HomeMy WebLinkAbout Soil Density - Verizon SCI To.pdfTested For: 1290 Old Congress Avenue West Palm Beach, Florida - 33409 Brad Schehr Cc: Attention: Title:Project Manager Brad Schehr (brad@jcromptonelectric.com) Project #:7112-20-231-003 Project:Verizon-SCI Towers Wynne Address:31310 Orange Avenue Fort Pierce, Florida - 34945, United States Joel Hernandez Permit #: Inspector: J. Crompton Electric, Inc.08/04/2020Report Date: General Location:(Verizon) Equipment Pads Test Method:ASTM D-6938 (Nuclear)Field Activity Date:07/30/2020 Gauge Make:Troxler Project Specifications:95 % Gauge Model:3440 Modified Proctor(AASHTO T-180) Gauge S/N:65674 Retest Required:Yes X No Test Date Proctor Number Soil Description Max. Dry Density (pcf) Optimum Moisture (%) 07/30/2020 L1 Light Brown Sand With Rock & Traces of Shell 110.6 10.5 Test No Elevation or Re-Test No Depth (Inch)Test Location Proctor Max Density (lbs/ft^3) Proctor Optimum Moisture (%) Field Percent Moisture (%) Field Density (lbs/ft^3) Percent Compaction (%) Spec: 95 Meet Spec ? 1 Pad 12 Southside of Center Equipment Pad 110.6 10.5 8.3 109.9 99.4 Yes 2 Pad 12 Center of Eastside Equipment Pad 110.6 10.5 7.2 110.3 99.7 Yes 3 Pad 12 Center of Westside Equipment Pad 110.6 10.5 8.9 110.9 100.3 Yes 0 - 0 - Remarks: Report Copied to: Notes: As requested, a representative from our company arrived on site as scheduled and performed the above test. These test results apply only to the specific locations noted and do not represent any other location. Reports may not be reproduced except in full, without permission. Field Compaction Tests Page 1 of 1 Tested For: Brad Schehr Title:Project Manager Cc: Project: Project #: Address: Inspector: Verizon-SCI Towers Wynne 31310 Orange Avenue Juan Rosa Proctor #:L1 Fort Pierce, Florida - 34945, United States West Palm Beach, Florida - 33409 1290 Old Congress Avenue Brad Schehr (brad@jcromptonelectric.com) 7112-20-231-002-L1 Permit #: 08/04/2020Report Date:J. Crompton Electric, Inc. Attention: 6 8 10 12 14 Moisture Content (%) 105 106 107 108 109 110 111 112 Dr y D e n s i t y ( p c f ) Light Brown Sand With Rock & Traces of Shell Equipment Pad - BackfillSample Source: Method of Test:Modified Proctor (ASTM D-1557) Test Results Maximum Dry Density (pcf): 110.6 pcf 10.5 %Optimum Moisture (%): Visual Classification: 07/30/2020Field Activity Date: Notes: As requested, a representative from our company arrived on site as scheduled to sample materials to perform the above tests. Reports may not be reproduced except in full, without permission. Report Copied to: Remarks: Moisture Density Relationship - Proctor