE OR PURLIN R FLAT (1) 3/8" DIA THRU BOLT W/ NYLON LOCKING NUT OR THREAD LOCKING MATERIAL APPLIED _z:vJ o O -�'LU o O � '//11n11111W% OR PURLIN REVIEWED FOR 3013E COMPLIANCE ST. LUCIE COUNTY soCC ROOF BRACING CONNECTION DETAIL SCALE:NTS IA. MACHINE BOLTS CIA. WASHERS THRU BEAM & POST ® CARRIER BEAM POST VARIES OPTIONAL 2XT FASTENED TO CARRIER BEAM w/(2) # I0,1-1 /2' SMS INTO SCREW BOSSES EACH END CARRIER BEAM O O 0 OPTIONAL O 1'57 MEMBER FOR SCREENING #10X1-1/2'SMS024" O.C. MAX CONNECTING O TO FX2' CARRIER BEAM #1041-I/2' SMS B 24" O.C. MAX CONNECTING �Tk2k0.125'• \I 2'FOR SINGLE RECEIVING CHANNEL HORIZONTAL BEAM OR ANGLE EACH SIDE 4'FOR DOUBLE HORIZONTAL (6)#IW.75'SMS BEAM OR 4'k4" EACH SIDE CFOR TRIPLE HORIZONTAL BEAM OR 6X6 (12) #1M.75'SMS 2 ROWS OF (6) FOR RECEIVING CHANNEL OR (6) EACH ANGLE CARRIER BEAM TO POST DETAIL SCALE: NTS MAY USE (3) #14XI"TEK IN LIEU OF THRUBOLTS (2) 3/8"0IA. MACHINE BOLTS w/ WASHERS (2) 3/8'ON BOLTS SEE NOTE # I ITHIS PAGE FOR BOLT PLACEMENT (2) 3/8" DIA. EXPANSION BOLTS SEE NOTE # I THIS PAGE FOR BOLT PLACEMENT TOP VIEW TFROM EDGE OF SLAB/FTG. (4) 1/4'531/4'TAPCON THRU BOTTOM LEG OF 35250.125 ANGLE ANGLE INTO CONC. 3000 PSI CONC. SLAB/FTG. FRONTVIEW 6x6-I0XI0 WWM OR FIBERMESH 3"x3" POST CONNECTION DETAIL SCALE: NTS ZVW.125' ANGLE EACH SIDE TYP. NOTE: FOR DOUBLE OR TRIBLE CARRIER BEAM, OUTSIDE WEBS SHALL OVERLAP 40 POST OR NOTCH POST AS ABOVE FOR 6x6 POST. ALL CASES, CONNECT USING MACHINE BOLTS DECRIBED ABOVE. ROOF BEAM TO CARRIER BEAM CONNECTION DETAIL SCALE: NTS (4) 1/45L11/4"TAPCON THRU BOTTOM LEG OF ANGLE INTO COLIC. (2) 3/8" DIA. MACHINE BOLTS w/ WASHERS 3-3/4" FROM EDGE- - OF SLAB/FTG. MAY USE (3) #14XI"TEK TOP VIEW IN LIEU OF THRUBOLTS 3x3•PosT PER PLAN r1 (LENGTH) (LEENGTH) ANGLE (INTERNAL) 3000 PSI CONC. ••�'••�•• SLAB/FTG. 6x6-10x10 W WM OR FIBERMESH FRONT VIEW XXX POST CONNECTION DETAIL (INTERNAL BASE) SCALE: N.T.S. NOTES: 1.3x3 POST TO HAVE 3/8" RED HEAD- TRUBOLT WEDGE ANCHORS (STAINLESS STEEL, PROVIDE MINIMUM 2" FROM EDGE OF SLAB AND PROVIDE MINIMUM 2" SPACING TO ANY OTHER CONNECTOR. SEE MFG. NOTES FOR INSTALLATION REQUIREMENTS. THREADED ROD REQUIRES 3" MINIMUM EDGE DISTANCE. 2.4x4 POST TO HAVE 1/2" REDHEAD - TRUBOLT WEDGE ANCHORS (STAINLESS STEEL, PROVIDE MINIMUM 3-3/4" FROM EDGE OF SLAB AND PROVIDE MINIMUM 3-3/4" SPACING TO ANY OTHER CONNECTOR. SEE MFG. NOTES FOR INSTALLATION REQUIREMENTS. 3. W HERE PAVERS ARE PRESENT ANCHOR LENGTH SHALL BE INCREASED BY THICKNESS OF PAVER NOT TO EXCEED 2-1/2' FOR PAVER THICKNESS MORE THAN 2-1 /7 SPECIFICATIONS SHALL BE REQUIRED. PAVERS SHALL BE BONDED TO UNDERLYING CONCRETE FOUNDATION. ROOF BEAMTO C.B. W/ 1/9" ANGLE TABLE BEAM SIZE QUANTITY/SIZE EA. LEG TO BEAM 2x4 (4)#12 OR(2)#16 2X5 (5)#12 OR(3)#16 2X6 (5)#12 OR(3)#I6 2x7 (bl #140R (41#76 2X8 (71 #140R (4)#16 2x9 (8)#14OR (5)#16 2X 10 (9)#140R (6)#I6 1 /SkxTxT x LENGTH CUT TO HT ANGLE FASTEN EACH (3) 1/4" DIA. MACHINE BOLTS w/ 3/4" DIA. WASHERS THRU CARRIER BEAM & POST TOP VIEW CARRIE oil CARRIER BEAM O (3) 1/4"DIA. w/ 3/4" DIA. CARRIER BE O (3) 1/4" DIA. MACHINE BOLTS POST w/ 3/4" DIA. WASHERS THRU CARRIER BEAM & POST FRONT VIEW CORNER CARRIER BEAM CONNECTION DETAIL SCALE: NTS 116WXl x LENGTH CUT TO EACH SIDE OF BEAM I.I EXISTING HOST STRUCTURE (DESIGNED BY OTHERS) MACHINE BOLTS WASHERS THRU 4M & POST BEAM POST �QLV�•41 co O O O: =�:W o r �. =0:V ¢ z N '///////IIIIIIIr111115\\ U � N J o Lrn J rn �11 M LJ z Q E Z��0 O U WJ0orn L J < LL_ Lo Z o fn ~ co c z oOr H U 0CDQf J O IL ILL 0 0 r` 0 N O Z U Lu O of Q. 0 0 BEAM PER PLAN a o W r F- U) lJ Q w } C.).044 CLOSE TOP OF J SIDE VIEW BEAM WHEN TRIMMED RECEIVING CHANNEL. :D i/i Q I'Y FASTENw/912SMS 0 N d W. EACH SIDE OF BEAM z FL O d BEAM TO GUTTER/HOST CONNECTION a ¢ CNI I'. O SCALE: NTS Y w o Lo ILL. z Q o m U a DESIGN DATE: 07108/2020 REVISION 1: DATE REVISION 2: DATE PAGE: DRAWN BY: TCP G SCALE: NTS J