Loading...
HomeMy WebLinkAboutEnergy Code901:78I:1,111 Z11Yl FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 28 Block 5 Waterstone 1485 AGR Builder Name: ADAMS HOMES Street: 5348 Vespers Street Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(1401.5 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1144.10 ft2 b. Frame - Wood, Adjacent R=13.0 257.45 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1489.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1489.00 ft2 6. Conditioned floor area above grade (ft2) 1489 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(196.6 sqft.) Description Area a. Sup: Attic, Ret: Main, AH: Main 6 297.8 a. U-Factor: Dbl, U=0.33 129.50 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 36.00 ft 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl, U=0.55 17.78 ft2 SHGC: SHGC=0.70 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 13.33 ft2 a. Electric Heat Pump 28.2 HSPF:8.50 SHGC: other (see details) Area Weighted Average Overhang Depth: 4.207 ft. Area Weighted Average SHGC: 0.274 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1489.0 sqft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 1489.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.132 Total Proposed Modified Loads: 50.36 PASS Total Baseline Loads: 52.48 1 hereby certify that the plans and specifications covered by Review of the plans and ST,gpA this calculation are in compliance 't . %Florida Enenay.�-�, specifications covered by this �F'CHH Code. calculation indicates compliance y ri„ °j = 9s° with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: n this building will be inspected for compliance with Section 553.908 w� ,� a I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida ���C 1N6 OWNER/AGE BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. '- - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 6/12/2020 11:21 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 28 Block 5 Waterston 14 Bedrooms: 3 User Conditioned Area: 1489 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Single-family New (From Plans) Address Type: Lot Information Lot # 28 . Block/Subdivision: Waterstone PlatBook: Street: 5348 Vespers Street County: St. Lucie City, State, Zip: Fort Pierce, FL, 34951 CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blocki 1489 13549.9 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfI ID Finished Cooled Heated 1 Main 1489 13549.9 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 134.8 ft 0 1489 ft2 ___ 0.46 0 0.64 ROOF _ / V # Type Roof Gable Roof Materials Area Area Color Red Solar SA Emitl Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1665 ft2 372 ft2 Medium N 0.85 No 0.85 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1489 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Fmc Truss Type 1 Under Attic(Vented) Main 30 Blown 1489 ft2 0.11 Wood 6/12/2020 11:21 AM EnergyGauge® USA 6.0.02 (Rev. 1) - F1aRes2017 FBC 61h Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Spam Cavity Width Height P Sheathing Framing Solar Below o 1 S Exterior Concrete Block - Int Insul Main 4.1 31 6 8 3 259.9 ft' 0 0 0.6 0 _ 2 E Exterior Concrete Block - Int Insul Main 4.1 8 3 10 11 90.1 ft2 0 0.6 0 _ 3 N Exterior Concrete Block - Int Insul Main 4.1 45 1 8 3 371.9 ft' 0 0 0.6 0 -4 W Exterior Concrete Block - Int Insul Main 4.1 37 10 8 3 312.1 ft' 0 0 0.6 0 -5 - Garage Frame - Wood Main 13 23 7 10 11 257.6 ft2 0 0.23 0.01 0 6 E Exterior Concrete Block - Int Insul Main 4.1 10 1 10 11 110.1 ft2 0 0 0.6 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated Main None .25 3 6 8 20 ft' 2 - Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 1 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft' 1 ft4 in 0 ft 8 in Drapes/blinds Exterior5 2 E 2 Vinyl Low-E Double Yes 0.33 0.21 N 18.0 ft' 1 It 0 in 5 It 0 in Drapes/blinds Exterior 5 3 E 2 Vinyl Low-E Double Yes 0.33 0.21 N 18.0 ft' 1 It 0 in 3 It 8 in Drapes/blinds Exterior 5 4 E 6 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft2 7 ft 0 in 0 It 6 in Drapes/blinds Exterior 5 5 N 3 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 4 in 0 ft 8 in Drapes/blinds Exterior 5 6 W 4 Metal Low-E Double Yes 0.55 0.7 N 17.8 ft2 11 ft 4 in 0 ft 8 in Drapes/blinds Exterior 5 7 W 4 Vinyl Low-E Double Yes 0.33 0.23 N 64.8 W 1 ft 4 in 0 ft 8 in Drapes/blinds Exterior 5 8 W 4 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 11 ft 4 in 0 ft 10 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 389 ft2 389 ft2 64 ft 8 It 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000405 1580.8 86.78 163.21 .1477 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heal Pump/ Split HSPF:8.5 28.2 kBtu/hr 1 sys#1 6/12/2020 11:21 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 28.4 kBtu/hr 947 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Carl # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS _ / —Supply— Return Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 297.8 ft Main 74.45 ft Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programablee Ceiling Fans: jThermostar[t:'JY Feb Heat ng I Jan Feb Mar H Apr Apr € [X] DC1 ayXl Jun ] Jul (1 Aug [X] ] Sep [[X]] Dec Venting [ 1 Jan I 1 Feb L 1 X Mar MMe ay lJun 1 Jul I ]Aug E l 11 Sep E Oct [X] NNo' ov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 W 0 ft 0.3 Main 6/12/2020 11:21 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX" = 96 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 28.4 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1489 d) Room uniUPTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.350 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.274 14. Heating system: Capacity 28.2 c) Area 7c. 196.6 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a.' NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 81b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 91b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.94 " b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 13.0 2. Masonry (Insulation R-value) 1062. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 1la. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signatufe \ � Date: Address of New Home: 5348 Vespera Street City/FL Zip: Fort Pierce, FL 34951 6/12/2020 11:21:45 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1